• Title/Summary/Keyword: 화재 발생 감지

Search Result 250, Processing Time 0.029 seconds

Design and Verification of Addressable Automatic Fire Detection System for Existing Apartments (기존아파트의 적용성을 고려한 주소형 자동화재탐지설비의 설계 및 검증)

  • An, Hyunsung
    • Land and Housing Review
    • /
    • v.13 no.4
    • /
    • pp.105-114
    • /
    • 2022
  • Non-fire activated fire alarms caused by such actions as cigarette smoke, cooking, and high humidity are fire safety risk factors. In such instances, it is important to quickly locate and replace the actuated detector. However, it is difficult to locate those detectors because most do not have an address function. While new apartments can incorporate addressable fire alarm detectors, in existing apartments there are limitations in converting over to addressable detectors due to cost and power line issues. This study developed an efficient address function for fire alarms in existing apartments. The newly developed system consists of the existing receiver, and a proposed addressable repeater and detector. Utilizing an experimental setup, the performance of the proposed address monitoring system was confirmed to be stable and compatible with the receiver and existing detectors.

Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels (지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.135-147
    • /
    • 2015
  • Recent underground common utility tunnels are underground facilities for jointly accommodating more than 2 kinds of air-conditioning and heating facilities, vacuum dust collector, information processing cables as well as electricity, telecommunications, waterworks, city gas, sewerage system required when citizens live their daily lives and facilities responsible for the central function of the country but it is difficult to cope with fire accidents quickly and hard to enter into common utility tunnels to extinguish a fire due to toxic gases and smoke generated when various cables are burnt. Thus, in the event of a fire, not only the nerve center of the country is paralyzed such as significant property damage and loss of communication etc. but citizen inconveniences are caused. Therefore, noticing that most fires break out by a short circuit due to electrical works and degradation contact due to combustible cables as the main causes of fires in domestic and foreign common utility tunnels fire cases that have occurred so far, the purpose of this paper is to scientifically analyze the behavior of a fire by producing the model of actual common utility tunnels and reproducing the fire. A fire experiment was conducted in a state that line type fixed temperature detector, fire door, connection deluge set and ventilation equipment are installed in underground common utility tunnels and transmission power distribution cables are coated with fire proof paints in a certain section and heating pipes are fire proof covered. As a result, in the case of Type II, the maximum temperature was measured as $932^{\circ}C$ and line type fixed temperature detector displayed the fire location exactly in the receiver at a constant temperature. And transmission power distribution cables painted with fire proof paints in a certain section, the case of Type III, were found not to be fire resistant and fire proof covered heating pipes to be fire resistant for about 30 minutes. Also, fire simulation was carried out by entering fire load during a real fire test and as a result, the maximum temperature is $943^{\circ}C$, almost identical with $932^{\circ}C$ during a real fire test. Therefore, it is considered that fire behaviour can be predicted by conducting fire simulation only with common utility tunnels fire load and result values of heat release rate, height of the smoke layer, concentration of O2, CO, CO2 etc. obtained by simulation are determined to be applied as the values during a real fire experiment. In the future, it is expected that more reliable information on domestic underground common utility tunnels fire accidents can be provided and it will contribute to construction and maintenance repair effectively and systematically by analyzing and accumulating experimental data on domestic underground common utility tunnels fire accidents built in this study and fire cases continuously every year and complementing laws and regulations and administration manuals etc.

공동주택용 국내.외 감지기의 설치 및 시험 기준 비교

  • Son, Bong-Se;Lee, Chae-Won
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.67-68
    • /
    • 2013
  • 본 연구는 국내 전체 화재발생 건수에서 가장 높은 비율을 차지하고 있는 주거공간에 대한 화재 및 인명안전의 개선 대책에 관한 기초연구이다. 주거공간은 다른 어떠한 방호공간보다 가장 높은 수준의 안전이 요구되는 소방대상물이다. 국내의 주거공간을 대표하는 공동주택의 안전을 확보하는데 가장 중요한 역할을 하는 것이 화재감시시스템이며 이를 구성하는 요소 중에서도 감지기의 성능이 가장 중요한 역할을 한다. 감지기의 성능은 인간의 두뇌와 같은 기능을 하기 때문이다. 이미 일본의 경우는 공동주택 전용의 화재감시시스템을 개발하고 기준으로 제정하여 널리 보급하고 있는 실정이다. 또한 미국은 공동주택 전용의 화재감시시스템이 별도로 존재하지는 않지만 화재특성 및 화재하중 등에 대한 시험을 통해 다양한 방호공간을 효율적으로 적용할 수 있도록 상세한 코드가 정립되어 있다. 따라서 본 연구에서는 국내 공동주택에 적합한 전용 화재감시시스템을 개발하는데 필요한 기초 연구로서 국내와 방재선진외국의 감지기 설치 및 성능을 검증하는데 필요한 설치 및 시험 기준에 대하여 조사하였다.

  • PDF

Deep learning based optimal evacuation route guidance system in case of structure fire disaster (딥러닝 기반의 구조물 화재 재난 시 최적 대피로 안내 시스템)

  • Lim, Jae Don;Kim, Jung Jip;Hong, Dueui;Jung, Hoekyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.11
    • /
    • pp.1371-1376
    • /
    • 2019
  • In case of fire in a structure, it is difficult to suppress fire because it can not accurately grasp the location of fire in case of fire. In this paper, we propose a system algorithm that can guide the optimal evacuation route in case of deep learning-based (RNN) structure disaster. The present invention provides a service to transmit data detected by sensors to a server in real time by using installed sensor, to transmit and analyze information such as temperature, heat, smoke, toxic gas around the sensor, to identify the safest moving path within a set threshold, to transmit information to LED guide lights and direction indicators in a structure in real time to avoid risk factors. This is because the information of temperature, heat, smoke, and toxic gas in each area of the structure can be grasped, and it is considered that the optimal evacuation route can be guided in case of structure disaster.

Design and Implementation of A effective Complex Fire Detector Module (효과적인 복합 소방 관제 모듈의 설계 및 구현)

  • Kong, Byung-Chul;Lee, Sun-Heum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.1079-1084
    • /
    • 2010
  • Existing fire detector modules providing a simple fire alarm function have many drawbacks such as high installation, management and maintenance costs, and low scalability. In this paper, an add-on type complex fire detector module with high scalability and functions of examining the receiving units for fire sensors and itself has been developed, which enhances the reliability, stability, and economic feasibility of the existing fire detector modules. Information on when and where fire occurs, provided by the developed module, enables people to extinguish the fire immediately and minimize the damage of lives and property and also to systematically manage the fire-fighting related history and contribute to the prevention of fire.

Research on Overheat Protection Techniques of Connection Parts of MCCB by Poor Contact (MCCB 단자 접속부의 접촉불량에 의한 과열사고 방지기법에 관한 연구)

  • Kim, Dong-Woo;Lee, Ki-Yeon;Moon, Hyun-Wook;Kim, Hyang-Kon;Cho, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.54-60
    • /
    • 2008
  • In this study, damage characteristics of MCCB and terminal block due to poor contact were analyzed, and various poor contact detection techniques were suggested. Firstly, the detection techniques using thermocouple and infrared thermal camera were analyzed respectively. Also, thermo-cap during poor contact detected abnormal status effectively by changing its color, and the detection system using an odor detector and odor capsules was analyzed. Lastly, poor contact detection screw was made using characteristics of fusible alloy, and we applied the poor contact detection screw to terminal block. The above methods could prevent electrical fire caused by poor contact effectively if they are used properly.

Fabrication of smart alarm service system using a tiny flame detection sensor based on a Raspberry Pi (라즈베리파이 기반 미소 불꽃 감지를 이용한 스마트 경보 서비스 시스템 구현)

  • Lee, Young-Min;Sohn, Kyung-Rak
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.9
    • /
    • pp.953-958
    • /
    • 2015
  • Raspberry Pi is a credit card-sized computer with support for a large number of input and output peripherals. This makes it the perfect platform for interaction with many different devices and for usage in a wide range of applications. When combined with Wi-Fi, it can communicate remotely, therefore increasing its suitability for the construction of wireless sensor nodes. In addition, data processing and decision-making can be based on artificial intelligence, what is performed in developed testbed on the example of monitoring and determining the confidence of fire. In this paper, we demonstrated the usage of Raspberry Pi as a sensor web node for fire-safety monitoring in a building. When the UV-flame sensors detect a flame as thin as that of a candle, the Raspberry Pi sends a push-message to notify the assigned smartphone of the on-site situation through the GCM server. A mobile app was developed to provide a real-time video streaming service in order to determine a false alarm. If an emergency occurs, one can immediately call for help.

A Study for Performance Improvement of Fire Detector and Sprinkler Head in Apartment Houses (공동주택 화재감지 및 소화성능개선에 관한 연구)

  • Lee, Chae-Won;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.38-44
    • /
    • 2015
  • This study suggested the problems and their improvement measures for the operation of fire detectors and sprinkler heads installed at apartment houses. According to a census on population and housing in 2010, apartment houses account for 71.6% of the total housing facilities. And by fire statistics data of the National Emergency Management Agency, approximately 25.0% of fire accidents and 46.4% of casualties occur at apartment houses every year. Therefore, this study conducted for identifying the causes and characteristics of fire to establish the fire safety improvement measures for apartment houses. And this study was carried out virtual fire simulation at domestic apartment houses. The scenario of the simulation contains a comparative analysis on the operation time of standard sprinkler heads and residential sprinkler heads, heat detectors and smoke detectors. As a result of simulation, it was found that standard sprinkler heads and heat detectors installed at the existing apartment houses should be replaced with residential sprinkler heads and smoke detectors for rapid fire suppression. In addition, sprinkler systems should be considered to be installed for excluded floor at apartment houses. Especially, it is necessary to construct remote inspect systems like advanced countries for efficiency of apartment houses safety management.

Design and Develop of Automatic Circuit Breaker fot Prevent Secondary Disasters of Fire (화재 2차 피해 예방을 위한 자동 전력 차단기의 설계 및 개발)

  • Song, Jinho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.12-14
    • /
    • 2018
  • Many posters and advertisements for fire prevention have long been known to warn of the danger of fire. The reason for this warning is that the damage of the fire is large. In addition, if the second damage occurs, the damage will be larger. In this study, we will design an automatic power circuit breaker that automatically cuts off the power if the temperature sensor is set to a certain temperature value and then goes up above that value. This study will minimize the secondary damage of fire.

  • PDF

A Study on the Characteristics of an Optical Sensor Linear Fire Detection System with Miniature Model Fire Experiment (축소 모형실험을 통한 광센서 선형 화재 감지 시스템의 특성에 관한 연구)

  • Kim, Dong-Eun;Kim, Si-Kuk;Lee, Young-Sin;Lee, Chun-Ha;Lim, Woo-Sup
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.19-26
    • /
    • 2016
  • In this study, we conducted a low temperature operating test and miniature tunnel model test to study the fire detection capability and properties of an early fire detection system using an optical sensor linear detector that can be installed in harsh environments such as tunnel or utility-pipe conduits which are becoming the major and national infrastructure facilities. The test showed that the optical sensor linear detector was the only one functioned properly among five thermal detectors installed at a low temperature of $-20^{\circ}C$ for 5 days. To study were analyzed adaptability of optical sensor linear detector in the windy tunnel, the operating properties of the optical sensor linear detector when the wind velocity was varied between 0 m/s and 1 m/s in a miniature tunnel model. The temperature change was high when the wind velocity was 0 m/s.