• Title/Summary/Keyword: 환경부하 값

Search Result 276, Processing Time 0.036 seconds

Evaluations of Life Cycle Assessment on Indium-Tin-Oxide Electrochemical Recycling Process (디스플레이 투명전극용 인듐-주석-산화물의 전기화학적 재활용 공정에 관한 전과정 평가)

  • Kim, Raymund K.I.;Lee, Na-Ri;Lee, Soo-Sun;Lee, Young-Sang;Hong, Sung-Jei;Son, Young-Keun;Hong, Tae-Whan
    • Clean Technology
    • /
    • v.19 no.4
    • /
    • pp.388-392
    • /
    • 2013
  • Iindium-tin-oxide (ITO) material was had to use in display application as transparent electrode. However it would be problems comes up, the depletion of indium, tin and energy consumption of production process. Therefore recently trend was demanded alternative ITO material and recycling/reused ITO. In this conditions, the environmental impact have to express correct value about recycling/reused ITO process. The life cycle assessment was valuable method in this process. Thus first step was carried out separating in/out put (material) sources and then, exactive data base (DB) was applied. The result of environment impact was calculated by affect categories and recycling rate was set to 34% (This value was measured in previous project). The rate (g) of ITO material was calculated by chemical equivalent. In result, environmental impact were revealed acidification potential and abiotic depletion and if do not recycle/reuse ITO, $ 476 per 1 ton waste in land.

Environmental Impact Assessment in LCA Using Analytic Network Process (네트워크구조 의사결정기법을 이용한 LCA 환경영향평가)

  • 강희정
    • Journal of Energy Engineering
    • /
    • v.8 no.4
    • /
    • pp.612-620
    • /
    • 1999
  • Environmental impact assessment in the step of the Life Cycle Assessment (LCA) measures relative values of importance or weight of the environmental load characterized in the inventory analysis. The weight measurements are used to evaluate the environmental load or the effect of the industrial product or technology. In this paper the Analytic Network Prpcess (ANP) is introduced to calculate a relative weighting of the environmental impact. The ANP is considered as one of the useful decision making framework and allow for more complex interrelationships, feedback, and inner/outer dependence among the decision level and factors. The weighting from the ANP may applied to obtain the overall evaluation value of environmental load.

  • PDF

핵융합로 부품에 대한 고열유속 시험조건 결정

  • Bae, Yeong-Deok;Lee, Dong-Won;Kim, Seok-Gwon;Yun, Jae-Seong;Hong, Bong-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.273-273
    • /
    • 2010
  • 고열부하 환경에 노출되는 핵융합로의 플라즈마 대향부품은 주로 낮은 원자번호 물질-열전도가 좋은 물질-구조체의 순으로 다층 구조를 이루고 있으며, 이들 간의 우수한 접합성은 부품의 성능을 좌우하는 핵심 요소이다. 이러한 플라즈마 대향부품의 건전성을 평가하기 위해서는 고열속의 열부하를 반복적으로 인가하는 시험이 요구되며, 이를 위해 본 연구원에서는 KoHLT-1, 2의 시험시설을 운용하고 있다. 본 시설에서는 열부하원으로서 그라파이터 히터를 사용하며, 히터는 두 개의 시험 대상부품 사이에 설치되고, 히터에 고전류를 인가하여 복사열에 의해 시험 부품에 열부하를 가하게 된다. 고열부하 환경에서 열피로 시험을 위해 히터에 인가되는 전류를 시간에 따라 일정한 패턴으로 반복적으로 ON-OFF 하게 된다. 본 논문에서는 이러한 고열부하시험을 수행함에 있어 고려해야 할 여러 가지 요소에 대해 논의하였다. 우선 인가하는 열유속(heat flux) 값은 일차적으로 시험시설의 최대 출력에 의해 좌우되며, 시험대상물의 운전조건 및 열부하 반복횟수에 의해 결정된다. 열부하 반복횟수는 주어진 열유속 값에 대해 total strain이 파단에 이르는 수준에 의해 결정된다. 열부하를 인가하는 시간은 히터에 전류를 인가했을 때 요구되는 온도로 상승하는 데 걸리는 시간과 시험대상물의 온도가 더 이상 증가하지 않는데 걸리는 시간에 의해 좌우된다. 냉각시간은 길수록 시험대상물의 온도가 냉각수의 온도에 접근하게 되나 너무 길어지면 시험시간이 급격히 증가하게 되므로, 온도 감소 곡선을 검토하여 적절한 시간을 정하게 된다. 열유속 측정은 냉각수의 온도 상승값과 유량으로부터 계산하게 되며, 정확한 측정을 위해서는 열부하를 인가하는 시간이 충분히 길어야 한다. 또한 시험대상 부품에서 열부하가 인가되는 면적을 정확히 정의해야 하며, 냉각관로에 열부하가 인가되어서는 않된다. 또한 시험대상부품을 지지하는 지지구조체를 통한 열손실을 최소화해야 정확한 열유속을 측정할 수 있다. 시험대상부품을 설치할 때 히터와의 간격 또한 결정해야 할 중요한 요소이며, 간격이 좁을수록 최대 열유속 값을 증가시킬 수 있으나, 너무 가까운 경우 히터의 열변형에 의한 접촉 및 아크 방전의 가능성이 있으며, 이 경우 히터와 시험대상부품의 손상을 가져오게 된다. 시험대상물이 국제열핵융합로(ITER)의 일차벽과 같이 베릴륨이 포함되어 있는 경우 방전에 의한 손상은 인체에 유해한 오염의 원인이 될 수 있다. 또한 순간적인 방전은 고가의 고전류전원의 고장을 유발할 수도 있다. 열부하 시험 중 시험대상물의 온도를 정확히 측정하는 것은 필수적이며, 온도 변화 곡선으로부터 시험대상물의 건전성 여부를 판단할 수 있다. 이를 위해 변화를 가장 잘 탐지 할 수 있는 위치에 온도 센서를 설치하는 것이 관건이며, 이는 사전 분석을 통해 알 수 있다.

  • PDF

Estimate of the relationship between discharge and pollution loads at Kyungan on a rainy season (경안 지점의 강우기 유량과 오염부하량 관계 분석)

  • Kim, Kyung-Hee;Lee, Yeon-Kil;Lee, Jin-Won;Jung, Sung-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.1991-1994
    • /
    • 2008
  • 우리나라는 도시화, 산업화에 따른 수질저하 및 용수확보 문제를 해결하기 위하여 각종 환경기초시설의 증설과 수질개선을 위한 대책을 수립하여 왔다. 그러나 점오염원에 국한한 수질개선은 한계가 있었으며, 1995년 환경부는 전국 비점오염원 조사를 통해 비점오염원이 수질오염에 기여하는 비율이 T-N, SS는 50% 이상을 점유하고 기타 BOD, T-P도 $20{\sim}30%$ 수준임을 밝힌 바 있다. 이에 정부는 오염총량관리제를 도입하여 비점오염원의 관리를 시작하였으나, 강우시 정확한 유량자료를 바탕으로한 수질 측정자료의 부족으로 비점오염원 관리에 있어 어려움이 따르고 있다. 따라서 본 연구에서는 비점오염원 관리 및 연구를 위한 기초자료로 활용될 수 있도록 수도권 및 인근지역 주민의 식수원인 팔당호로 직유입되고, 정확한 수질자료 확보가 필요한 경안 수위관측소 지점에서 2007년 6월${\sim}$9월에 일어난 강우 중 4개의 강우사상에 대하여, 수질측정을 실시하였다. 본 연구에서 이용한 유량자료는 2007년 수위-유량관계곡선식으로 산정한 환산 유량이며, 실측한 수질자료를 바탕으로한 유량과 부하량의 관계는 통계학적으로 분석하였다. 수질측정 항목은 수온, DO, pH, EC, SS, BOD, CODMn, CODCr, T-N, T-P 등이며, BOD의 농도는 2개의 강우사상에서만 분석하였다. 현장에서 휴대용미터를 이용하여 수온, DO, pH, EC를 측정하였고, 나머지 항목은 한국건설기술연구원내 환경정밀분석 센타에 의뢰하였다. 각 항목별 유량-부하량 관계식은 기존의 지수식이 아닌 선형이나 다항식으로 산정하였다. 다항식으로 산정된 식의 결정계수($R^2$)는 BOD, T-N 항목을 제외한 각 항목에서 0.6 이상의 값을 가졌다. 항목별로 보면 SS는 0.90, $COD_{Mn}$은 0.87, $COD_{Cr}$은 0.84, T-P는 0.62의 값을 가졌다. 또한, T-N은 0.53, BOD는 0.32의 값을 가져 유량과 부하량의 관계가 거의 상관성이 없는 것으로 나타났다. BOD의 경우는 4개의 강우사상 중 2개의 강우사상에서만 분석되어 다른 항목에 비해 실측자료가 부족한 관계로 그 특성을 판단하기 어려웠다. 본 연구가 주로 홍수기에 이루어져 실측자료가 많지 않았기 때문에 본 연구의 대상지점을 대표할 수 있는 유량-부하량 관계식으로는 미흡한 한 것으로 분석되었다. 본 연구자료를 기초로 장기간 많은 자료를 확보하여 유량-부하량 관계식을 수정 보완한다면, 차후 비점오염원 관리의 기초자료로 활용될 수 있을 것으로 판단된다.

  • PDF

Comparison of Waste-Plastic Recycling Methods for Environmental Assessment (환경성 평가를 위한 폐플라스틱 재활용 방법들의 비교)

  • Park, Chan-Hyuk;Choi, Suk-Soon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.14 no.2
    • /
    • pp.101-111
    • /
    • 2006
  • In the present work, life cycle assessments (LCA) of various waste-plastic recycling methods (material recycling, refused derived fuel (RDF), recycling on furnace, and pyrolytic oil production) were carried out to investigate their impacts on the environment. Six types of impacts were considered. While the impact on global warming was found to be significant, the impact on others were negligible. The impact values on the global warming caused by the material recycling, RDF, and the recycling on furnace were negative, which implied that their impacts could be noticeably reduced when waste-plastic are used as an alternative to newly drawn plastics. The pyrolytic oil production, however, showed positive value, which may be due to the carbon dioxide produced during electric power generation. The pyrolytic oil production had the largest impact on the ozone layer destruction, which was due to ozone depleting substances produced from the process itself. These results can be used as a useful data for the enhancement of waste-plastic recycling.

  • PDF

Balancing the Load of Web Server and Improving Network Performance by Control1ing RTO Value (웹 서버의 부하 분산과 RTO (Retransmission Time-Out) 값 조정를 통한 네트워크 이용율 향상)

  • 김진희;한설흠;권경희
    • Proceedings of the KAIS Fall Conference
    • /
    • 2002.11a
    • /
    • pp.220-224
    • /
    • 2002
  • 본 논문에서는 웹 서버의 부하가 급증하면서 대두된 네트워크 과부하를 해결하기 위한 방법으로 서버분산처리 방식과 RTO(retransmission time out : 재전송타임아웃)간을 조정하는 기법을 이용하였다. 부하 분산을 위한 방법으로는 기존의 NAT 기반의 가상서버 방식과 비슷하나, 기존의 가상서버에서 서버들을 선택하는 스케줄링 방법을 이용하지 않고 네트워크 주소(IP)룰 통한 서버 분산방법을 선택하였다. 이를 위해 Linux 기반의 PC에 라우터론 구축하였고 여기에 실제 IP를 할당하였으며, 라우터를 경유하여 연결된 두개의 서버에는 가상 IP를 할당 내부접속용과 외부접속용으로 나누어 서버 분산이 이루어지게끔 하였다. 이러한 서버 분산은 학교라는 즉. 웹서버의 접속이 내부접속 비율과 외부접속 비율 어느 한쪽으로도 크게 기울지 않는 네트워크 환경을 고려한 것이다. 네트워크의 성능 평가에 있어 가장 기본이 될 수 있는 응답시간은 전송거리와 트래픽량에 비례한다. 이에 외부접속용 서버와 내부접속용 서버 각각에 RTO 값을 다르게 적용시킴으로써 전체적인 Delay의 변화를 확인해 볼 수 있다. 이는 전송거리가 길 경우 생길 수 있는 패킷 손실을 고려한 것으로 패킷 손실로 인하여 재전송이 이루어질 경우 재전송 time이 RTO를 통하여 이루어지며 이러한 RTO의 적절한 값은 전체적인 응답시간에 영향을 미칠 수 있다는 것에 기인한 것으로 RTO값을 전송거리가 긴 외부접속용 서버에는 전송거리가 짧은 내부접속용 서버에 비해 길게 적응시킴으로써 전체적인 응답시간의 개선을 유도하였다

Effect of Major Tributaries Water Quality Improvement in the Geum River Area, Korea using EFDC Model (EFDC 모델을 이용한 금강 주요 지류의 수질개선 효과)

  • Kim, Jin soo;Kim, Ja young;Seo, Dong il
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.266-266
    • /
    • 2019
  • 금강의 주요 지류인 미호천과 갑천은 대전광역시와 청주시가 위치하고 있으며, 두 도시지역에서 유입되는 오염물질로 인하여 금강 본류에 높은 오염부하를 제공하고 있다. 따라서 본 연구에서는 3차원 수리동역학 모델인 EFDC 모델을 사용하여 미호천과 갑천의 수질개선이 금강의 수질에 미치는 효과를 분석하였다. 대상유역은 대청댐부터 백제보 까지 70km 구간이며, 모델의 격자는 Curvilinear-Orthogonal Coordinate를 사용하였으며 횡단방향 8개로 분할하여 총 6,698개의 격자로 구성하였다. 경계조건구성 및 모델의 보정은 국가정보 포털인 수자원관리종합정보시스템(WAMIS), 물환경정보시스템(WEIS), 국가기후데이터센터(data,kma,go,kr) 등에서 제공하는 유량, 수질, 기상 등 데이터를 활용하였으며, 모의 기간은 2017년이다. 수질의 보정은 대상유역 내 6곳의 수질 측정 지점에서 수행되었으며, 적합성 평가를 위해 R-square와 NSE(Nash-Sutcliffe Efficiency) 두 가지의 통계 지표를 활용하였다. 수질의 경우 TN, TP, TOC, Chl-a 순으로 평균 R-square값은 0.75, 0.51, 0.36, 0.57이고 평균 NSE (Nash-Sutcliffe Efficiency)값은 0.59, -0.18, -1.10, 0.27으로 모의 값과 실측값 사이의 상관관계는 TN에서 가장 높았으며 반대로 TOC는 가장 낮았다. 모의결과가 실측값을 정확히 반영하지는 못했지만, 수질의 평균적인 현상은 반영한 것으로 판단된다. 두 주요 지류의 수질이 동시에 15% 또는 30% 개선되었을 경우를 모의하여 금강 본류의 수질변화를 6곳의 수질 측정 지점에서의 실측값과 비교하여 분석하였다. 두 지류가 동시에 15%의 수질 개선 시에는 금강 본류 수질은 TN, TP, TOC, Chl-a 순으로 평균 11.80%, 7.90%, 8.63%, 7.04%의 개선되었으며, 30% 수질 개선 시에는 평균 23.66%, 15.92%, 17.36%, 14.26%의 개선되었다. 각 지점에서 고른 개선이 확인되었으며, 개선 효과는 TN이 가장 컸고, 반대로 Chl-a가 가장 적었다. 갑천과 미호천의 수질이 별개로 개선되었을 경우를 모의한 결과, 미호천의 개선이 갑천에 비해 금강의 수질 개선에 영향이 컸다. 이는 두 지류의 수질 농도는 비슷하나 갑천에 비해 유량이 많은 미호천의 오염 부하량이 높은 것으로 분석된다. 연구 결과 금강의 수질을 개선하기 위해서는 두 지류의 수질 개선이 필수적인 것으로 판단된다. 금강의 TN 농도는 두 지류의 영향이 가장 컸으며, 개선 효과는 Chl-a에서 가장 적었다. 또한 갑천에 비해 미호천이 금강 수질에 영향이 큼을 확인하였다.

  • PDF

Assessment of impact on Pollution load in First-flush Overflows in Jungnangcheon (초기우수월류가 중랑천 오염부하량에 미치는 영향 평가)

  • Shin, Jea Whan;Jang, Suk Hwan;Jo, Jun Won;Park, Seung Ju
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.334-334
    • /
    • 2020
  • 우리나라는 서울지역과 수도권 위성도시의 인구분포가 집중되어있으며, 도시지역에 대한 관거 우선 확충에 따라 하수처리구역의 비율이 점차 늘어나고 있다. 초기우수월류에 의한 오염은 비점오염원의 경우로, 발생 및 배출경로가 다양하고 불특정하게 발생한다. 비점 오염원의 유출 농도는 강우 초기에 높게 나타나고, 점차 농도가 낮아지는데, 이러한 강우 특성을 고려하여 오염발생량을 규명하는 것이 필요하다. 이에 따라 본 연구에서는 중랑천 의정부 지역을 대상지역으로 선정하여, 합류식 하수관거 월류부하를 하수도법 관리수준으로 제어하기 위한 초기우수 처리대상 강우량을 산정하고 강우분포형 및 토지이용도 현황별로 초기월류유량 및 부하특성을 검토하였다. 본 연구에서는 SWMM(Strom Water Management Moder)모형을 적용하여, 매년 홍수기에 발생할 수 있는 다양한 강우분포를 고려하여 대상유역의 토지용도별 합류식 처리구역에 대하여 SWMM 모형의 검·보정 절차를 통해 예측값과 측정값 사이의 상관관계를 분석하였고, 의정부 지역의 초기우수월류 오염부하량의 토지용도에 따른 경향성과, 강우량 및 강우분포, 배수면적에 따른 경향성을 비교하였다.

  • PDF

Sensor Data Allocation using Support Vector Machine in Distributed-Gateway System (분산 게이트웨이 환경에서의 Support Vector Machine을 이용한 센서 데이터 할당)

  • Lee, Tae-Ho;Yoo, Seung-Eon;Lee, Byung-Jun;Kim, Kyung-Tae;Youn, Hee-Yong
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2018.07a
    • /
    • pp.199-200
    • /
    • 2018
  • 본 논문에서는 IIoT(Industrial IoT) 환경의 분산 게이트웨이 시스템(Distributed-Gateway System)에서 사용되는 수 천 개 이상의 센서에서 데이터 전송을 받는 각 게이트웨이의 데이터 처리 속도를 향상시키고 작업 오류를 줄이기 위하여 SVM(Support Vector Machine) 알고리즘을 사용한 센서 데이터 할당 기법을 제안한다. 각 센서의 반복 측정 간격과 중요도에 따라 작업부하(Workload)를 구하고, 이를 순차 반복 비교를 통해 Sub-task 값을 구한다. 이렇게 구해진 Sub-task값을 기준으로 각 게이트웨이에 할당시킴으로써 신뢰성과 정확성, 신속성을 확보한다.

  • PDF

Estimation of MFFn for Paddy fields (논지역의 초기세척비율(MFFn) 산정)

  • Choi, Dong Ho;Yoon, Kwang Sik;Baek, Sang Soo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.542-542
    • /
    • 2015
  • 비점오염원은 기상조건과 토지이용에 따라 시간에 따른 오염부하량의 변동폭이 크게 발생하며, 강우초기에 오염물질의 농도가 크게 나타난다. MFFn은 강우지속시간에 따라 다양하게 변화하는 오염물질의 부하량과 유출량을 특정시점에서 강우유출율과 오염물질 유출율을 계산할 수 있으며, 강우가 시작될 때 0, 종료될 때 1의 값을 나타내며, 1보다 크면 초기세척이 있음을 나타낸다. 예를 들면 MFF20에서 평균값이 2.5이면 초기우수유출수의 부피 20%에 오염물질 부하량의 부피 50%를 포함하는 것을 의미한다. 본 연구에서는 논에서의 초기세척비율 정량화하기 위해 영산강수계 논지역(이하, 학야지구)과 섬진강수계 논지역(이하, 적성지구) 각 1개유역을 선정하여 2009년부터 2012년까지 수문 및 수질 모니터링을 수행하였다. 유역면적은 학야지구는 13.69 ha 이며, 적성지구는 8.06ha 이다. 두 지역 모두 외부유입이 없으며, 배수로가 구조물화 되어 있어 관측이 용이한 지점이다. 논에서 강우시유출되는 오염물질을 산정하기 위해서 배수로 말단에 압력식 수위계와 자동채수기를 설치하여 일정간격으로 관측하였으며, 수위별 유량관측을 통해 수위-유량관계곡선식을 산정 후 유량으로 환산하였다. 채취된 수질은 수질공정시험법을 통해 BOD, COD, TOC, T-N, T-P, SS를 분석하였으며, 관측된 유량과 수질자료를 이용하여 부하량을 산정하고, MFFn을 이용하여 초기세척비율을 정량화 하였다. BOD COD, TOC, T-N, T-P, SS 의 논 초기세척비율은 n 값이 10% 때 중앙값이 각각 1.3, 1.18, 1.13, 1.2, 1.13, 1.1 였으며, 13%, 11.8%, 11.3%, 12%, 11.3%, 11% 가 유출되는 것으로 나타났으며, n 값이 20%일 때 1.3, 1.1, 1.1, 1.25, 1.2, 1.2 이였으며, 26%, 22%, 22%, 25%, 24%. 24%가 유출되는 것으로 나타났다. n 값이 30%일 때 1.25, 1.0, 1.0, 1.25, 1.13, 1.3 였으며, 37.5%, 30%, 30%, 37.5%, 33.9%, 39%가 유출되는 것으로 나타났다.

  • PDF