• Title/Summary/Keyword: 홀더

Search Result 193, Processing Time 0.03 seconds

A Study on the Blankholding Force in Deep Drawing Process (디프 드로잉 가공시 블랭크 홀더력에 관한 연구)

  • 이종국;강명순
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.5
    • /
    • pp.886-900
    • /
    • 1989
  • The purpose of this paper is to obtain the effect of blankholding force in deep drawing process. Flange deformation is analysed by theoretical approach in order to apply the optimum blankholding force to the blank. As the result, the upper and lower blankholding force is determined in terms of variables in deep drawing process. Experiment are carried out with the high stiffness spring-type blankholder system. Theoretical upper blankholding force are relatively good agreement with experimental result and the range of initial blankholding forces for various materials tested are found by experiment.

LiF TLD in TLD Holder for In Vivo Dosimetry (생체 내 선량측정을 위한, TLD홀더에 넣은 LiF TLD)

  • Kim Sookil;Loh John J.K.;Min Byungnim
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.293-299
    • /
    • 2001
  • Prupose : LiF TLD has a problem to be used in vivo dosimetry because of the toxic property of LiF. The aim of this study is to develop new dosimeter with LiF TLD to be used in vivo dosimetry. Materials and methods : We designed and manufactured the teflon box(here after TLD holder) to put TLD in. The external size of TLD holder is $4\times4\times1\;mm^3$ To estimate the effect of TLD holder on TLD response for radiation, the linearity of TLD response to nominal dose were measured for TLD in TLD holder. Measurement were peformed in the 10 MV x-ray beam with LiF TLD using a solid water phantom at SSD of 100 cm. Percent Depth Dose (PDD) and Tissue-Maximum Ratio (TMR) with varying phantom thickness on TLD were measured to find the effect of TLD holder on the dose coefficient used for dose calculation in radiation therapy. Results : The linearity of response of TLD in TLD holder to the nominal dose was improved than TLD only used as dosimeter And in various measurement conditions, it makes a marginnal difference between TLD in TLD holder and TLD only in their responses. Conclusion : It was proven that the TLD in TLD holder as a new dosimetry could be used in vivo dosimetry.

  • PDF

유연 공구 홀더를 가진 다관절 로봇 매니퓰레이터를 이용한 디버링 시스템

  • 최형식;정경식;김무경;황규득
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.285-285
    • /
    • 2004
  • 본 논문에서는 유연 공구 홀더를 가진 다관절 매니퓰레이터 로봇을 이용한 디버링 시스템에 대한 연구를 수행하였다. 로봇을 이용한 디버링 작업에서 버 공구(Rotary file)의 강성과 로봇의 강성으로 인해 작업 시 발생할 수 있는 각종 오류를 방지할 수 있는 소형의 3자유도 유연 공구 홀더(Flexible Tool Holder)를 개발하여 이에 대한 분석을 하였다. 개발한 유연 홀더를 새로운 구조의 다관절 로봇 매니퓰레이터를 이용하여 디버링 시험을 수행하였다.(중략)

  • PDF

Analysis of Vertex Refractive Power Accuracy of Soft Contact Lens with Holder Type (홀더종류에 따른 소프트 콘택트렌즈의 정점굴절력 측정의 정확도 분석)

  • Lee, Min-Jae;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.105-115
    • /
    • 2015
  • Purpose: The accuracy for measuring the refractive power of hydrogel contact lenses by spectacle lens holder and contact lens holder was evaluated. The accuracy for each sample was also analyzed with water content and diopter categories. Methods: The hydrogel contact lenses used for measurement were classified into three categories in water content (38%, 43%, 58%). Also, three diopter categories of refractive power were used such as -3.000 D, -7.000 D, -10.000 D. And also, the reliability of measurement results were evaluated by measuring refractive power with spectacle lens holder and contact lens holder using an Manual lensmeter. Results: In case of spectacle lens holder method, the average value of refractive power was -3.3273D for -3.0000 D, -7.1306 D for -7.0000 D and -10.2944 D for -10.0000 D, respectively. In case of contact lens holder method, the average value of refractive power was -3.1060 D for -3.0000 D, -7.0028 D for -7.0000 D and -10.2611 D for -10.0000 D, respectively. In measurement of all diopters, the accuracy of contact lens holder method was better than spectacle lens holder method. Conclusions: From these results, it is judged that the refractive power of soft contact lens by manual lensmeter with contact lens holder have a higher accuracy than spectacle lens holder.

Manufacturing of Sample Holder for the Property Analysis in Millimeter Wave Range (밀리미터파 전파특성 분석용 샘플홀더 제작)

  • Choi, Chang-Mook;Lim, Bong-Taeck
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.311-314
    • /
    • 2010
  • 본 논문에서는 밀리미터파 대역 전파특성 분석용 샘플홀더 제작을 위하여 전파의 도파이론을 정립하고 밀리미터파 W-bnad(75 GHz ~ 110 GHz) 주파수 대역에 알맞은 도파관형 샘플홀더를 설계 및 실 제작하였다. 그리고 제작된 샘플홀더를 테스트하기 위하여 샘플시료를 제작하여 재료정수 및 전파흡수능을 측정하고 분석하였다. 분석결과 샘플시료 특성을 정확하게 측정할 수 있음을 확인하였으며, 향후 이 측정 샘플홀더는 밀리미터파 대역 전파특성 분석을 위해 매우 유용하게 쓰일 수 있을 것이다.

  • PDF

Thermoelectric Peltier Module Applications of Cold/Hot Cup-holder (열전소자의 냉온컵홀더 응용기술)

  • Soh, Dea-Wha
    • Journal of the Speleological Society of Korea
    • /
    • no.75
    • /
    • pp.65-71
    • /
    • 2006
  • 팰티어-열전소자를 응용한 냉온컵홀더를 구성하는 응용기술을 제안하였다. 열전소자의 용량에 제한을 받기 때문에 가열 또는 냉각을 위해서는 충분한 용량을 뒷받침 해 줘야 한다. 따라서 컵홀더와 같은 휴대 필요성이 요구되거나 휴대 가능한 소형기기의 경우에는 온열 또는 냉각 상태를 유지시키는 보온기능을 갖는 온열기기로써의 적합성을 확인하였다.

Numerical Study on Ground Vibration Reduction and Fragmentation in a Controlled Blasting Utilizing Directional U Shape Charge Holder (U형 장약홀더를 이용한 발파공법에서 지반진동 저감특성 및 파괴효율에 관한 수치해석적 연구)

  • Kim, Hyon-Soo;Baek, Beom-Hyun;Oh, Se-Wook;Han, Dong-Hun;Cho, Sang-Ho
    • Explosives and Blasting
    • /
    • v.34 no.1
    • /
    • pp.11-18
    • /
    • 2016
  • It is necessary to minimize ground vibration and noise due to blasting work in urban environment. The blast induced ground vibration and noise are generally generated by a portion of detonation energy, where most of the energy is utilized for rock breakage and movement of rock mass. Recently a blast method utilizing U-shaped steel charge holder was suggested to reduce the ground vibration without decreasing destructive power toward the free surface. In this study, single hole blasting utilizing U-shaped steel charge holder were simulated and the stress waves caused by the detonation of explosives were monitored using AUTODYN software. In order to examine the fragmentation efficiency of the U-shaped steel charge holder, one free face blasting models which adapt the blast induced stress waves were simulated by dynamic fracture process analysis (DFPA) code. In addition, the general blasting models were also simulated to investigate the fragmentation effectiveness of the U-shaped steel charge holder in rock blasting.

A Study on Manufacturing of Sample Holder for the EM Property Analysis in W-band (W-band 전파특성 분석용 샘플홀더 제작에 관한 연구)

  • Choi, Chang-Mook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.6
    • /
    • pp.1397-1403
    • /
    • 2011
  • In this paper, fabrication of sample holder was studied for an analysis of electromagnetic(EM) wave property in W-band(75 GHz~110 GHz). First of all, a propagation theory of EM wave was considered in the rectangular waveguide, and measurement technique was suggested for analysis of characteristics. A sample holder using in W-band was designed and fabricated, and used for analysis of material property and absorption ability using RAM samples. As a result, the sample holder test was verified exactly for measuring EM wave property of RAM sample. In the future, the proposed sample holder would like to be used for the EM wave property analysis in W-band.

Design of Educational Application for Writing and Apparatus(Holder) for Correct Holding Angle of a Touch pen (쓰기 학습용 애플리케이션과 터치펜을 바르게 잡기 위한 홀더 설계)

  • Kim, Jimin
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2016.01a
    • /
    • pp.337-340
    • /
    • 2016
  • 본 논문은 유아 및 저학년 초등학생의 쓰기 학습을 위한 쓰기 학습용 애플리케이션을 설계하였다. 유아들은 어린 나이에 수동적인 글쓰기를 시작하고 전통적으로 사용된 '정사각형 글씨 교본'의 정형화된 연습으로 학습에 흥미를 잃는다. 쓰기 학습용 애플리케이션은 전통적 글씨 연습의 틀에서 벗어나, 게임 형태의 콘텐츠로 재미를 유지하도록 메인화면, 메뉴, 실행 화면 등의 내용을 기술하였고 설계하였다. 그리고 유아들은 수동적인 글쓰기로 인해 올바르지 못한 쓰기 자세를 형성한다. 이는 어린 아이들의 손에 무리가 가게 된다. 학생용 애플리케이션과 함께 설계한 홀더는 손에 힘이 없는 아이들이 쉽고 편안하게 필기구를 잡는 습관을 기르기 위한 것으로 지렛대 메커니즘을 응용하였다. 다양한 손의 크기에 대응하여 조절할 수 있도록 중지 받침대 조절 기능으로 다양한 연령대가 사용할 수 있다. 학습용 게임 애플리케이션의 재미와 홀더의 효과 등의 내용을 기술하였고 모바일에서 또 다른 아이들의 쓰기 방법을 제안한다.

  • PDF

Study on the Development of Wet Cell Holder for the Measurement of Hydrophilic Contact Lens (친수성 콘택트렌즈 측정용 Wet Cell 홀더 개발에 관한 연구)

  • Song, Kyoung-Sek;Lim, Hyeon-Sun;Joo, Seok-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.455-462
    • /
    • 2015
  • Purpose: To develop more accurate wet measuring system combining the wet cell, automatic lensmeter and the related software for hydrophilic contact lenses and to verify the accuracy of those measuring holder system already available in the market. Methods: Refractive power measurement were done in both a conventional method which has been commonly used in optical shops and a new method which is recently developed in korea. Hydrophilic contact lens of korean brand was chosen as a test material and was tested by water content ratio and by spherical refractive power. Results: When spherical power of -3.00 D contact lens is measured in the newly developed wet cell measurement holder with automatic lensmeter, it reads -3.01 D at water content ratio of 38%. -3.00 D at 45% and -2.98 D at 58%. The same experiment with the Poster soft contact lens wet cell measurement holder maintaining other conditions same resulted in -3.60 D at the water content ratio of 38%, -3.06 D at 45% and -2.46 D at 58%. Conclusions: At the higher water content, the refractive power values measured by both of the wet cell measuring holders are shown lower, and additionally, the new method using the wet cell holder and new software program in a automatic lensmeter showed more accurate readings than conventional Poster soft contact lens wet cell measuring system.