• Title/Summary/Keyword: 확산실험

Search Result 2,441, Processing Time 0.037 seconds

A Study on Corrosion Properties of Reinforced Concrete Structures in Subsurface Environment (지중 환경하에서의 철근콘크리트 구조물의 부식 특성 연구)

  • Kwon, Ki-jung;Jung, Haeryong;Park, Joo-Wan
    • The Journal of Engineering Geology
    • /
    • v.26 no.1
    • /
    • pp.79-85
    • /
    • 2016
  • A concrete silo plays an important role in subsurface low- and intermediate-level waste facilities (LILW) by limiting the release of radionuclides from the silo geosphere. However, due to several physical and chemical processes the performance of the concrete structure decreases over time and consequently the concrete loses its effectiveness as a barrier against groundwater inflow and the release of radionuclides. Although a number of processes are responsible for degradation of the silo concrete, it is determined that the main cause is corrosion of the reinforcing steel. Therefore, the time it takes for the silo concrete to fail is calculated based on two factors: the initiation time of corrosion, defined as the time it takes for chloride ions to penetrate through the concrete cover, and the propagation time of corrosion. This paper aims to estimate the time taken for concrete to fail in a LILW disposal facility. Based on the United States Department of Energy (DOE) approach, which indicates that concrete fails completely once 50% of the volume of the reinforcing steel corrodes, the corrosion propagation time is calculated to be 640 years, which is the time it takes for corrosion to penetrate 0.640 cm into the reinforcing steel. In addition to the corrosion propagation time, a diffusion equation is used to calculate the initiation time of corrosion, yielding a time of 1284 years, which post-dates the closure time of the LILW disposal facility if we also consider the 640 years of corrosion propagation. The electrochemical conditions of the passive rebar surface were modified using an acceleration method. This is a useful approach because it can reduce the test time significantly by accelerating the transport of chlorides. Using instrumental analysis, the physicochemical properties of corrosion products were determined, thereby confirming that corrosion occurred, although we did not observe significant cracks in, or expansion of, the concrete. These results are consistent with those of Smartet al., 2006 who reported that corrosion products are easily compressed, meaning that cracks cannot be discerned by eye. Therefore, it is worth noting that rebar corrosion does not strongly influence the hydraulic conductivity of the concrete.

A Chemical Study of the Periodic Precipitation Reaction in Natural Rocks (자연 암석에서 나타나는 주기적침전반응의 화학적 연구)

  • Jun, Sang-Ho;Han, Mi-Ae
    • Economic and Environmental Geology
    • /
    • v.40 no.4
    • /
    • pp.491-496
    • /
    • 2007
  • This study conducted a chemical experiment on the Leisegang phenomenon, which is known to be the principle of rhyolite formation, and analyzed the results. Even if the same chemical elements precipitated, the shape of Leisegang rings was different according to the condition of medium and depending on inner electrolyte and outer electrolyte. The experiment used agar, gelatin and mung-bean jelly as media. We prepared 0.01M inner electrolyte containing agar 1%, gelatin 2% and mung-bean jelly 5% and curdled the solution at room temperature for 12 hours and, as a result, we obtained viscosity optimal for experimenting on the diffusion of outer electrolyte, and Leisegang rings appeared clearly according to the characteristic of each chemical element. In $PbI_2$ with solubility product($K_{sp}$) of $7.9{\times}10^{-9}$ the intervals of Leisegang rings caused by the reaction of inner electrolyte 0.01M KI and outer electrolyte 25% $Pb(NO_3){_2}$ were narrow between 0.01cm and 0.12cmm but increased gradually, but in with of $8.3{\times}10^{-17}$ the intervals of Leisegang rings caused by the reaction of inner electrolyte 0.01M KI and outer electrolyte 25% $AgNO_3$ were between 0.7cm and 0.45cm and decreased gradually. This suggests that, in the chemical formation of Leisegang rings, the interval and size of the rings are correlated with the solubility product of the precipitates.

Air-sparging Technology for Remediation of Specific Aquifer Layer Using Surfactant (계면활성제를 이용한 오염대수층의 선택적 폭기기술)

  • Kim, Heon-Ki;Song, Young-Su;Kwon, Han-Joon
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.6
    • /
    • pp.23-30
    • /
    • 2008
  • Air sparging technique has been used for remediation of VOC(volatile organic compound)-contaminated aquifer. The aim of this study was to develop an innovative air sparging technique that enhances the efficiency of air intrusion into a specific horizontal layer of aquifer where the contaminants exist with the help of water-soluble surfactant. A twodimensional physical box model, packed with homogeneous sand, was used for simulating the aquifer in this study. Aqueous solution of anionic surfactant (100 mg/L, sodium dodecylbenzene sulfonate) was used to suppress the surface tension of groundwater. Three sets of experiments were conducted: air sparging experiment without surfactant application, air sparging experiments for box model where the surfactant solution was applied right above the air injection point, and air sparging experiments with surfactant solution layer formed in the middle of the box. It was found that the sparging influence zone was expanded up to five times of that formed by sparging without surfactant application. The size of sparging influence zone was more sensitive to the air flow (injection) rate with surfactant application than that without surfactant. More importantly, injection of air into the target aquifer layer was successful with surfactant application. Findings in this study are expected to provide more options for designing remediation processes using air sparging.

Development of Turbidity Management System for Nakdong River using Water Quality Model (수질모형을 이용한 낙동강 탁도관리시스템 구축)

  • Kim Young Do;Noh Joonwoo;Ko Ick Hwan;Kim Woo Gu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1378-1382
    • /
    • 2005
  • 여름철 집중강우시 유입되는 고탁수층은 저수지의 밀도성층으로 인하여 표수층 하부에 위치하며, 이를 적기에 배제하지 않을 경우에는 수평방향의 확산현상과 연직방향의 전도현상으로 인해 저수지 전역에 분포하게 되어, 탁수현상의 장기화를 유발한다. 이와 같은 탁수장기화에 대한 저수지내 대책의 하나로서 홍수유입후 탁도가 높은 물을 단기간동안 방류하고, 갈수기에는 탁도가 낮은 물을 방류하는 선택취수 기법을 적용할 수 있다. 임하댐의 경우, 2004년 태풍 '디앤무'와 태풍 '메기'로 인해 발생한 탁수를 선택취수를 통하여 조기에 배제함으로써 호내탁도를 저감시킨 바 있다. 그러나 이와 같은 고탁수 우선배제 기법은 반드시 하류하천의 영향범위를 사전에 분석검토하고, 하류하천의 수질현황을 고려한 합리적인 운영방안이 제시되어야 한다. 2004년 태풍 '디앤무' 발생직후의 댐방수로에서 170 NTU의 고탁수를 방류한 경우, 유하거리 250 km인 지점까지 30 NTU이상 유지된 바 있으며, 태풍 '메기'에 의한 고탁수 유입시, 임하댐 방류수 157 NTU, 안동댐 방류수 37 NTU인 경우에 임하댐 하류 113 km인 구미 선산 취수장까지 63 NTU의 탁도가 유지된 바 있다. 현재 임하댐의 경우, 하류하천으로의 방류수 수질을 모니터링할 수 있는 자동수질측정시스템이 발전취수탑 전면 1개소, 조정지댐 1개소에 설치되어 있다. 본 연구에서는 자동수질측정시스템과 연계하여 수질모형을 통하여 임하댐 하류하천인 낙동강 본류의 탁도관리시스템을 구축하고자 하였다. 환경부의 수질측정망 자료를 통하여 최근 3년간의 부유사농도의 변화양상을 분석하였으며, 태풍 직후의 낙동강 주요지점별 탁도측정자료를 이용하여 임하댐 고탁도방류에 의한 영향범위를 분석하였다. 또한 하천수질모형을 이용하여 탁수예측방법에 대하여 검토하였고, 이를 이용한 탁도관리시스템 구축을 위한 기본 방향을 제시하고자 한다.함께, 2단계에 (주)웹솔루스에서 자체적으로 설치 운영하고 있는 2개소의 하수관거 모니터링 관측시설, 그리고 안양시에서 운영하고 있는 5개소의 강우관측소와 7개소의 수위관측소를 모두 통합하여 실시간 자료를 제공하고 있다. 수위자료는 10분단위의 텍스트정보와 그래프형태로 지원되며, 검색기간 설정을 통해 원하는 기간내의 자료를 선별, 검색할 수 있다.. 또한 이와 같은 기초적인 정보를 바탕으로 하류하천의 탁수 피해를 최소화할 수 있는 선택취수탑의 운영방안을 수립할 수 있다 본 연구에서는 이를 위해 선택취수탑 주위의 성층흐름을 기존의 실험자료와 수치해석을 통하여 분석하였고, 온도성층구조나 취수구의 위치변화에 따른 방류수 수질특성을 조사하였다.쇄파대(artifical reef)와 같은 완충지대를 갖는 호안을 축조함으로써 월파량을 감소시키는 대안으로 제시하고자 한다. 본 연구 수행을 통해 태풍 내습시 발생 가능한 자연재해에 대한 사전 방지를 목적으로 태풍피해의 원인을 제시하고 이를 해결하여 현재의 방재대책이 항구적인 방재대책으로 전환될 수 있는 방안 마련의 기초 자료로 활용되기를 기대한다., L-arabinose, 및 D-galactose; 제3차(第三次) 가수분해물(加水分解物)(C)에서 L-rhamnose, D-xylose, L-arabinose 및 D-galactose, 비가수분해물(非加水分解物)(C')에서 D-xylose와 D-galactose를 검출(檢出)하였다. (4) 구성당(構成糖)의 형태(形態)와 구조(構造)를 밝히기 위(爲)해 polysaccharide C에 대한 periodate산화(酸化) 실험(實驗)을 하여 $C_5H_8O_4$당(當) periodate의 소비(消費)와 formic acid의 생성량(生成量)을 측정(測定)하였는데 periodate의 소비량(消費量)은 1.23 mole, formic acid의 생성량(生成量)

  • PDF

Extraction of Valuable Metals from Spent Desulfurizing Catalyst (탈황(脫黃) 폐촉매(廢觸媒)로부터 유가금속(有價金屬) 추출(抽出))

  • Pradhan, Debabrata;Kim, Dong-Jin;Baik, Seung-Bai;Lee, Seoung-Won
    • Resources Recycling
    • /
    • v.20 no.3
    • /
    • pp.48-54
    • /
    • 2011
  • Sulphuric acid leaching was conducted to extract the metal values from spent refinery catalyst. More than 95% of Ni and V and 30% of Mo could be leached out in 1 M sulphuric acid and 1 hr of leaching time. The decrease in Mo leaching was due to typical characteristic of Mo matrix. The activation energies of the leaching reactions showed the dissolution process follows a diffusion control mechanism. In order to leach out all Mo, further the leaching experiments were conducted with sulfur free spent refinery catalyst. For sulfur free spent refinery catalyst, a two step process of leaching with 1 M sulphuric acid followed by sodium carbonate washing showed better leaching than a two step leaching process with sodium carbonate followed by sulphuric acid washing, with almost 99% leaching of Ni, Mo and V. Solvent extraction using LIX 841 were conducted for a leach liquor containing Ni, 2 g/L; V, 9 g/L, Mo, 0.6 g/L. More than 98% of Mo was extracted from the leach liquor at A:O ratio of 5:2 in a 2 stage process. Similarly V was extracted at A:O ratio of 5:3 in a 2 stage process with 82% of total V extraction.

Sensorless Speed Control of PMSM for Driving Air Compressor with Position Error Compensator (센서리스 위치오차보상기능을 가지고 있는 공기압축기 구동용 영구자석 동기모터의 센서리스 속도제어)

  • Kim, Youn-Hyun;Kim, Sol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.104-111
    • /
    • 2018
  • The sensorless control of high efficiency air compressors using a permanent magnet type synchronous motor as an oil-free air compressor is quite common. However, due to the nature of the air compressor, it is difficult to install a position sensor. In order to control the permanent magnet type synchronous motor at variable speed, the inclusion of a position sensor to grasp the position of the rotor is essential. Therefore, in order to achieve sensorless control, it is essential to use a permanent magnet type synchronous motor in the compressor. The position estimation method based on the back electromotive force, which is widely used as the sensorless control method, has a limitation in that position errors occur due either to the phase delay caused by the use of a stationary coordinate system or to the estimated back electromotive force in the transient state caused by the use of a synchronous coordinate system. Therefore, in this paper, we propose a method of estimating the position and velocity using a rotation angle tracking observer and reducing the speed ripple through a disturbance observer. An experimental apparatus was constructed using Freescale's MPU and the feasibility of the proposed algorithm was examined. It was confirmed that even if a position error occurs at a certain point in time, the position correction value converges to the actual vector position when the position error value is found.

Validation of Surface Reflectance Product of KOMPSAT-3A Image Data Using RadCalNet Data (RadCalNet 자료를 이용한 다목적실용위성 3A 영상 자료의 지표 반사도 성과 검증)

  • Lee, Kiwon;Kim, Kwangseob
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.2_1
    • /
    • pp.167-178
    • /
    • 2020
  • KOMPSAT-3A images have been used in various kinds of applications, since its launch in 2015. However, there were limits to scientific analysis and application extensions of these data, such as vegetation index estimation, because no tool was developed to obtain the surface reflectance required for analysis of the actual land environment. The surface reflectance is a product of performing an absolute atmospheric correction or calibration. The objective of this study is to quantitatively verify the accuracy of top-of-atmosphere reflectance and surface reflectance of KOMPSAT-3A images produced from the OTB open-source extension program, performing the cross-validation with those provided by a site measurement data of RadCalNet, an international Calibration/Validation (Cal/Val) portal. Besides, surface reflectance was obtained from Landsat-8 OLI images in the same site and applied together to the cross-validation process. According to the experiment, it is proven that the top-of-atmosphere reflectance of KOMPSAT-3A images differs by up to ± 0.02 in the range of 0.00 to 1.00 compared to the mean value of the RadCalNet data corresponding to the same spectral band. Surface reflectance in KOMPSAT-3A images also showed a high degree of consistency with RadCalNet data representing the difference of 0.02 to 0.04. These results are expected to be applicable to generate the value-added products of KOMPSAT-3A images as analysisready data (ARD). The tools applied in thisstudy and the research scheme can be extended as the new implementation of each sensor model to new types of multispectral images of compact advanced satellites (CAS) for land, agriculture, and forestry and the verification method, respectively.

Adhesion Layer 사용으로 인한 Si Thin Film Anode 전극의 신뢰성 향상

  • O, Min-Seop;Song, Yeong-Hak;U, Chang-Su;Jeong, Jun-Ho;Hyeon, Seung-Min;Lee, Hu-Jeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.681-682
    • /
    • 2013
  • 전기는 우리 주변의 에너지 형태 중에서 가장 편리하고 광범위하게 사용되고 있다. 이러한 전기는 전자제품, 전기자동차, 에너지 저장 플랜트 등 매우 많은 분야에서 저장되고 사용되고 있다. 특히 에너지 저장 용량의 확대는 휴대폰, 노트북 PC 등 휴대용 IT 기기의 성장에 결정적인 역할을 하였다. 가볍고 작으면서도 고용량의 전기 에너지 저장 장치가 없었다면, 통신이나 인터넷 그리고 오락 등 다양한 기능을 작은 휴대용 기기에 구현할 수 없었을 것이다. 그러나 시간이 흐를수록 기기의 요구 성능이 높아지고 소비자의 니즈가 더욱더 다양해지고 고도화될수록 단일 부품으로 가장 큰 부피를 차지하는 에너지 저장 장치의 용량과 디자인은 점점 중요해지고 있다. 이러한 에너지 저장 장치에서 가장 친숙한 형태는 2차 전지 계열이다. 납 축전지를 비롯하여, 니켈수소, 니켈카드뮴, electrochemical capacitor와 Li ion 계열 등이 대표적이다. 특히 Li ion 배터리는 모바일, 자동차 및 에너지 저장 그리드 등과 같은 다양한 분야에 가장 많이 적용되고있다. Li ion 배터리에 대하여 현재의 핵심적인 연구분야는 전극 재료(cathode, anode)와 electrolyte에 대한 것이다. Anode 전극 재료 중에서 가장 많이 사용되는 재료는 카본을 기반으로 하는 재료로 안정성에 대한 장점이 있지만 에너지 밀도가 낮다는 단점이 있다. 에너지 저장 용량 증가에 대한 필요성이 증가하기 때문에 현재 많이 사용되고 있는 에너지 밀도가 낮은 카본 재료를 대체하기 위해서 이론 용량이 높다고 알려진 실리콘과 같은 메탈이나 주석 산화물과 같은 천이 금속 산화물에 대하여 많은 연구가 진행되고 있다. 특히 현재까지 알려진 많은 재료 중에서 가장 큰 capacity (~4,000 mAh/g)를 가지고 있다고 알려진 실리콘이 카본의 대체 재료로 많은 연구가 진행되고 있다. 그러나, Li 과 반응을 하며 약 300~400%에 달하는 부피팽창이 발생하고, 이러한 부피 팽창 때문에 충 방전이 진행됨에 따라 current collector로부터 박리되는 현상을 보여 빠른 용량 감소를 보여주고 있다. 본 연구에서는 adhesion layer를 current collector와 실리콘 전극 재료 사이에 삽입하여 충 방전 시 부피팽창에 의한 미세구조의 변화와 electrochemical 특성에 대한 영향을 알아보았다. 실험에 사용한 anode 전극은 상용 Cu foil current collector에 RF/DC magnetron 스퍼터링을 통해 다양한 종류(Ti, Ta 등)의 adhesion layer과 200 nm 두께의 Si 박막을 증착하였다. 또한 Bio-logic Potentiostat/ Galvanostat VMP3 와 WanAtech automatic battery cycler 장비를 사용하여 0.2 C-rate로 half-cell 타입의 코인 셀로 조립한 전극에 대한 충 방전 실험을 진행하였다. Adhesion layer의 사용으로 인해 실리콘 박막과 Cu current collector 사이의 박리 현상을 줄여줄 수 있었고, 충 방전 시 Cu 원자의 실리콘 박막으로의 확산을 통한 brittle한 Cu-Si alloy 형성을 막아 줄 수 있어 큰 특성 향상을 확인할 수 있었다. 또한, 리튬과 실리콘의 반응을 통한 형태와 미세구조 변화를 SEM, TEM 등의 다양한 장비를 사용하여 확인하였고, 이를 통해 adhesion layer의 사용이 전극의 특성향상에 큰 영향을 끼쳤다는 것을 확인할 수 있었다.

  • PDF

Preparation of the SiO2 Films with Low-Dit by Low Temperature Oxidation Process (저온 산화공정에 의해 낮은 Dit를 갖는 실리콘 산화막의 제조)

  • Jeon, Bup-Ju;Jung, Il-Hyun
    • Applied Chemistry for Engineering
    • /
    • v.9 no.7
    • /
    • pp.990-997
    • /
    • 1998
  • In this work, the $SiO_2$ films on the silicon substrate with different orientations were first prepared by the low temperature process using the ECR plasma diffusion as a function of microwave power and oxidation time. Before and after thermal treatment, the surface morphology, Si/O ratio from physicochemical properties, and the electrical properties of the oxide films were also investigated. The oxidation rate increased with microwave power, while surface morphology showed the nonuniform due to etching. The film quality, therefore, was lowered with increasing the defect by etching and the content of positive oxide ions in the oxide films from bulk by higher self-DC bias. The content of positive oxide ions in the oxide films with different Si orientations showed Si(100) < Si(111) < poly Si. The defects in $Si/SiO_2$ interface of $SiO_2$ film could be decreased by annealing, while $Q_{it}$ and $Q_f$ were independent of thermal treatment and the dependent on concentration of reactive oxide ions and self-DC bias of substrate. At microwave power of 300, and 400 W, the high quality $SiO_2$ film that had lower surface roughness and defect in $Si/SiO_2$ interface was obtained. The value of interface trap density, then, was ${\sim}9{\times}10^{10}cm^{-2}eV^{-1}$.

  • PDF

Study on of Process Parameters for Adsorption of Reactive Orange 16 Dye by Activated Carbon (활성탄에 의한 Reactive Orange 16 염료 흡착에 대한 공정 파라미터 연구)

  • Lee, Jong Jib
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.7
    • /
    • pp.667-674
    • /
    • 2020
  • The adsorption of reactive orange 16 (RO 16) dye by activated carbon was investigated using the amount of adsorbent, pH, initial concentration, contact time and temperature as adsorption variables. The investigated process parameters were separation coefficient, rate constant, rate controlling step, activation energy, enthalpy, entropy, and free energy. The adsorption of RO 16 was the highest at pH 3 due to the electrostatic attraction between the cations (H+) on the surface of the activated carbon and the sulfonate ions and hydroxy ions possessed by RO 16. Isotherm data were fitted into Langmuir, Freundlich and Temkin isotherm models by applying the evaluated separation factor of Langmuir (RL=0.459~0.491) and Freundlich (1/n=0.398~0.441). Therefore, the adsorption operation of RO 16 by activated carbon was confirmed as an appropriate removal method. Temkin's adsorption energy indicated that this adsorption process was physical adsorption. The adsorption kinetics studies showed that the adsorption of RO 16 follows the pseudo-second-order kinetic model and that the rate controlling step in the adsorption process was the intraparticle diffusion step. The positive enthalpy change indicated an endothermic process. The negative Gibbs free energy change decreased in the order of -3.16 <-11.60 <-14.01 kJ/mol as the temperature increased. Therefore, it was shown that the spontaneity of the adsorption process of RO 16 increases with increasing temperature.