• Title/Summary/Keyword: 환경의 질 평가

Search Result 1,011, Processing Time 0.033 seconds

Prediction of Nitrate Contamination of Groundwater in the Northern Nonsan area Using Multiple Regression Analysis (다중 회귀 분석을 이용한 논산 북부 지역 지하수의 질산성 질소 오염 예측)

  • Kim, Eun-Young;Koh, Dong-Chan;Ko, Kyung-Seok;Yeo, In-Wook
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.5
    • /
    • pp.57-73
    • /
    • 2008
  • Nitrate concentrations were measured up to 49 mg/L (as $NO_3$-N) and 22% of the samples exceeded drinking water standard in shallow and bedrock groundwater of the northern Nonsan area. Nitrate concentrations showed a significant difference among land use groups. To predict nitrate concentration in groundwater, multiple regression analysis was carried out using hydrogeologic parameters of soil media, topography and land use which were categorized as several groups, well depth and altitude, and field parameters of temperature, pH, DO and EC. Hydrogeologic parameters were quantified as area proportions of each category within circular buffers centering at wells. Regression was performed to all the combination of variables and the most relevant model was selected based on adjusted coefficient of determination (Adj. $R^2$). Regression using hydrogelogic parameters with varying buffer radii show highest Adj. $R^2$ at 50m and 300m for shallow and bedrock groundwater, respectively. Shallow groundwater has higher Adj. $R^2$ than bedrock groundwater indicating higher susceptibility to hydrogeologic properties of surface environment near the well. Land use and soil media was major explanatory variables for shallow and bedrock groundwater, respectively and residential area was a major variable in both shallow and bedrock groundwater. Regression involving hydrogeologic parameters and field parameters showed that EC, paddy and pH were major variables in shallow groundwater whereas DO, EC and natural area were in bedrock groundwater. Field parameters have much higher explanatory power over the hydrogeologic parameters suggesting field parameters which are routinely measured can provide important information on each well in assessment of nitrate contamination. The most relevant buffer radii can be applied to estimation of travel time of contaminants in surface environment to wells.

Investigation of Measurement Feasibility of Large-size Wastes Based on Unmanned Aerial System (UAS 기반 대형 폐기물 발생량 측정 가능성 모색)

  • Son, Seung Woo;Yu, Jae Jin;Jeon, Hyung Jin;Lim, Seong Ha;Kang, Young Eun;Yoon, Jeong Ho
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.5_3
    • /
    • pp.809-820
    • /
    • 2017
  • Efficient management of large-size wastes generated from disasters etc. is always in demand. Large-size wastes are closely connected to the environment, producing adverse effects on the air quality, water quality, living environment and so on. When large-size wastes are generated, we must be able to estimate the generated amount in order to transfer them to a temporary trans-shipment site, or to properly treat them. Currently, we estimate the amount of generated large-size wastes by using satellite images or unit measure for wastes; however, the accuracy of such estimations have been constantly questioned. Therefore, the present study was performed to establish three-dimensional spatial information based on UAS, to measure the amount of waste, and to evaluate the accuracy of the measurement. A measurement was made at a waste site by using UAS, and the X, Y, Z RMSE values of the three-dimensional spatial information were found to be 0.022 m, 0.023 m, and 0.14 m, all of which show relatively high accuracy. The amount of waste measured using these values was computed to be approximately $4,273,400m^3$. In addition, the amount of waste at the same site was measured by using Terrestrial LiDAR, which is used for the precise measurement of geographical features, cultural properties and the like. The resulting value was $4,274,188m^3$, which is not significantly different from the amount of waste computed by using UAS. Thus, the possibility of measuring the amount of waste using UAS was confirmed, and UAS-based measurement is believed to be useful for environmental control with respect to disaster wastes, large-size wastes, and the like.

Influence of the Increase of Dissolved $CO_2$ Concentration on the Marine Organisms and Ecosystems (해수중 용존 $CO_2$ 농도 증가가 해양생물 및 해양생태계에 미치는 영향: 국내외 사례 연구)

  • Lee, Jung-Suk;Lee, Kyu-Tae;Kim, Chan-Kook;Park, Gun-Ho;Lee, Jong-Hyeon;Park, Young-Gyu;Gang, Seong-Gil
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.9 no.4
    • /
    • pp.243-252
    • /
    • 2006
  • Influence of the increasing carbon dioxide concentration in seawater on various marine organisms is assessed in this article with regard to the impacts of anthropogenic $CO_2$ introduced into surface or deep oceans. Recent proposals to sequester $CO_2$ in deep oceans arouse the concerns of adverse effects of increased $CO_2$ concentration on deep-sea organisms. Atmospheric introduction of $CO_2$ into the ocean can also acidify the surface water, thereby the population of some sensitive organisms including coral reefs, cocolithophorids and sea urchins will be reduced considerably in near future (e.g. in 2100 unless the increasing trend of $CO_2$ emission is actively regulated). We exposed bioluminescent bacteria and benthic amphipods to varying concentrations of $CO_2$ and also pH for a short period. The ${\sim}l.5$ unit decrease of pH adversely affected test organisms. However, amphipods were not influenced by decreasing pH when HCl was used for the seawater acidification. In this article, we reviewed the biological adverse effects of $CO_2$ on various marine organisms studied so for. Theses results will be useful to predict the potential risks of the increase of $CO_2$ concentrations in seawater due to the increase of atmospheric $CO_2$ emission and/or sequestration of $CO_2$ in deep oceans.

  • PDF

Comparison of Student Satisfaction with Foodservice of Middle School by Place for Meal Service in Busan Area (배식장소에 따른 부산 일부지역 중학생의 급식만족도 평가)

  • Lee, Kyung-A;Lyu, Eun-Soon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.2
    • /
    • pp.209-218
    • /
    • 2005
  • The purpose of this study was to evaluate the students' satisfaction with the Quality of middle school foodservice in Busan area. For purpose, Questionnaires were distributed to 788 students in 8 middle schools (four schools for classroom service, four schools for restaurant service). The average scores were -1.13 for gap of meal, -1.68 for sanitation, -1.19 for menu, -1.63 for attitude of foodservice staffs, and -0.89 for rapidity and exactness of service. The whole students assessed the important and performance of school food service 4.20/5.00 and 2.99/5.00. The restaurant service had significantly (p<0.01) higher average scores performance of meal, sanitation, and rapidity and exactness of service than those of the class room service. The Importance-Performance Analysis (IPA) gride, high importance and low performance (focus here) were cleanliness of dish, cleanliness restoration area, rapid treatment about complaints, reflection students' opinions, and listening to students' opinions in the classroom service and the restaurant service, but the Quality vs. price of meal, sanitation of meal, and dessert supply were included in focus here part in the classroom service.

Dinosaur Tracksite at Jeori, Geumseongmyeon, Euiseonggun, Gyeongsangbukdo, Korea(National Monument No. 373) - Occurrences, Significance in Natural History, and Preservation Plan - (경북 의성군 금성면 제오리 공룡발자국화석 산지(천연기념물 제373호) - 산상, 자연사적 가치 및 보존 방안 -)

  • Paik, In Sung;Kim, Hyun Joo;Kang, Hee Cheol;Lim, Jong-Deock
    • Korean Journal of Heritage: History & Science
    • /
    • v.46 no.1
    • /
    • pp.268-289
    • /
    • 2013
  • The Dinosaur tracksite at Jeori, Geumseongmyeon, Euiseonggun, Gyeongsangbukdo, Korea (National Monument No. 373) has been studied in the aspects of location, stratigraphy, sedimentology, fossil occurrence, unique geological records, literature, significance in natural history, preservation, and management. On the basis of these features, the Jeori tracksite has been assessed semiquantitavely. The Jeori tracksite occurs in the Sagok Formation (Albian) of the Euiseong sub-basin, and over 300 footprints forming 12 sauropod trackways, 10 ornithopod trackways, and 1 theropod trackways are preserved in this tracksite. The track-bearing deposits consist of tabular-bedded medium- to fine-grained arkose with mudstone drape, interlaminated fine-grained sandstone to siltstone and mudstone, and shaly mudstone. The dinosaur tracks are preserved in the interlaminated fine-grained sandstone to siltstone and mudstone, and most of them are observed as underprints. The track-bearing deposits are interpreted as sheetflood deposits on the floodplain under a seasonal paleoclimatic condition with alternating of wetting and drying periods. Multiple tension fractures with NE strike were formed in the track-bearing bed, which resulted in that tracks seem to occur in several horizons. The significance in natural history of the tracksite can be summarized as follows: 1) the historical implication of the Jeori tracksite as the firstly designated National Monument of dinosaur fossil sites, 2) the high density of the occurrence of diverse footprints (over 300) within small area (about $1,600m^2$), and 3) the significance of the tension fractures associated with the track-bearing bed as geoeducational records for the understanding the development of fault. In order to share the value of the Jeori tracksite in the aspect of natural history with the community and public, the interpretive panel should be modified to include figures explaining paleoenvironment and tension fault development. In addition it is recommended that a brochure be published briefly explaining the tracksite and to educate the residents about the natural and social significance of the tracksite. For the safety of visitors it would be desirable for the road in front of the tracksite to be moved at least 10 m southward, which could mitigate the shaking of the track bed caused by traffic.

Efficacy and Safety of $Ultracet^{(R)}$ in Ambulatory Patients with Cancer Pain (암환자의 통증치료에 대한 $Ultracet^{(R)}$의 유효성과 안전성)

  • Lee, Hyo-Jin;Jin, Sun-Ah;Yun, Gak-Won;Yang, Yung-Joon;Park, Nam-Whan;Chun, Jae-Min;Park, Nam-Sook;Yun, Hwan-Jung;Jo, Deog-Yeon;Kim, Sam-Yong
    • Journal of Hospice and Palliative Care
    • /
    • v.9 no.2
    • /
    • pp.101-105
    • /
    • 2006
  • Purpose: We aimed to investigate the efficacy and side effects of $Ultracet^{(R)}$ in relieving cancer pain in setting. Methods: Sixty-one cancer patients over 18 years old, who had cancer pain with or without medication, were enrolled. Pain and other variables were evaluated before and after treatment with $Ultracet^{(R)}$ for 2 weeks, using Korean version of Brief Pain Inventory. Results: Of 61 patients with assessable efficacy data, the maximum pain intensity(PI) experienced in a day were $5.18{\pm}1.41\;and\;4.82{\pm}1.94$, before and after treatment with$Ultracet^{(R)}$ respectively (P=0.113). The minimum PI experienced in a day were $1.2{\pm}1.05\;and\;0.87{\pm}1.35$, before and after treatment with $Ultracet^{(R)}$, respectively (P=0.038). The average PI experienced in a day were $3.61{\pm}1.01\;and\;3.15{\pm}1.73$, before and after treatment with $Ultracet^{(R)}$, respectively (P=0.022). The current PI were $3.63{\pm}1.25\;and\;2.85{\pm}1.94$, before and after treatment with $Ultracet^{(R)}$, respectively (P=0.003). Regarding the quality of life, only mood changed for the better in 49 patients who were treated with $Ultracet^{(R)}$ alone ($1.98{\pm}1.73\;and\;1.35{\pm}1.15$, before and after treatment respectively; P=0.046). There were five (8.2%) adverse events associated with $Ultracet^{(R)}$ treatment. Conclusion: $Ultracet^{(R)}$ seems effective and safe in ambulatory patients with cancer pain.

  • PDF

The study of Breast Specific Gamma Imaging Protocol using Self-development Phantom (자체 제작된 팬텀을 적용한 Breast Specific Gamma Imaging 검사 프로토콜에 대한 고찰)

  • Lee, Hae-Jung;Lee, Juyoung;Lim, Kuen-Kyo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.39-47
    • /
    • 2014
  • Purpose As breast cancer patients continue to increase every year, cases of BSGI are on the rise with a heavier reliance on it. However, BSGI protocol in hospitals was not studied enough despite it was covered by hospital's condition and recommendation of manufacturers. The objective of the study was an examination of methods to be applicable to BSGI protocols, putting the self-development phantom to use in quality assessment of the images. Materials and Methods Dilon 6800 (Dilon Technologies Inc, Newport News, USA) was used in the study and five different sizes of sphere were distinctively produced in the phantom. The study used $^{99m}TcO_4$. The cases were classified in to three categories that background radioactivity to region of interest as ratio of 2: 4: 8, They were acquired images for 5, 7, 10mins. The acquired image was set region of interest according to the size of sphere, and We analyzed quantitative and qualitative analysis. The acquired data statistically analyzed with SPSS ver.18.0. Results As the result of quantitative and qualitative analysis, count rate of each sphere in accordance with difference of injection dose showed that higher count rate as injection dose and sphere size increased (P<0.005). Count rate of each sphere in accordance with difference of acquisition time showed that higher count rate as acquisition time and sphere size increased (P<0.005). Contrast noise ratio of each sphere in accordance with difference of injection dose showed that higher contrast noise ratio as injection dose increased. Particularly, Contrast noise ratio of eight times ratio images was the highest among. Contrast noise ratio of each sphere in accordance with difference of acquisition time showed that higher contrast noise ratio as acquisition time increased. And, Contrast noise ratio of seven minute image was the highest among (P<0.005). Conclusion There was significant change of Contrast noise ratio through quantitative and qualitative analysis. Moreover, We found usefulness of phantom. If Institutions identified image through the phantom study and they made BSGI protocol, We expected to help the improvement of diagnostic value of the images.

  • PDF

Using CR System at the Department of Radiation Oncology PACS Evaluation (방사선 종양학과에서 CR System을 이용한 PACS 유용성 평가)

  • Hong, Seung-Il;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.143-149
    • /
    • 2012
  • Today each hospital is trend that change rapidly by up to date, digitization and introducing newest medical treatment equipment. So, we introduce new CR system and supplement film system's shortcoming and PACS, EMR, RTP system's network that is using in hospital harmoniously and accomplish quality improvement of medical treatment and service elevation about business efficiency enlargement and patient Accordingly, we wish to introduce our case that integrate reflex that happen with radiation oncology here upon to PACS using CR system and estimate the availability. We measured that is Gantry, Collimator Star Shot, Light vs. Radiation, HDR QA(Dwell position accuracy) with Medical LINAC(MEVATRON-MX) Then, PACS was implemented on the digital images on the monitor that can be confirmed through the QA. Also, for cooperation with OCS system that is using from present source and impose code that need in treatment in each treatment, did so that Order that connect to network, input to CR may appear, did so that can solve support data mistake (active Pinacle's case supports DICOM3 file from present source but PACS does not support DICOM3 files.) of Pinacle and PACS that is Planning System and look at Planning premier in PACS. All image and data constructed integration to PACS as can refer and conduct premier in Hospital anywhere using CR system. Use Dosimetry IP in Filmless environment and QA's trial such as Light/Radition field size correspondence, gantry rotation axis' accuracy, collimator rotation axis' accuracy, brachy therapy's Dwell position check is available. Business efficiency by decrease and so on of unnecessary human strength consumption was augmented accordingly with session shortening as that integrate premier that is neted with radiation oncology using CR system to PACS. and for the future patient information security is essential.

Comparison of Digital Mammography and Digital Breast Tomosynthesis (디지털 유방촬영기기와 3차원 디지털 유방단층영상합성기기의 비교연구)

  • Kim, Ye-Seul;Park, Hye-Suk;Choi, Jae-Gu;Choi, Young-Wook;Park, Jun-Ho;Lee, Jae-Jun;Kwak, Su-Bin;Kim, Eun-Hye;Kim, Ju-Yeon;Jung, Hyun-Jung;Lee, Haeng-Hwa;Bae, Gyu-Won;Lee, Mi-Young;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.261-268
    • /
    • 2012
  • Breast cancer is the second leading cause of women cancer death in Korea. The key for reducing disease mortality is early detection. Although digital mammography (DM) has been credited as one of the major reasons for the early detection to decrease in breast cancer mortality observed in the last 20 years, DM is far from perfect for several limitations. Digital breast tomosynthesis (DBT) is expected to overcome some inherent limitations of conventional mammography caused by overlapping of normal tissue and pathological tissue during the standard 2D projections for the improved lesion margin visibility and early breast cancer detection. In this study, we compared a DM system and DBT system acquired with different thickness of breast phantom. We acquired breast phantom data with same average glandular dose (AGD) from 1 mGy to 4 mGy under same experimental condition. The contrast, micro-calcification measurement accuracy and observer study were conducted with breast phantom images. As a result, the higher accuracy of lesion detection with DBT system compared to DM system was demonstrated in this study. Furthermore, the pain of patients caused by severe compression can be reduced with DBT system. In conclusion, the results indicated that DBT system play an important role in breast cancer detection.

Comparison Evaluation of Image Quality with Different Thickness of Aluminum added Filter using GATE Simulation in Digital Radiography (GATE 시뮬레이션을 사용한 알루미늄 부가필터 두께에 따른 Digital Radiography의 영상 화질 비교 평가)

  • Oh, Minju;Hong, Joo-Wan;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.81-86
    • /
    • 2019
  • In X-ray image, the role of filtration through the filter is to reduce the exposure of the patient by using photon which is useful in formation of the image, and at the same time, enhance the contrast of the image. During interaction between photon and object, low energy X-rays are absorbed from the site of a few cm of the first patient's tissue, and high energy X-rays are the one which form the image. Therefore, the radiation filter absorbs low energy X-ray in order to lower the exposure of the patient and improve the quality of the image. The purpose of this study is to compare the effect on the image quality by differences of added filter through simulation image and actual radiation image. For that purpose, we used Geant4 Application for Tomographic Emission (GATE) as a tool for Monte Carlo simulation. We set actual size, shape and material of Polymethylmethacrylate (PMMA) Phantom on GATE and differentiated the parameter of added filter. Also, we took image of PMMA phantom with same parameter of added filter by digital radiography (DR). Than we performed contrast-to-noise ratio (CNR) evaluation on both simulation image and actual DR image by Image J. Finally, we observed the effect on image quality due to different thickness of added filter, and compared two images' CNR evaluation's transitions of change. The result of this experiment showed decreasing in the progress of CNR on both DR and simulation image. It is ultimately caused by decreasing in contrast on image. In theory, contrast decrease with kVp increased. Given that condition, this study found out that filter makes not only decreasing total dose by absorbing low energy of X-ray, but also increasing average energy of X-ray.