• Title/Summary/Keyword: 화상검사

Search Result 133, Processing Time 0.026 seconds

A Study on the development of Automated Optical Glass Inspection System (광학용 유리자동검사기 개발에 관한 연구)

  • 구마끼
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.03a
    • /
    • pp.82-87
    • /
    • 1998
  • Laser printer, faximile and copy machine are a few examples of OA(office automation) system. In such a system, the reflecting mirror has been employed for transmitting a target image to optical device. Therefore, to develope a good quality of optical system, the quality control of optical mirror was required. In recent years, considerable efforts have been directed toward the development of automated optical glass inspection system because the inspection is eye-fatigue and monotonous job for humans to perform. In this paper, we propose a inspection system applying algorithm of image processing for detecting defects of optical glass such as pinhole, scratch. From the experiments, the proposed inspection system shows reliable results.

  • PDF

Performance Advancement of Evaluation Algorithm for Inner Defects in Semiconductor Packages (반도체 패키지 내부결함 평가 알고리즘의 성능 향상)

  • Kim, Chang-Hyun;Hong, Sung-Hun;Kim, Jae-Yeol
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.6
    • /
    • pp.82-87
    • /
    • 2006
  • Availability of defect test algorithm that recognizes exact and standardized defect information in order to fundamentally resolve generated defects in industrial sites by giving artificial intelligence to SAT(Scanning Acoustic Tomograph), which previously depended on operator's decision, to find various defect information in a semiconductor package, to decide defect pattern, to reduce personal errors and then to standardize the test process was verified. In order to apply the algorithm to the lately emerging Neural Network theory, various weights were used to derive results for performance advancement plans of the defect test algorithm that promises excellent field applicability.

Temperament and Charcater Dimensions of Posttraumatic Stress Disorder in Burn Patients (외상 후 스트레스장애로 진단된 화상 환자의 기질 및 성격차원 특성)

  • Yoon, Suk-Chan;Ham, Byung-Joo;Byun, Jeong-Hyun;Eun, Heon-Jeong;Son, Hyeon-Gyun;Suh, Kuk-Hee;Choi, Ihn-Geun
    • Korean Journal of Biological Psychiatry
    • /
    • v.12 no.2
    • /
    • pp.159-164
    • /
    • 2005
  • Objective:The aim of this study was to evaluate the temperament and character profiles of the patients with posttraumatic stress disorder(PTSD) after burn injury. Methods:The study subjects consisted of 23 PTSD patients after burn injury, 24 patients not being diagnosed as PTSD after burn injury(non-PTSD) and 53 healthy controls. The assessment of PTSD was performed using clinician administered PTSD scale. All participants were instructed to complete the Temperament and Character Inventory(TCI), the Beck Depression Inventory and the State and Trait Anxiety Inventory of Spielberger. Results:The PTSD group after burn injury, compared with the non-PTSD group and the normal controls, had the higher novelty seeking and harm avoidance scores. But there were no differences in other dimensions in the TCI among the three groups. Conclusion:The results of this study suggest that the PTSD group after burn injury showed the specific properties of temperament and character compared with the non-PTSD group and the normal group.

  • PDF

The Weldability Estimation for the Purpose of Real-Time Inspection and Control (실시간 검사 및 제어를 목적으로 한 용접성 평가)

  • Lee, Jeong-Ick
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.3
    • /
    • pp.605-610
    • /
    • 2008
  • Through welding fabrication, user can feel unsatisfaction of surface quality because of welded defects, Generally speaking, these are called weld defects. For checking these defects effectively without time loss effectively, weldability estimation system setup is an urgent thing for detecting whole specimen quality. In this study, by laser vision camera, catching a rawdata on welded specimen profiles, treating vision processing with these data, qualitative defects are estimated from getting these information at first. At the same time, for detecting quantitative defects, whole specimen weldability estimation is pursued by multifeature pattern recognition, which is a kind of fuzzy pattern recognition. For user friendly, by weldability estimation results are shown each profiles, final reports and visual graphics method, user can easily determined weldability. By applying these system to welding fabrication, these technologies are contribution to on-line weldability estimation.

The Efficiency of External Heat Sources for Infrared Thermography Applied Concrete Structures and the Improvement of the Defect-identification (열화상 기법을 이용한 콘크리트 구조물 결함 검출시 열원의 효율 비교 및 결함검출 능력 향상)

  • Sim, Jun-Gi;Moon, Do-Young;Chung, Lan;Lee, Jong-Seh;Zi, Goangseup
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.5 s.57
    • /
    • pp.169-179
    • /
    • 2009
  • The purpose of this paper is to find an efficient heat source to amplify the surface temperature of damaged concrete structures for infrared thermography. we compare two different heat sources of far-infrared lamp and halogen lamp each other for their efficiency. The two heat sources were applied to the concrete specimens. Two different concrete specimens were used: one was the concrete containing internal void and the other was wrapped with partially unbonded fiber reinforced polymer sheet. it was found that the far-infrared lamp was more efficient than the halogen lamp. In addition, we propose a new algorithm to make the damage zone displayed clear in the image obtained from the thermographic operation. The algorithm is a combination of Gauss filtering process and the Prewitt mask operation.

Automatic Noncontact Ultrasonic Inspection Technique (비접촉식 초음파탐상방법 자동화 기술)

  • Kim, Y.G.;Ahn, B.Y.;Lee, S.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.13 no.4
    • /
    • pp.25-31
    • /
    • 1994
  • A system for EMAT, which generates ultrasound by electro-magnectic forces and performs nondestructive testing in noncontact, was established. By linking it with a 3 axis scanning system and a data acquisition and processing system the automation of EMAT testing was attempted. A EMAT sensor was fabricated and the directivity pattern of it was measured. To be suitable automation, it has a transmitter and a receiver in one case and the main beam direction of it can be controlled by the frequency of driving signal. A program which controls the EMAT system, the 3 axis scanner and the data acquisition and processing system was developed. It also processes acquired data and displays the processing results. IBM-PC/AT compatible PC was used as main controller and the stratage of the program is emulation of real devices on the PC monitor. To provide the performance of the established EMAT system, two aluminium blocks containing artificial flaws and a welded aluminium block were tested. The result of the tests were satisfactory.

  • PDF

An Intelligent Electronic Performance Support System for Semiconductor Testing Equipment (반도체 검사 장비를 위한 지능형 전자 성능 지원 시스템)

  • 이상용
    • Korean Journal of Cognitive Science
    • /
    • v.9 no.1
    • /
    • pp.31-39
    • /
    • 1998
  • This paper describes an electronic performance support system called HELPS(Handler Electronic Learning Performence Support) for semiconductor testing e equipment. The purpose of this system is to improve productivity of operators by providing just-in-time, on-the-job, mutimedia-based system information for operational support, training, and knowledge-based trouble shooting and repair. HELPS is composed of a operation module and a trouble shooting module. The operation module uses multimedia and hypermedia to provide the detailed and easily accessible information about equipment to users. Multimedia incorporate multiple. media forms including still and video images. animations 'texts' graphics. and audio. Hypermedia a are provided through a hierarchical information structure which offers not only specific information which is needed to perform a task to experienced operators. but detailed system guidance and information to novice operators. The trouble shooting module is composed of an integrated mutimedia-supported expert system which assists operators in trouble shooting and equipment repair. After diagnosis through the use of the expert system. multimedia advice is presented to the user in either still images with text or motion sequences with sound HELPS is evaluated in term of training time and trouble shooting and repair time. It improved productivity by saving more than 30% of the total time used without the system. This s system has the potential to improve productivity when it is used with ICAIOntellignet Computer Aided Instruction) and virtual reality.

  • PDF

Significance of Early Esophagoscopy in Corrosive Esophagitis (부식성 식도염에서의 조기 식도경술의 의의)

  • 임병석;봉정표;박순일;문태용;윤강묵
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1983.05a
    • /
    • pp.12.2-13
    • /
    • 1983
  • Corrosive injuries of the esophagus by accident or suicidal attempt, though decreasing in number, still represent an important problem of our national pathology. One of the most difficult problems facing any physician is the diagnosis and management of caustic ingestion. In order to determine the extent of esophageal bums, to prevent the potential complication, to increase the therapeutic effect, the use of esophagoscopy is an essential step, and it has lessened an unnecessary admission and treatment. The authors have found the value of early esophagoscopy in selected 41 corrosive esophagitis patient who were admitted to Dept. of ENT, Wonju medical college, Yonsei university between 1980. 1-1982. 12

  • PDF

Effective of Body Temperature Increasing during Brain MRI scan (MRI 검사 시 체온상승 효과: 1.5 T vs 3.0 T)

  • Kim, Myeong Seong;Lee, Jongwoong;Jung, Jaeeun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.49-54
    • /
    • 2017
  • As the Radiofrequency(RF) increases with the magnetic field strength, the wavelength of the RF excitation field becomes smaller, which leads to more the thermal effect in the human-body placed in the electric field. MRI scanner used was GE signa 1.5T, HDx 3.0T and Philips 3.0T with same routine clinical sequence protocol. Therefore temperature was measured before and after each scan. Taken the temperatures in the ear with ear infra-red type thermometer(Braun co). 3.0T were temperature increases more than $0.15^{\circ}C$ and GE 3.0T MRI equipment about $0.14^{\circ}C$ higher than the Philips 3.0T MRI(p<0.012). Psychogenic status was investigated by the survey respondents about their status can not just answer therefore, a little different from the expected. In our study of Thermal effect of clinical MRI with clinical protocol sequence, we found that the 3.0T in the body-temperature rise was greater than the 1.5T. Therefore, in clinical 3.0T examine the dangerous situation caused by the temperature rise occurred (burns, impaired thermoregulatory mechanism in patients with high-temperature damage, exhaustion occurs due to excessive sweating), not to appear the more watched the patient's condition with procedure.

Skin regeneration by spray of fibrin gel containing keratinocytes and epidermal growth factor

  • Gwak, So-Jung;Kim, Sang-Soo;Choi, Cha-Yong;Kim, Byung-Soo
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.356-358
    • /
    • 2003
  • The use of cultured epidermal sheet grafts for large full-thickness wound has been tempered by weak points such as long culture periods, difficulty in handling the fragile sheets, high costs and the detachment of the skin cells from the culture dishes by enzymatic digestion. To overcome the drawback of epidermal sheet grafts, we have developed a transplantation method to spray the cultured human keratinocytes with the mixtures of rhEGF and fibrin gel matrix to the full-thickness wounds on the dorsum of the athymic mice to regenerate epithelial layers. Wound biopsies were retrieved at 7, 14 and 21 days after transplantation and retrieved biopsies were analyzed by histology and immunohistochemistry. Transplanted keratinocytes and EGF-fibriin gel accelerated wound regeneration compared with control groups. The technique developed in this study overcomes the drawbacks of the current cultured epidermal sheet grafts and accelerates epidermal wound healing.

  • PDF