• Title/Summary/Keyword: 환경권

Search Result 3,953, Processing Time 0.032 seconds

Spatial and Temporal Variations of Environmental Factors and Phytoplankton Community in Lake Yongdam, Korea (용담호에서 환경요인과 식물플랑크톤의 시공간적 변동)

  • Kwon, Sang-Yong;Kim, Young-Geel;Yih, Won-Ho;Lim, Byung-Jin;Kim, Bom-Chul;Heo, Woo-Myung
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.3 s.117
    • /
    • pp.366-377
    • /
    • 2006
  • Environmental gradients and phytoplankton community were studied on a monthly basis, at 3 stations of Lake Yongdam, from April 2002 March 2004. During July to August, thermocline formed at the depth of about 10 m, but it was lowerd depth, in between 25${\sim}$30 m in October. Monthly variations of the epilimnetic (0${\sim}$5 m) TP concentrations at station 1, 2 and 3 were in the range of $5.1{\sim}36.1\;mg\;P\;{\cdot}\;m^{-3}$, $6.1{\sim}77.7\;mg\;P\;{\cdot}\;m^{-3}$ and $6.7{\sim}47.7\;mg\;P\;{\cdot}\;m^{-3}$ respectively; with higher concentrations at the upstream areas showing. Monthly average of the epilimnetic (0${\sim}$5 m) TN concentration at Station 1 was in the range of $0.88{\sim}1.73\;mg\;N\;{\cdot}\;L^{-1}$, and Station 3 was in the range of $0.94{\sim}2.77\;mg\;N\;{\cdot}\;L^{-1}$, which is higher if compared with the values of station 1. Transparency wa:s in the range of 0.8${\sim}$6.7 m, with lower values at upstream areas and higher at the downstream area. As for phytoplankton, during the winter season, diatoms had high appearance rate; during the spring season, Cyclotella comta, Aulacoseira ambigua f. spiralis, A. granulata and similar diatoms, during spring and summer Ankistrodesmus spiralis, Chodatella subsala, Crucigenia irregularis, Coelastrum cambricum, Scenedesmus ecornis v. ecornis.

Geochemical Studies of Geothermal Waters in Yusung Geotheraml Area (유성 지역 지열수의 지구화학적 특성 연구)

  • 김건영;고용권;김천수;배대석;박맹언
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.7 no.1
    • /
    • pp.32-46
    • /
    • 2000
  • Hydrogeochemical and isotope ($\delta$$^{18}$ O, $\delta$D, $^3$H, $\delta$$^{13}$ C, $\delta$$^{34}$ S, $^{87}$ Sr/$^{86}$ Sr) studies of various kinds of waters (thermal groundwater, deep groundwater, shallow groundwater, and surface water) from the Yusung area were carried out in order to elucidate their geochemical characteristics such as distribution and behaviour of major/minor elements, geochemical evolution, reservoir temperature, and water-rock interaction of the thermal groundwater. Thermal groundwater of the Yusung area is formed by heating at depth during deep circlulation of groundwater and is evolved into Na-HCO$_3$type water by hydrolysis of silicate minerals with calcite precipitation and mixing of shallow groundwater. High NO$_3$contents of many thermal and deep groundwater samples indicate that the thermal or deep groundwaters were mixed with contaminated shallow groundwater and/or surface water. $\delta$$^{18}$ O and $\delta$D are plotted around the global meteoric water line and there are no differences between the various types of water. Tritium contents of shallow groundwater, deep groundwater and thermal groundwater are quite different, but show that the thermal groundwater was mixed with surface water and/or shallow groundwater during uprising to surface after being heated at depths. $\delta$$^{13}$ C values of all water samples are very low (average -16.3$\textperthousand$%o). Such low $\delta$$^{13}$ C values indicate that the source of carbon is organic material and all waters from the Yusung area were affected by $CO_2$ gas originated from near surface environment. $\delta$$^{34}$ S values show mixing properties of thermal groundwater and shallow groundwater. Based on $^{87}$ Sr/$^{86}$ Sr values, Ca is thought to be originated from the dissolution of plagioclase. Reservoir temperature at depth is estimated to be 100~1$25^{\circ}C$ by calculation of equilibrium method of multiphase system. Therefore, the thermal groundwaters from the Yusung area were formed by heating at depths and evolved by water-rock interaction and mixing with shallow groundwater.

  • PDF

A study on the Development of a Drying and Fermentation Process of Domestic Animal Manure;II. Demonstration of a Pig Manure Treatment System on a Farm (가축분(家畜糞) 건조(乾燥) , 발효(醱酵) 복합시설(複合施設) 개발(開發) 연구(硏究);II. 돈분(豚糞) 건조(乾燥), 발효(醱酵), 복합시설(複合施設) 실증시험(實證試驗))

  • Yun, Sun-Gang;Jung, Kwang-Yong;Park, Woo-Kun;Kwon, Sun-Ik;Park, Hong-Jae;Yoo, Sun-Ho
    • Korean Journal of Environmental Agriculture
    • /
    • v.13 no.2
    • /
    • pp.223-230
    • /
    • 1994
  • A practical study on a drying and fermentation system equipped with a stirring machine operated mechanically, of pig manure was conducted to prove the efficiency of and practicability to an ordinary pig farm. The type of the drying bed was a round-shaped (r=3m) concrete structure and the stirring machine was adopted to stir and transfer dried pig manure to the fermentation tank. The dried pig manure was put into a fermentation tank ($V=18m^3$), which was aerated from pipe lines installed at the bottom. While water content of pig manure passing through a drying bed was remarkably reduced than before drying, the drying efficiency of this system decreased in winter. However, the temperature of pig manure piled up in the fermentation room in winter reached over $60^{\circ}C$ and excess water of pig manure was removed during the fermentation process. The reduction rate of water content of pig manure, to which dried pig manure was added as bulking material on the drying bed, was 52.1%, but when dried without bulking material it was only 19.7%. Although the content of $P_2O_5$ of dried pig manure was slightly higher than that of fresh pig manure, progressive changes in chemical composition between fresh and dried pig manure made no great difference. Among the contents of minerals of fresh and dried pig manure, CaO was the highest and the rest were in the decreasing order of $K_2O$, MgO, and $Na_2O$. Population density of E. coli and Streptococci of dried pig manure was reduced by 142 and 236 times that of fresh pig manure, respectively. The installation cost of this drying and fermentation system was 4,185,630 won (approximately 5,232 US $) and operating cost per year was 190,000 won (237.5US $) on the basis of self-labor condition.

  • PDF

Characteristics of Non-point Pollutants Discharge in a Small Agricultural Watershed during Farming Season (영농기 농촌 소유역의 비점오염물질 유출 특성)

  • Kim, Jin-Ho;Lee, Jong-Sik;Ryu, Jong-Su;Lee, Kyung-Do;Jung, Goo-Bok;Kim, Won-Il;Lee, Jeong-Taek;Kwun, Soon-Kuk
    • Korean Journal of Environmental Agriculture
    • /
    • v.24 no.2
    • /
    • pp.77-82
    • /
    • 2005
  • This study was conducted to identify the characteristics of non-point pollutants discharge in a small agricultural watershed during farming season. for this purpose, the Neoungchon watershed in Goesangun was selected as a typical agricultural area. Runoff and water quality data in the stream, the domestic sewage and the precipitation of the watershed were analyzed periodically from June 1 to November 6 in 2004 and pollutant loads were estimated. As a result the mean concentrations of BOD, SS, TN and TP in the stream were 3.0, 76.7, 8.7, 0.16 mg/L in rainy season and 2.4, 10.0, 3.5, 0.11 mg/L in dry season respectively. Daily discharge of non-point pollutant occurred above of 95% in rainy period. Measured pollutant loads in the watershed were $26.63kg/km^2/day$ of T-N and $0.62kg/km^2/day$ of T-P, within the range of other research results. Effluent loads based on guideline of total pollutant to stream management of MOE (Ministry of Environment) were less than delivery loads since the guideline could not reflect the agricultural practices, geomorphic and meteorological characteristics in an agricultural watershed.

A Study on the Characteristics of Water Pollution in Rural Areas (농촌유역(農村流域)에서의 수질오염(水質汚染) 특성(特性)에 관한 연구(硏究))

  • Kim, Han-Tea;Kwun, Soon-Kuk
    • Korean Journal of Environmental Agriculture
    • /
    • v.12 no.2
    • /
    • pp.129-143
    • /
    • 1993
  • The objective of this study is to understand the status of the water pollution in rural areas and to furnish a basic material for the management of the water pollution in rural areas. For this purpose, the Bokha river basin, Ichon-Gun, Kyungki-Do considering as a typical agricultural area was selected as a representative experimental watershed. The characteristics of water pollution in streams of the Bokha river basin was revealed by investigating and analyzing data collected for the source of pollution, water qualities in reaches of the stream, the degree of contribution to the river contamination by pollution mass produced from each source, and the status of the self-purification at the main stream. The most important source of the water pollution in investigated watershed was livestock, and the next important one were in the order of population, land use, and industry. The water quality of the Bokha river was relatively favorable judging from the BOD and COD concentration, however since the concentration of T-N and T-P showed significantly large values, it was concluded that the river was seriously contaminated by the nutrient material. The main cause of the river contamination was proved due to livestock waste. For the T-N, both land use and livestock were much more contributied to the pollution than any other source, which characterized the typical water pollution of rural areas. Run-off ratios for the Bokha river tributaries to the main stream were changed according to the similar trend to the variation of discharges in the branch streams. For the value of the self-purification constant at the main stream, it showed smaller value in the downstream reach than the middle-stream and upstream reaches, where could possibly have smaller reoxidation action due to slower velocity and deeper water depth.

  • PDF

Repellent and Insecticidal Activity of Sequential Extracting Fractions Obtained from BPH-Resistant Rice Varieties against Brown Planthopper (Nilaparvata lugens) (벼멸구 저항성벼 품종 추출분획물의 기피 및 살충 활성)

  • Kim, Sung-Eun;Kim, Young-Doo;Kim, Bo-Kyoung;Ko, Jae-Kwon;Chun, Jae-Chul
    • The Korean Journal of Pesticide Science
    • /
    • v.10 no.2
    • /
    • pp.124-130
    • /
    • 2006
  • Rice plant extracts of brown planthopper (BPH) resistant rice varieties, Jangseongbyeo (JSB) and Hwacheongbyeo (HCB) at different growth stages (seedling, tillering, heading and ripening) were sequentially fractioned using hexane, ethyl ether, ethyl acetate, butanol, and distilled water. The extracts were applied to BPH susceptible rice variety, Dongjjnbyeo (DJB), to investigate the insecticidal and repellent effects against BPH. BPH insecticidal effects were not clearly observed with almost all of the extract fractions obtained from both JSB and HCB varieties for 12 h, whereas the ethyl ether and hexane extract fractions showed about 10 to 30% of BPH mortality in 24 to 48 h of application periods. An effective BPH repellent activity was found with the applications of ethyl ether extract fractions obtained from JSB variety. The extract fractions obtained from HCB variety did not show any different repellence among the various fractions. The BPH repellent effects of the extract fractions obtained at different growth stages of either JSB or HCB varieties did not show any correlations. The effect of ethyl ether fraction on BPH repellent was continually increased by 30 h after treatment and thereafter decreased. In addition, the first sub-fraction separated by a flash column chromatography eluted with chloroform:methanol (9:1, v/v) from the BPH effective ethyl ether faction in JSB variety might be meaningful to repel BPH from BPH susceptible target rice plants. The results indicated that the ethyl ether fraction obtained from JSB was higher in repellent activity than in insecticidal activity, and suggesting that there might be specific substance(s) in the first sub-fraction (sF1) of the ethyl ether fraction in JSB that could provide repellent activity against BPH.

A cognitive survey on the Diversification of class year from Junior Colleges by Changing Educational Environment-Focused on Health Sciences Departments (교육환경 변화에 따른 전문대학 수업 연한 다양화에 대한 인식조사 - 보건계열학과 중심으로)

  • Park, Cheolin;Park, Su-Jin;Kwon, Soon-Mu;Kim, Won-Gi;Chang, Ki-whan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.186-196
    • /
    • 2018
  • Junior colleges are higher education institutions that have played a major role in the economic development of Korea by providing the necessary human resources for its industrial development. Recently, however, they have experienced difficulties due to the reduction in the number of students. Therefore, it is time for junior colleges as a representative higher vocational education institution to change their role in this rapidly changing environment, and adopt a survival strategy through mutual cooperation and competition. The purpose of this study was to analyze the current state of the national health universities, to investigate the policy changes adopted by colleges and universities, and to utilize the results as data. This study analyzed the current status of health science colleges nationwide and investigated the policy changes as well as the directions presented to the colleges, in order to use the results as the basic data to promote the diversification of the class periods and degree programs. This study surveyed 636 professors from health sciences departments and industry workers from May 1 to May 30, 2017. 70.7% of the respondents supported the transition of the existing three-year systems of the health science departments to four-year systems. The reason for this is that it is possible to strengthen the field practice and personality education of the students by having a sufficient number of class periods, and to provide them with an equal educational background. The most anticipated effect of the transition to a four-year system is to improve the social status of medical personnel and to improve the educational environment of the colleges/universities. Moreover, the universities, associations of medical personnel and Ministry of Education are expected to play a leading role in the transition to the four-year system. Based on the results of this study, it was concluded that a more systematic and advanced vocational education system for the training of professional healthcare workers is needed in the upcoming fourth Industrial Revolution era. Also, this transition is expected to actively foster the education of advanced health care workers thanks to the diversification of the degree programs through the adjustment of the class periods which can be completed by general university (4-year) graduates.

Application Effect of Heating Energy Saving Package on Venlo Type Glasshouse of Paprika Cultivation (파프리카 재배 벤로형 유리온실에서 난방에너지 절감 패키지 기술 적용효과)

  • Kwon, Jin Kyung;Jeon, Jong Gil;Kim, Seung Hee;Kim, Hyung Gweon
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.225-231
    • /
    • 2016
  • Glasshouse heating package technologies to improve energy usage efficiency in winter were developed. Heating package was composed of the ground water source heat pump with heating capacity of 105kW, the aluminum multi-layer thermal curtain with six layers of different materials and the root zone local heater with XL pipes of ${\phi}20mm$. Venlo type glasshouse($461m^2$) with the heating package was compared with the same type and area control glasshouse with the light oil boiler, the usual non-woven fabric thermal curtain with respect to the glasshouse inside temperature, relative humidity, crop growth, and heating energy consumption. The results of test in paprika cultivation glasshouses showed that the air temperature inside glasshouse with aluminum multi-layer thermal curtain was maintained $2.2^{\circ}C$ higher than that of control glasshouse in un-heating night time and the temperature in bed with root zone local heating was $4.7^{\circ}C$ higher than that in bed without local heating. Average heating coefficient of performance(COP) of the ground water source heat pump used in paprika cultivation was 3.7 and the glasshouse inside temperature was maintained at $21^{\circ}C$ of heating set up temperature. The heating energy consumptions per 10a were measured at 14,071L of light oil and 364kWh of electric power for the control glasshouse and 35,082kWh for the glasshouse applied heating package. As results, the heating cost of the glasshouse applied heating package was 87 percent lower than that of control glasshouse. The growths of paprika in glasshouses of control and applied heating package did not show any significant difference.

Improvement of Heat Pump Heating Performance by Selective Heat Storage Using Air Heat of Inside and Outside Greenhouse (온실 내외부 공기열의 선택적 축열에 의한 히트펌프 난방성능 개선)

  • Kwon, Jin Kyung;Kim, Seung Hee;Jeon, Jong Gil;Kang, Youn Koo;Jang, Kab Yeol
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.353-360
    • /
    • 2017
  • In this study, the design and performance test of the air to water heat pump capable of producing hot water for greenhouse heating by using the surplus solar heat inside the greenhouse and the air heat outside greenhouse as the selective heat source were conducted. The heat storage operations using the surplus solar heat and the outside air heat were designed to be switched according to the setting temperature of the greenhouse in consideration of the optimum temperature range of the crop. In the developed system, it was possible to automatically control the switching of heat storage operation, heating and ventilation by setting 12 reference temperatures on the control panel. In the selective heat storage operation with the surplus solar heat and outside air heat, the temperature of thermal storage tank was controlled variably from $35^{\circ}C$ to $52^{\circ}C$ according to the heat storage rate and heating load. The heat storage operation times using the surplus solar heat and outside air heat were 23.1% and 30.7% of the experimental time respectively and the heat pump pause time was 46.2%. COP(coefficient of performance) of the heat pump of the heat storage operation using the surplus solar heat and outside air heat were 3.83 and 2.77 respectively and was 3.24 for whole selective heat storage operation. For the comparative experiment, the heat storage operation using the outside air heat only was performed under the condition that the temperature of the thermal storage tank was controlled constantly from 50 to $52^{\circ}C$, and COP was analyzed to be 2.33. As a result, it was confirmed that the COP of the heat storage operation using the surplus solar heat and outside air heat as selective heat source and the variable temperature control of the thermal storage tank was 39% higher than that of the general heat storage operation using the outside air heat only and the constant temperature control of the thermal storage tank.

Analysis of Air Temperature and Humidity Distributions and Energy Consumptions according to Use of Air Circulation Fans in a Single-span Greenhouse (단동온실 내 공기순환팬 사용에 따른 온습도 및 에너지소비량 비교 분석)

  • Lee, Tae Seok;Kang, Geum Choon;Kim, Hyung Kweon;Moon, Jong Pil;Oh, Sung Sik;Kwon, Jin Kyung
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.276-282
    • /
    • 2017
  • The aim of this study was to compare and analyze air temperature and humidity distribution and energy consumptions according to using air circulation fans in single-span greenhouses. The greenhouses located in Cheongnam-myeon, Cheongyang-gun, Chungcheongnam-do, Korea. There were cherry tomatoes in the greenhouses and the size of greenhouses was as follows;ridge height : 3.2 m, wide : 6 m, length : 95 m. The heating system was composed of a hot-water boiler and 6 FCUs(Fan Coil Unit)-4 FCUs were on bottom with duct and 2 FCUs were installed at 2.0 m. A total of 18 air circulation fans(impeller's diameter : 230 mm) were bilaterally arranged in 2 rows in the experimental greenhouse. The sensors for measuring air temperature and humidity were located at a quarter and three quarters of a length. The height of sensors were 0.8 m, 1.8 m. To calculate energy consumption in greenhouses, water temperature at inlet and outlet in a water pump, volume of water were measured. Form February 3rd to March 23th, temperature, humidity and energy consumptions were measured during heating time(6pm~7am). In a greenhouse without fans, the average differences of temperature and humidity were $0.75^{\circ}C$, 2.31%, respectively. The operation of fans showed their differences to $0.42^{\circ}C$, 1.8%. The standard deviation of temperature and humidity between measuring points in the greenhouse with fans was lower than the greenhouse without fans. Total energy consumptions in a greenhouse without fans were 4,673 kWh. In the greenhouse with fans, the total energy consumptions were 4,009 kWh. The energy consumptions in a greenhouse with fans 14.2% were less than the greenhouse without fans. Therefore, air circulation makes temperature and humidity uniform and saves energy consumptions for heating.