• Title/Summary/Keyword: 환기 성능

Search Result 723, Processing Time 0.019 seconds

Development of heat exchanger for underground water heat. II - Design and manufacture for heat exchanger of underground water - (지하수 이용을 위한 열교환기 개발. II - 지하수이용 냉·난방기 설계제작 -)

  • Lee, W.Y.;Ahn, D.H.;Kim, S.C.;Park, W.P.;Kang, Y.G.;Kim, S.B.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.4 no.1
    • /
    • pp.128-137
    • /
    • 2002
  • This study was conducted to develop the heat exchanger by utilizing the heat energy of underground water(15℃), which might be used for cooling and heating system of the agricultural facilities. We developed the heat exchanger by using the parallel type plat fin tube made of Aluminum(Al 6063), which was named Aloo-Heat(No. 0247164, offered by Korean Intellectual property Office). The trial manufactures were made from Aloo-heat which was 600mm, 700mm length respectively, and It were welded to the end "U" type in order to direct flow of the underground water. The performance test was carried out under the condition of open space and room temperature with the change of flow rate of the underground water and air. The results are as follows. 1. The trial manufactures had convection heat value from 33 to 156 W/m2℃, and It was coincided with design assumption. 2. The amount of energy transfer was increased with the increment of the area of heat transfer, the air flow, the gap of temperature inlet & outlet the underground water and the air. 3. The heat value was 6,825W when the air flow was 6,000m3/h and the gap of temperature between inlet and outlet of the underground water was 6℃, and It dropped from 25.8℃ to 23.2℃(-2.6℃ difference). The convection heat value was 88.5W/m2℃. 4. The heat value was 2.625W when the air flow was 4,000m3/h and the gap of temperature between inlet and outlet the underground water was 2℃, and It dropped from 27℃ to 22.5℃(-4.5℃ difference). The convection heat value was 33.6W/m2℃. 5. Correlation values(R2) of the testing heat values of the trial manufacture type I, II, and III were 0.9141, 0.8935, and 0.9323 respectively, and correlation values(R2) of the amount of the air flow 6,000m3/h, 5,000m3/h, 4,000m3/h were 0.9513, 0.9414, and 0.9003 respectively.

Study on PM10, PM2.5 Reduction Effects and Measurement Method of Vegetation Bio-Filters System in Multi-Use Facility (다중이용시설 내 식생바이오필터 시스템의 PM10, PM2.5 저감효과 및 측정방법에 대한 연구)

  • Kim, Tae-Han;Choi, Boo-Hun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.48 no.5
    • /
    • pp.80-88
    • /
    • 2020
  • With the issuance of one-week fine dust emergency reduction measures in March 2019, the public's anxiety about fine dust is increasingly growing. In order to assess the application of air purifying plant-based bio-filters to public facilities, this study presented a method for measuring pollutant reduction effects by creating an indoor environment for continuous discharge of particle pollutants and conducted basic studies to verify whether indoor air quality has improved through the system. In this study conducted in a lecture room in spring, the background concentration was created by using mosquito repellent incense as a pollutant one hour before monitoring. Then, according to the schedule, the fine dust reduction capacity was monitored by irrigating for two hours and venting air for one hour. PM10, PM2.5, and temperature & humidity sensors were installed two meters front of the bio-filters, and velocity probes were installed at the center of the three air vents to conduct time-series monitoring. The average face velocity of three air vents set up in the bio-filter was 0.38±0.16 m/s. Total air-conditioning air volume was calculated at 776.89±320.16㎥/h by applying an air vent area of 0.29m×0.65m after deducing damper area. With the system in operation, average temperature and average relative humidity were maintained at 21.5-22.3℃, and 63.79-73.6%, respectively, which indicates that it satisfies temperature and humidity range of various conditions of preceding studies. When the effects of raising relatively humidity rapidly by operating system's air-conditioning function are used efficiently, it would be possible to reduce indoor fine dust and maintain appropriate relative humidity seasonally. Concentration of fine dust increased the same in all cycles before operating the bio-filter system. After operating the system, in cycle 1 blast section (C-1, β=-3.83, β=-2.45), particulate matters (PM10) were lowered by up to 28.8% or 560.3㎍/㎥ and fine particulate matters (PM2.5) were reduced by up to 28.0% or 350.0㎍/㎥. Then, the concentration of find dust (PM10, PM2.5) was reduced by up to 32.6% or 647.0㎍/㎥ and 32.4% or 401.3㎍/㎥ respectively through reduction in cycle 2 blast section (C-2, β=-5.50, β=-3.30) and up to 30.8% or 732.7㎍/㎥ and 31.0% or 459.3㎍/㎥ respectively through reduction in cycle 3 blast section (C-3, β=5.48, β=-3.51). By referring to standards and regulations related to the installation of vegetation bio-filters in public facilities, this study provided plans on how to set up objective performance evaluation environment. By doing so, it was possible to create monitoring infrastructure more objective than a regular lecture room environment and secure relatively reliable data.

A Survey on Physical Complaints Related with Farmers' Syndrome of Vinylhouse and Non-vinylhouse Farmers (비닐하우스 재배농민과 일반농민의 농부증 관련 신체증상 호소율 조사)

  • Lee, Ju-Young;Park, Jung-Han;Kim, Doo-Hie
    • Journal of Preventive Medicine and Public Health
    • /
    • v.27 no.2 s.46
    • /
    • pp.258-273
    • /
    • 1994
  • To compare the physical complaints of vinylhouse farmers with those of non-vinylhouse farmers, a personal interviews on 250 vinylhouse and 142 non-vinylhouse farmers were conducted in Sungjoo county in Kyungpook province selected by a random sampling from July 5 to July 10, 1993. Blood pressure of the subjects was also measured. Vinylhouse farmers had a higher average age, larger family size, shorter experience of farming, more working hours per day and working days per year and higher annual income than the non-vinylhouse farmers. The frequency of pesticide spray of the vinylhouse farmers was 3.4 times on the average in June 1993 as compared with 2.0 times of non-vinylhouse farmers, and 16.7 times for the vinylhouse farmers during the last one year while it was 8.3 times for the non-vinylhouse farmers in the same period. While 39.6% of vinylhouse farmers experienced pesticide intoxication symptoms such as headache, nausea, vomiting, dizziness, itching, and skin irritation, etc. during the month of June, 25.4% of non-vinylhouse farmers experienced such symptoms. The most frequent symptoms among eight symptoms that constitute the farmers' syndrome were lumbago, numbness of hand or foot, shoulder pain and dizziness regardless of sex and type of farming. Prevalence of the farmers' syndrome in male and female among vinylhouse farmers were 22.1%, 43.4%, respectively, and the prevalence in non-vinylhouse farmers was 23.2% for male and 50.7% for female. There was no statistically significant difference in the prevalence of farmers' syndrome between vinylhouse and non-vinylhouse farmers. However, the prevalence in female was about 2 times higher than that of male. When the effects of other factors were adjusted by multiple logistic regression for farmers' syndrome, the prevalence in female was 3.0 times higher than that of male. The prevalence of farmers' syndrome was increased as the age of farmers increased in both vinylhouse and non-vinylhouse farmers, and adjusted odds ratio of farmers' syndrome increased by 3% as the age increased by 1 year. Adjusted odds ratio for Farmers' syndrome in farmers who experienced pesticide intoxication during the month of June was 3.1 times higher than that of farmers who did not have such experience. While the prevalence of hypertension in male and female non-vinylhouse farmers were 22.4%, 13.7%, respectively, the prevalence in vinylhouse farmers were 13.5% for male and 12.0% for female. However, there was no association between farmers' syndrome and hypertension. It was found in this study that the vinylhouse farmers are at a high risk of pesticide intoxication, which is associated with tile common physical complaints. To reduce such risk it is necessary to develop farming methods which do not require the pesticide or may use less pesticide, a safer method of pesticide spraying, and the protective equipments which can be worn at a high temperature and have a better protective effect. Also education of farmers for the correct methods of ventilation after pesticide spraying in the vinylhouse and wearing the protective equipments may be considered as a supportive method. Since inappropriate posture at work and intensive labor may cause farmers' syndrome, it is recommended to develop farming tools which reduce physical burden and take a rest and exercise periodically during work. It is necessary to strengthen the hypertension management program of the Kyungpook province, because the prevalence of hypertension was as high as about 15%.

  • PDF