• Title/Summary/Keyword: 혼합센서

Search Result 347, Processing Time 0.028 seconds

An Indirect Localization Scheme for Low- Density Sensor Nodes in Wireless Sensor Networks (무선 센서 네트워크에서 저밀도 센서 노드에 대한 간접 위치 추정 알고리즘)

  • Jung, Young-Seok;Wu, Mary;Kim, Chong-Gun
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.1
    • /
    • pp.32-38
    • /
    • 2012
  • Each sensor node can know its location in several ways, if the node process the information based on its geographical position in sensor networks. In the localization scheme using GPS, there could be nodes that don't know their locations because the scheme requires line of sight to radio wave. Moreover, this scheme is high costly and consumes a lot of power. The localization scheme without GPS uses a sophisticated mathematical algorithm estimating location of sensor nodes that may be inaccurate. AHLoS(Ad Hoc Localization System) is a hybrid scheme using both GPS and location estimation algorithm. In AHLoS, the GPS node, which can receive its location from GPS, broadcasts its location to adjacent normal nodes which are not GPS devices. Normal nodes can estimate their location by using iterative triangulation algorithms if they receive at least three beacons which contain the position informations of neighbor nodes. But, there are some cases that a normal node receives less than two beacons by geographical conditions, network density, movements of nodes in sensor networks. We propose an indirect localization scheme for low-density sensor nodes which are difficult to receive directly at least three beacons from GPS nodes in wireless network.

Manufacturing Method for Sensor-Structure Integrated Composite Structure (센서-구조 일체형 복합재료 구조물 제작 방법)

  • Han, Dae-Hyun;Kang, Lae-Hyong;Thayer, Jordan;Farrar, Charles
    • Composites Research
    • /
    • v.28 no.4
    • /
    • pp.155-161
    • /
    • 2015
  • A composite structure was fabricated with embedded impact detection capabilities for applications in Structural Health Monitoring (SHM). By embedding sensor functionality in the composite, the structure can successfully perform impact localization in real time. Smart resin, composed of $Pb(Ni_{1/3}Nb_{2/3})O_3-Pb(Zr,\;Ti)O_2$ (PNN-PZT) powder and epoxy resin with 1:30 wt%, was used instead of conventional epoxy resin in order to activate the sensor function in the composite structure. The embedded impact sensor in the composite was fabricated using Hand Lay-up and Vacuum Assisted Resin Transfer Molding(VARTM) methods to inject the smart resin into the glass-fiber fabric. The electrodes were fabricated using silver paste on both the upper and bottom sides of the specimen, then poling treatment was conducted to activate the sensor function using a high voltage amplifier at 4 kV/mm for 30 min at room temperature. The composite's piezoelectric sensitivity was measured to be 35.13 mV/N by comparing the impact force signals from an impact hammer with the corresponding output voltage from the sensor. Because impact sensor functionality was successfully embedded in the composite structure, various applications of this technique in the SHM industry are anticipated. In particular, impact localization on large-scale composite structures with complex geometries is feasible using this composite embedded impact sensor.

Dynamic Scheduling Method of Wireless Control System in Factory Environment (공장 환경에서의 무선 제언 시스템을 위한 센서네트워크의 동적 스케줄링 기법에 대한 연구)

  • Lee, Jung-Il;Kim, Dong-Sung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.2
    • /
    • pp.45-54
    • /
    • 2008
  • In this paper, a dynamic GTS scheduling method based on IEEE 802.15.4 is proposed for wireless control system. The proposed method can guarantee a transmission of real-time periodic and sporadic data within the time frame in factory environment. The modified superframe of IEEE 802.15.4 was used to the dynamic scheduling method of real-time mixed traffic(periodic data, sporadic data, and non real-time message). By separating CFP and CAP properly, the sporadic and non real-time messages are transmitted effectively and guarantee real-time transmission within a deadline. The simulation results show the improvement of real-time performance of periodic and sporadic data.

Power-Aware Scheduling for Mixed Real-Time Tasks (주기성과 산발성 태스크가 혼합된 시스템을 위한 전력절감 스케줄링 기법)

  • Gong, Min-Sik;Jeong, Gun-Jae;Song, Ye-Jin;Jung, Myoung-Jo;Cho, Moon-Haeng;Lee, Cheol-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.1
    • /
    • pp.83-93
    • /
    • 2007
  • In this paper, we address a power-aware scheduling algorithm for a mixed real-time system which consists of periodic and sporadic tasks, each of which is characterized by its minimum period, worst-case execution requirement and deadline. We propose a dynamic voltage scaling algorithm called DVSMT(DVS for mixed tasks), which dynamically scales down the supplying voltage(and thus the frequency) using on-line distribution of the borrowed resources when jobs complete while still meeting their deadlines. With this scheme, we could reduce more energy consumption. As the proposed algorithm can be easily incorporated with RTOS(Real-Time Operating System), it is applicable for handhold devices and sensor network nodes that use a limited battery power. Simulation results show that DVSMT saves up 60% more than the existing algorithms both in the periodic-task and mixed-task systems.

Study of Enzyme Immobilization on Composite of CTA and PCL Membrane for Biosensor (바이오센서용 CTA와 PCL 혼합막에의 효소고정화 기법의 개발)

  • 홍성현;김태진
    • KSBB Journal
    • /
    • v.10 no.4
    • /
    • pp.468-474
    • /
    • 1995
  • The disposable glucose bio-sensor using composite of CTA and PCL membrane was developed for measurement of glucose. The most effective membrane was composed of CTA/PCL(80/20, w/w) and glutaraldehyde one-step immobilization method ($10{\mu}m$ thickness) for glucose sensor gave the best result among various methods, considering oxygen permeability and electronic sensitivity. A scanning electron micrograph of the cross-section of a typical asymmetric CTA/PCL composite membrane showed that the membrane fused with a dense layer covered with a GOD-glutaraldehyde. Glucose oxidase immoblilized on the membrane showed the linearity between difference of absolute amperometric values and glucose concentrations within 7mM when the GOD immobilized electrode was used. About 35% of activity was remained after 8 days when the tyrosinase was immobilized on CTA/PCL (80/20) membrane.

  • PDF

Conditional fuzzy cluster filter for color image enhancement under the mixed color noise (혼합된 칼라 잡음하에서 칼라 영상 향상을 위한 조건적인 퍼지 클러스터 필터)

  • Eum, Kyoung-Bae;Han, Seo-Won;Lee, Joon-Whoan
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.12
    • /
    • pp.3718-3726
    • /
    • 1999
  • Color image is more effective than gray one in human visual perception. Therefore, color image processing becomes important area. Color images are often corrupted by noises due to the input sensor, channel transmission errors and so on. Some filtering techniques such as vector median, mean filter, and vector $\alpha-trimmed$ mean filter have been used for color noise removal. Among them, vector $\alpha-trimmed$ mean filter gave the best performance in the mixed color noise. But, there are edge shift and blurring effect because vector $\alpha-trimmed$ mean filter is uniformly processed across the image. So, we proposed a conditional fuzzy cluster filter to improve this problems. Simulation results showed that the proposed scheme improves the NCD measure and visual quality over the conventional vector $\alpha-trimmed$ mean filter in the mixed color noise.

  • PDF

Experimental study for the development of hydrophone-based bedload discharge estimation algorithm (하이드로폰 기반 소류사량 추정 알고리즘 개발을 위한 실험적 연구)

  • Choi, jong ho;Jun, kye won;Jang, chang duk;Kim, hyeon gyu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.225-225
    • /
    • 2020
  • 최근 국내·외에서는 재래식 소류사량 채집기를 이용한 직접계측방법의 한계를 보완하기 위해 음향센서(하이드로폰)를 활용하여 소류사가 이동할 때 발생하는 충돌음 신호로부터 소류사량을 간접적으로 추정하는 방법이 개발 검토되고 있다. 이러한 방법은 하이드로폰에 계측된 음향신호의 특성 중 음향 펄스 수와 소류사량의 상관성을 해명하는 연구가 주를 이루고 있다. 그러나 기존의 펄스 카운트 알고리즘은 원시신호에 대한 불충분한 노이즈 필터링 작업과 음향특성 중 진폭만을 고려하여 임계치를 설정하였기 때문에 운송되는 소류사량이 많을 경우 신호 파형의 중첩으로 인한 펄스 수의 과소평가, 감지 가능한 상한 입자 크기가 제한되는 등의 결점을 가지고 있다. 또한 대다수의 연구가 소류사량의 총량과 시계열적인 변화를 추정하는데 주안점을 두고 있어 소류사량의 입도분포를 추정하기 위한 연구사례는 매우 부족한 실정에 있다. 따라서 본 연구에서는 위와 같은 한계를 극복하기 위해 다양한 입경과 유속 조건을 고려한 단독입자 공급 실험을 통해 하이드로폰에서 계측되는 소류사 입경별 충돌음의 진폭과 특정 주파수대역을 기준으로 음향특성치를 효과적으로 필터링 할 수 있는 개선된 Band-Passs Method 방법을 제안하였다. 제안된 방법의 검증을 위해 기존의 음향신호 필터링 방법(증폭 채널 방법, 임계치 설정 방법)과 비교·분석을 수행한 결과 제안한 방법이 기존의 필터링 방법보다 높은 소류사량 추정률을 보이는 것으로 나타났다. 아울러 단일입경 연속공급 실험을 수행하여 입경별 소류사량 추정관계식을 산출하고 혼합입경의 입도분포 추정 가능성을 확인하였다. 연구수행의 최종단계로 혼합입경 소류사량 추정이 가능한 입경별 통합 소류사량 추정 알고리즘을 개발하고 실측 소류사량과의 비교·분석을 통해 알고리즘의 소류사량 추정 정밀도를 검증하였다.

  • PDF

Fabrication and Gas Sensing Properties of WO$_3$Thick Film Gas Sensor Dependent on Heat-Treatment Condition (소성 조건에 따른 WO$_3$계 후막센서소자의 제조 및 응답특성)

  • 정용근;엄우식;이희수;최성철
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.6 no.2
    • /
    • pp.63-68
    • /
    • 1999
  • We have fabricated $WO_3$ thick film gas sensor under various firing conditions in order to study gas sensing properties in terms of the variation of microstructure and non-stoichiometric structure of gas sensing layer. $WO_3$ paste mixed homogeneously with organic vehicle was coated by screen printing method on alumina substrate composed of Au electrode and $RuO_2$heater on each side. To change filing condition, sensing materials were fared at 600-$800^{\circ}C$ for 1 hour and refired at $700^{\circ}C$ for 1 hour in the mixtures of $_Ar/O2$gas. In the result of heat-treatment, $WO_3$ gas sensor fared at $700^{\circ}C$ showed best gas sensing properties of 210 gas sensitivity and 2 second response time and the best firing environment was 40-50% of $Ar/O_2$gas.

  • PDF

$Co_{3}O_{4}$ butane gas sensor operating at low temperature (I) (저온동작용 $Co_{3}O_{4}$ 부탄가스 감지 소자(I))

  • Chung, Jin-Hwan;Choi, Soon-Don
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.6
    • /
    • pp.7-14
    • /
    • 1996
  • In order to develop gas sensor operating at low temperature, thick film $Co_{3}O_{4}$ sensor was fabricated. $Co_{3}O_{4}$ powder was prepared by precipitation from cobalt nitrate solution and the powders containing ethylene glycol as a binder was screen-printed on alumina substrate. Characteristics of sensitivity, response time, and recovery were investigated in terms of binder content and heat treating conditions. The $Co_{3}O_{4}$ sensor contained 15% ethylene glycol and heat-treated at $300^{\circ}C$ for 24hr showed the highest sensitivity at the operating temperature of $250^{\circ}C$. Its sensitivity of 1.1 to 5000ppm butane gas was very high, as compared with $0.8{\sim}0.85$ at the operating temperature of $350{\sim}400^{\circ}C$ for a commercial $SnO_{2}$ gas sensor. It is found that response time was fast, but recovery was poor for the sensor.

  • PDF

Development and Characterization of Optical Dissolved Oxygen Sensor based on the Fluorescence Detection (형광검출기반 광학식 용존산소 측정센서 개발 및 특성 분석)

  • Kwak, Hyun Min;Kwon, Myeunghoi;Choi, Gyewoon;Jung, Yoonseok;Jung, Changhwan;Park, Kiuha;Sohn, Okjae;Kim, Junhyong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.569-574
    • /
    • 2014
  • We developed and evaluated a fluorescence-based optical DO sensor (OS-100, Global Optical Communication Ltd., Korea) for long-term monitoring of the dissolved oxygen concentration in waste water treatment. Fluorescent sensing membrane containing $Ru(Dpp)_3{^{2+}}$ (tris(4,7diphenyl-1, 10-phenanthroline) ruthenium(II)) was prepared with GA sol-gel matrix and coated on a quartz plate by sprayed method. Properties of sensor film exhibit deviation about ${\pm}1%$ under wide range of DO concentration from 3 to 10. The developed optical DO sensor was actually mounted in waste water from dyeing industry and successfully applied for on-line DO monitoring. Online monitoring results showed the changes of DO concentrations in wastewater treatment processes with accuracy better than ${\pm}2%$ during the 6 months measurements period in vicious environmental conditions.