• Title/Summary/Keyword: 화재 유동해석

Search Result 138, Processing Time 0.023 seconds

The Comparative Analysis of Fire-Driven Flow Simulation for Dae-gu Subway Station Using FDS and Fluent. (FDS 및 FLUENT를 이용한 대구지하역사 화재유동 해석비교)

  • Jang, Yong-Jun;Lee, Chang-Hyun;Kim, Hag-Beom;Kim, Jin-Ho
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.50-55
    • /
    • 2008
  • The comparative analysis of fire-driven flow simulation for Dae-Gu subway station was performed using FDS and Fluent. The boundary condition was obtained from analyzed data for Dae-Gu subway fire accident which had been outbreaked in 2003 year. The smoke flow in the second and third basement has been analyzed. The CO and temperature distribution in the train units and station platform have been obtained with FDS and FLUENT and compared with each other. Total simulation time is 600s and the results are compared of each 10sec The analyzed data will be applied to the passenger evacuation simulation for Dae-Gu subway station and used to optimal design method.

  • PDF

Application of Numerical Model for the Effective Design of Large Scale Fire Calorimeter (화재발열량계의 효율적 설계를 위한 수치해석 모델의 적용)

  • Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.28-33
    • /
    • 2010
  • The present study develops a numerical model based on the computational fluid dynamics technique to analyse the thermal flow characteristics of large scale fire calorimeter and examine the characteristics of primary parameters affecting on the uncertainty of heat release rate measurement. ANSYS CFX version 12.1 which is a commercial CFD package is used to solve the governing equations of the thermal flow field and the eddy dissipation combustion model and P-1 radiation model are applied to simulate the fire driven flow. The numerical results shows that the horizontal duct system with $90^{\circ}$ bend duct was shown relatively high deviated asymmetric flow profiles at the sampling location and the deviation of the velocity field was higher than that of the temperature and species quantities. The present study shows that the computational model can be applicable to optimize the design process and operating condition of the large scale fire calorimeter based on the understanding of the detail flow field.

Numerical Simulation on Smoke Movement in Multi-Compartment Enclosure Fires under Pressurized Air Supply Conditions (급기가압 조건에서 복합 구획 공간 화재의 연기 거동에 대한 수치해석 연구)

  • Ko, Gwon Hyun
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.15-21
    • /
    • 2018
  • This study examined the flow characteristics of fire smoke under pressurized air ventilation conditions by carrying out fire simulations on multi-compartment enclosure, including room, ancillary room and stair case. Fire simulations were conducted for the air-leakage test facility, which was constructed to measure the effective leakage area and aimed to improve the understandings of fire and smoke movement by analyzing the overall behaviors of fire smoke flow and pressure distributions of each compartment. The simulation results showed that the heat release rate of the fires was controlled sensitively by the amount of air supplied by the ventilation system. An analysis of the velocity distributions between the room and ancillary room showed that fire smoke could be leaked to the ancillary room through the upper layer of the door, even under pressurized air supply conditions. From these results, it was confirmed that the fire size and spatial characteristics should be considered for the design and application of a smoke control system by a pressurized air supply.

Numerical models for hydrodynamic flows in FDS (유동해석에 있어서의 FDS의 수치모델)

  • Lee, Ju-Hee;Kim, Dong-Eun;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.139-142
    • /
    • 2011
  • 오픈 소스인 FDS(fire dynamic simulator)는 건물, 터널내의 화재나 연기, 열기류의 거동을 연구하기 위하여 국내외적으로 광범위하게 이용되고 있다. 소스코드 또한 공개 되어 있어 그 활용범위가 더욱 넓어지고 있다. 대부분의 기본적인 화재, 방재 해석을 위한 모델들을 제공하고 있으나 이를 더욱 발전시키고 새로운 알고리즘의 적용하기 위해서는 이러한 모델의 구조를 잘 이해할 필요가 있다. 본 연구에서는 이러한 FDS모델을 더욱 확장하기 위한 일환으로 현 FDS의 기본적인 구조를 검증모델(verification)을 이용하여 파악하고 이를 향후 소스코드를 확장할 수 있는 근간으로 삼고자 한다.

  • PDF

A Study on the Flow Characteristics of the Spray Nozzle (관창의 유동특성에 관한 연구)

  • 이동명
    • Fire Science and Engineering
    • /
    • v.17 no.3
    • /
    • pp.55-60
    • /
    • 2003
  • This study established analysis theory for flow characteristics prediction of the spray nozzle and predicted discharge and discharge type of the spray nozzle from numerical analysis. It could know that discharge type of the spray nozzle from prediction data determine to position of nozzle and needle, and flow characteristics prediction of the spray nozzle could know that the characteristics according to shape of nozzle and needle is decided. New model of the spray nozzle that can maximize efficiency of fire suppression from flow characteristics and prediction data of the spray nozzle is presented. The result of this study utilize to data necessary to develop new model of the spray nozzle. Also the result of this study wish to contribute to resource technology security of the spray nozzle, technique ripple effect enlargement of same kind industry and technical development activation of fire protection field etc.

Post-Fire Damage and Structural Performance Assessment of a Steel-Concrete Composite Bridge Superstructure Using Fluid-Structure Interaction Fire Analysis (FSI 화재해석을 이용한 강합성 교량 상부구조의 화재 후 손상 및 구조성능 평가)

  • Yun, Sung-Hwan;Gil, Heungbae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.627-635
    • /
    • 2021
  • The fire damage and structural performance of a steel-concrete composite superstructure under a highway bridge exposed to fire loading was evaluated. To enhance the accuracy and efficiency of the numerical analysis, a proposed fluid-structure interaction fire analysis method was implemented in Ansys Fluent and Ansys Mechanical. The temperature distribution and performance evaluation of the steel-concrete composite superstructure according to the vertical distance from the fire source to the bottom flange were evaluated using the proposed analysis method. From the analysis, the temperature of the concrete slab and the bottom flange of the steel-concrete composite superstructure exceeded the critical temperature. Also, when the vertical distance from the fire source was 13 m or greater, the fire damage of the steel-concrete composite superstructure was found to within a safe limit.

BGK 수치기법을 이용한 로켓 노즐 내의 유동장 해석

  • 신동신;이재성
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.16-16
    • /
    • 2000
  • 충격파를 포함하는 초음속 유동을 해석하는 수치해법 중에서 많이 사용되어진 것은 엄밀 및 근사 리만 해법과 플럭스 분할 기법들로서 이들은 Euler 방정식에 기반을 두고 선형 또는 비선형파의 상호작용을 풍상 차분법으로 기술하는 방법들이다. 이러한 수치기법들은 과거 광범위하게 사용되어 왔으나 최근 여러 가지 단점이 발견되었다. 이와 같은 문제점을 극복하고자 입자의 통계적인 운동을 기술하는 기체 운동론에 근거하여 BGK 수치기법이 제시되었다. 이는 비충돌 볼츠만 방정식으로부터 입자의 수준에서 플럭스 분할 기법 형태의 풍상차분법을 구현하는 것으로 볼츠만 방정식의 충돌항을 BGK 모델로 대치하고 이것의 적분해로부터 수치 플럭스를 구한다. 이 수치기법은 기존의 리만해법에 비하여 수치적으로나 물리적으로 매우 타당한 성질인 강건성, 정확성, 엔트로피 조건, 양수보존성 등을 가지고 있음이 밝혀졌다. 이와 같은 수치기법을 사용하여 로켓 노즐 내의 아음속, 천이음속, 초음속에서의 유동장 해석을 위한 프로그램을 작성하였다. 시간 적분에 대하여는 정상 상태의 계산을 위하여 내재적 시간 적분 방법을 사용하였으며, 공간 이산화 방법으로는 임의의 제어체적에 대하여 적분형 보존 방정식을 적용하는 유한 체적법을 사용하였다. 초음속 입구 유동과 출구에서 초음속과 저음속 유동의 두가지 경우를 고려하여 얻은 결과를 기존의 연구 결과와 비교하여 본 결과 잘 일치하였다. 입구 유동이 저음속이고 출구 유동이 초음속인 경우에 대하여도 해석결과가 실험결과와 잘 일치하였다. 상대적으로 낮은 온도, 압력 조건과 높은 온도, 압력 조건을 가지는 고체 로켓 모터 노즐 내의 유동을 해석하였다. 이들 해석 결과를 전압, 전온도로 표준화시킨 결과 서로 일치하였으며, 파라서 저온, 저압에서 얻은 결과도 표준화시킬 경우, 고온, 고압에서도 사용될 수 있음을 알 수 있었다.의 영향에 초점을 맞추었다.다고 판단되며 배기 가스 자체에 대기 공기중에 함유되어 있던 습기가 얼어붙는(Icing화) 문제가 발생하기 때문에 배기가스의 Icing을 방지하기 위하여 압축기 끝단에서 공기를 추출하여 배기부분에 송출할 필요성이 있는 것으로 판단되었다. 출구가스의 기체 유동속도가 매우 빠르므로 (100-l10m.sec) 이를 완화하기 위한 디퓨저의 설계가 요구된다고 판단된다. 또 연소기 후방에 물을 주입하는 경우 열교환기 및 기타 부분품에 발생할 수 있는 부식 및 열교환 효율 저하도 간과할 수 없는 문제로 파악되었다. 이러한 기술적 문제가 적절히 해결되는 경우 비활성 가스 제너레이터는 민수용으로는 대형 빌딩, 산림, 유조선 등의 화재에 매우 적절히 사용되어 질 수 있을 뿐 아니라 군사적으로도 군사작전 중 및 공군 기지의 화재 그리고 지하벙커에 설치되어 있는 고급 첨단 군사 장비 등의 화재 뿐 아니라 대간첩작전 등에 효과적으로 활용될 수 있을 것으로 판단된다.가 작으며, 본 연소관에 충전된 RDX/AP계 추진제의 경우 추진제의 습기투과에 의한 추진제 물성 변화는 미미한 것으로 나타났다.의 향상으로, 음성개선에 효과적이라고 사료되었으며, 이 방법이 편측 성대마비 환자의 효과적인 음성개선의 치료방법의 하나로 응용될 수 있으리라 생각된다..7%), 혈액투석, 식도부분절제술 및 위루술·위회장문합술을 시행한 경우가 각 1례(2.9%)씩이었다. 13) 심각한 합병증은 9례(26.5%)에서 보였는데 그중 식도협착증이 6례(17.6%), 급성신부전증 1례(2.9%), 종격동기흉과 폐염이 병발한 경우와 폐염이 각 1례(2.9%)였다. 14) 식도경 시행회수는 1회가 17례(54.8%), 2회가 9례(29.0%), 3회 이상이 5례(16.1%)였다.EX>$IC_{50}$/ 값이 210 $\mu\textrm{g}$<

  • PDF

Multi-dimensional Fire Behaviors in an Under-ventilated Compartment Fire (환기부족 구획화재에서 다차원 화재거동)

  • Hwang, Cheol-Hong;Park, Chung-Hwa;Ko, Gwon-Hyun;Lock, Andrew
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.37-42
    • /
    • 2010
  • 실제 규모 ISO 9705 표준 화재실에서 과환기(over-ventilated) 및 환기부족(under-ventilated) 화재에 대한 열 및 화학적 특성에 관한 실험이 수행되었다. 또한 FDS(Fire Dynamic Simulator)를 이용하여 수치적 예측성능에 대한 평가와 환기부족화재에서 건물 내부의 다차원 화재현상에 대한 해석이 이루어졌다. 과환기 및 환기부족화재의 특성은 연소효율, 총괄 당량비 뿐만 아니라 고온 상층부의 온도분포, 연소 생성물의 농도에 의해 명확하게 구분되었다. 실험결과와의 비교를 통해 과환기 및 환기부족화재에서 FDS는 공간내부의 온도, 열유속 및 다양한 화학종의 분포를 정량적으로 잘 예측함을 확인하였다. 과환기화재와 비교할 때, 환기부족화재에서 내부유동은 반대방향의 다차원 재순환 유동구조를 갖고 있음을 발견하였다. 동시에 공간내부의 $O_2$ 및 CO의 분포 역시 다차원 구조를 갖기 때문에 기존화재연구에서 측정되는 고온 상층부의 열 및 화학적 특성은 환기부족화재를 이해하는데 많은 한계가 있음을 확인하였다.

  • PDF

A Study on Fluid Flow Analysis of High Pressure Positive Displacement Pump without Clearance (클리어런스가 없는 초고압 회전용적형 헬리컬기어 펌프의 유동해석에 관한 연구)

  • Min, Se-Hong;Kim, Ho-Chul
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.33-38
    • /
    • 2015
  • For the purpose of high-pressure and suction of fixed amount, the development of ultra-high pressure rotating helical gear positive displacement pump with no clearance had been proceeded. The CFD analysis was performed to verify the internal pressure and the discharge flow velocity of the pump. Accordingly, a flow analysis were performed by FVM technique and we were unable to obtain a successful result since the fluid domain is separated because the grid is not configured in a row in FVM flow analysis of the fully enclosed type without clearance. Because of these problems, the flow analysis was performed by MPS method which grid configuration is not needed and the internal pressure and the discharge flow velocity of the pump were confirmed through the MPS flow analysis. At 1,000 rpm rotation speed of the rotor, the minimum internal pressure of the pump was 19.5 bar, maximum pressure was 44.6 bar and average pressure was 33.9 bar. And the minimum discharge flow velocity was 64.5 m/s, maximum discharge flow velocity was 84.8 m/s and average discharge flow velocity was 76.1 m/s. Through this study, we could confirm that MPS method was more suitable than FVM method in terms of flow analysis with no clearance. In addition, the relationship of the flow velocity according to the change of ultra-high pressure rotating helical gear positive displacement pump could be identified through this study.

Experimental and Numerical Studies on Heat/Smoke Behavior due to a Fire on Underground Subway Platform (I) - Experimental Approach - (지하철 역사 승강장 화재발생시 열/연기 거동 분석을 위한 실험 및 수치 연구(I) - 실험적 접근 -)

  • Park, Won-Hee;Kim, Dong-Hyeon;Chang, Hee-Chul;Kim, Tae-Kuk
    • Fire Science and Engineering
    • /
    • v.20 no.3 s.63
    • /
    • pp.9-14
    • /
    • 2006
  • In this study boundary velocity which is one of the important boundary conditions for numerical simulation for subway station on fire are experimentally obtained. The tests were conducted according to its operating mode of the ventilation systems in the platform: smoke extraction ventilation mode in occurrence of fire and normal ventilation mode for air conditioning. Velocities are measured at various points on the platform. To examine smoke extraction and air supply capacity in the platform level, air velocities were checked on opening vents. Numerical analysis under normal ventilation mode without fire is conducted by using measured boundary conditions, and the numerical results are compared with the measured velocities on the platform.