• Title/Summary/Keyword: 환경건축

Search Result 4,153, Processing Time 0.025 seconds

A Study on the Changes of the Apartment price in Accordance with Project process of Super high-rise mixed use buildings (초고층 주상복합 건물의 개발사업 단계에 따른 주변지역 아파트가격의 변화에 관한 연구)

  • Kim, Sang Hwan;Choy, Won Cheol;Kim, Ju Hyung;Kim, Jae Jun
    • KIEAE Journal
    • /
    • v.10 no.5
    • /
    • pp.159-164
    • /
    • 2010
  • High-rising buildings are a sort of solution to recent cities. Till now real estate development was concentrated in new development on vacant lots, and it resulted urban sprawl. Generally large cities are confronted with the exodus of industry and population from city. High-rising buildings solve many problems associated with this problem. The purpose of this research is to identify the effect of super high-rise mixed use building project process on apartment price. For this study, the hypothesis is that price of apartments is influenced by project process of super high-rise mixed use building. The study concerned 4 variations of project process that is building permits stage, sale stage, construction starting stage and stage of moving into building. The target projects of buildings are selected by number of floor(over 40 floors) and construction time. And 48 apartment complex are selected around super high-rise mixed use building. This study uses hedonic price function to analysis effect of project process of super high-rise mixed use building. A price of apartments is defined as a dependent variable. Characteristics of residence, complex, district and super high-rise building are defined as independent variables. The results are as follows; first, there is no error in price model of this study. Second, it is found that apartment price was influenced negatively by building permit stage and sale stage of super high-rise mixed use building. But that was influenced positively by construction starting stage and stage of moving into building of that. Third, as the project process of super high-rise mixed use building was proceeded, price of apartments was increased.

A Study on Finding Ways to Reduce the Emission of Target Greenhouse Gases for Various Scenarios Utilizing the Building Energy Efficiency Rating (건물에너지 효율등급 제도를 이용한 시나리오별 목표 온실가스 저감방안에 관한 연구)

  • Bang, Young-Hyun;Kang, A-Ram;Park, Hyo-Soon;Suh, Seung-Jik
    • KIEAE Journal
    • /
    • v.12 no.3
    • /
    • pp.89-94
    • /
    • 2012
  • The international community is paying close attention to the climatic changes caused by the meteorological anomalies. In response to such phenomena, after the adoption of the United Nations Framework Convention on Climate Change in 1992, efforts to actively respond to the meteorological changes are proliferating all over the world; even in the Republic of Korea, the issue to tackle the meteorological changes has emerged as a top-priority national agenda. In the year of 2008, after the declaration of the low-carbon, green-growth paradigm by the government, the UNFCCC COP15 has announced a 30% reduction target of the emission of the greenhouse gases by 2020 as compared to the "Business As Usual, BAU" and has also confirmed, as a commitment plan to achieve reduction in the emission of greenhouse gases, the reduction target of greenhouse gases for all sectors, industries and years. (26.9% for buildings) Since the construction of the new apartment houses in the year of 2001, the "Building Energy Efficiency Rating", has been applied to newly constructed building complexes, built in 2010; the accumulated emission reduction has been evaluated at around 450,000toe and the accumulated carbon dioxide emission reduction is at $826,000tCO_2$ And through the prediction of these values under various scenarios (New construction, new construction / expansion of existing uses, when transferred to 1stgrade), the effects on the degree of reduction of greenhouse gases by the increased certification of the Building Energy Efficiency Rating are an alyzed and it is our aim to express the importance of the certification system capable of carrying out a quantitative evaluation of the building energy in order to establish the strategy to reduce the emission of carbon dioxide.

Daylight Assessment of Venetian Blind by Shading Heights and Slat Angles (베네시안 블라인드의 높이와 슬랫각도 조절에 따른 계절별 실내주광분포 분석)

  • Shin, Hwa-Young;Kim, Gon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.11 no.2
    • /
    • pp.105-111
    • /
    • 2011
  • Aims of this study is to investigate the daylighting control strategy of venetian blind system was performed as a function of ratio of shading height to window and slat angles in the preliminary stage of the parametric study. Floor-to-ceiling window walls of living spaces are used widely in apartment buildings since the Korean government has legally allowed elimination of the balcony area. Enlarging living area by balcony elimination, the larger glass area of window is exposed to the direct sunlight. As a common sunlight controlling device, blind system can be used in all orientations and all latitudes and it may obstruct, absorb, reflect and transmit solar radiation to building by proper adjusting. However, blind system can produce discomfort in occupant and less energy efficiency, if it has not been controlled optimally. The simulation model was based on the unit module of typical living space with balcony elimination. The room dimension was $6.0m(w){\times}6.9m(d){\times}2.7m(h)$ with floor to ceiling height of 2.5m. The blind system was simulated at five slat angles (horizontal, $30^{\circ}$, $45^{\circ}$ upward and downward tilted) and the four ratio of shading height to window (fully closed, partly opened, no-blind) using the Desktop RADIANCE 2.0 program. The series of simulation results indicates that the advantages of available daylight and outside of view can be improved by proper adjusting blind system.

Analysis on the Time and Spacial Characteristic of Citizen Outdoor Activity (관찰기법을 이용한 도시민의 야외 운동장소 이용특성 분석 - 이용 시간과 공간을 중심으로 -)

  • Lee, Yeun-Sook;Ahn, Chang-Houn;Lee, Dong-Joo;Lee, Eu-Binne
    • KIEAE Journal
    • /
    • v.11 no.2
    • /
    • pp.83-90
    • /
    • 2011
  • This study has observed 12 parks (20 spots) in Seoul to know the number of users, gender, age groups for the units of 30 minutes from 06:00AM till 10:00PM. According to the systematic characteristic of the surveyed outdoor exercise place, the details of their users during the summer time were analyzed from the objective viewpoint. Major results of analysis are as follows: Firstly, in case of the riverside of the Han River 07:00AM marked a mini peak and 21:00PM reached the peak, and in case of sub-stream neighborhoods, 21:00PM showed only one peak. On the other hand, in case of neighborhood parks (including pocket park) no peak time was noticeable. Secondly, in case of the riverside of the Han River and the neighborhoods of sub-streams, people used the exercise equipment remarkably at night, and in case of neighborhood parks people used the exercise equipment a little bit more in the morning than in the afternoon. Thirdly, in case of nights in summer the riverside of the Han River was preferred by men, while the neighborhoods of sub-streams were preferred by women and the neighborhood parks showed no difference in the number of users among men and women. Fourthly, differently from men, women do not regard the exercise so seriously as men and their purpose of using outdoor exercise place is to use their leisure time mostly with their family members or neighbors, and women prefer light and comfortable exercises. Fifthly, in summer even those who like to exercise a lot like to exercise in the morning to avoid summer heat. Therefore, provision of shades in summer is very important.

A study on the annual energy performance of apartment building with the equivalent U-value of envelope considering the effect of thermal bridges (공동주택 외피의 열교영향을 고려한 상당열관류율 및 연간 에너지소비성능 평가 연구)

  • Kim, Dong Su;Yoon, Jong Ho;Shin, U Cheul;Kwak, Hee Yul
    • KIEAE Journal
    • /
    • v.12 no.3
    • /
    • pp.41-46
    • /
    • 2012
  • The building envelope is important specially for saving energy consumption of residential buildings. but Apartment houses in Korea commonly have inside insulation system which have constantly arisen thermal bridges, the risk of heat loss, as a necessity. This study aims to evaluate integrated insulation performance according to the different shapes of external walls, adjacent to windows. The thermal performance analysis was carried out by Equivalent U-value and using the three-dimensional heat transfer computer simulation (TRISCO-RADCON), under nine different cases of comparing among three each of different bases(current standard model, 30percent energy saving model and 60percent energy saving model). The heating and the cooling load were also compared between two cases (standard U-value and Equivalent U-value) of three each of different bases, using the Building energy simulation which is based on DOE-2.1 analysis. As results, it turns out that if the Equivalent U-value is considered on the envelope analysis, the heat flow loss will be increasing more than the standard U-value, and if heat insulation property of the residential building reinforced rather than current, the rate of influences on the thermal bridges would be extremely expanded. In addition, it is shown that annual heating loads of the apartment house with applied Equivalent U-value substantially increased by more than 15 percent compared to those with the existing U-value, but annual cooling loads were negligibly affected.

A Study on Correlations of the Gap Ratio of Apartment Houses Arrangement and the Wind Field (공동주택단지배치의 간극비와 바람장의 상관관계에 관한 연구)

  • Moon, Chul-Seong;Oh, Se-Gyu;Cho, Sung-Woo
    • KIEAE Journal
    • /
    • v.11 no.2
    • /
    • pp.75-82
    • /
    • 2011
  • In Korea, the ratio of population in urban areas used to be only 50.1% in 1970, but with the value risen to 90.8% in 2009, urbanization is going on rapidly. Urbanization, which occurs by the rampantly planted buildings, has become major source of raising building density, changing wind direction and reducing wind amount, and such reductions are affecting even inside the building. In each year, among the total energy consumption in Korea, residential portion takes up significant ratio, and specifically the ratio of apartment house is shown to be highest. In order to solve such problem, many studies are being conducted for the improvement of natural ventilation performance. The natural ventilation performance of apartment house are significantly determined by the characteristics of external and internal structure, but in macroscopic perspective, the performance is established fundamentally by the layout characteristics of the main building of the apartment house in preparation for wind conditions. So far researches on raising the thermal comfort through elevation of ventilation performance have been conducted actively, but many of them propose only theoretical concepts deduced through wind path analysis, and do not include any indicator to measure ventilation performance simply only with area data from layout planning stage. Therefore, in this study, gap ratio a wind field measuring indicator was developed, and after the ventilation characteristics by layout types and main building uniformity were identified, the scope of gap ratio efficient for ventilation and that of uniformity were clarified, followed by verification through simulation.

Application of the Flowerbed Type Infiltration System for Low Impact Development - Focus on the Application to Eco-Village - (저부하형 개발을 위한 화단형 빗물침투시설 적용방안 - 생태전원마을에서의 적용을 중심으로 -)

  • Han, Young-Hae;Lee, Tae-Goo;Schuetze, T.
    • KIEAE Journal
    • /
    • v.12 no.3
    • /
    • pp.33-40
    • /
    • 2012
  • Since 2000 country region developmental policy has been to integrate not only the improvement of physical living environment but also various subjects on ecology, environment, scenery, local culture, and green tourism. This study has recently established a decentralized Rainwater Management plan in order to provide an hydrology cycle system to the eco-village being planned by Seocheon-gun as a part of the garden village development business promoted by the ministry of agriculture and forestry. Hydraulic conductivity of the subject area is measured at $10^{-7}{\sim}10^{-10}m/sec$, and a flowerbed-type rainwater Infiltration system capable of controlling a non-point pollution source that stems from the development-caused impermeable surface has been applied. In the case of rainwater flowing out from the main entrance way and parking lot within the complex being treated in the flowerbed-type rainwater infiltration system, natural purification effects via soil and plants as well as natural water cycling effects through evaportranspiration and infiltration are expected. The significance of this study, compared to conventional decentralized rainwater management being applied limited to the urban areas, is that it offers appropriate rainwater management planning based on the analysis of the current situation of the subject area. Decentralized Rainwater Management is a valuable measure both economically and ecologically that reduces the burdens on local underground water cultivation as well as rain water pipe lines or purification systems, and sewage pipes.

Potential of Children's Museum as a Base for Donation Network - Focused on Chicago Children's Museum - (기부네트워크 구축 거점으로서 어린이박물관의 잠재성 분석 연구 - 시카고 어린이박물관 사례를 중심으로 -)

  • Lee, Yeunsook;Lim, Yeaji;Kim, Kwangmi
    • KIEAE Journal
    • /
    • v.12 no.3
    • /
    • pp.3-10
    • /
    • 2012
  • The purpose of this study is to seek a planning approach for children's museum within Korean context that promotes community participation. A literature review method and a field survey method were used. Literature reviews on community participation paradigm, residents' participation and donation networks in community regeneration processes, and finally on case studies on children's museum in Korea were carried out. Through the field survey on Chicago Children's Museum(CCM) located in downtown Chicago, its role was identified as networking systems of community participation and donation and was verified as a socio-physical base for vitalizing donation culture that is an active and a leading community participation method. As a result, CCM has engaged many partnerships with city organizations and local schools to provide diverse and unique programs that are not only targeted to children but also parents, teachers and visitors. Also, an evolution of CCM through various types of donations and community participation was delineated. CCM was found successfully in restoring community spirit and vitalizing economical growth where it once was a decayed city area. Rather than focusing on descriptive technique of typical children's museum, this study explored how community fabric is made and acted out, through rethinking community participation's value, and how it can influence a physical space. CCM, as a good example of community participatory museum, the results can be used as a reference in planning and directing community participation based children's museums in Korea. It is significant to shed light on children's museum as an opportunity of social space which can empower community.

A study on Hue and Surface Texture with the addition ratio of Pigment and Straw in Clay Plaster (안료와 볏짚의 첨가량에 따른 흙미장의 색상과 표면질감에 관한 연구)

  • Hwang, Hey Zoo;Kim, Tae Hun;Yang, Jun Hyuk
    • KIEAE Journal
    • /
    • v.9 no.1
    • /
    • pp.77-83
    • /
    • 2009
  • In this experiment, we used different addition ratio of the pigment and straw, to improve the decorative effect of the finishing touch while finding the kinds of clay colors taking on many sophisticated images, through the comparison between the various colors and textures of the surface. (1) To test the plaster material, added were the pigment of Red, Yellow, Black, and Green by the percentages of 0.5, 1, 1.5, 2, and 2.5, respectively, followed by the analysis of the color changes of the plaster material using the Photoshop (RGB). The results showed the bigger the addition ratio of the red color is, the higher the numeral values of RGB after it dried. However the brightness after drying didn't showed a big difference depending on the addition ratio. With the addition of the yellow pigment, the color difference between after and before drying was bigger in the order of Blue, Green and Red; the brightness increasingly rose while the saturation changed little. (2) When we scratched the plaster surface with U and V shape carving knives, the U knife didn't make a clean shape digging around the clay plaster material but with smooth textures, while the V knife made a clean cut, which represents its readily use in terms of the decorative function of the clay plaster. (3) In an experiment the surface texture was tested with different lengths and additions ratio of the straw, addition of 2cm straw by 1, 2, and 3% presented the most appropriate surface of the plaster.

A Study on Analysis for Energy Demand of the Heating, Cooling and Lighting in Office Building with Transparent Thin-film a-Si BIPV Window (투광형 박막 BIPV 창호 적용에 따른 냉난방 및 조명 부하 저감에 관한 연구)

  • Yoon, Jong-Ho;An, Young-Sub;Park, Jang-Woo;Kim, Bit-Na
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.91-96
    • /
    • 2013
  • The purpose of this study was to analyze the annual energy demand including heating, cooling and lighting according to kind of windows with transparent thin-film a-Si Building Integrated Photovoltaic(a-Si BIPV) for office building. The analysis results of the annual energy demand indicated that the a-si BIPV window was reduced by 8.4% than the clear gazing window. The base model A was combinate with a-Si BIPV window area of 67% and clear window area of 33% among the total exterior area. The model B is to be applied with low-e clear glass instead of clear glass of the base model A. The model B was reduced to annual energy demand of 1% more than the model A. Therefore, By using a-si BIPV solar module, the cooling energy demand can be reduced by 53%(3.4MWh) and the heating energy demand can be increase by 58%(2.4MWh) than clear glazing window in office building. Also, Model C applied to the high efficient lighting device to the model B was reduced to annual energy demand of 14.4% more than the Model D applied to the high efficient lighting device to the model A. The Model E applied with daylight dimming control system to the Model C was reduced to annual energy demand of 5.9% more than Model C.