• Title/Summary/Keyword: 홍수터여과

Search Result 8, Processing Time 0.028 seconds

A Primary Study on the Potential of Floodplain Filtration in Korea (우리나라에서 홍수터여과의 가능성에 대한 기초조사)

  • Choi, Myung-Ho;Kim, Kyeong-Soo;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.1
    • /
    • pp.70-78
    • /
    • 2009
  • Floodplain areas of major South Korean rivers were determined by analyzing topographical maps and hydraulic properties of floodplain soil were measured using disc tension infiltrometer. To assess the possibility of treating secondary effluents of municipal wastewater with floodplain soil, a computer code for the analysis of unsaturated flow in soil was employed along with searches conducted in the literature. Based on the data generated, an estimate of total floodplain filtration capacity in Korea was obtained. The results of our study reveal that Korean floodplains have surface soil that is adequate for treating water. Moreover, the distributions of floodplains are substantial over the entire reaches of the rivers, indicating that the conditions are favorable for floodplain filtration as additional treatment of secondary effluent. The capacity of floodplain filtration in Korea is circa 182,000,000 $m^3$/day and most of the rivers are estimated to have enough capacity of floodplain filtration to meet all the secondary effluent, indicating that this technology may be expected to make further improvements on river water quality. Furthermore, this method may also be applied to better the source-water quality for drinking water.

A Study on the Optimum Design of Horizontal Collectors in Floodplain Filtration (홍수터여과에서 집수관의 최적설계 연구)

  • Pi, Seong-Min;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.6
    • /
    • pp.430-437
    • /
    • 2012
  • In order to obtain information on the design parameters of the horizontal laterals in floodplain filtration, laboratory-scale sand-box experiments were performed where the head distributions on the laterals and the groundwater profiles were measured according to the change in parameters including lateral diameter, hydraulic conductivity of the sand, water level at the well and raw-water supply rate. Measured data were analyzed using a numerical code in order to identify the discharge intensity distribution along the laterals. It was observed from the result that the lowering of the water level at the well had minimal adverse effect on the performance of the floodplain filtration. Results also elucidated that the low conveyance of the laterals to transmit the filtrate was compensated and supplemented by a natural augmentation in horizontal conveyance through the aquifer when the raw-water supply rate exceeded the adequate recovery rate. With this mechanism, the water quality is expected to improve further since the travel distance through the aquifer is amplified. Based on these findings it can be suggested that the diameter of the lateral used in the floodplain filtration may be smaller than those in riverbank/bed filtration. It was also found that the ratio between the head loss occurring in a lateral and the total head loss in the floodplain filtration was proportional to the exit velocities of the laterals, which may be used to design and/or evaluate the lateral in floodplain filtration.

A Study on Clogging and Water Quality Improvement in Floodplain Filtration with Flood/rest Raw-water Supply (범람/휴지식 홍수터여과에서 폐색현상 및 수질개선도 연구)

  • Kim, Hoh-Seok;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.2
    • /
    • pp.120-131
    • /
    • 2011
  • A pilot-scale experiment of floodplain filtration with a filtration depth of 3.6m was performed employing flood/rest type raw-water supply system in an effort to find ways to improve river water quality by additional treatments of discharged effluent from sewage treatment plant. Soil samples were taken from 3 sites including Gumi, Daegu and Gimhae along the Nakdong river. Reductions of infiltration rates following increases in operating time was investigated in each soil sample, along with the analysis of removal efficiencies of various pollutants according to different depths and infiltration rates. The results show incremental development of clogging on the soil surface with increases in operation time, and illustrate exponential decrease in the infiltration rate. The time required for the removal of the clog from the soil surface was longer than 2 weeks for all soil samples analyzed. The stable infiltration rates for soils were 5 m/day for Gumi and for Daegu and Gimhae was 1 m/day. In unsaturated soils dissolved oxygen levels increased following the increase of filtration depth, suggesting that alternating application of flood and rest for raw-water supply effectively keeps the soil environment aerobic. For all soils, the nature of pollutant removal depending on the depth of filtration remained the same regardless of the infiltration rate. Most of the BOD and turbidity were removed within 1.2 m, about 30% of COD was removed within 3.6m and was expected to be removed further with increases in filtration depth. Nitrification occurred near the surface of all soils; however there was no significant removal of nitrogen in the filtration depths tested in this study. Although removal rate of phosphorus was low for Gumi's soil, it was high enough for other soils, suggesting that the method developed in this study could significantly improve river water quality.

Removal of Organic Matter and Nitrogen from River Water in a Model System of Floodplain Filtration (홍수터 여과 모형을 이용한 하천수중의 유기물과 질소 제거)

  • Ha, Hyun-Soo;Kim, Sang-Tae;Kim, Seung-Hyun;Jeong, Byeong-Ryong;Lee, Young-Deuk;Eum, Jin-Sup;Ji, Seung-Hwan;Chung, Jong-Bae
    • Applied Biological Chemistry
    • /
    • v.45 no.2
    • /
    • pp.84-91
    • /
    • 2002
  • If contaminated river water is sprayed over the floodplain, organic matter and nitrogen would be removed by microbial processes in the rhizosphere of vegetation during the filtration through soil. In this study we tested the organic matter and nitrogen removal from contaminated river water by the floodplain filtration. Model system of floodplain was constructed using a PVC pipe (15 cm i.d. ${\times}$ 150 cm L) which was packed with a loamy sand soil collected from a floodplain in Nakdong river. The model system was instrumented with soil solution samplers and gas samplers. A river water collected from Omogcheon in Kyongsan was sprayed from top of the model system at three different rates. The concentration of organic matter, DO, $NO_3^-$, $NO_2^-$, $NH_4^+$, $N_2$ and $N_2O$, and redox potential were measured as a function of soil depth for 24 days after the system reached a steady state. When river water was sprayed at the rates of 40.8 and 68.0 $l/m^2/day$, a significant reductive condition for denitrification was developed at below 5-cm depth of the soil. When the water reached at 90-cm depth of the soil, COD and concentration of inorganic nitrogen were lowered, on an average, from 18.7 to 5 mg/l and from 2.7 to 0.4 mg/l, respectively. $N_2$ comprised most of the N gas evolved from denitrification and $N_2O$ concentrations emitted at the surface of soil were less than 1 {\mu}l/l. The effective removal of organic matter and nitrogen by the filtration in the model system of floodplain demonstrates that the native floodplains, which include rhizosphere of vegetation at the top soil, could be more effective in the treatment of contaminated river waters and other industrial waste waters containing high concentration of organic matter and nitrogen.

An Experimental Study on the Design Factors of Raw-water Supply System in Floodplain Filtration (홍수터여과에서 원수공급체계의 설계요소에 대한 실험연구)

  • Kim, Hoh-Seok;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.11
    • /
    • pp.957-964
    • /
    • 2009
  • Sand tank experiments were performed along with on-site supplier experiments in order to obtain design factors for the raw-water supply system in floodplain filtration. Results of the sand tank experiment elucidated that the infiltration rate was approximately proportional to the soil permeability and was not significantly influenced by short periods of rest. The average daily infiltration rate calculated by taking both flood and rest periods into account increased with increasing flood period, and was observed to reach an asymptote. Under the conditions of this study, the maximum infiltration rates obtained for both Daegu and Mulgeum soils with 15 min/ 30 min of rest/flood periods were 6.3 m/day and 1.4 m/day respectively, which were 42% and 70% of their hydraulic conductivities, respectively. The process of soil filtration resulted in a gradual decrease of hydraulic conductivity; a decrease of 27% was observed for the soil of Mulgeum over a period of 8 days. From the data obtained from the supplier experiment, it was evident that the radius of the flooded area increased as the supply rate increased for soils of Gumi and Sangju, however, there was an inverse correlation between hydraulic conductivity and the rate of increase in the radius. Results also showed that the time required to cover the entire soil surface with water, in other words, the time to reach the maximum flood radius from the commencement of the water emission was as short as 3 to 4 minutes for all the soils. Also, the average infiltration rate for the entire flood period did not change significantly when the rest period was shorter than an hour.

Rhizosphere Enhances Removal of Organic Matter and Nitrogen from River Water in Floodplain Filtration (홍수터 여과를 이용한 하천수의 질소와 유기물 제거에 미치는 근권의 효과)

  • Jeong, Byeong-Ryong;Chung, Jong-Bae;Kim, Seung-Hyun;Lee, Young-Deuk;Cho, Hyun-Jong;Baek, Nam-Joo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.36 no.1
    • /
    • pp.8-15
    • /
    • 2003
  • If contaminated river water is sprayed over a floodplain, the microbial processes can simultaneously remove organic matter and nitrogen during the infiltration through the sediment profile. The effect of rhizosphere on the removal of organic matter and nitrogen from contaminated river water was investigated using floodplain lysimeters. River water was sprayed at a rate of $68.0L\;m^{-2}\;d^{-1}$ on the top of the lysimeters with or without weed vegetation on the surface, Concentrations of $NO_3$, $NH_4$ and dissolved oxygen (DO), and chemical oxygen demand (COD) and Eh in water were measured as functions of depth for 4 weeks after the system reached a steady state water flow and biological reactions. A significant reductive-condition for denitrification developed in the 30-cm surface profile of lysimeters with weeds. At a depth of 30 cm, COD and $NO_3$-N concentration decreased to 5.2 and $0.9mg\;L^{-1}$ from the respective influent concentrations of 18.2 and $9.8mg\;L^{-1}$. The removal of $NO_3$ in lysimeters with weeds was significantly higher than in those without weeds. Vegetation on the top was assumed to remove $NO_3$ directly by absorption and to create more favorable conditions for denitrification by supply of organic matter and rapid $O_2$ consumption, In the lysimeters without weeds, further removal of $NO_3$ was limited by the lack of an electron donor, i.e. organic matter. These results suggest that the filtration through native floodplains, which include rhizospheres of vegetation on the surface, can be effective for the treatment of contaminated river water.

The Characteristics of Sediment Discharge in 2010 (본 2010년 하천 유사량 특성 분석)

  • Go, Ju-Yeon;Lee, Yeon-Kil;Jung, Sung-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.332-332
    • /
    • 2011
  • 하천 유사량 특성 분석은 하천유역 내의 수리구조물 설계 및 유지관리, 하천개수 및 하도의 안정, 홍수터 관리, 저수지 설계 및 운영 등 수자원 개발 및 관리를 위한 하천계획의 필요한 요소 중 하나이며 현장 측정에서 분석까지 정밀한 일련의 과정을 통해서 알아낼 수 있다. 본 연구에서는 6개 지점(여주, 왜관, 진동, 공주, 나주, 구례2)에 대해 유사량 특성 분석을 수행하였다. 부유사량은 강우가 집중되는 홍수기(왕복수심적분법; D-74측정장비 / 표면채취법)를 중심으로 측정하였고 하상토의 경우는 Grab Sampler(60L), 선격자법 등을 이용하여 홍수기 전 후로 2회 채취하였다. 채취된 시료는 특성에 따라 여과법(부유사농도), BW관법(부유사입도분포), 체분석법(하상토입도분포)으로 분석하였으며, 이를 통해 산정된 평균 부유사농도, Oden Curve와 입도분포곡선 및 수리량(수위, 유속, 측정수심, 수면폭, 수면경사, 수온)등의 자료를 이용하여 총유사량(Modified Einstein 방법)을 추정하였다. 본 연구 결과는 다음과 같다.: 1) 유량-부유사량 및 총유사량 관계: 유량-부유사량의 관계에 있어 대체적으로 일관된 경향성이 나타났으며 총유사량과의 관계 역시 부유사량과 비슷한 경향성을 보임. 일부 성과의 경우, 총유사량과의 관계에 있어 Modified Einstein 조건의 불충족(자갈하상재료 또는 저유속)으로 부유사량과 동일추정이거나 추정불가 및 이상치가 나타남. 2) 유량-부유사량 특성: 전체적으로 루프현상을 보이며 초기 강우 사상에서는 더 많은 유사량이 발생하는데 이는 초기 강우에 의해 유사 이송이 활발하게 이루어지는 일반적인 특성임. 또한 수위 상승-하강에 따른 부유사량 자료가 더욱더 확보된다면 수위 상승과 하강부로 구분하여 분석하는 것도 의의가 있을 것으로 판단됨. 3) 유량-유사량관계식 개발: 개발된 관계식은 총유사량이 아닌 부유사량으로 개발되었으며, 측정성과들 간의 상관계수가 0.9723(구례2 지점) ~ 0.8490(나주 지점)으로 분석됨. 또한 개발된 관계식에 대한 신뢰도 분석을 실시하지 않았기 때문에 적용 시에는 주의가 요구됨.

  • PDF

Analysis of Compound Open Channel Flow Using Large Eddy Simulation (LES) (Large Eddy Simulation (LES)을 이용한 복단면 개수로 흐름 분석)

  • Lee, Du Han
    • Ecology and Resilient Infrastructure
    • /
    • v.4 no.1
    • /
    • pp.54-62
    • /
    • 2017
  • This study investigated compound open channel flow using OpenFOAM Large Eddy Simulation (LES). Large eddy simulations were carried out by solving the filtered continuity and momentum equations numerically. One equation LES and non-uniform grid were applied to capture the anisotropic turbulence and secondary flow near the wall. The results of large eddy simulations of turbulent flow in a compound open channel with deep and shallow flood plain depths are presented. These LESs are validated with experimental data, resulting in a good agreement between measured and calculated data. The role of anisotropic turbulence in generating secondary currents is illustrated.