화재 발생 지하철 역사에서의 여객 대피 해석에 관한 연구 (A Numerical Study on Passengers' Evacuation in a subway station in case of Fire Occurrence)

  • 김치겸;이성원;허남건;남성원
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.142-147
    • /
    • 2009
  • In the present study, a numerical simulation of passenger evacuation in a subway station was performed. Algorithm for passenger flow analysis based on DEM(Discrete Element Method) has been improved to simulate passenger flow in detailed geometry. The effect of grid density was assessed in the present study to show the advantage of using finer grid in the simulation. The method of coupling passenger flow and fire simulation has also been investigated to analyze passenger evacuation flow under fire. In this method the CO distributions in the subway station was used to assess fire hazards of passenger by means of FED(Fractional Effective Dose) model. Using the coupled algorithm a simulation for passenger evacuation flow and fire analysis were performed simultaneously in the simplified subway station. This algorithm could be used in the design of subway station for the purpose of passengers' safety in case of fire.

  • PDF

화재 발생 지하철 역사에서의 여객 대피 해석에 관한 연구 (A Numerical Study on Passenger Evacuation in a Subway Station in Case of Fire Occurrence)

  • 김치겸;이성원;허남건;남성원
    • 설비공학논문집
    • /
    • 제22권8호
    • /
    • pp.509-514
    • /
    • 2010
  • A numerical simulation of passenger evacuation in a subway station was performed by coupling the passenger flow analysis and the fire simulation. The algorithm of the passenger flow analysis was based on a DEM (Discrete Element Method) using the potential map of the direction vector for each passenger. This algorithm was improved in the present study as to use finer grid smaller than a passenger in order to resolve detailed geometry of the station and to resolve the behavior of passengers in the bottleneck at the ticket gate considering the collision of passengers to a wall or with other passengers. In the fire simulation, the CO distribution predicted by using CFD was used to take into account the effect of toxic gases on the passengers' mobility. The methodology proposed in the present study could be used in designing safer subway station in case of fire occurrence.

유한요소 신뢰성 해석을 통한 액체저장탱크의 지진 취약도 평가 (Seismic Fragility Assessment of Liquid Storage Tanks by Finite Element Reliability Analysis)

  • 이상목;이영주
    • 한국산학기술학회논문지
    • /
    • 제18권4호
    • /
    • pp.718-725
    • /
    • 2017
  • 액체저장탱크는 화학물질을 다루는 산업단지의 주요한 구조물로서, 지진으로 인한 구조물의 손상은 화학물질의 유출, 화재, 폭발 등의 추가적인 피해를 야기한다. 따라서 액체저장탱크의 지진 취약성을 사전에 효율적으로 평가하고, 지진에 대비하는 일이 필수적이라고 할 수 있다. 지진으로 인해 진동하는 액체저장탱크는 액체-구조물의 상호작용으로 탱크 벽체에 유동압력이 작용하며, 이는 탱크의 응력을 증가시키고 구조적 손상을 일으키는 원인이 될 수 있다. 한편, 구조물의 지진 취약성은 여러 불확실성 요인들을 고려하여 정해진 한계상태에 대한 파괴확률을 산정함으로써 평가하게 되는데, 보다 정확한 액체저장탱크 지진 취약도 평가를 위해서는 신뢰성 해석 과정에서 정교한 유한요소 해석이 요구된다. 따라서 본 연구에서는 최근에 신뢰성 해석 소프트웨어와 유한요소 해석 소프트웨어를 서로 연동시켜 개발된 FERUM-ABAQUS를 활용한 유한요소 신뢰성 해석을 통해 액체저장탱크의 파괴확률을 계산하였다. 이러한 유한요소 신뢰성 해석 기법은 두 소프트웨어 간의 자동적인 데이터 교환이 가능하여 보다 효율적으로 구조물의 지진 취약성을 평가할 수 있으며, 이를 통해 얻은 파괴확률 결과를 바탕으로 지진 강도에 따른 액체저장탱크의 지진 취약도 곡선을 성공적으로 도출하였다.

수직벽 화재 자연대류에 의한 난류 경계층 열유동 특성 해석 (ANALYSIS OF TURBULENT BOUNDARY LAYER OF NATURAL CONVECTION CAUSED BY FIRE ALONG VERTICAL WALL)

  • 장용준;김진호;류지민
    • 한국전산유체공학회지
    • /
    • 제21권4호
    • /
    • pp.1-10
    • /
    • 2016
  • The analysis of characteristics of turbulent flow and thermal boundary layer for natural convection caused by fire along vertical wall is performed. The 4m-high vertical copper plate is heated and kept at a uniform surface temperature of $60^{\circ}C$ and the surrounding fluid (air) is kept at $16.5^{\circ}C$. The flow and temperature is solved by large eddy simulation(LES) of FDS code(Ver.6), in which the viscous-sublayer flow is calculated by Werner-Wengle wall function. The whole analyzed domain is assumed as turbulent region to apply wall function even through the laminar flow is transient to the turbulent flow between $10^9$<$Gr_z$<$10^{10}$ in experiments. The various grids from $7{\times}7{\times}128$ to $18{\times}18{\times}128$ are applied to investigate the sensitivity of wall function to $x^+$ value in LES simulation. The mean velocity and temperature profiles in the turbulent boundary layer are compared with experimental data by Tsuji & Nagano and the results from other LES simulation in which the viscous-sublayer flow is directly solved with many grids. The relationship between heat transfer rate($Nu_z$) and $Gr_zPr$ is investigated and calculated heat transfer rates are compared with theoretical equation and experimental data.

균일배기 환기방식에서의 배연특성에 관한 연구 (A Study on the Effective Fire and Smoke Control in Semi-Transverse Ventilation)

  • 전용한;김종윤;서영호;유지오;한상필
    • 한국화재소방학회논문지
    • /
    • 제24권1호
    • /
    • pp.90-94
    • /
    • 2010
  • 본 연구에서는 횡류환기방식의 균일배기방식(balanced exhaust)에 대한 터널 내 풍속, 배연풍량에 따른 수치해석을 수행하여 연기의 이동거리를 분석하고 기존의 유동가시화 실험결과와 비교하였다. 그 결과 균일배기방식의 배연시스템에서는 풍속이 존재하지 않는 경우 배연풍량을 연기발생량(Vc = 0)일 때 건설교통부의 도로터널방재시설 지침에 의한 피난연결통로의 간격 250m 이내로 연기가 제한되었으며, 배연효율은 본 실험범위에서 55.1%에서 95.8%로 나타났다. 터널 내 풍속이 존재하면 연기를 배연하기 위한 배연풍량이 급격하게 증가하는 경향을 보이는 것으로 알 수 있으며, 배기구의 풍속이 증가하면 배연효율이 감소하며, 연기의 이동거리를 목표로 하는 거리로 제한하기 위해서 배연풍량은 연기발생량 보다 최대 1.8배에서 1.04배까지 증대하는 것으로 나타나고 있다. 본 연구에서 평가기준으로 선정한 250m 이내로 연기의 이동거리를 제한하기 위한 배연풍량은 터널 내 풍속이 존재하지 않는 경우에는 배연풍량은 최소 $84m^3/s{\cdot}250m$, 1.75m/s인 경우에 배연풍량은 최소 $393m^3/s{\cdot}250m$($Q_E$= 80 + 5Ar)으로 나타났다.

풍력발전기용 밀폐형 변압기의 식물성 절연유에 대한 열적특성 연구 (Thermal Analysis of Vegetable Insulation Oil for Hermetically Sealed Wind Turbine Transformer)

  • 이성원;이준엽;김준수;우재희;김동해
    • 대한기계학회논문집B
    • /
    • 제36권1호
    • /
    • pp.97-102
    • /
    • 2012
  • 변압기 외부에 방열핀을 설치한 밀폐형 오일변압기는 절연유의 온도상승으로 인해 부피가 팽창할 경우 방열핀의 내부 부피가 확장되어 압력상승을 방지한다. 본 연구에서는 생분해도가 높아 환경친화적 이고, 인화점 및 발화점이 높아 화재의 위험도가 낮은 식물성 절연유를 이용하여 당사 풍력발전기에 적용할 밀폐형 오일변압기를 개발하였다. 열 유동 전산수치해석 기법을 이용하여 식물성 절연유 냉각성능을 광유 및 실리콘유와 비교 분석 하였으며, 밀폐형 오일변압기의 개발을 위하여 변압기 중신부의 열적 안전성을 확보하고 절연유의 온도변화에 따른 내부 압력변화에 대응이 가능한 팽창형 방열핀을 개발하였다. 추가로 온도상승시험을 통하여 수치해석 결과와 시험 결과를 비교 분석 하였으며, 식물성 절연유를 사용한 밀폐형 오일 변압기의 설계 고려사항을 도출하였다.

수치해석을 통한 반밀폐공간 내 수소가스 누출 시 농도변화에 관한 연구 (Numerical analysis study on the concentration change at hydrogen gas release in semi-closed space)

  • 백두산;김효규;박진욱;유용호
    • 한국터널지하공간학회 논문집
    • /
    • 제23권1호
    • /
    • pp.25-36
    • /
    • 2021
  • 온실가스 배출량을 줄이기 위해 내연기관 자동차에 대한 제한을 두고, 친환경자동차 보급 확대 정책을 내놓고 있다. 수소 전기자동차의 수소는 가연 범위 및 폭발 범위가 넓고, 폭발화염 전파속도가 매우 빠른 가연성 가스이기 때문에, 제조, 수송, 저장 시 누출, 확산, 점화 및 폭발 등의 위험성을 가지고 있다. 수소전기자동차의 연료탱크에는 폭발 등 위험성을 감소시키기 위해 온도감응식 압력방출장치(Thermally activate Pressure Relief Device, TPRD)가 있어, 사고가 발생했을 경우 폭발, 화재 등이 발생하기 전에 탱크 내부의 수소를 밖으로 방출한다. 그러나 지하주차장이나 터널과 같은 반밀폐공간에서 사고가 발생할 경우 공간 내 기류의 유동이 개방된 공간보다 미미하기 때문에 TPRD로부터 방출된 수소가스의 농도가 폭발하한계 이상으로 누적될 수 있는 등 문제가 발생할 수 있다. 따라서 본 연구에서는 TPRD의 노즐의 직경에 따라 시간에 따른 수소의 누출 유량을 분석하고, 반밀폐공간에서 수소가 누출될 경우 수소 농도변화를 수치해석으로 검토하였다. 노즐의 직경은 1 mm, 2.5 mm, 5 mm로 검토를 하였으며, 노즐 직경에 따라 지하주차장 내의 수소농도는 노즐의 직경이 클수록 빠른 시간에 농도가 높아지며, 최대값 또한 노즐 직경이 클수록 큰 것으로 분석되었다. 기류가 정체된 지하주차장에서는 노즐 주변에서 폭발하한계 이상의 수소 농도가 분포하는 것으로 분석되었으며, 폭발상한계를 넘지는 않는 것으로 분석되었다.

멤브레인형 LNG선박 화물탱크 벤트 마스트 출구에서의 BOG 확산 특성에 관한 연구 (An Examination on the Dispersion Characteristics of Boil-off Gas in Vent Mast Exit of Membrane Type LNG Carriers)

  • 강호근
    • 해양환경안전학회지
    • /
    • 제19권2호
    • /
    • pp.225-231
    • /
    • 2013
  • 일반적으로 액체가스운반선은 인화성 화물이나 독성물질을 운반한다. 이러한 화물들은 폭발, 화재 및 인명손상을 가져올 수 있기 때문에, 액체가스운반선의 거주구역, 서비스 구역 및 통제실은 가스의 유입이 원천적으로 차단되도록 설계한다. 이러한 이유로, IMO IGC 코드의 멤브레인형 LNG선박의 화물탱크에 설치되는 벤트 출구의 높이는 노출갑판상 B/3 또는 6m 중 큰 것 이상으로 하고 작업구역 및 전후부 통행로, 갑판상의 저장탱크 및 화물설계 액위보다 6m 이상 높게 설치하여야 한다라고 규정하고 있다. 또한 LNG 시장이 점진적으로 증가하면서, LNG선박의 크기도 증가해 왔다. 때문에 현 규정에 의하면 LNG선박의 벤트의 높이는 선박 폭(B)에 비례하기 때문에 상당히 높아져야 할 것이며, 이는 높은 벤트 마스트(Mast)로 인하여 작업의 어려움 및 전방 시야를 방해하는 등 항해의 어려움을 초래한다. 본 연구에서는 멤브레인형 LNG선의 Sea-trial시에 측정하였던 데이터 및 CFD유동해석을 통해 LNG선박 화물탱크의 벤트 출구의 높이에 대한 적합성 평가를 수행한다.