• 제목/요약/키워드: 환경건축

검색결과 4,162건 처리시간 0.029초

대학교 기숙사의 전력소비량과 BIPV시스템의 발전효율·부하부담율에 관한 연구 (A Study on the Power Consumption and the Generation Efficiency and Load Rate of the Building Integrated Photovoltaic System in University Dormitories)

  • 서원덕;이강국;홍원화
    • KIEAE Journal
    • /
    • 제11권6호
    • /
    • pp.87-93
    • /
    • 2011
  • This study examines building's power consumption unit cost and Building Integrated Photovoltaic (BIPV)'s generation efficiency and load rate with the subjects of university dormitory buildings in order to suggest foundational data for new and recycled energy use and management to plan and operate university dormitories afterwards. Thereby, this research gained the following findings. 1. The quantity of solar radiation and efficiency change in the BIPV system applied to the research subject buildings after the lapse of time was averagely 8.7%, and it is thought that temperature increase determines conversion efficiency with the influence of surrounding outside temperature and the module's temperature. 2. The generation efficiency of the BIPV system in the research subject buildings was averagely 10.9%. In May, it was 13.9%, and in January, it was the lowest as 10.25%. Considering the fact that power consumption reduces during an intermediate period, it will be necessary to establish measures for equipment and power consumption load balancing. 3. The monthly load rate of the BIPV system was averagely 4.09%. In May, it was the highest as 4.94%, and in July, it was the lowest as 3.24%. 4. It is intended to conduct constant follow-up research on estimating university dormitory building's power consumption unit cost and examining the generation efficiency and load rate of the BIPV system.

학습공간으로 이용되는 대학주변 커피전문점의 조명 실태 및 평가 (The Actual State and Evaluation of Artificial Lighting on Coffee Houses Using Study Place around University)

  • 최솔지;최윤정
    • KIEAE Journal
    • /
    • 제11권6호
    • /
    • pp.53-62
    • /
    • 2011
  • This study aimed at suggesting improvement of lighting environment of the coffee house using study place. To this end, a series of field investigation was conducted in four possible target coffee houses around university. The field measurement included measurement of general illuminance and tabletop illuminance, observing illumination condition, and status of artificial lighting. Also, on-site questionnaire survey was administrated to 80 users of field measurement targets about using characteristics of coffee house and user's subjective response on light environment. The results are summarized as follows: (1) According to questionnaire survey, most of users checked 'learning (study and reading)' in 'purpose of coffee house using', and 'slightly dark' was checked most in each subjective response (brightness on general space and on tabletop at daytime/night); (2) as results of measurements on general illuminance and on tabletop illuminance during daytime, only one coffee house was suitable for standard; (3) as results of measurements on illuminance during night, all target coffee houses were not met the standard; (4) as results of uniformity ratios, almost uniformities of general illuminance were not met the standard except one case. The common problems of lighting environment of coffee house were analyzed as lack of daylight illumination e.g. having low amount of sunshine from skylight, un-uniformity of insolation by floor plan and absence of window blind, and un-uniformity of artificial luminous intensity e.g. lack of the number or brightness of artificial lighting, using the indirect lighting, using only local lighting, and non-uniform arrangement of artificial lighting.

GIS를 이용한 도시민의 야외 운동장소 접근 특성 분석 - 서울시 공원의 운동기구 사용자를 중심으로 - (Characteristics of Citizens' Access to Outdoor Exercise Places by Using the GIS - Focused on the Users of the Outdoor Exercise Equipment Installed in Parks, Seoul -)

  • 이연숙;구나은;이동주
    • KIEAE Journal
    • /
    • 제13권2호
    • /
    • pp.67-76
    • /
    • 2013
  • The purpose of this study is to analyze the accessibility to the place for outdoor exercise. For that, the departure (resident) location of the users of outdoor exercise equipment within 12 parks in Seoul have been investigated. A total of 1,733 people have been surveyed during the two-week period between Aug.2 and Aug. 15 and 815 cases were analyzed. We also investigated demographic characteristics, access method and related factors such as location, climate and visiting time. The results were coded through ArcGis program and the accessibility to each exercise location, difference in regional accessibility and accessibility characteristics in terms of climate and time have been analyzed. The results are as follows: First, visitors to the Han River start from the places further than the visitors to the streamlines. Second, the average moving distance is longer for the users aged under-60 than for the users aged 60 and over to reach the exercise place. And the average moving distance for visitors to the Han River destination is the longest with 748 meters, followed by 203 meters for general parks and 92 meters for streamline parks, respectively. Third, in each non-waterfront parks, the moving distance by users under-60 was longer by about 230 meters than that by users 60 and over. Fourth, exercisers in the weekend travel more by 244 meters than those during the midweek users to reach the exercise place. Fifth, the number of visitors to the Han River increased in the weekend while visitors to the streamlines decreased in the same period. Sixth, the traveling length for bicycle users is three times as much as that for pedestrian visitors. And the departure locations of bicycle users were more widely distributed.

브랜드 아파트에 나타난 자연친화적 외부공간의 디자인 특성에 관한 연구 (Nature-Friendly Design Characteristics of Outdoor Spaces in Brand Apartments)

  • 황연숙;이송현
    • KIEAE Journal
    • /
    • 제13권1호
    • /
    • pp.93-100
    • /
    • 2013
  • A outdoor space of the brand apartment can improve the quality of the whole environment in apartment and has differentiated identity in apartment housing through various versions of the green space and water space plan. The purpose of this study is to evaluate nature-friendly design characteristics in brand apartments and to offer a basic information for planning of brand apartment. In concrete, nature-friendly design did by green space and water space that can analyze by visual, and investigation contents divided to position, form, user behavior, link space from user viewpoint by case study. This study examined a case of eight brand apartments located in Gangnamgu, Seoul. We has divided the characteristics of a green space into horizontal type, vertical type, multi-dimensional type and has divided the water space into stagnant water type, flowing stream type, waterfall type and fountain type. The findings are summarized as follows: First, in case of the space of brand apartment, the application of horizontal and vertical greenery was lower compare with multi-dimensional green space. The most of items for multi-dimensional greenery have been planned to the open space and promenade. Second, a stagnant water type of water space features well used in most of the cases but a water space of signs of activity like a flowing stream, waterfall, fountain types were underused because of problem of administrative and maintenance expenses. Thirdly, Water space of brand apartments was planned with specialization item by apartment housing but green space does not have differentiated item and was planned by most similar form.

일본 주택의 유니버설디자인 특성에 관한 연구 (Universal Design characteristics shown in the Japanese model houses)

  • 이연숙;이소영;여욱현;장미선;이선민;이유진
    • KIEAE Journal
    • /
    • 제7권1호
    • /
    • pp.5-13
    • /
    • 2007
  • Since aging has become one of most hot and serious issues in the whole global world, universal design as a strategic concept to enable the elderly age in place has received much attention and its importance is getting recognized. Japan has undergone the Aging phenomenon much earlier than Korea and other countries. During that time, through much trials and errors, it accumulated the wisdoms and techniques to precede aging friendly environment and products. Therefore current Japan house is a comprehensive setting which embraces lots of universal design features that has a valuable implication for Korean development that faces fast aging future. The purpose of this study was to delineate characteristics of universal design features appeared in Japanese Model houses. One site of housing park in the city where various model houses of representative housing construction companies was selected as a cluster area for data collecting. Data were collected mainly through field survey at the housing park of Tokyo during November, 2006, and additional data were collected through website and company information of relevant company. Universal design features were extracted for 17 houses of the housing park and sorted and analyzed according to the analysis frame. The frame were made using 2 major clusters; space area, and 8 universal design principle. Results showed a range of universal design feature and its detail universal design principle satisfied. The 8 principle currently developed became to house realistic practical examples and theory became proved its impractical power. The academic, educational and industrial implication were documented.

혼합형 채광조절장치가 실내공간의 휘도분포에 미치는 영향에 관한 Mockup 실험평가 (Luminance Performance of a Room with Light Guide and Blind Systems by Mockup Experiments)

  • 신화영;안현태;김정태
    • KIEAE Journal
    • /
    • 제7권1호
    • /
    • pp.65-72
    • /
    • 2007
  • As ecological design elements, daylighting can be applied to provide adequate illumination on visual tasks to create an attractive visual environment and to save electrical energy. Daylighting control systems reject direct sunlight and penetrate it onto the ceiling or to deep into the room. This study aims to evaluate the luminance environment of sloped light guide with automated venetian blind systems according to sun angle changes. For evaluation, a mock-up model was used and the south facing side-window mounted between the clerestory window and the view window. To assess luminance performance, 3 view points of luminance were monitored. As results, the conventional and lightshelves show ideal luminance ratio between workplane and surroundings(3:1) and workplane and darkness area(2:1) due to total ratio of surroundings and darkness area has lower ratio than workplane. Compared to the lightshelves window, conventional window shows unrelieved effect in between the workplane and brightness area(1:5). It means that there has low deviation according to the required standards. Also, compared to the ratio between the brightness area and darkness area(2~6:1) conventional window with high deviation(10~20:1) provide discomfort glare due to the excessively strong contrast, while lightshelves window shows a required luminance ratio that provide a three-dimensional effect to occupants. Therefore, luminance distribution indicate that application of a lightshelves and blinds not only has a significantly positive effect but also offers higher luminance quality in a daylit room

온실의 열을 이용한 저에너지하우스의 패시브 난방 효과 분석 (An Analysis on Effects of Passive Heating of Low Energy House Using Heat in Greenhouse)

  • 유동완;이태구
    • KIEAE Journal
    • /
    • 제16권5호
    • /
    • pp.103-109
    • /
    • 2016
  • Purpose: In Korea, to reduce greenhouse gas emissions, energy performance standard of buildings is being reinforced with goals of Passive House until 2017 and Zero Energy House until 2025 in order to reduce emissions from buildings which constitute a quarter of greenhouse gas emissions. In order to achieve the target of Zero Energy House, it is certainly necessary to develop renewable energy that can replace cooling and heating energy occupying a significant amount of building energy consumption after increasing the energy performance firstly. Method: In this study, effects of heat in greenhouse heated by solar heating on indoor heating were analyzed by constructing a greenhouse in front of the Low Energy Building. Result: As a result, indoor temperature was increased by peak average $27.8^{\circ}C$, peak average $6.8^{\circ}C$ was increased from when heat in greenhouse has not been used for heating and indoor surface temperature was increased by average $5.1^{\circ}C$. It shows it can be possible to use heat in greenhouse for heating, if the heating effects can be same as this experimental result because Energy Saving-Type buildings such as Low Energy House or Passive House keep from 18 to $20^{\circ}C$ in winter. Therefore, even if energy supply is cut off by disasters and other reasons, cooling and heating can be possible for some time.

Indoor Neutral Temperature Range using Temperature and Humidity Perception Assessment

  • Yang, Wonyoung
    • KIEAE Journal
    • /
    • 제16권5호
    • /
    • pp.29-37
    • /
    • 2016
  • Purpose: Indoor thermal comfort can be identified by combination of temperature, humidity, and air flow, etc. However, most thermal indexes in regard to thermal comfort are temperature dominant since it has been considered as a significant factor affecting to indoor thermal comfort The purposes of this study are to investigate indoor neutral temperature range of young Koreans with humidity perception, and to introduce a neutral temperature for temperature preference as well as temperature sensation in order to define the neutral temperature range chosen by occupants. It could be used as basic data for heating and cooling. Method: 26 research participants volunteered in 7 thermal conditions ($18^{\circ}C$ RH 30%, $18^{\circ}C$ RH 60%, $24^{\circ}C$ RH 30%, $24^{\circ}C$ RH 40%, $24^{\circ}C$ RH 60%, $30^{\circ}C$ RH 30%, $30^{\circ}C$ RH 60%) and completed subjective assessment in regard to temperature/humidity sensation and preference twice per condition in an indoor environmental chamber. Result: In RH 30%, sensation neutral temperature was $25.1^{\circ}C$ for men and $27.0^{\circ}C$ for women, and preference neutral temperature was $25.5^{\circ}C$ for men and $27.8^{\circ}C$ for women. In RH 60%, sensation neutral temperature was $23.6^{\circ}C$ for men and $25.9^{\circ}C$ for women, and preference neutral temperature was $23.4^{\circ}C$ for men and $26.3^{\circ}C$ for women. Neutral temperature increased with increasing relative humidity. Women were sensitive to humidity changes. Men expressed humidity changes as temperature variations. In most conditions, preference neutral temperatures were higher than sensation neutral temperatures, however, the preference neutral temperature for men in humid condition was lower than the sensation neutral temperature.

저소득층 에너지효율개선사업에 따른 난방에너지 절감 효과 및 경제성 분석 - 저소득층 단독주택 단열개선을 중심으로 - (Heating Energy Saving and Cost Benefit Analysis According to Low-Income Energy Efficiency Treatment Program - Case Study for Low-Income Detached Houses Energy Efficiency Treatment Program)

  • 김정국;이정훈;장철용;송두삼;류승환;김종훈
    • KIEAE Journal
    • /
    • 제16권5호
    • /
    • pp.39-45
    • /
    • 2016
  • Purpose: The purpose of this study is to analyze the energy saving and cost benefit analysis of the Low-income Energy Efficiency Treatment Program supported by KOREF(Korea Energy Foundation). This program was launched in 2007 and performs building energy retrofit for the low-income and energy poverty houses. Method: Energy simulation and cost benefit analysis were accomplished for the low-income detached houses. The structure of detached house was a lot og block structure, wood frame (single glass) and concrete roof. Baseline model of the low-income detached houses was proposed. Result: Annual heating energy consumptions were decreased by about 3.2% with the window system replacement(Case 1), 9.3% with reinforcement of insulation(Case2), and 12.5% with both(Case 3) compared to those of baseline model. The construction cost will be recouped within 5 years for the Case 1, 3 years for the Case 2, and 3 years for the Case 3. Case 3 was the most cost beneficient construction method in the analyzed cases in this study.

외부 차양장치의 적용실태에 관한 통계적 분석 (Statistical Analysis on Application of External Solar Shading Devices)

  • 김효중;이철성;윤종호
    • KIEAE Journal
    • /
    • 제16권5호
    • /
    • pp.65-71
    • /
    • 2016
  • Purpose : The solar shading device carries out roles in a reduction of the cooling load and an improvement of the thermal comfort of occupants by adjusting incident solar radiation. In addition, The shading device enhances the visual sensation comfort by controlling the optical properties. In order to improve building performance and comfort of occupancy, interests in application of the shading devices are getting increasing. This study investigated the application and effectiveness of the external shading device design using statistical analysis. The outcome of this paper could be utilized for the realization of status quo and for an estimation of effectiveness of the shading device Method : The period of data gathering was between 2003 and 2014 and total 459 cases of practical building project were investigated. Firstly, this study defined qualification of the shading devices; the shading device should have minimum protruding lengths of 150mm to outside and have the function of shading control. This paper investigated application rate of the shading device in real project, regional rate of application, annual change of application, materials and types. Result : The statistical analysis showed that the application rate of shading devices was 25.7% in total 459 building design projects. The application rate in central and southern region was 25.3% and 27.0% respectively. Meanwhile, Jeju region showed 22.2%, which was the lowest rate although this area needs more shading devices. The application number of the shading device was the smallest in 2007, but the rate gradually increased after that. The applications was the largest in 2014 due to growing interest of the shading devices in the building.