• Title/Summary/Keyword: 화재안전가이드라인

Search Result 14, Processing Time 0.02 seconds

Using AHP to Develop a Rehabilitation Room Management Model for Fire Officers at Disaster Sites (재난현장 소방공무원의 회복실 운영모델 개발)

  • Yim, Dong-Kyun;Chae, Jin
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.115-124
    • /
    • 2020
  • The purpose of this study was to provide an operational model of the rehabilitation room for fire officers at disaster sites to improve the safety and resilience of fire officers. Therefore, we analyzed the operation related elements of the rehabilitation room-such as overseas rehabilitation room operation cases and previous studies- and managed different factors including, but not limited to, management and human resources, equipment and facility, and accessibility and convenience factors; afterward, the relative importance and importance of sub-layers in each field were measured. The priority of items for the operation of the rehabilitation room for fire officers at disaster sites was elucidated; after expert analysis, it was found that human resources were the most crucial factor. Finally, it was found that, in descending order, accessibility and convenience, administrative, equipment, and facility factors were also essential. Based on this, we proposed a rehabilitation room operation guideline for disaster sites.

Study on the Management Plan for the Preparation of Chemical Terrorism in Multi-use Facilities (다중이용시설 화학테러에 대비한 관리방안 연구)

  • Yoon, Seong Yong;Kim, Si-Kuk;Hong, Sungchul
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.68-78
    • /
    • 2019
  • In modern society, the paradigm of terrorism is shifting to the form of soft targets focusing on an unspecified number of people, which is different from previous terrorist tendencies, and frequent attacks using chemicals. Therefore, this study analyzed the evacuation environment and characteristics, manual analysis of a terror response manual, and the domestic chemical management status of multi-use facilities, and proposed the following management measures for chemical terror prevention in multi-use facilities. First, a multi-use facility guideline for prompt onsite response is proposed. Second, an improvement plan is suggested through the analysis of the manual for counter terrorism. Third, integrated management is proposed through the selection of chemicals available for terrorism. Through this, it is expected that an additional improvement plan will be prepared for countermeasures against chemical terrorism in multi-use facilities. In the future, it will be necessary to analyze the problems through cases of foreign countries and take customized countermeasures.

Elevator evacuation studies using a computer program (컴퓨터프로그램을 이용한 엘리베이터 피난 연구)

  • Cha, Jong Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5525-5533
    • /
    • 2012
  • Because of ultra-high buildings or deeper underground space, recent buildings have the potential that people who have lack of physical strength collapse before arriving at the emergency exits when catastrophes occur. In case of fire, the way to escape is that first, people take the stairs of the adjacent areas and then use the elevator to the remaining distance by road to escape notice or be safe. For this reason, the skyscrapers guidelines of Seoul for information on the elevator for evacuation has been established. Nevertheless, when designing buildings to install a elevator for evacuation separately is not effective, so passenger elevators installation according to the criteria are encouraged to use as evacuation elevators. However, this does not include detailed design guidelines so far. Therefore, this study was to investigate design method to use the passenger elevator for evacuation according to the domestic law and international installation criteria, and to calculated number of lifts and refuge to use the elevator using by the ELVAC+ and PathFinder evacuation program.

Risk Analysis of Ammonia Leak in the Refrigeration Manufacturing Facilities (냉동제조 시설의 암모니아 누출사고 위험 분석)

  • Kang, Su-Jin;Lee, Ik-Mo;Moon, Jin-Young;Chon, Young-Woo
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.1
    • /
    • pp.43-51
    • /
    • 2017
  • Recently, ammonia leak occurred frequently in the domestic refrigeration manufacturing facilities. Ammonia caused great damage to the environment and human health in the event of an accident as combustible gases and toxic gases. After considering the types of ammonia accidents of domestic refrigeration manufacturing facilities and selected accident scenarios and to analyze the risk analysis through Impact range estimates and frequency analysis and there was a need to establish measures to minimize accident damage. In this study, depending on the method of analysis quantitative risk assessment we analyzed the risk of the receiver tank of ammonia system. Scenario analysis conditions were set according to the 'Technical guidelines for the selection of accident scenario' under the chemicals control act and 'Guidelines for chemical process quantitative risk analysis' of center for chemical process safety. The risk estimates were utilized for consequence analysis and frequency analysis by SAFETI program of DNV, event tree analysis methodology and part count methodology. The individual risk of ammonia system was derived as 7.71E-04 / yr, social risk were derived as 1.17E-03 / yr. The derived risk was confirmed to apply as low as reasonably practicable of the national fire protection association and through risk calculation, it can be used as a way to minimize accidents ammonia leakage accident damage.