• Title/Summary/Keyword: 화재대응

Search Result 474, Processing Time 0.029 seconds

A Study of Smart Robot Architecture and Movement for Observation of Dangerous Region (위험지역 감시스마트로봇의 설계와 동작에 관한 연구)

  • Koo, Kyung-Wan;Baek, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.83-88
    • /
    • 2013
  • Catastrophic disasters are sprouting out recently, i.e., the radiation leaks and the hydrofluoric acid gas leaks, etc. The restoration work for these kinds of disasters is very harmful and dangerous for human beings to handle themselves, thus allowing manless robots to fly the reconnaissance planes over to the disaster stricken areas and do the necessary work instead. For this endeavor and purpose, we created and tested an intelligent robot that can inspect those areas, using Mbed (ARM processor) technology temperature sensors and gas sensors aided by CAM (Computer-Aided Manufacturing) cameras. Also, HTTP Server, PC, androids and their combined efforts allow their remote controlled operation from far away with timing control. These intelligent robots can be on duty for 24 hours, minimizing the accidents and crimes and what not, and can respond more quickly when these misfortunes actually happen. We can anticipate the economic effects as well, derived from the reduced needs for hiring human resources.

Vulnerability Analysis on Fire Service Zone using Map Overlay Method in GIS (GIS 기반 중첩기법을 이용한 소방서비스 취약지역 분석)

  • Lee, Seul-Ji;Lee, Ji-Yeong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.1
    • /
    • pp.91-100
    • /
    • 2011
  • Fire stations should be located in optimal location to act quickly in case of emergency and minimize damages as a public facility that protects life and property of local residents. Siting fire stations without regard for the accessibility and occurrence factors of an accident may provide fire service unequally. Therefore service analysis is necessary to reduce the blind spot of disaster and safety and to offer equal fire-service at this time. Especially fire stations can service more efficiently than before by reducing a more likely vulnerable area. This study suggests methods of mapping index of value that represents vulnerability of the occurrence of an accident and extracting service zone map of fire stations, as an initial research for offering efficient fire service. Geographical distribution mismatch between service zone map and vulnerability map is figured out and vulnerable area for fire service is defined by using map overlay method.

The Risk and Countermeasures of Asbestos Exposure at the Scene Activities of Fire Officials (소방공무원들의 현장 활동 시 석면노출의 위험성과 대응방안)

  • Lee, Jung-Il
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.68-78
    • /
    • 2010
  • The purpose of this study, fire officials during the field activities find causes fugitive dust of containing asbestos is the seriousness of the phenomenon is a threat case and through questionnaires, during on-site activities to prevent exposure to asbestos is effectively. Analysis of the relationship to field activities of fire officials and about the dangers of asbestos dust, asbestos cancer caused by asbestos, and to protect fire officials from the same disease like malignant mesothelioma, by varying the conditions of irrational, fire officials at the scene activities in advance of a deadly hazard is aimed to eliminate through optimization of organizational management and a safe and pleasant working conditions for fire officials through the deadly hazards at the scene of action is aimed to obviate. Also according to asbestos exposure by wearing protective equipment as well as thoroughly strengthen firefighting, firefighting awards to recognize the seriousness of the hazard factors, disease and provide compensation to the legal system, for diseases not yet recognized officially recognized by disaster supplemented by institutional, fire officials to improve morale and working conditions, etc. versus expectations is to improve public services.

Statistical Analysis of Chemical Substance Transporting Accidents (화학물질 운송 화학사고의 통계 특성 분석에 관한 연구)

  • Lee, Tae-Hyung;Lee, Sang-Jae;Shin, Chang-Hyun
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.23-30
    • /
    • 2016
  • This study analyzed the characteristics of chemical accidents, including the accidents occurring each year according to status, type of accident, accident cause for chemical substance transporting accidents. The major aim of this study was to provide information on the chemical accidents that occurred involving chemical substance transporting accidents from 2013 to July - 2016. The total incidence of chemical transporting accidents was 77 cases; 74 cases occurred by the spill & leakage type. The main cause of the accidents analyzed was traffic accidents (41 cases). Forty-six accidents were related to hazardous chemical substances. Among the 46 hazardous chemical substances involved in transporting chemical accidents, 46% of the accident substances were hydrogen chloride. For the prevention and response to accidents occurring during the transportation of chemicals, it is necessary to complement the precautions for chemical accidents caused by transportation accidents and chemical spills and leaks of chemicals. In addition, when the chemical transport of an accident occurs, it is necessary to apply a chemical transport safety system for chemical transfer.

The Seismic Design of Water Extinguishing Piping Systems for Equivalent Static Analysis Method (등가정적해석법에 의한 수계 파이프 시스템의 내진설계)

  • Lee, Dong-Myung
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.100-105
    • /
    • 2012
  • In this study, seismic design in pipeline of pressurized water supply system of water extinguishing system has been carried out. This study described a generation of artificial earthquake wave compatible with seismic design spectrum, and also determined equivalent static loads to analyzed the response spectra acceleration by the simulated earthquake motion. This study constructed powerful engineering base for seismic design, and presented equivalent static analysis method for seismic design of water and gas extinguishing piping system. Also, this study readied basis that can apply seismic design and performance estimation of fire fighting system as well as pipeline of water extinguishing system from result of this research. Hereafter, if additional research by earthquake magnitude and ground kind is approached, reliance elevation, safety raising and performance based design of fire fighting system see to achieve.

A Study on the Operation and Function Improvement for apparel warehouse Using Fuzzy-AHP (Fuzzy-AHP를 활용한 의류 물류창고 운영개선에 관한 연구)

  • Kwon, Sung-Joon;Cha, Young-Doo;Yeo, Gi-Tae
    • Journal of Digital Convergence
    • /
    • v.15 no.9
    • /
    • pp.23-33
    • /
    • 2017
  • Given the expansion of globalization and international trade, the number of apparel consumers is growing every year, making it difficult to estimate the amount of handling needed from the logistics industry. To determine which management factors are important and which ones require improvement, fuzzy AHP was used. Using this method, the factors were ranked in the final analysis as follows: The first and most important factor was training employees (0.17), while the second was fire hazard management (0.169); the third-highest factor was inbound and outbound goods (0.142), and the fourth was the warehouse management system. Barcode management was ranked fifth. By these results, we were able to analyze the processes of clothing warehouses, noting that although the factors appear independent, they are actually connected while proceeding with full management control. Moreover, because of the special characteristics of garments, employee management is crucial. Due to the vulnerability of these goods to fire hazards, this factor must be well managed.

A Study on the Development of the Curriculum for EMT Continuing Education (응급구조사 보수교육의 교과과정 개발에 관한 연구)

  • 최용철;이창섭;왕순주
    • Fire Science and Engineering
    • /
    • v.17 no.1
    • /
    • pp.46-61
    • /
    • 2003
  • As EMTs (Emergency Medical Technician), they will be required to attend a certain number of hours of continuing education each year to maintain, update, and expand their knowledge and skills. Continuing Education courses must be designed to keep up with the rapid changes in medicine. But, there are no standard CE curricula including reasonable subject matters and contents in this country, This paper analyzed many different CE curricula in advanced countries and examined the survey for educational needs to develop a standard CE curriculum. The following alternative plans to improve was proposed : (a) The subject matters should be enlarged and the contents subdivided. (b) The reasonable school hours of each subject matter should be allocated. (c) The applicable curriculum to the field affairs should be designed. (d) The frequency of CE should increased to expand an educational chance. (e) The educational circumstances should be improved, the educational outcomes be evaluated and flowed back. On the basis of the above alternatives plans, this paper proposed a model for the standard CE curriculum.

R&D Capability Analysis of Domestic Fire-fighting Safety and Rescue Research Program (국내 소방안전 및 구조구급 R&D 역량 분석)

  • Jeong, Jae-Han;Na, Yong-Woon;Han, Yong-Taek
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.130-136
    • /
    • 2016
  • In this study, the budget investment state of the technology classification structure in a fire-fighting and safety research development program and the capability of a fire-fighting safety research program were analyzed between 2007 and 2013 with support from the ministry of public safety. The Ministry of public safety and security's fire safety research funding has shown a gradual increasing tendency. More 80% of the budget was invested in fire safety and disaster response technologies and the fire safety and special disaster prevention response technology of R&D. From the results of analyzing the capacity of fire-fighting safety and rescue safety, it was found to have a moderate level of 3.5 on a 7 point scale basis. To develop the Ministry of Public Safety and Security's fire safety research in the future, the flexibility and reasonableness of the budget/legal/institutional framework and support should be ensured to improve the operational capability of resources. In addition, a proliferation program is necessary for the commercialization and industrialization of research results.

A Comparison Study on Fire Water Supply Duration and Capacity of Water Based Fire Suppression System of the United States, Japan, China and Korea (우리나라, 중국, 일본, 미국 수계소화설비 소화수 공급시간 및 소화수원에 대한 비교 연구)

  • Min, Se-Hong;Nam, Yu-Hyun
    • Fire Science and Engineering
    • /
    • v.27 no.4
    • /
    • pp.13-20
    • /
    • 2013
  • Buildings in Korea have been getting higher recently and been being changed environmentally since the Korean fire standard was released in 1968. It should be established to make a appropriate correspondence of fire fighting against the those environmental changes. Most of all, fire water capacity which is basis of fire fighting service is a very significant factor. In this paper, the Korean fire water capacity and fire water duration were compared with China, Japan and the United states. Furthermore, fire water capacity, fire water duration, flow rate were compared by hazard classification, occupant use, number of floor and area with water based fire suppression system. This study has been surveyed to show what are difference, similarity, advantage and disadvantage on fire water capacity in the Korean standard comparing with neighboring countries like China, Japan as well as the United states. This study could be found what level the Korean fire water capacity is. So it suggests about more developed standard on fire water capacity with the result of analysis and comparison.

Study on the Development and the Effects of a Fire Safety Education Program for the Elderly (노인을 위한 소방안전교육 프로그램 개발 및 효과분석)

  • Kim, Youngdo;Kim, Youngbin
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.123-133
    • /
    • 2018
  • This study analyzed the effects influencing the elderly's knowledge on fire safety and practices of fire safety accident prevention after developing a Fire Safety Education Program for the elderly. The program was developed through verification using some experts and a pilot study after selecting the objective, goals, contents, and teaching & learning methods of the program based on the basic survey and literature review. The effects of the program were verified by conducting some non-equivalent control group pre- and post-tests after dividing the targets into the experimental group (the Fire Safety Education Program for the elderly was implemented) and control group (only printed hand-outs were given) among 48 elderly people no younger than 65 years of age. A paired t-test revealed some statistically significant differences between the scores of the pre- and post-tests of the experimental and control groups. ANCOVA found that the effects of the program were significantly higher than those of the printed hand-outs because the post-test scores of the experimental group were higher than those of the control group.