• Title/Summary/Keyword: 환경 감쇠

Search Result 288, Processing Time 0.025 seconds

Study on Wave Reduction and Beach sand Capture Performance of Artificial Coral Reefs for In-situ Application (해안침식 현장 적용을 위한 인공산호초 연성공법의 파고 감쇠 및 침식해빈사 포집성능 분석)

  • Hong, Sung-Hoon;Kim, Tae-Yoon;Choi, Yun-Shik;Kim, Jeong-Ho;Kwon, Yong-Ju;Lee, Si-Hyeon;Lee, Gwang-Soo;Kwon, Soon-Chul
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.6
    • /
    • pp.485-491
    • /
    • 2018
  • Because of the increase in coastal erosion problems, many studies have been conducted to prevent coastline retreat by developing low-cost, highly effective countermeasures. We developed the artificial coral reefs (ACRs) method as part of this research trend. To verify its coastal protection performance, we carried out performance tests on its wave attenuation and beach sand capture ability, which are the key barometers for this newly developed technology. In this study, three different types of methods, including natural beach, TTP, and ACRs, were used to determine the coastal protection efficiency under both ordinary and storm wave conditions. Based on the results of this study, ACRs were found to have the best wave attenuation performance and captured more than 20% of the total erosion area. This means the ACR method can be applied as a reliable countermeasure to protect a coastal zone.

Section Model Study on the Aerodynamic Behaviors of the Cable-Stayed Bridges with Two I-Type Girders Considering Structural Damping and Turbulence Intensity (2개의 I형 거더를 가진 사장교의 구조감쇠비 및 난류강도를 고려한 공기역학적 거동에 관한 단면모형실험 연구)

  • Cho, Jae-Young;Kim, Young-Min;Cho, Young-Rae;Lee, Hak-Eun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.6A
    • /
    • pp.1013-1022
    • /
    • 2006
  • Although the cable-stayed bridges with two I-type girders inherently do not have good aerodynamic characteristics, a lot of the bridges with this type girders are constructed in Korea recently because of an economical merit. This paper investigated the aerodynamic characteristics of the cable-stayed bridges with two I-type girders. Section model tests were conducted in order to investigate the aerodynamic behaviors of this section with varying of the angles of attack, turbulence intensity and damping ratios. Two deck section configurations with different torsional stiffness were studied under construction and after completion respectively. Three types of the fairings were investigated to improve the aerodynamic characteristics of the bridges. The result of this study showed that the traditional section model test in uniform flow estimates the aerodynamic behavior rather pessimistically. The wind induced responses of the bridges were severely varied in accordance with the turbulence intensity and the structural damping ratio. The proposed fairing reduced the magnitude of the vortex-shedding vibrations and buffeting responses. It also increased the wind speed at which flutter occurs. It is expected that these investigations would provide a lot of information for the design of the cable stayed bridges with two I-type girders regarding wind resistance.

Vibration Reduction Evaluation of Jacket Structure by applying Precast Concrete Block and Suction pile (Precast Concrete Block 및 Suction pile을 적용한 Jacket 구조물의 진동저감 효과 평가)

  • Lee, Sung-Jin;Kyung, Kab-Soo;Ryu, Seong-Jin;Jeong, Ji-Young;Park, Jin-Eun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.4
    • /
    • pp.375-384
    • /
    • 2015
  • Recently, construction sites of offshore wind power tend to move from shallow water to deep water. From this tendency, the research on the support structure of offshore wind power in deep water will be a key issue. In this study, precast concrete block and suction pile are applied to existing jacket structure. In order to reduce the vibration of this structure, the tuned liquid damper is also applied in the precast concrete block. The applicability of the suggested jacket structure is evaluated by finite element analysis. And the vibration tends to decrease about 5%, when the tuned liquid damper is applied.

Optimization of Ultrasonic Soil Washing Processes Using Aluminum Foil Erosion Tests (알루미늄 호일 부식 실험을 이용한 초음파 토양 세척 공정 개발의 기초 연구)

  • Kim, Seulgi;Son, Younggyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.2
    • /
    • pp.92-98
    • /
    • 2015
  • The physical effect induced by acoustic cavitation was investigated to accumulate basic data for the design of ultrasonic soil washing processes using aluminum foil erosion tests. A square aluminum foil was placed on the glass beads in the pyrex vessel submerged in the sonoreactor equipped with a 36 kHz ultrasound transducer module at the bottom. Cavitational erosion of foils was quantitatively analyzed for various glass bead diameter conditions (1, 2, and 4 mm), glass bead height conditions (5, 10, 15, and 20 mm), and water height conditions (5, 10, 15, and 20 mm). It was found that aluminum foil erosion significantly increased as the glass bead diameter increased and water height over the glass bead increased due to less attenuation of ultrasound and the optimization of sound field for cavitation. Moreover mechanical mixing was suggested to move constantly particles to the bottom area where the acoustic cavitation occurs most violently. It was because aluminium foil erosion by ultrasound transmitted through glass beads was relatively too weak.

Passive Control System for Mitigation of Cable Vibration in Cable-Stayed Bridges (사장교의 케이블 진동저감을 위한 수동 제어시스템)

  • Hwang, Inho;Lee, Jong Seh
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5A
    • /
    • pp.881-885
    • /
    • 2006
  • Rain-wind induced cable vibration can cause serious problems in cable-stayed bridges. Externally attached dampers have been used to provide an effective means to suppress the vibration of relatively short stay-cables. For very long stay-cables, however, such damper systems are rendered ineffective, as the dampers need to be attached near the end of cables for aesthetic reasons. This paper investigates a new control system to mitigate the cable vibration. The proposed control system which consists of a laminated rubber bearing and an internal damper may be installed inside of the cable anchorage. A simple analytical model of the cable-damper system is developed first based on the taut string representation of the cable. The response of a cable with the proposed control system is obtained and then compared to those of the cable with and without an external passive damper. The proposed stay-cable vibration control system is shown to perform better than the optimal passive viscous damper, thereby demonstrating its applicability in large cable-stayed bridges for mitigation of rain-wind induced vibration of stay-cables.

An Application of the Kalman Filter for Attenuation of Colored Noise Superimposed on Speech Signal (칼만필터를 이용한 음성신호에 중첩된 유색잡음의 감쇠)

  • Gu, Bon-Eung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.76-85
    • /
    • 1994
  • A speech enhancement algorithm which attenuates nonstationary colored noise is presented In this paper. The algorithm consists of a stationary Kalman filter and the simple speech/nonspeech detector. While the conventional enhancement systems are focused on a stationary and/or white background noise, this study Is focused on the mort realistic nonstationary and nonwhite noise. An AR model-based vector Kalman filter is used as a noise suppression system and a short-time energy threshold logic is used as a speech/nonspeech classifier. For Kalman filtering. noise coefficients are estimated in the nonspeech frame, and speech coefficients are estimated by applying the EM iteration algorithm. Simulation results using the car noise are presented based on the signal-to-noise ratio and informal listening tests. According to the experimental results, background noises in the nonspeech frames are eliminated almost completely, while some distortions are noticed in the speech frames. The distortion becomes severer as the SNR is reduced to 0dB and -5dB. Intelligibility, however, is not degraded significantly.

  • PDF

Proposal of Predictive Equations of Normalized Shear Modulus and Damping Ratio Curves for Loose Medium Sand Reinforced by Vinyl Strip-cement (비닐스트립-시멘트로 보강된 느슨한 중간 모래의 정규화 전단탄성계수 및 감쇠비 곡선 산정식 제안)

  • Kim, Jong-Min
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.12
    • /
    • pp.33-45
    • /
    • 2021
  • In this study, predictive equations of the normalized shear modulus and the damping ratio curves for loose medium sands reinforced by vinyl strip-cement are proposed. Based on the results of a series of resonant-column tests (Yu, et al., 2018) conducted under the confining stresses of 15, 30, 60 kPa on sand specimens prepared with 40% relative density and reinforced by various contents of vinyl strip (0.0, 0.1, 0.3, 0.4%) and cement (0, 1, 2%), the equations estimating the normalized shear modulus and the damping ratio are proposed as functions of reinforcing conditions and confining stresses. The comparison between predicted and measured values of shear modulus and damping ratio shows a good agreement and the reliability of proposed predictive equations are validated by high R2-value greater than 0.9. Therefore, it is expected that the time and the cost required for constructing the normalized shear modulus and the damping ratio curves will be much reduced by using proposed equations in this study since those can easily be estimated without conducting resonant-column test.

Movable Anchorage System for Mitigation of Cable Vibration in Cable-Stayed Bridges with Sag (Sag가 고려된 사장교 케이블의 진동저감을 위한 Movable Anchorage 시스템)

  • Hwang, Inho;Park, Jun Hyung;Lee, Jong Seh
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5A
    • /
    • pp.657-664
    • /
    • 2008
  • Rain-wind induced cable vibration can cause the damages in the cable-stayed bridge due to very little inherent damping characteristics and low fundamental frequency. External Dampers attached to stay cables near anchorages have been shown to be effective means at short stay-cables. However, installation locations of external dampers are limited to a particular range due to aesthetic and practical reasons for very long stay-cables. A recent study by the authors showed that the stay-cable vibration system can perform better than the optimal passive viscous damper, thereby demonstrating its applicability in large cable-stayed bridges. This paper extends the previous study on the taut string representation of the cable by adding cable sag and inclination. The response of the proposed system compared to those of the cable with and without an external damper, and the movable anchorage system provides very effective mitigation of cable vibration. Cable damping ratio is seen to be remarkably reduced by movable anchorage system for a wide range of cable sag. This result shows that the sag effects of the proposed system should be considered.

Analysis of the Impact of Transmission Towers on the Performance of RF Scanners for Drone Detection (드론탐지용 RF스캐너의 성능에 송전탑이 미치는 영향 분석)

  • Moon-Hee Lee;Jeong-Ju Bang
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.23 no.1
    • /
    • pp.112-122
    • /
    • 2024
  • Recently, as unmanned aerial vehicle technology such as drones has developed, there are many environmental, social and economic benefits, but if there is malicious intent against important national facilities such as airports, public institutions, power plants, and the military, it can seriously affect national safety and people's lives. It can cause damage. To respond to these drone threats, attempts are being made to introduce detection equipment such as RF scanners. In particular, power transmission towers installed in substations, power plants, and Korea's power system can affect detection performance if the transmission tower is located in the RF scanner detection path. In the experiment, a commercial drone was used to measure the signal intensity emitted from the drone and confirm the attenuation rate. The average and maximum attenuation rates showed similar trends in the 2.4 GHz and 5.8 GHz bands, and were also affected by the density of the structure.