• Title/Summary/Keyword: 화재위험성

Search Result 1,053, Processing Time 0.027 seconds

Study on the Risk Analysis of Complex Electrical Fire by the Partial Disconnection and Tracking (반단선과 트래킹에 의한 복합적 전기화재의 위험성분석 연구)

  • Park, Sang-Min;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.111-118
    • /
    • 2017
  • The present paper is a study on the risk analysis of complex electrical fire by the partial disconnection and tracking. First, in order to analysis the single cause of electrical fire risk by the partial disconnection, the thermal characteristic has been measured by the change in the number of strands and the rated current of a wire. And then, in order to analysis the electrical fire risk by complex cause, an experiment on the accelerated tracking has been carried out in a condition of partial disconnection and confirmed the fire relation between partial disconnection and tracking. From the experiment, if the partial wire disconnection acts as a single cause, the existing thermal characteristics generated by the flowing current has appeared more clearly by the increase in the flowing current due to the complex action of tracking. Accordingly, the disconnection of strands has appeared by the complex cause due to the drastic temperature increase which was not generated in the single cause. Namely, it has been confirmed that if the partial disconnection and tracking act complexly rather than the risk of electrical fire by the existing partial disconnection, relatively its risk has been increased in large.

A Study on Fire and Explosion Index in the Petro-chemical Plant (위험성 평가중 화재.폭발 지수 산정방법에 관한 고찰)

  • 김진곤;김광일
    • Fire Science and Engineering
    • /
    • v.7 no.1
    • /
    • pp.17-29
    • /
    • 1993
  • The method has been proposed for the risk assessment of petro-chemical plant, specially which can evaluate relative risk levels on the materials and process-es. The each potential risk of materials and processes are derived numerically and combined these values, finally Fire and Explosion Index was found. Material factor was evaluated with the flammability and the reactivity and process factor with emprical factor called penalty. This F&EI can be performed for relative risk assesment at the whole plant and directely applicable at the line.

  • PDF

A Study on the Risk Assessment Using Simulation and Case Study of Urban Fire - Focusing on Market - (도시화재 사례 조사 및 시뮬레이션을 이용한 위험성 평가 - 시장지역을 중심으로 -)

  • Shin, Yi-Chul;Koo, In-Hyuk;Hayashi, Yoshihiko;Ohmiya, Yoshifumi;Kwon, Young-Jin
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.1-7
    • /
    • 2011
  • As population grows and urban facilities are concentrated in specific areas due to recent urbanization and industrialization, cities have structures vulnerable to both natural and man-made disasters. Most of these structures, whether buildings or residential houses, are left in a defenseless state if not given the appropriate check-up before they are built. The process of rapid urbanization without establishing the proper urban fire risk assessment will surely lead to disasters. This phenomenon occurred during the process of rapid urbanization and maybe said the result of chaotic urban expansion where modern urban infrastructure is not yet equipped in the city. Under the said circumstances, propagation processes of Korean urban fire cases were investigated to establish fire risk assessment system. Moreover, this paper explains the experiment performed for establishing urban risk assessment model. The said experiment was conducted using the new urban fire risk assessment model.

Guidelines for the Construction of Vulnerability Map of Fire in Seoul (서울시 화재위험지도 구축방안에 관한 연구)

  • Kang, Youg-Ok;Park, Mi-Ra
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.195-200
    • /
    • 2005
  • 도시의 안전을 위해서 재해 발생시 대응 및 복구와 같은 사후처리도 중요하지만 재해에 취약한 지역을 사전에 파악하고, 예방적 차원에서 이러한 지역들을 체계적으로 관리하는 것이 점차 중요해지고 있다. 본 연구는 대도시 관리차원에서 필요한 방재지도의 유형 중 하나로 화재를 상정하여, 화재위험지역을 선정하는 기준을 설정하고 이 기준에 맞춰 서울시 종로구 창신동을 사례지역으로 하여 화재위험지도를 시범적으로 구축하는 것을 주요 내용으로 한다 화재위험지도성은 방재업무에 있어 지역성에 기초하여 취약지구를 사전에 파악하고 체계적으로 관리하는데 활용될 수 있으며, 나아가 지구단위계획 등의 도시계획업무에서 방재를 고려한 토지이용계획 수립 및 도시계획시설 배치 등에 활용될 수 있을 것으로 판단된다.

  • PDF

Risk Evaluation of Fire and Explosion Considering the Property of Self-Reactive Materials (자기반응성물질의 화재.폭발 위험성 평가)

  • Lee, Bong-Woo;Song, Haak;Moon, Deog-In;Lee, Chang-Woo
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.364-368
    • /
    • 2011
  • 최근 급속히 발전하고 있는 과학기술과 산업발달에 따라 화학물질, 위험물의 사용, 저장 및 운송물이 날로 증가하고 있다. 이러한 물질들은 우리의 일상생활과 인류문화 발전에 크게 기여하고 있지만 인화성, 폭발성 등의 잠재위험성을 가지고 있다. 세계 각국은 물질의 분류와 표시가 달라 국제무역에서 많은 사고가 증가하고 있는 실정이다. 이 연구의 목적은 자기반응성물질의 화재 폭발 위험성을 평가하고, 국제적인 시험방법과 국내 시험방법으로 시험하여 연관성 및 상관관계를 알아보고 선진화된 시험방법을 국내실정에 적합하게 제시하는데 있다.

  • PDF

Study on the effective response method to reduce combustible metal fire (금속화재 위험감소 방안에 관한 이론적 연구)

  • Nam, Ki-Hun;Lee, Jun-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.600-606
    • /
    • 2018
  • A class D fire or combustible metal fire is characterized by the presence of burning metals. Only certain metals or metal compounds are flammable, including sodium and lithium. General fire extinguishing agents, such as dry chemical powder, water-based fire extinguish agents, and carbon dioxide, cannot be used in class D fires. This is because these agents cause adverse reactions or are ineffective. In addition, the amount of usage of combustible metals is increasing due to continuous development of the semiconductor and fuel cell industries. Despite this, Korea does not have standards and laws related to combustible metal fires. This paper suggests directions of the class D fire management policies to reduce the class D fire risk and impact by analyzing the standards and laws related to class D fires and combustible metal fire cases. The factors to make laws on class D fire prevention and response systems, and management system of dry sand were determined. These results may be used to help reduce the risk of class D fires and improve the response abilities.

An Experimental Study on the Fire Hazard of Electric Heating Pad (전기장판의 화재위험성 실험연구)

  • Lee, Bok-Young;Park, Chan-Ho;Park, Sang-Tae;Hong, Sung-Ho;Yu, Hyun-Jong
    • Fire Science and Engineering
    • /
    • v.20 no.3 s.63
    • /
    • pp.113-117
    • /
    • 2006
  • This study presents analysis of fire hazard of electrical heating pad. In order to analyze fire hazard fire experimental and flammability experiment is conducted. The fire experiment is conducted to simulate normal condition and abnormal condition such as breakdown of thermostat. Vertical burning test(UL 94) is conducted for the fire retardant experiment. Kinds of electric heating pad used for experiment are electric mat, fabric pad, vinyl pad. The results show that fire hazard is high in case of breakdown of thermostat with the rating voltage supply. And Material of electric heating pad has not fire retardant performance.

An Experimental Study on the Fire Risk of Electric Heaters According to Contact of Flammable Materials (가연물 접촉에 따른 전기히터의 화재위험성에 관한 실험적 연구)

  • Lee, Sung-Ryong
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.63-71
    • /
    • 2011
  • In this study, it was evaluated the fire risk of an electric heater as representative seasonal appliances. Two type of electric heaters were used in experiments. When electric heaters were operated, temperature variation was measured around the heater. Internal structure was understood by Nondestructive inspection. It was evaluated the tire risk of electric heaters, when flammable materials were positioned ear a heater. It was also estimated the probability of a tire in case of malfunction of a safety tip-over witch. When a heater was operated in a normal condition, temperature was maintained under $80^{\circ}C$ around the heater. The possibility of a fire is very high, when a heater is covered with flammable materials or malfunction of safety parts (safety tip-over switch, anti-overheating devices).

A Study on the Risks Factors of Fire Occurrence and Expansion for Traditional Markets (전통시장 화재 발생 및 확대 위험요인에 관한 연구)

  • Kim, Jung-Gon;Park, Chang-Il;Jung, Jae-Wook;Kim, Seong-Gon
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.60-67
    • /
    • 2021
  • Purpose: Traditional markets often have irregular space utilization patterns because the spaces are created and divided as time passed. Internally, there is high risk of fire due to problems such as aging facilities and high-density of stores and externally, there is high risk of fire spread since it is often adjacent to deteriorated residential and commercial facilities. Method: In this paper, on-site investigations were carried out to check fire risk factors and fire spread risk, and fire occurrence and expansion risk factors were investigated for traditional markets in Hwanghak-dong and Dong-daemun by using large-scale fire data from existing traditional markets. Result: As a result of the analysis, there are likely to be various problems such as high fire load and lack of safety awareness due to aging facilities and high-density of stores. In particular, it is necessary to prepare countermeasures because deteriorated residential facilities with narrow alleys around traditional markets have high fire spread. It is situation that while traditional markets mainly are managing for fire and disaster centering on the merchant association, the surrounding residential areas are not properly managed. Conclusion: It is necessary to manage deteriorated residential facilities with traditional markets, also to be linked early warning system and information to evacuate rapidly in case of fire there.