• Title/Summary/Keyword: 화재대피

Search Result 313, Processing Time 0.023 seconds

Simulation of Fire Evacuation Induction System Using Smartphone Navigation Application

  • Shin, Dongmin;Jeon, Seongman;Lee, SungPil;Cho, Byungjun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.12
    • /
    • pp.243-251
    • /
    • 2020
  • This study is intended to verify the efficiency of the information system by using the navigation application in case of fire. In the demonstration scenario simulation, it was assumed that a fire occurred 6th floor in Korea Institute of Industrial Design Promotion located in C city, K province. Eighty juniors students from K University's department of paramedics of science participated. As a result of the experiment, the demonstration simulation using the navigation application showed that the evacuation time was faster than the case of evacuation guidance in a fire situation. The need for a fire prevention system and fire prevention awareness before and after the implementation of the demonstration scenario simulation increased the need for a fire prevention system and fire prevention awareness score after the experiment.

A Study on Fire and Evacuation simulation analysis for use of Disaster Vulnerable Personal Evacuation Device (재난약자 대피 도움장치 활용을 위한 화재 피난 시뮬레이션 분석 연구)

  • Choi, Doo Chan;Hwang, Hyun Soo;Ko, Min Hyeok;Lee, Si Yu
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.4
    • /
    • pp.824-831
    • /
    • 2020
  • Purpose: In fire case, nursing hospitals are subject to considerable restrictions on evacuation due to the characteristics of occupants and vulnerable elements of buildings, it is important to make evacuation device for vulunerabale person, and need how to intend to increase the efficiency of evacuation by fire and evacuation simulation with helper Method: The smoke characteristics were analyzed by time through fire simulation, finally, the number of helpers according to the day and night was entered, and the evacuation completion time was compared and analyzed using the evacuation simulation. Result: It was found that the evacuation time was shortened by more than 20% when the evacuation assistance device was used for the vulnerable, and the evacuation time was delayed by almost 70% in case of a fire at night compared to the daytime. Conclusion: If the horizontal and vertical evacuation device are effectively utilized in actual fire situations, a strategy appropriate to the situation is deemed necessary. It is expected that evacuation efficiency will increase based on the use of horizontal evacuation evacuation device and vertical evacuation device by developing evacuation manuals

Effects of computer and demonstration scenario simulation using smart fire evacuation guidance on evacuation induction and time (스마트 화재대피 유도 컴퓨터 및 실증 시나리오 시뮬레이션이 피난 유도와 시간에 미치는 영향)

  • Shin, Dong-Min;Cho, Byung-Jun
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.12
    • /
    • pp.244-253
    • /
    • 2021
  • This study examined how the fire evacuation induction service system using a smartphone navigation application in the event of a fire affects the fire evacuation time, and the following conclusions were drawn. 1. The evacuation time was reduced by 22 seconds when the navigation application was used in computer scenario simulation. Even in the demonstration simulation, the evacuation time was reduced by 40 seconds when the navigation application was used. This indicates that the navigation application is effective in shortening the evacuation time in case of fire. 2. As a result of the demonstration scenario simulation, the time until the end of evacuation was 39 seconds faster in the case of evacuation guidance than in the case where it was not conducted. 3. No bottlenecks occurred in the evacuation route during the demonstration scenario simulation. As a result, there was a difference in the time required to complete the evacuation between the computer scenario simulation and the demonstration scenario simulation.

방화문 열전달에 의한 대피공간 내부의 온도영향성 연구

  • An, Chan-Sol;Yeo, In-Hwan;An, Jae-Hong;Jo, Gyeong-Suk
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.172-173
    • /
    • 2013
  • 발코니 확장에 따른 아파트의 화재안전기준 강화를 목적으로 건축법 시행령 제 46조 제 4항의 규정에 따라 현재 건축되고 아파트에는 $2m^2$이상의 대피공간을 설치해야 한다. 그리고 대피공간은 채광방향과 관계없이 거실 각 부분에서 접근이 용이한 장소에 설치해야 하며, 출입구에 설치되는 갑종방화문은 거실쪽에서만 열 수 있는 구조로 해야한다. 하지만 현재 시공되고 있는 방화문은 비차열성 방화문으로써 거실공간에서 화재가 발생하였을 경우 방화문의 열전달 현상에 의해 대피공간 내부의 온도상승이 유발되지만 현재 방화문의 차열성능에 대한 규정이 부재하기 때문에 향후 인명피해가 우려되는 상황이다. 본 연구에서는 실제 방화문의 성능시험을 통해 대피공간과 접한 방화문 면의 온도변화를 측정하였으며, 이로 인한 대피공간 내부의 온도변화를 분석하기 위해 수치해석을 수행하였다.

  • PDF

Development of a Server-independent System to Identify and Communicate Fire Information and Location Tracking of Evacuees (화재정보 확인과 대피자 위치추적을 위한 서버 독립형 시스템 개발)

  • Lee, Chijoo;Lee, Taekwan
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.6
    • /
    • pp.677-687
    • /
    • 2021
  • If a fire breaks out in a building, occupants can evacuate more rapidly if they are able to identify the location of the fire, the exits, and themselves. This study derives the requirements of system development, such as distance non-limitation, a non-additional device, a non-centralized server system, and low power for an emergency, to identify information about the fire and the location of evacuees. The objective is to receive and transmit information and reduce the time and effort of the database for location tracking. Accordingly, this study develops a server-independent system that collects information related to a building fire and an evacuee's location and provides information to the evacuee on their mobile device. The system is composed of a transmitting unit to disseminate fire location information and a mobile device application to determine the locations of the fire and the evacuee. The developed system can contribute to reducing the damage to humans because evacuees can identify the location of the fire, exits, and themselves regardless of the impaired server system by fire, the interruption of power source, and the evacuee's location. Furthermore, this study proposes a theoretical basis for reducing the effort required for database construction of the k-nearest neighbor fingerprint.

A Study on the External Evacuation System for Large-scale Fire of Multi-use Facilities (다중밀집시설 대형화재 외부대피 체계에 관한 연구)

  • Kim, Jung-Gon;Jeong, Min-Su;Jung, Jae-Wook
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.1
    • /
    • pp.129-145
    • /
    • 2022
  • Purpose: This study aims at preparing an external evacuation system by setting up situation that may occur outside buildings in case of large-scale fire at buildings such as multiuse facilities and presenting appropriate response procedures and action instructions for evacuees and facility managers. Method: Major matters are summarized based on various situations which may occur outside in case of fire and the contents of fire manual. Necessary factors including risk alert standards in the event of fire and the role of building occupants are classified and then important issues are summarized. In addition, the definition of fire-related outside shelters and external evacuation routes are showed, and then the applicability to the shelters and the routes are reviewed for old apartments in Jung-gu among multi-dense facilities. Result: Four stages (attention, caution, alert, serious) for standards of fire risk warning are established with the results of the investigation and analysis, and guidelines for behavior for evacuees, facility owners, residents, managers are summarized and presented. In addition, the concept and role of external shelters are divided into primary to the third shelters, and matters related to the definition of each shelter and the establishment of evacuation routes are presented, and then considered them carefully. Conclusion: This study has highlighted the importance of suggesting a systematic plan to secure the safety for evacuees outside space of buildings with disorder and difficulty to control in the event of fire. Therefore, we are confident that it will be useful in making an integrated manual for inside and outside buildings.

Application of Evacuation and Fatalities Simulator for Fire Risk Assessment in High-Rise Buildings (초고층 화재 위험성 평가를 위한 대피 및 인명피해 시뮬레이터 검증에 관한 연구)

  • Park, Jun;Yoon, Sung-Wook;Kim, Hyo-Geun;Ha, Hee-Sang;Lee, Sang-Pil
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.377-380
    • /
    • 2012
  • 대피 및 인명피해 시뮬레이션 기술은 성능위주 설계의 핵심 기술 중 하나이다. 기존 해외에서 개발된 프로그램들은 단순한 인명피해 계산 방식과 비주얼의 조악으로 한계성을 나타내고 있다. 본 연구에서 개발된 대피 및 인명피해 평가 프로그램은 기존의 프로그램의 한계점을 극복함과 동시에 다음의 관련 기술을 향상시키고 실제 사례에 적용하여 현재 사용되고 있는 상용 대피 프로그램과 비교/검증하였다. 첫째, 피난계단 뿐만 아니라 엘리베이터를 이용하여 대피할 수 있는 알고리즘을 적용하였다. 둘째, 미국 표준연구소(NIST)의 화재해석 프로그램 (FDS, Fire Dynamics Simulator)과 연계(Coupled)를 통해 화재에 의한 인명피해 발생여부 판단이 가능한 프로그램이다. 마지막으로 그래픽 전용 모듈을 적용하여 현실에 가까운 3차원 가상현실을 구현하였다.

  • PDF

A study on the Application of Optimal Evacuation Route through Evacuation Simulation System in Case of Fire (화재발생 시 대피시뮬레이션 시스템을 통한 최적대피경로 적용에 관한 연구)

  • Kim, Daeill;Jeong, Juahn;Park, Sungchan;Go, Jooyeon;Yeom, Chunho
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.1
    • /
    • pp.96-110
    • /
    • 2020
  • Recently, due to global warming, it is easily exposed to various disasters such as fire, flood, and earthquake. In particular, large-scale disasters have continuously been occurring in crowded areas such as traditional markets, facilities for the elderly and children, and public facilities where various people stay. Purpose: This study aims to detect a fire occurred in crowded facilities early in the event to analyze and provide an optimal evacuation route using big data and advanced technology. Method: The researchers propose a new algorithm through context-aware 3D object model technology and A* algorithm optimization and propose a scenario-based optimal evacuation route selection technique. Result: Using the HPA* E algorithm, the evacuation simulation in the event of a fire was reproduced as a 3D model and the optimal evacuation route and evacuation time were calculated for each scenario. Conclusion: It is expected to reduce fatalities and injuries through the evacuation induction technique that enables evacuation of the building in the shortest path by analyzing in real-time via fire detection sensors that detects the temperature, flame, and smoke.

Implementation of Smart Fire Safety System (스마트 화재 안전 시스템의 구현)

  • Duk-Kyu Choi;Yun-Ho Kang;Min-Sung Jang;Ju-An Son;Hee-Jun Seo;Hyeon-Gyu Lee;Jin-Ho Kim
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2023.01a
    • /
    • pp.279-280
    • /
    • 2023
  • 소방청 국정감사에서 2020년 전국 자동화재속보설비 화재신고 32,764건 가운데 32,685건이 오작동으로 출동해 소방서 출동의 99.8%가 헛걸음이었다. 그리고 화재가 발생할 경우 화재경보장치와 대피경로를 안내하는 비상등이 미흡하고, 화재 연기가 제거되지 않아 대피가 힘들어질 뿐만 아니라 미처 대피 못한 인원을 파악하는 등의 신속한 대처가 힘들다. 본 논문은 화재 상황에서 피해를 최소화하기 위한 '스마트 화재 안전 시스템' 기술을 제안한다. 화재가 발생할 경우, 대피 경로를 안내하는 유도등 작동 및 경보음과 LED의 작동으로 화재발생을 경고하여 신속한 대처를 할 수 있게 도와주고, 문과 창문의 자동 개방 및 환기팬 작동으로 인한 유해가스를 환기시켜 준다. 그리고 스프링클러 작동과 소화제를 자동 분사하여 화재의 번짐 등 2차 피해를 예방하여 준다. 또한, 자동 신고 기능으로 더욱 빠르게 화재를 진압할 수 있게 도와주기 때문에 피해를 최소화할 것이다.

  • PDF

Integrated Fire Safety System (통합 화재 안전 시스템)

  • Jang, Eun-Gyeon;Lee, Dong-Min;Yoon, Ho-Yeol;Kim, Jun-Hyuck
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2020.01a
    • /
    • pp.127-128
    • /
    • 2020
  • 본 논문에서는 무선 통신(Wi-Fi)과 FireBase를 활용해 화재 발생을 알려 다수의 사람들이 대피 할 수 있는 시스템이다. 이 시스템은 아두이노를 기반으로 가스·불꽃·온도센서로 화재를 감지하고, 화재를 감지하면 무선 통신을 이용해 서버와 파이어 베이스로 전송한다. 서버로 전송된 데이터는 사용자들에게 어플리케이션의 푸시 기능으로 화재 발생 알림을 전송하고, 파이어 베이스로 전송된 데이터는 어플리케이션에서 대피경로를 알려주어 신속한 대피를 할 수 있게 한다.

  • PDF