• Title/Summary/Keyword: 홈 각도

Search Result 324, Processing Time 0.025 seconds

The Prototype and Structure of the Water Supply and Drainage System of the Wolji Pond During the Unified Silla Period (통일신라시대 월지(月池) 입·출수 체계의 원형과 구조)

  • Kim, Hyung-suk;Sim, Woo-kyung
    • Korean Journal of Heritage: History & Science
    • /
    • v.52 no.4
    • /
    • pp.124-141
    • /
    • 2019
  • This research explored the relationship between the water quality issue of Wolji Pond (Anapji Pond) with the maintenance of the channel flow circulation system. The water supply and drainage system closely related to the circulation system of pond has been reviewed, rather than the existing water supply and drainage system that has been analyzed in previous studies. As a result of reviewing the water supply system, it has been learned that the water supply system on the southeastern shore of Wolji Pond, being the current water supply hole, has been connected to the east side garden facility (landscaping stone, curved waterway, storage facility of water) between the north and south fence and the waterway. This separate facility group seems to have been a subject of the investigation of the eastern side of Wolji Pond, with the landscaping stones having been identified in the 1920's survey drawings. The water supply facility on the southeastern shore, being the suspected water supply hole, seems to have some connection with the granite waterway remaining on the building site of Imhaejeon (臨海殿) on the southern side of Wolji Pond. It is inferred that it provides clean water, seeing that the slope towards the southwestern shore of Wolji Pond becomes lower, the landscaping stones have been placed in the filter area, and it is present in the 1920's survey drawings and the water supply hole survey drawing of 1975. The water drainage facility on the northern shore is composed of five stages. The functions of the wooden waterway and the rectangular stone water catchment facility seem not to be only for the water drainage of Wolji Pond. In light of the points that there are wood plugs in the wooden waterway and that there is a water catchment facility in the final stage, it is judged that the water of Balcheon Stream (撥川) may be charged in reverse according to this setup. Namely, the water could enter and exit in either direction in the water drainage facility on the northern shore It also seems that the supply to the wooden waterway could be opened and shut through the water catchment facility of rectangular stone group as well. The water drainage facility on the western shore is very similar to the water drainage facility on the northern shore, so it is difficult to avoid the belief that it existed during the Silla Dynasty, or it has been produced by imitating the water drainage facility on the northern shore at some future point in time. It seems to have functioned as the water drainage facility for the supply of agricultural water during the Joseon Dynasty. The water supply and drainage facilities in Wolji Pond have been understood as a systematized distribution network that has been intertwined organically with the facility of Donggung Palace, which was the center of the Silla capital. Water has been supplied to each facility group, including Wolji Pond, through this structure; it includes the drainage system connecting to the Namcheon River (南川) through the Balcheon Stream, which was an important canal of the capital center.

A comparative study between Korea and the USA on the development process in retail trade & its changing locations (소매업의 발달과정과 입지 변화에 관한 한.미 비교 연구)

  • Jeon, Kyung-Sook
    • Journal of the Korean association of regional geographers
    • /
    • v.6 no.2
    • /
    • pp.21-40
    • /
    • 2000
  • The retail trades in many countries have changed recently according to the high quality, diversification, and marked individuality of consumer needs. Under the continually competing system of the WTO agreement, corporations based in the USA and the EU try to raise their market share in other countries so it is inevitable for Korean retail enterprises to compete with them. This paper is aimed at contributing to the efficient growth for Korean retail trade from the analysis of the development process in retail trade and its changing locations comparing Korea and the USA. Retailers in the USA have practiced diversified marketing strategies considerably in order to survive in a rapidly changing retailing environment. American retailing, which has the most advanced marketing system in the world, has been of growing concern to marketing strategies in Korea. The following is a brief summary of this study. 1. Speedy and higher quality consumption is needed in accordance with the great increase in the single-family household and the female labor force participation both in Korea and in the USA. Senior citizens have become a new consumer group due to the aging population. In the future the retail trade will switch over to diversified retail formats and internet shopping as countries are transformed into information and communication societies. 2. In Korea, the former retail system characterized by markets and department stores has been greatly changed since the late 1980s with emphasis on high quality and convenience in consumption behaviors, with large domestic enterprises and foreign distribution corporations participating in Korean retailing. In the USA, retailing mergers and takeovers by major retails, bankruptcies, and extra-large shopping centers have emerged since the late 1980s. Recently, the USA retailing formats have been changed from the lower price-oriented discount types to the large scale theme parks. Much emphasis was put on entertainment, resorts, and convention centers. On the other hand, non-store types, such as the internet shopping, the CATV shopping, as well as catalog and mail-order sales are drastically increasing, although the proportion of their sales is low up to now. 3. In Korea, most of the retail facilities are concentrated in Seoul and the Metropolitan Region, and the distribution ratio of facilities came to 52% in 1997. The periodic markets, traditional markets which open on a periodic basis, are located mainly in Chollanam-do and Kyungsangbuk-do. The large-sized discount stores have expanded their locations to the over-crowded apartment complexes in new towns, located in the Metropolitan Region, and the large provincial cities, unlike the suburban locations in the USA. Therefore we needed to give attention to the locational relations in retail facilities between Seoul & the Metropolitan Region and rural settlement areas. In the USA, urban areas grew quickly with the development of the automobile in the 1920s, and the location of stores changed from a dispersed style centering around rural areas to a centralized one in urban areas. There is an accelerated growth for suburban areas, which have grown rapidly since 1950. As the membership warehouse clubs were introduced in the 1970s, the decentralization of location was more intensified. On the other hand, inner cities were revitalized by rearranging existing facilities to cope with suburban areas. And the location-free virtual retailing & TV shopping are also growing every year. 4. In view of the above, the continuous and desirable development devices in Korean retail trade are summarized as follows: First, the countermeasures against economies of scale, increase in retailing sales, and rise of a employment percentage in retailing are in need. Second, a scheme of lowering the proportion of food retail sales, and increasing a ratio of durable goods sales need to be worked out. Third, the original ideas are needed to apply positively information, communication and technology to retailing, to graft the traditional types on modem ones based on the social culture. Fourth, strategies are needed to strengthen the competitiveness of our retail trade through cooperation and chains of smaller retailers, the large enterprises participating in the distribution industry. Fifth, in order to realize the above, the retail industry, the administration, and the academic world should support the retail segment with concern and a practical strategy plan.

  • PDF

Development of a complex failure prediction system using Hierarchical Attention Network (Hierarchical Attention Network를 이용한 복합 장애 발생 예측 시스템 개발)

  • Park, Youngchan;An, Sangjun;Kim, Mintae;Kim, Wooju
    • Journal of Intelligence and Information Systems
    • /
    • v.26 no.4
    • /
    • pp.127-148
    • /
    • 2020
  • The data center is a physical environment facility for accommodating computer systems and related components, and is an essential foundation technology for next-generation core industries such as big data, smart factories, wearables, and smart homes. In particular, with the growth of cloud computing, the proportional expansion of the data center infrastructure is inevitable. Monitoring the health of these data center facilities is a way to maintain and manage the system and prevent failure. If a failure occurs in some elements of the facility, it may affect not only the relevant equipment but also other connected equipment, and may cause enormous damage. In particular, IT facilities are irregular due to interdependence and it is difficult to know the cause. In the previous study predicting failure in data center, failure was predicted by looking at a single server as a single state without assuming that the devices were mixed. Therefore, in this study, data center failures were classified into failures occurring inside the server (Outage A) and failures occurring outside the server (Outage B), and focused on analyzing complex failures occurring within the server. Server external failures include power, cooling, user errors, etc. Since such failures can be prevented in the early stages of data center facility construction, various solutions are being developed. On the other hand, the cause of the failure occurring in the server is difficult to determine, and adequate prevention has not yet been achieved. In particular, this is the reason why server failures do not occur singularly, cause other server failures, or receive something that causes failures from other servers. In other words, while the existing studies assumed that it was a single server that did not affect the servers and analyzed the failure, in this study, the failure occurred on the assumption that it had an effect between servers. In order to define the complex failure situation in the data center, failure history data for each equipment existing in the data center was used. There are four major failures considered in this study: Network Node Down, Server Down, Windows Activation Services Down, and Database Management System Service Down. The failures that occur for each device are sorted in chronological order, and when a failure occurs in a specific equipment, if a failure occurs in a specific equipment within 5 minutes from the time of occurrence, it is defined that the failure occurs simultaneously. After configuring the sequence for the devices that have failed at the same time, 5 devices that frequently occur simultaneously within the configured sequence were selected, and the case where the selected devices failed at the same time was confirmed through visualization. Since the server resource information collected for failure analysis is in units of time series and has flow, we used Long Short-term Memory (LSTM), a deep learning algorithm that can predict the next state through the previous state. In addition, unlike a single server, the Hierarchical Attention Network deep learning model structure was used in consideration of the fact that the level of multiple failures for each server is different. This algorithm is a method of increasing the prediction accuracy by giving weight to the server as the impact on the failure increases. The study began with defining the type of failure and selecting the analysis target. In the first experiment, the same collected data was assumed as a single server state and a multiple server state, and compared and analyzed. The second experiment improved the prediction accuracy in the case of a complex server by optimizing each server threshold. In the first experiment, which assumed each of a single server and multiple servers, in the case of a single server, it was predicted that three of the five servers did not have a failure even though the actual failure occurred. However, assuming multiple servers, all five servers were predicted to have failed. As a result of the experiment, the hypothesis that there is an effect between servers is proven. As a result of this study, it was confirmed that the prediction performance was superior when the multiple servers were assumed than when the single server was assumed. In particular, applying the Hierarchical Attention Network algorithm, assuming that the effects of each server will be different, played a role in improving the analysis effect. In addition, by applying a different threshold for each server, the prediction accuracy could be improved. This study showed that failures that are difficult to determine the cause can be predicted through historical data, and a model that can predict failures occurring in servers in data centers is presented. It is expected that the occurrence of disability can be prevented in advance using the results of this study.

Development of Supplemental Equipment to Reduce Movement During Fusion Image Acquisition (융합영상(Fusion image)에서 움직임을 줄이기 위한 보정기구의 개발)

  • Cho, Yong Gwi;Pyo, Sung Jae;Kim, Bong Su;Shin, Chae Ho;Cho, Jin Woo;Kim, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.84-89
    • /
    • 2013
  • Purpose: Patients' movement during long image acquisition time for the fusion image of PET-CT (Positron Emission Tomography-Computed Tomography) results in unconformity, and greatly affects the quality of the image and diagnosis. The arm support fixtures provided by medical device companies are not manufactured considering the convenience and safety of the patients; the arm and head movements (horizontal and vertical) during PET/CT scan cause defects in the brain fundus images and often require retaking. Therefore, this study aims to develop patient-compensation device that would minimize the head and arm movements during PET/CT scan, providing comfort and safety, and to reduce retaking. Materials and Methods: From June to July 2012, 20 patients who had no movement-related problems and another 20 patients who had difficulties in raising arms due to shoulder pain were recruited among the ones who visited nuclear medicine department for PET Torso scan. By using Patient Holding System (PHS), different range of motion (ROM) in the arm ($25^{\circ}$, $27^{\circ}$, $29^{\circ}$, $31^{\circ}$, $33^{\circ}$, $35^{\circ}$) was applied to find the most comfortable angle and posture. The manufacturing company was investigated for the permeability of the support material, and the comfort level of applying bands (velcro type) to fix the patient's head and arms was evaluated. To find out the retake frequency due to movements, the amount of retake cases pre/post patient-compensation were analyzed using the PET Torso scan data collected between January to December 2012. Results: Among the patients without movement disorder, 18 answered that PHS and $29^{\circ}$ arm ROM were the most comfortable, and 2 answered $27^{\circ}$ and $31^{\circ}$, respectively. Among the patients with shoulder pain, 15 picked $31^{\circ}$ as the most comfortable angle, 2 picked $33^{\circ}$, and 3 picked $35^{\circ}$. For this study, the handle was manufactured to be adjustable for vertical movements. The material permeability of the patient-compensation device has been verified, and PHS and the compensation device were band-fixed (velcro type) to prevent device movements. A furrow was cut for head fixation to minimize the head and neck movements, fixing bands were attached for the head, wrist, forearm, and upper arm to limit movements. The retake frequency of PET Torso scan due to patient movements was 11.06% (191 cases/1,808 patients) before using the movement control device, and 2.65% (48 cases/1,732 patients) after using the device; 8.41% of the frequency was reduced. Conclusion: Recent change and innovation in the medical environment are making expensive medical image scans, and providing differentiated services for the customers is essential. To secure patient comfort and safety during PET/CT scans, ergonomic patient-compensation devices need to be provided. Therefore, this study manufactured a patientcompensation device with vertically adjustable ergonomic ROM according to the patient's body shape and condition during PET Torso scan. The defects in the basal ganglia images due to arm movements were reduced, and retaking was decreased.

  • PDF