• Title/Summary/Keyword: 환기형 초공동

Search Result 2, Processing Time 0.016 seconds

Study on Bubble Collecting Section of Cavitation Tunnel for Ventilated Supercavitation Experiments (환기 초공동 실험을 위한 캐비테이션 터널 기포 포집부 연구)

  • Paik, Bu-Geun;Park, Il-Ryong;Kim, Ki-Sup;Lee, Kurnchul;Kim, Min-Jae;Kim, Kyoung-Youl
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.53 no.4
    • /
    • pp.300-306
    • /
    • 2016
  • The gas ventilated by supercavitation splits into smaller bubbles and follows the water passage of the cavitation tunnel. The bubbles quickly return to the test section by rather high speed flow, and interrupt the observation of the supercavitation. To secure clear observation in the test section, the bubble collecting section(settling chamber) of large volume is prepared to collect bubbles in the water passage ahead of the test section. The bubble collecting section should provide enough buoyancy effect to the bubbles for proper bubble collecting. However, rather high-speed oncoming flow produces non-uniform velocity distribution and deteriorates buoyancy effect in the bubble collecting section. In the present study, the bubble collecting space and three porous plates are designed and analyzed through numerical methods, and the bubble collecting function is experimentally validated by 1/10-scaled model in terms of the formation of uniformly low velocity distribution in the bubble collecting section.

Fundamental Studies for Ventilated Supercavitation Experiments in New High-speed Cavitation Tunnel (신조된 고속 캐비테이션 터널에서 환기 초공동 실험 수행을 위한 기초 연구)

  • Paik, Bu-Geun;Kim, Min-Jae;Jung, Young-Rae;Lee, Seung-Jae;Kim, Kyoung-Youl;Ahn, Jong-Woo;Seol, Han-Shin;Kim, Ki-Sup
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.55 no.4
    • /
    • pp.330-340
    • /
    • 2018
  • In the present works, the High-speed Cavitation Tunnel (HCT) has been designed and manufactured to have the large test section to conduct various supercavitation experiments. The large amount of air ventilated behind a cavitator produces lots of tiny bubbles, which prevent clear observation of supercavitation at the test section. To collect small bubbles effectively, a bubble collecting section of large volume is equipped upstream of the test section. HCT has the test section dimension of $0.3^H{\times}0.3^W{\times}3.0^L\;m^3$ and provides maximum flow speed of 20.4 m/s at the test section. The blockage and Froude effects on the ventilated supercavitation are investigated successfully at the test section. The basic studies such as the supercavitation evolution, drag measurements and cavity shape extraction with air flow rate are also carried out in HCT.