• Title/Summary/Keyword: 화염

Search Result 2,499, Processing Time 0.03 seconds

A Study on the Fire Characterization of Foam block using Cone-calorimeter and FTIR (콘칼로리미터와 적외선분광계(FTIR)를 이용한 폼블럭의 연소특성에 대한 실험적 연구)

  • Han, Bong-Hoon;Seo, Dong-Ho;Kwon, Young-Hee;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.23-32
    • /
    • 2017
  • Foam block, popularized as the self-interior goods, is susceptible to fire since the main material is the polyethylene flammable synthetic resin. However, it is widely used in homes, offices, and multi-use facilities. In order to understand the fire characteristics of the foam block, two kinds of foam blocks sold in the market (non-fire retardant and fire retardant) were evaluated according to standard of KS F 5660-1 (Reaction to fire test). In addition, the hazard analysis of the gas generated by the combustion of the specimen was performed using the FTIR gas analyzer. The cone calorimeter test showed that the ignition and flame combustion of both two specimens were burned as soon as the radiant heat blocking device was removed, and it was confirmed that the flame could become a rapid propagation factor during the fire. The analysis of the combustion gas through the FTIR gas analyzer showed that both the carbon dioxide and carbon monoxide classified as the common combustion gases and the acrolein, ammonia, and hydrogen cyanide causing serious damage to the human body were detected substantially. This study showed that a foam block product has high ignitionability and generates toxic gases. Hence, it is urgently required to establish the standards used for properly classifying the combustion characteristics of the material on the basis of the use conditions of a foam block product and to prepare the standards on the purpose of use.

An Experimental Study on Fire Spreading External Wall of Buildings Using Dry Construction Method (건식공법을 이용한 건축물의 외벽 화재 확산의 실험적 연구)

  • Park, Jung-Woo;Cho, Nam-Wook
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.75-85
    • /
    • 2018
  • The Grenpell tower fire in England in June of 2016 is a representative example of damage caused by a vertical fire spreading through external insulation. Organic insulation materials, which are widely used in external insulation, have the disadvantage that they have good insulation performance but are vulnerable to fire. Aluminum composite panels are used as exterior wall finishing materials, and plastics used in aluminum are regarded as the cause of vertical fire spread. Due to the steel frame used to secure the aluminum composite panel to the outer wall, a cavity is formed between the outer wall and outer wall finish. When a fire occurs on the outer wall, the flammable outer wall as well as the flame generated from the heat-insulating material spreads vertically through the cavity, resulting in damage to people and property. In Korea, material unit performance tests are carried out by the Ministry of Land, Infrastructure and Transport notice 2015 - 744. However, in the UK, the BS 8414 test is used to measure the vertical fire spreading time on the outer wall in real scale fire tests. In this study, the risk of external wall fire was evaluated in an actual fire by conducting a real scale wall fire test (BS 8414), which was carried out in Europe, using aluminum composite panels of semi-noncombustible materials suitable for current domestic standards. The purpose of this study was to confirm the limitations of material unit evaluation of finishing materials and to confirm the necessity of introducing a system to prevent the spread of outer wall fire through an actual scale fire test.

Numerical Study of Evaporation and Ignition of in-line Array Liquid Droplets (액적 배열의 증발과 착화에 관한 수치해석적 연구)

  • 김충익;송기훈
    • Fire Science and Engineering
    • /
    • v.13 no.1
    • /
    • pp.37-47
    • /
    • 1999
  • The spreading fire of very small floating particles after they are ignited is fast and t therefore dangerous. The research on this area has been limited to experiments and global simulations which treat them as dusts or gaseous fuel with certain concentration well m mixed with air. This research attempted micro-scale analysis of ignition of those particles modeling them as liquid droplets. For the beginning, the in-line array of fuel droplets is modeled by two-dimensional, unsteady conservation equations for mass, momentum, energy and species transport in the gas phase and an unsteady energy equation in the liquid phase. They are solved numerically in a generalized non-orthogonal coordinate. The single step chemical reaction with reaction rate controlled by Arrhenius’ law is assumed to a assess chemical reaction numerically. The calculated results show the variation of temperature and the concentration profile with time during evaporation and ignition process. Surrounding oxygen starts to mix with evaporating fuel vapor from the droplet. When the ignition condition is met, the exothermic reactions of the premixed gas initiate a and burn intensely. The maximum temperature position gradually approaches the droplet surface and maximum temperature increases rapidly following the ignition. The fuel and oxygen concentration distributions have minimum points near the peak temperature position. Therefore the moment of ignition seems to have a premixed-flame aspect. After this very short transient period minimum points are observed in the oxygen and fuel d distributions and the diffusion flame is established. The distance between droplets is an important parameter. Starting from far-away apart, when the distance between droplets decreases, the ignition-delay time decreases meaning faster ignition. When they are close and after the ignition, the maximum temperature moves away from the center line of the in-line array. It means that the oxygen at the center line is consumed rapidly and further supply is blocked by the flame. The study helped the understanding of the ignition of d droplet array and opened the possibility of further research.

  • PDF

Experimental and Numerical Studies on the Failure of Curtain Wall Double Glazed for Radiation Effect (커튼월 이중 유리 외장재 파단에 대한 실험 및 수치해석 연구)

  • Nam, Jiwoo;Ryou, Hong-Sun;Kim, Dong-Joon;Kim, Sung-Won;Nam, Jun-Seok;Cho, Seongwook
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.40-44
    • /
    • 2015
  • National and international standards for curtain wall glass are focused on wind pressure and insulation performance, but disasters such as fires and earthquakes are not considered. Failure of curtain wall glass during a fire in a skyscraper increases the loss of lives and property due to the spread of fire. Therefore, the fire resistance of curtain wall glass should be investigated, and technology to prevent glass failure should be developed to prevent fire damage due to spreading fire. It is important to predict the starting point of cracks and the cause of glass failure to prevent it effectively using the limited water in a skyscraper. In this study, double glazed glass was exposed to a radiator in an experiment performed to analyze the thermal characteristics. The results show that glass that was not directly exposed to high temperature and pressure was broken. To identify this failure case, numerical analysis was performed. Three glass specimens were installed in an ISO 9705 room and exposed to radiation using a radiator, and a thermocouple was used to measure the temperature on the surface of the glass. Widely used double glazed glass was analyzed for weakness to fire.

A Study on Fire Performance Evaluation of EIFS on Anti-Flaming Finish by Cone Calorimeter Test (콘칼로리미터에 의한 외단열시스템의 방염 화재성능평가를 위한 연구)

  • Min, Se-Hong;Sun, Ju-Seok;Kim, Sang-Chul;Choi, Yong-Mook;Lee, Seok-Ki
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.106-111
    • /
    • 2012
  • In this study, EIFS (Exterior insulation finish system) of exterior cladding was applied Cone calorimeter test to confirm the effect of flame retardant. As a results, the initial ignition points in accordance with the coated form and concentration of the flame retardant was delayed. But flame resistant treatment of EIFS cladding to control the fire will not affect confirmed that. In addition, EIFS that uses high-density and low-density due to difference in the density of the impact of the fire was no difference. The exterior of the ignition experiment occurred before and after 40 seconds, heat release rate to 100 seconds appears to occur about 90 % compared with the other exterior wall materials, the initial fire spread very fast was confirmed. EIFS cladding in order to prevent the spread of fire in the application of EIFS legally use is limited by the use of the building. And flame spread can be prevented, such as a vertical outer wall compartment measures are urgently needed.

Fire and explosion risk of metal particles with the same mean diameter (동일 입경 조건에서의 금속분진의 화재.폭발위험성)

  • Han, Ou-Sup;Lee, Keun-Won
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.376-377
    • /
    • 2011
  • 최근 Mg, Mg-Al합금, Al은 전자제품의 케이스, 차량의 휠 등의 신소재로서 활용성이 높아 사회적 수요가 급격히 늘고 있다. 이러한 수요 증가와 함께 관련 사업장에서는 취급 과정에서 폭발사고 위험성이 높아지고 있는데, 2010년도에는 국내 사업장에서 금속 분진에 의한 폭발사고가 4건이 발생하여 인명 및 재산피해가 발생하였다. Mg-Al합금의 폭발사고로 사망 1명과 부상 2명이 발생하였으며, Al분진의 폭발사고는 3건이 발생하여 사망 2명과 부상 3명의 인명피해로 이어졌다. 사고조사를 통하여 사업장에서의 금속분진에 대한 위험인식이 매우 낮은 것이 유사 사고가 반복되고 있는 가장 큰 이유로 알려지고 있는데, 이는 금속분진에 대한 부족한 안전기술정보와 밀접한 관련이 있다. 본 연구에서는 Mg, Mg-Al합금, Al등을 취급하는 관련 사업장에서 폭발사고 예방대책을 위하여 활용할 수 있는 폭발특성에 관한 안전기술정보 제공을 목적으로 하고 있다. 보다 구체적으로는 사고 다발 금속분진에 대한 위험성 이해에 도움을 될 수 있도록 동일 입경분포 조건에서의 위험성을 정량적으로 평가하였으며, 이를 위하여 각 금속분진의 동일 입경 조건에서 최대폭발압력, 폭발하한계 등의 폭발위험성 데이터를 실험적으로 조사 하였다. 조사한 시료는 평균입경 200 mesh의 Al, Mg, Mg-Al(60:40 wt%)로서 입도분석기(Beckman Coulter LSI 3320)를 사용하여 측정한 결과 평균입경은 약 $155{\mu}m$로 나타났다. Al분진의 농도변화에 따른 폭발압력을 조사한 결과, 최대폭발압력(Pmax)은 7.9 bar였으며 최대폭발압력상승속도 (dt/dP)max는 농도 $1500[g/m^3]$에서 322 [bar/s]로 최대가 되었으며 폭발 하한계(LEL)는 $70[g/m^3]$가 얻어졌다. 반면에 순수한 Mg의 LEL은 $30[g/m^3]$였으며 Pmax는 6.4 bar, (dP/dt)max는 100 [bar/s]가 얻어졌다. 이러한 결과로부터 LEL이 낮은 Mg는 Al보다 연소성이 큰 것으로 나타났으며, Al은 화염을 유지하는데 필요한 최저 열분해 가스농도를 확보하는데 Mg보다도 고농도의 분진이 필요함을 알 수 있었다. 또한 Mg-Al(60:40 wt%)의 LEL은 $50g/m^3$이었으며 Pmax는 9.4 bar, (dP/dt)max는 472 [bar/s]가 얻어졌다. 이러한 결과로부터 Mg-Al(60:40 wt%)합금의 연소성을 살펴보면 착화하기 쉬운 정도는 Mg와 Al의 성분비에 의해 변화하지만 Mg와 Al의 중간 정도로 나타나는 반면, Pmax는 Mg 또는 Al의 단독 물질 성분보다도 매우 큰 것을 알 수 있었다. 본 연구를 통하여 단일 성분의 Mg와 Al보다도 Mg와 Al이 일정 비율로 구성된 Mg-Al합금의 경우가 화재폭발 위험성이 증가한다는 사실을 알 수 있었으며, 이와 같은 폭발위험특성 자료를 활용하여 분진의 보관, 취급, 폐기 등의 지속적 관리가 필요하며 사업장 특성에 적합한 안전대책을 통한 사고예방대책이 요구된다.

  • PDF

Fire Experiment for a Water Curtain Nozzle in a Double Glazed Curtain Wall System (유리커튼월 수막시스템 분무헤드의 화재 실험 연구)

  • Kim, Sung-Won;Nam, Jiwoo;Cho, Seongwook;Ryou, Hong-Sun;Nam, Jun-Seok;Kim, Dong-Joon
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.31-40
    • /
    • 2016
  • Recently, a curtain wall system was applied to skyscrapers to prevent fire spreading along the vertical direction due to stack effect and outside air flow when a fire breaks out in skyscraper. Conventional sprinklers cannot prevent the spread of fire to the upstairs areas, which increases the loss of life and property. In this study, a water curtain nozzle that creates wider water coverage on the surface of glass and can prevent the spread of fire to the upstairs areas was developed. The spray pattern of the water curtain nozzle was compared with that of a sprinkler to determine performance of the water curtain nozzle. A fire experiment was constructed on the second floor to verify performance of the water curtain nozzle in preventing the spread of fire to the upstairs areas. The fire and watering experiment proved that the water curtain nozzle prevented more effectively the spread of fire than the conventional sprinkler. The position of first crack and critical temperature of fracture were also analyzed using numerical analysis.

Development of On-axis Raman Lidar System for Remotely Measuring Hydrogen Gas at Long Distance (원거리 수소 가스 원격 계측을 위한 On-axis 라만 라이다 장치 개발)

  • Choi, In Young;Baik, Sung Hoon;Lim, Jae Young;Cha, Jung Ho;Kim, Jin Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.3
    • /
    • pp.119-125
    • /
    • 2018
  • Hydrogen gas is an important and promising energy resource that has no emissions of pollutants during power generation. However, hydrogen gas is very dangerous because it is colorless, odorless, highly flammable, and explosive at low concentration. Conventional techniques for hydrogen gas detection are very difficult for measuring the hydrogen gas distribution at long distances, because they sample the gas to measure its concentration. Raman lidar is one of the techniques for remotely detecting hydrogen gas and measuring the range of the hydrogen gas distribution. A Raman lidar system with an on-axis optical receiver was developed to improve the range of hydrogen gas detection at long distance. To verify the accuracy and improvement in the range of detecting the hydrogen gas, experiments measuring the hydrogen gas concentration are carried out using the developed on-axis Raman lidar system and a gas chamber, to prevent explosion of the hydrogen gas. As a result, our developed on-axis Raman lidar system can measure a minimum hydrogen gas concentration of 0.66 volume percent at a distance of 50 m.

A Study on Flame Extinction in Oxymethane Combustion (메탄 산소 연소에 있어서 화염 소화에 대한 연구)

  • Kim, Tae Hyung;Kwon, Oh Boong;Park, Jeong;Keel, Sang-In;Yun, Jin-Han;Park, Jong Ho
    • Journal of the Korean Society of Combustion
    • /
    • v.20 no.4
    • /
    • pp.34-41
    • /
    • 2015
  • Oxy-methane nonpremixed flames diluted with $CO_2$ were investigated to clarify impact of radiation heat loss and chemical effects of additional $CO_2$ to oxidizer stream on flame extinction. Flame stability maps were presented with functional dependencies of critical diluents mole fraction upon global strain rate at several oxidizer stream temperatures in $CH_4-O_2/N_2$, $CH_4-O_2/CO_2$, and $CH_4-O_2/CO_2/N_2$ counterflow flames. The effects of radiation heat loss on the critical diluent mole fractions for flame extinction are not significant even at low strain rate in nonpremixed $CH_4-O_2/N_2$ diffusion flame, whereas those are significant at low strain rate and are negligible at high strain rate (> $200s^{-1}$) in $CH_4-O_2/CO_2$ and $CH_4-O_2/CO_2/N_2$ counterflow flames. Chemical effects of additional $CO_2$ to oxidizer stream on the flame extinction curves were appreciable in both $CH_4-O_2/CO_2$ and $CH_4-O_2/CO_2/N_2$ flames. A scaling analysis based on asymptotic solution of stretched flame extinction was applied. A specific radical index, which could reflect the OH population in main reaction zone via controlling the mixture composition in the oxidizer stream, was identified to quantify the chemical kinetic contribution to flame extinction. A good correlation of predicted extinction limits to those calculated numerically were obtained via the ratio between radical indices and oxidizer Lewis numbers for the target and baseline flames. This offered an effective approach to estimate extinction strain rate of nonpremixed oxy-methane flames permitting air infiltration when the baseline flame was taken to nonpremixed $CH_4-O_2/N_2$ flame.

The Effect of Oxygen and Chlorine Dioxide during Pulp Bleaching - The Effect of Hydroxyl Radical and Metal Ion - (펄프 표백시 산소와 이산화염소의 영향 - 수산기 라디칼의 생성과 금속이온의 영향-)

  • Yoon, Byung-Ho;Jo, Byoung-Muk;Lee, Myoung-Ku
    • Journal of Forest and Environmental Science
    • /
    • v.13 no.1
    • /
    • pp.153-165
    • /
    • 1997
  • Hydroxyl radicals were detected and their qualitative yields were estimated by using chemiluminescence method and $\gamma$-irradiation technique in oxygen or chlorine dioxide radicals bleaching conditions. The correlation of hydroxyl radical formation and lignin model(Apocynol) or carbohydrate model($\alpha$-D-glucopyranose and methyl-$\beta$-D-glucopyranoside) degradation was studied in the presence of metal ion or without metal ion. The results showed that the presence of metal ions efficiently affected the formation of hydroxyl radicals in oxygen bleaching process, in the order of $Cu^{2+}$ > $Mn^{2+}$ > $Mg^{2+}$ > $Fe^{2+}$, and these metal gave also rise to the degradation of carbohydrate. But it was found that the addition of $100{\mu}m\;Mg^{2+}$ gave an efficient protection against carbohydrate degradation and suppressed the hydroxyl radical formation under oxygen bleaching conditions. And the presence of $Cu^{2+}$ had a detrimental effect on the stability of carbohydrates, whereas the addition of $3{\mu}m\;Mn^{2+}$ surprisingly had a small protective effect on methyl--$\beta$-D-glucopyranoside. In the $ClO_2$ radical bleaching conditions the hydroxyl radical expected to generate from water or substrates was not detected in the presence of metals.

  • PDF