• Title/Summary/Keyword: 화염

Search Result 2,499, Processing Time 0.031 seconds

Development of Safe Stove System using Sound Wave Fire Extinguisher (음파 소화기를 이용한 안전 스토브 시스템 개발)

  • Seo, Yunwon;Lee, Sukjae;Park, yungjoo;Kim, Kinam;Choi, Yongrae;Hwang, Hyungjun;Han, Seunghan;Shim, Dongha
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.34-39
    • /
    • 2018
  • In this paper, the architecture of a safe stove with an automatic fire suppression function using a sound wave fire extinguisher has been proposed and developed for the first time. A microcontroller connected to a fire sensor detects and suppresses a fire by driving a fire extinguisher. The sound wave fire extinguisher is composed of a speaker and collimator, and is driven by a driver module including an audio amplifier. The attenuation of the sound wave is reduced by preventing the sound diffusion with an enclosure surrounding a stove. The frequency of the sound wave is set to 50 Hz, and the sound pressure of 93 dBA is measured at the distance of 0.5 m. It takes maximum 8 and 15 seconds to suppress the flame from 7-cc and 14-cc flammable liquid, respectively, which corresponds to 24% and 42% of the natural extinguishing time. Since the proposed safe stove is non-toxic and leaves no residues over the conventional ones, it would combine with various home appliances to suppress early-stage fires and prevent fire expansion.

Study on the Shortening Effect of the Egress Travel Time Based on an Escape Scenarios by Using Shuttle Elevators for Lotte Tall Building's Evacuation Plan (초고층건물 피난계획시 피난용 엘리베이터 이용에 의한 피난소요시간의 단축효과 연구)

  • Park, Hyung-Joo;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.46-54
    • /
    • 2018
  • A total of 19 elevators for evacuation were installed in the Lotte World Tower and it is planned to operate the shuttle using the manual key from five refuge floors to the 1st floor in an emergency. In the event of a fire or other disaster, it is necessary to conduct intensive analysis to determine how much RSET reduction could be achieved using the evacuation elevator compared to the existing evacuation plans. When the optimal transportation sharing ratio by the evacuation elevators was 40% at the Lotte World Tower, the RSET of the evacuation scenario in parallel with the elevators in the entire building was calculated to be 1 hour and 2 minutes. The RSET of a conventional evacuation scenario (Walking along the stairs without using the elevators) was calculated to be 1 hour 29 minutes, therefore, the former evacuation scenario were found to have a shortening effect of approximately 27 minutes compared to the latter. On the other hand, to maintain this effect, each part of the evacuation route using the elevator must have the capability to protect the evacuee from any hazards caused by fires, such as smoke, flame, and radiant heat during the evacuation. Moreover, the evacuation route should be continuous from the residence position of the elevator user to the final evacuation site, and be recognized easily.

Wear Property of HVOF WC-CoCr Coating Manufactured by Optimal Coating Process (최적 고속화염용사코팅 공정기술에 의하여 제조된 WC-CoCr 코팅의 마모 특성)

  • Song, Ki O;Cho, Tong Yul;Yoon, Jae Hong;Fang, W.;Youn, Seok Jo;Youn, Kuk Tae;Suh, Chang Hee;Hwang, Soon Young;Ha, Sung Sik
    • Korean Journal of Metals and Materials
    • /
    • v.46 no.6
    • /
    • pp.351-356
    • /
    • 2008
  • Thermally sprayed tungsten carbide-based powder coatings are being widely used for a variety of wear resistance applications. The coating deposited by high velocity processes such as high velocity oxy-fuel (HVOF) thermal spraying is known to provide improved wear resistant property. In this study, optimal coating process (OCP) is obtained by the study of coating properties such as surface hardness, porosity, surface roughness and microstructure of 9 coatings prepared by Taguchi program for 3 levels of four spray parameters. The Friction and wear behaviors of HVOF WC-CoCr coating prepared by OCP, electrolytic hard chrome (EHC) plating and Inconel718 (In718) are investigated by reciprocating sliding wear test at $25^{\circ}C$, $450^{\circ}C$. Friction coefficients (FC) of all of the 3 samples are decreased as increasing sliding surface temperature from $25^{\circ}C$ to $450^{\circ}C$. FC of WC-CoCr decreases as increasing the surface temperature from $0.33{\pm}0.02$ at $25^{\circ}C$ to $0.26{\pm}0.02$ at $450^{\circ}C$, showing the lowest FC among the 3 samples. Wear trace (WT) and wear depth (WD) of WC-CoCr are smaller than those of EHC and In718 both at $25^{\circ}C$ and $450^{\circ}C$. These show that WC-CoCr is highly recommendable for protective coating on In718 and other metal components.

Numerical analysis study on the concentration change at hydrogen gas release in semi-closed space (수치해석을 통한 반밀폐공간 내 수소가스 누출 시 농도변화에 관한 연구)

  • Baek, Doo-San;Kim, Hyo-Gyu;Park, Jin-Yuk;Yoo, Yong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.1
    • /
    • pp.25-36
    • /
    • 2021
  • Hydrogen in hydrogen-electric vehicles has a wide range of combustion and explosion ranges, and is a combustible gas with a very fast flame propagation speed, so it has the risk of leakage, diffusion, ignition, and explosion. The fuel tank has a Thermally active Pressure Relief Device (TPRD) to reduce the risk of explosion and other explosions, and in the event of an accident, hydrogen inside the tank is released outside before an explosion or fire occurs. However, if an accident occurs in a semi-closed space such as an underground parking lot, the flow of air flow is smaller than the open space, which can cause the concentration of hydrogen gas emitted from the TPRD to accumulate above the explosion limit. Therefore, in this study, the leakage rate and concentration of hydrogen over time were analyzed according to the diameter of the nozzle of the TPRD. The diameter of the nozzle was considered to be 1 mm, 2.5 mm and 5 mm, and ccording to the diameter of the nozzle, the concentration of hydrogen in the underground parking lot increases in a faster time with the diameter of the nozzle, and the maximum value is also analyzed to be larger with the diameter of the nozzle. In underground parking lots where air currents are stagnant, hydrogen concentrations above LFL (Lowe Flammability Limit) were analyzed to be distributed around the nozzle, and it was analyzed that they did not exceed UFL (Upper Flammability Limit).

Forest Fire Area Extraction Method Using VIIRS (VIIRS를 활용한 산불 피해 범위 추출 방법 연구)

  • Chae, Hanseong;Ahn, Jaeseong;Choi, Jinmu
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.5_2
    • /
    • pp.669-683
    • /
    • 2022
  • The frequency and damage of forest fires have tended to increase over the past 20 years. In order to effectively respond to forest fires, information on forest fire damage should be well managed. However, information on the extent of forest fire damage is not well managed. This study attempted to present a method that extracting information on the area of forest fire in real time and quasi-real-time using visible infrared imaging radiometer suite (VIIRS) images. VIIRS data observing the Korean Peninsula were obtained and visualized at the time of the East Coast forest fire in March 2022. VIIRS images were classified without supervision using iterative self-organizing data analysis (ISODATA) algorithm. The results were reclassified using the relationship between the burned area and the location of the flame to extract the extent of forest fire. The final results were compared with verification and comparison data. As a result of the comparison, in the case of large forest fires, it was found that classifying and extracting VIIRS images was more accurate than estimating them through forest fire occurrence data. This method can be used to create spatial data for forest fire management. Furthermore, if this research method is automated, it is expected that daily forest fire damage monitoring based on VIIRS will be possible.

Selection of Artificial Sand Suitable for Manufacturing Steel Castings through Evaluation of Various Foundry Sand Properties (각종 주물사의 특성과 주강품 주조에 적합한 인공사 선택)

  • Gwang-Sik Kim;Jae-Hyung Kim;Myeong-Jun Kim;Ji-Tae Kim;Ki-Myoung Kwon;Sung-Gyu Kim
    • Journal of Korea Foundry Society
    • /
    • v.43 no.3
    • /
    • pp.107-136
    • /
    • 2023
  • Natural silica sand was commonly used for sand casting of cast steel products, and chromites sand was used to suppress seizure defects due to the lack of thermal properties of silica sand. However there are disadvantages such as deterioration by repeated use, system sand mixing problem, difficulty separating and removing, increased during mold according to high density and to being waste containing chrome. Recently, industrial waste reduction and atmospheric environment improvement have been highlighted as important tasks in the casting industry. In order to solve the problems that occur when using foundry Sand and to improve the environment of casting factories, various artificial sands that can be applied instead of natural silica sand have been developed and introduced. Artificial sands can be classified into artificial sand manufactured by the electric arc atomization or gas flame atomization, artificial sand manufactured by the spray drying & sintering process, artificial sand manufactured by the sintering & crushing process and exhibit different physical properties depending on the type of raw-minerals and manufacturing method. In this study, comparative evaluation tests were conducted on the physical properties of various foundry sands, mold strength, physical durability, thermal durability, and casting test pieces. When comprehensively considering the actual amount of molding sand used according to density, the mold strength according to the shape of sand, the physical and thermal durability of foundry sand, and the heat resistance characteristics of foundry sand, 'Molten artificial sand A1' or 'Molten artificial sand B' is judged to be the most suitable spherical artificial sand for casting of heavy steel castings.

Efficacy of Commercial Sanitizers for the Inactivation of Listeria monocytogenes on the Processing Equipment for Enoki Mushrooms (팽이버섯 재배 현장에서 Listeria monocytogenes의 성장을 억제하기 위한 살균 처리 기술 개발)

  • Kyung Min Park;Su-Bin Lee;Do-Young Jung;Song-Yi Choi;Injun Hwang;Se-Ri Kim
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.6
    • /
    • pp.508-516
    • /
    • 2023
  • The consumption of enoki mushrooms has been associated with cases of listeriosis produced by Listeria monocytogenes, highlighting the significance of sanitizing food-contact surface, such as the velcro used in welding processing of enoki mushrooms, to ensure microbial safety. We investigated the inhibitory activity of nine chemical disinfectants at regular concentrations against L. monocytogenes isolated from a mushroom farm environment. The bacterial suspension was prepared in phosphate buffered saline and mushroom extract broth and inoculated onto the velcro surface. After inoculation, most disinfectants reduced the initial 8 log CFU/coupon concentration by less than 2 log CFU/coupon during a 5-min treatment. Slightly acidic hypochlorous water showed a reduction of approximately 4 log CFU/coupon when tested for more than 30 min at the maximum allowable concentration of 200 mg/L. Sodium hypochlorite solution showed a reduction of approximately 5 log CFU/coupon when used at 100 mg/L for 60 min. Peracetic acid, at the maximum allowable concentration of 300 mg/L, showed the most effective reduction of 5 log CFU/coupon or more when the surface was treated with 37.5 mg/L for 30 min. These results indicate that peracetic acid can be used as the disinfectant strategy to control cross-contamination of L. monocytogenes on the velcro surface of plastic wrappers used in the welding processing of enoki mushrooms.

The Bacterial Colonization of Burn Wound and the Changes of Antibiotic Susceptibility in Childhood Burn (January, 1999~December, 2002) (소아 화상의 화상부위 세균 집락화와 항균제 감수성 변화(1999년 1월~2002년 12월))

  • Kim, Jin-Man;Lee, So-Yeon;Kim, Young-Ho;Shin, Eon-Woo;Oh, Phil-Soo;Kim, Kwang-Nam;Lee, Kyu-Man;Oh, Suk-Joon
    • Pediatric Infection and Vaccine
    • /
    • v.12 no.2
    • /
    • pp.157-165
    • /
    • 2005
  • Purpose : Children occupy a large proportion of burn victims. So we want to aid to pediatric burn care through the understanding of the bacterial distribution in burn wounds and antibiotic susceptibility against isolated microorganisms from burn wounds. Methods : We analysed the medical records of 213 pediatric burn patients(0~15 years), 406 samples that grew bacteria in burn wound sites. Results : Of the total 213 patients, male were 59.6% and female were 40.4%. Scalding burn was the most common(78.4%), flame burn was the second(16.4%). Pathogens were isolated in 406 samples. The most common was Pseudomonas aeruginosa(58.1%). Next were Enterococcus species, Staphylococcus aureus, Staphylococcus epidermidis, Streptococcus species, Acinetobacter species. P. aeruginosa was resistant to trimethoprim-sulfamethoxazole in 100%, cephalothin in 98.1%, ampicillin-sulbactam in 96.2%, ampicillin in 95.3%, ceftriaxone in 95.2%, tobramycin in 93.7%, cefoperazone in 68.9%, ceftazidime in 67.7%. Enterococcus species were resistant to tetracycline in 63.9%, streptomycin in 45.5%, gentamicin in 36.1%, penicillin G in 13.7%. S. aureus was resistant to gentamicin in 89.7%, tetracycline in 86.2%, ciprofloxacin in 86.2%, penicillin G in 84.3%, oxacillin in 78.4%, erythromycin in 76.5%. Acinetobacter species were resistant to ampicillin-sulbactam in 100%, gentamicin in 85.7%, ampicillin in 83.3%, piperacillin in 61.5%. Conclusion : P. aeruginosa was highly resistant to drugs like cefoperazone in 68.9%, ceftazidime 67.7%. S. aureus was highly resistant to penicillin G in 84.3%, oxacillin in 25.9 %, but none to vancomycin in 0%, teicoplanin in 2.2%. According to the study, Acinetobacter species turned out to be multi-resistant strains, so careful attention must be paid to the choice of antibiotics.

  • PDF

Antimicrobial Effects of Chlorine Dioxide Gas on Pathogenic Escherichia coli and Salmonella spp. Colonizing on Strawberries for Export (수출 딸기 중 이산화염소 가스 처리를 통한 병원성 Escherichia coli와 Salmonella spp. 저감화 효과)

  • Lee, Hyo-Sub;Shim, Won-Bo;An, Hyun Mi;Ha, Ji-Hyoung;Lee, Eun-Seon;Kim, Won-Il;Kim, Hwang-Yong;Kim, Se-Ri
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.6
    • /
    • pp.451-457
    • /
    • 2016
  • The purpose of this study was to determine the antimicrobial effects of $ClO_2$ gas on pathogenic E. coli and Salmonella spp. colonizing on the fruit surface of strawberries for export. Factorial design was employed to treat strawberries inoculated with pathogenic E. coli or Salmonella spp. with a combination of $ClO_2$ gas concentrations (10, 20, 30, 40, and 50 ppmv), RH (50, 70, and 90%), and treatment time (0, 5, 10, 20, and 30 min). Interaction between the factors was observed to note that the reduced levels of microbial population were the highest when RH is set at 90% with gas concentration- and treatment time-dependent manner. With RH and gas concentration fixed at 90% and 50 ppmv, the populations of E. coli and Salmonella spp. decreased by 2.07 and 2.28 log CFU/g when treated for 20 min whereas population reduction by 0.5 and 0.7 log CFU/g were observed when treated for 5 min, respectively. The results help establish most effective conditions for $ClO_2$ gas treatment to enhance microbial safety of strawberries for export.

Herbicidal Properties of 5,8-dihydroxy-1,4-naphthoquinone and Their Possible Mode of Action (천연물 유래 5,8-dihydroxy-1,4-naphthoquinone의 살초특성과 작용기구)

  • Choi, Jung-Sup;Kim, Ji-Yeon;Seo, Bo-Ram;Ko, Young-Kwan;Cha, Mi-Ran;Kim, Young-Sup;Ryu, Shi-Yong;Hwang, In-Taek
    • Korean Journal of Weed Science
    • /
    • v.31 no.3
    • /
    • pp.250-259
    • /
    • 2011
  • This study was conducted to assess the possibility of 5,8-dihydroxy-1,4-naphthoquinone (DHNQ) as a environmental friendly herbicide candidate. Foliar application of DHNQ showed excellent herbicidal effect to the 3 grasses and 5 broad-leaved weeds. Among them, Digitaria sanguinalis and Solanum nigrum were completely controlled by $250{\mu}g\;mL^{-1}$ of DHNQ with main symptoms of desiccation or burndown within 24 hours. Aeschynomene indica was also sensitive to DHNQ treatment. All of the eight weed species were controlled by 90~100% at a concentration of $1000{\mu}g\;mL^{-1}$. However, soil application of DHNQ to Digitaria sanguinalis did not show any herbicidal symptoms. DHNQ strongly inhibited KAPAS activities in vitro and the $IC_{50}$ was $4.4{\mu}M$. Cellular leakage from cucumber leaf squares treated with DHNQ increased depending on the concentrations increased from 6.25 to $100{\mu}M$ after 24 hours incubation with or without light. However, chlorophyll loss in cucumber leaf squares was negligible. Biotin supplements significantly rescued the inhibition of germination rate of Arabidopsis thaliana seeds previously inhibited by the DHNQ. According to above results, DHNQ is a good natural herbicide candidate having a new target KAPAS, which is involved in biotin biosynthesis pathway, with environmental friendly.