• Title/Summary/Keyword: 화염 방지 장치

Search Result 24, Processing Time 0.028 seconds

Study of Fire and Explosion Prevention of an Internal Floating Roof Tank (내부 부상형저장탱크(IFRT) 화재·폭발 예방대책에 관한 연구)

  • Koo, Chae-Chil;Choi, Jae-Wook
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.45-49
    • /
    • 2019
  • This study examined the safety of storage tanks by analyzing the causes of fire on outdoor storage tanks. The outdoor storage tank is a fixed device for the long-term storage of dangerous goods and consists of a tank body and accessories; the accessories consist of a vent system, breather valve, flame arrestor, etc. The flame arrestor is a necessary safety measure to prevent fire explosions on outdoor storage tanks. On the other hand, it has been suggested that the installation of a flame arrester is necessary to compare the domestic and international standards. In addition, the flame arrester should be installed in the existing outdoor storage tanks, to complement foreign standards because there are not enough domestic standards to verify the performance of the flame arrester.

Development of Automatic Making System of a Frame Element for Flame Prevention (화염방지장치용 프레임 엘리멘트의 자동제작장치의 개발)

  • Kim, Gab-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.12 s.189
    • /
    • pp.56-63
    • /
    • 2006
  • This paper describes the development of automatic making system of a frame element for flame prevention. The frame element is made by turning a thin plate and a formed plate on the small pipe. The couple plate(two plates) should be pulled with constant farce to manufacture a good frame element. This is because if the gap between one couple plate and other couple plate is different, it will not prevent flame. In this paper, the automatic making system of a frame element for flame prevention was made, and which could automatically manufacture a frame element. The characteristic test of the made frame element by that system was performed, and its result was very good.

Test Results of Composite Cylinder Surface Temperature change between Pool Fire and Single Impinging Jet Flame Exposure Condition (전체 화염 및 단일 화염 노출 조건에서 복합재료 용기 표면 온도 변화 비교)

  • Lee, Jae-Hun;Hwang, Jun-Ho;Kim, Young-Seop;Kim, Hyo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.648-651
    • /
    • 2009
  • 탄소섬유강화플라스틱(CFRP:Carbon Fiber Reinforced Plastic)용기의 외부에 화재가 발생할 경우 함침된 수지(Resin)가 탄화되면서 자체 강도가 약화되고 충전된 가스가 외부 온도 상승에 따라 압력 상승이 발생하여 용기의 폭발로 이어지는 사고가 발생할 개연성이 높다. 화염 노출조건에서 복합재료 용기의 폭발을 방지하기 위하여 용기용 밸브에 내장된 온도감응식 압력안전장치(TPRD:Thermally activated Pressure Relief Device) 작동 성능을 검증하기 위한 방법으로 화염실험(Bonfire test)를 실시하고 있으나, 개방 공간에서 실시되는 이 실험은 표면 온도 변화가 매우 크게 발생하여 실험에 대한 재현성(Reproducibility)에 의문이 제기되고 있다. 따라서, 표면 온도를 일정하게 유지하기 위한 실험 방법의 개선이 필요하다. 본 연구에서는 경유+heptane을 이용한 전체 화염에 노출되는 경우와, 천연가스를 이용한 단일화염에 노출되는 경우의 실험 결과 비교를 통하여 화염 노출 표면 온도를 일정하게 유지하기 위한 가열 방법의 타당성을 검토하였다. 또한, 복합재료 라이너(Liner)의 온도 변화 비교를 통하여 집중화염 노출 조건에서 열전달 특성을 알아보았다.

  • PDF

Characteristics of Jet Type Flame Holder for Ramjet Engine Combustors (램제트 엔진 연소기용 제트분사형 화염안정기의 특성분석)

  • Kang, Sang-Hun;Yang, Soo-Seok
    • Aerospace Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.14-20
    • /
    • 2007
  • In this study, characteristics of jet type flame holder for ramjet engine combustors are investigated Jet flame holder can be easily controlled by the injection angle change and jet momentum variation without any thermal protection devices. Due to the intensive turbulent mixing effect, jet flame holder shows better flame holding performance than mechanical flame holders such as cavity, step and v-shape flame holder.

  • PDF

Estimating Width of Firebreak through Experiment Method on Surface Fire (실험분석을 통한 지표화 방화선 구축 폭 평가)

  • Kim, Dong-Hyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.140-143
    • /
    • 2011
  • 산불의 확산형태 중 지표화 확산을 방지하기 위해 대표적인 진화방법으로는 방화선을 구축하는 것이다. 지표화는 산림의 연료중 낙엽층, 잔가지 등 지표면의 연료층이 열분해되면서 확산되기 때문에 방화선 구축을 통해 연료층을 제거하면 지표화 확산을 저지할 수 있다. 하지만 방화선 구축 폭에 따라 산불확산 방지 효과가 크게 달라질 수 있으므로 적정한 방화선 구축 폭을 설정하여야 한다. 본 연구에서는 적정 방화선 구축 폭을 살펴보기 위해 풍동시험장치를 이용하여 풍속 0, 1, 2, 3m/s조건에서 지표화 화염으로부터 이격 거리에 따른 온도측정과 함께 방화선 구축 폭에 따른 확산가능 여부를 평가하였다. 50cm 폭의 소나무 낙엽에 대한 풍속별 지표화 방화선 구축 실험결과, 풍속 3m/s에서 화염으로부터 소나무 낙엽의 착화온도인 $311^{\circ}C$에 도달하는 거리가 약 0.65m로 나타났고 풍속이 낮을수록 착화온도 도달거리가 줄어드는 것을 알 수 있다. 실제 0.6m 방화선 구축의 경우, 화염이 계속 확산되었고 0.65m 이상의 방화선 구축시에는 화염확산이 이루어지지 않았다. 따라서 향후, 수치해석을 이용한 열유속 평가 결과와 함께 본 연구의 실험결과와 비교평가 함으로써 지표화 산불확산 방지를 위한 적정 방화선 구축 폭 산정을 평가하고자 한다.

  • PDF

A Study on the Fire Suppression Characteristics of a Flame Arrester with Water Mist System (미분무 시스템이 장착된 화염방지장치의 화재 진화 특성에 관한 연구)

  • Kim, Hae-Ji;Lee, Kyung-Ro
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.5
    • /
    • pp.117-124
    • /
    • 2016
  • In this paper, we developed a breather valve with a water mist system for use near an oil storage tank. Our process applied a water mist system to the flame arrester to evaluate the fire suppression characteristics. For the fire suppression evaluation of the water mist system, we evaluated the angle of the nozzle, fire suppression, spray particle size, flashback, fire suppression time, and fire suppression test of antifreeze. Through the fire suppression test, the best fire suppression nozzle used an angle of $140^{\circ}$, and the flashback phenomenon of flame arrester did not occur. The fire suppression time of water mist system time was within three seconds, and the antifreeze was no problem with the fire suppression.

우주발사체에 적용되는 지상 엄브리칼 체결장치의 구성과 기능

  • Kim, Yong-Uk;Kim, Dae-Rae;Lee, Jeong-Ho;O, Seung-Hyeop
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.151.1-151.1
    • /
    • 2012
  • 우주발사체와 발사지원설비를 연결하여 추진제 공급과 전기신호 송수신 등을 가능하게 하는 메커니즘을 엄브리칼 장치라고 한다. 국내 우주발사체의 경우 액체산소와 케로신을 추진제로 사용하며, 질소, 공기 및 헬륨 등의 가스를 밸브구동, 공간 퍼지, 추진제 가압에 이용한다. 본 논문에서는 우주센터의 발사대설비에 적용된 엄브리칼 장치 중 추진제 및 고압가스 공급을 위한 자동체결장치(auto coupling device)의 구성, 기능 및 발사 준비를 위한 프로세스에 대해 기술하고 있다. 자동체결장치는 발사체 하부 두 곳에 연결되며, 산화제 공급측의 체결장치(coupling device 1)와 연료 공급측의 체결장치(CD 2)로 구성된다. 이 장치는 발사체와의 접촉면에서 기밀을 확보한 상태에서 내부의 탱크, 밸브, 인터스테이지 등에 추진제 및 각종 가스를 공급하는 통로역할을 하며, 발사준비가 완료된 후에는 발사체 이륙 전 또는 이륙과 동시에 발사체로부터 자동으로 분리된다. 각각의 체결장치 구성품으로는 발사체 이륙시 발생하는 고온의 화염으로부터 장치를 보호하는 PD(protective device), 접촉면에 기밀을 제공하고 추진제 누출을 방지는 MCP(multi-channel plate), 접촉면을 보호하기 위한 덮게, 각종 연결 배관의 전진과 후진을 위한 캐리지, 발사체와의 체결을 지지하는 그립 등이 있다. 발사 준비를 위해서 사전에 장치의 독립운용시험을 통해 각 구성품의 상태와 기능을 점검하고 장치의 작동성을 검증한다. 이후 발사체를 모사하는 기체 및 관제설비와 종합적으로 연계 시험과 모사시험을 수행하여 최종적으로 발사준비상태를 확인하게 된다. 이러한 자동체결장치의 운용 경험은 한국형발사체의 지상지원설비 개발에 활용할 수 있을 것이다.

  • PDF

A Study on the Safety Improvement in Incineration System from the Case Study of Acrylic acid manufacturing process Accident (아크릴산 제조공정 사고사례를 통한 소각 시스템의 안전성 향상 방안)

  • Ma, Byung-Chol;Lee, Keun-Won;Im, Ji-Pyo;Kim, Young-Chul
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.4
    • /
    • pp.52-58
    • /
    • 2012
  • Recently, waste gas incineration is increasing due to strong environmental regulatory system in Korea. These incinerating facilities are usually connected with the top of the storage tank through pipeline and incinerate off gas with the flame. Therefore, the flame originated from these facilities is likely to move back into pipeline and might cause an explosion of the storage tank. Accordingly, the purpose of this study is to suggest the preventive measures and the way to improve the safety of these incineration systems through the cause analysis of a major industrial accident occurred in a acrylic acid manufacturing process in Korea. As a result of the study, the preventive measures are suggested as follows. (1) Air or inert gas inflow facilities should be well designed to dilute flammable gases into air or inert gas sufficiently before the blower is restarted in order to prevent the explosion (2) It is needed for the detonation-type flame arresters to be installed on the top of the storage tanks. (3) In case of using the deflagration-type flame arresters, it is necessary to install a rupture disk before the arresters, or blow off the flame outside tanks by connecting the tank top and the incinerator with hood-type pipe. (4) TDR should be installed to be restarted automatically after the momentary power failure.

Development of Cable Tunnel Monitoring System (통신구 원격감시 시 스템 개발 및 시범운용)

  • Park, Jung-Kwon;Han, Jin-Woo;Park, Jong-Ho
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.306-309
    • /
    • 2007
  • 지하구에는 국 가의 신경이라 할 수 있 는 전력, 통신, 상수도 등 주요시설물들이 수용되어 있으며, 지 하구는 화재, 집중호우에 의한 침수, 외부침입 등의 재난에 항상노출되어 있다. 2006년 12월에 발생된 구리 전력구 화재와 2000년 여의도 공동구 화재 등에서 보듯이 화재가 발생하면 화염과 연기, 유독가스로 인해 내부로 진입할 수 없으므로 조기경보 및 조기 대처가 매우 중요하다. 따라서 본 논문에서는 지하구 중에서 통신케이블을 수용하는 통신구의 재난에 조기 대처할 수 있는 통신구 원격감시 시스템에 대해 기술하고자 한다. 통신구 원격감시 시스템은 통신구내의 침입, 침수, 화재 등을 모니터링하여 재난을 미연에 방지할 수 있도록 하고, 각 감지기 및 장치에 설정된 임계치를 초과한 경우 경보 현황을 운용자에게 알려 신속하게 조치할 수 있도록 하였으며, 시스템의 안정성과 확장성, 유지보수의 용이성 등을 고려하여 통합/분산 서버, 데이터 수집장치, 감지기 등 으로 구성 하였고, 시스템간의 연동과 호환성을 위해 표준화된 통신 프로토콜을 사용하였으며, 필요에 따라 감지기 및 장치를 수정, 추가할 수 있도록 개발하였다. 그리고 이를 검증하기 위해 부산지역의 지하철병행통신구 3.8km에 대해 시범설치하여 운용함으로써 시스템의 안정성, 운용성 등에 대해 검증하였다.

  • PDF

Properties Analysis of Thermal Electronic Type MCCB that become Burnout by a Burning Experiment (연소 실험에 의해 소손된 열동전자식 MCCB의 특성 해석)

  • Lee, Jae-Hyuk;Choi, Chung-Seog
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.58-59
    • /
    • 2013
  • 전기설비의 사고 예방 및 확산을 방지하기 위해 설치하는 MCCB의 소손 특성을 해석하였다. MCCB의 작동 상태는 작동기구부의 금속 핀의 위치로 판정이 가능하다. 일반적으로 전기적인 신호가 있을 때 금속 핀이 작동하는 것으로 알려져 있으나 일반 화염에 의해서도 MCCB 작동기구부의 금속 작동 핀이 작동하는 것이 확인되었다. 따라서 MCCB의 트립 장치가 작동되었다는 이유만으로 과전류 또는 단락 등이 발생했다고 단정하는 것은 화재조사의 오류가 있을 수 있으므로 화재 발생 당시의 전체 상황을 고려하여 판단하는 것이 오판을 예방할 수 있다.

  • PDF