• Title/Summary/Keyword: 혼합기체

Search Result 619, Processing Time 0.03 seconds

Separation characteristics of separation devices using inlet water mixed with exhalation gases without a compressor (날숨이 혼합된 물을 사용한 압축기없는 용존기체 분리기의 분리 특성)

  • Heo, Pil Woo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.9
    • /
    • pp.842-846
    • /
    • 2016
  • It's possible for a human to breathe under water, but the amount of dissolved oxygen in the water is small and a large amount of water is necessary to obtain sufficient dissolved oxygen from water. So, large separation system with large water pumps, having large surface areas, and large battery sources are needed. Exhalation gases are used to solve this problem. Theses gases contain some oxygen, nitrogen, and carbon dioxide; they contain less oxygen and more carbon dioxide compared to air. Therefore, reduction of the amount of carbon dioxide is necessary. If exhalation gases are employed appropriately, the separation device can be made more compact. Inlet water mixed with exhalation gases is supplied into the separation device, and dissolved gases are separated from the mixed water as it passes through the device. The inlet part of a typical separation system with a water delivery pump before the membrane module has more than one atmosphere. Hence, a compressor is used to mix the exhalation gases. In this study, the pressure at the inlet due to the use of a suction pump after the membrane module was less than one atmosphere; hence, compressors were not required. Separation characteristics were studied using a separation device without a compressor. The use of exhalation gases led to an increase in the amount of dissolved gases being separated. As the amount of inlet exhalation gases was increased, the separation of dissolved gases was increased as well.

Enhancement of Gas Transfer Efficiency in an Intravascular Lung Assist Device using Blood Substitutes (혈관내의 폐보조장치에서 혈액대용물질을 사용한 기체전달 효율향상)

  • 김기범;박재관;권대규;정경락;이삼철
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.391-399
    • /
    • 2003
  • Intravascular oxygenation represents an attractive. alternative support modality for therapy originated with acute respiratory distress syndrome(ARDS). However. the clinical study concluded that more gas exchange was needed for intravascular oxygenation to be clinically effective in ARDS treatment. In this study, we tried to enhance gas exchange on the VIVLAD using microencapsulation of hemoglobin and perfluorocarbon emulsion(PFC emulsion). Blood gas measurements were performed by collecting blood samples from the arterial and venous sides of the circuit, and processing them in a blood/gas analyzer. The function of hemosome. blood/hemosome mixed solution. and blood/PFC emulsion mixed solution were tested by an oxygen dissociation curve using a blood/gas analyzer. As a result, it was shown that the oxygen transfer of hemosome and blood/hemosome mixed solution were higher than that of whole blood. Also. it showed that the carbon dioxide transfer of whole blood/PFC emulsion mixed solution was higher than that of others. Therefore, we determined that hemosome and PFC emulsion could increase oxygen transfer and carbon dioxide transfer. respectively.

QMS를 이용한 반도체 공정용 혼합 기체 조성비의 정량적 측정 기술

  • Min, Gwan-Sik;Cha, Deok-Jun;Yun, Ju-Yeong;Gang, Sang-U;Sin, Yong-Hyeon;Yun, Seok-Rae;Park, Won-Yeong;Lee, Gyu-Chan;Kim, Jin-Tae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.236-236
    • /
    • 2012
  • QMS(Quadruple Mass Spectrometer)를 사용하여 혼합 기체의 조성비를 측정하는 기술로 He, $NF_3$, $CF_4$, $SF_6$가 포함된 공정에서 사용되는 가스를 사용하여 실제 조성비를 정량적으로 구하는 방법을 연구하였다. 실험을 위해 압력을 $1{\times}10^{-8}Torr$로 배기하였고, 반복 실험을 통하여 최적의 값으로 QMS를 튜닝을 한 후 He, $NF_3$, $CF_4$, $SF_6$가스에 대한 감도를 구하였다. 측정된 감도 값을 바탕으로 총 10회의 반복 측정한 데이터를 이용하여 농도 값을 얻었다. 사용된 가스는 한국표준과학연구원 표준가스실에 제작한 가스이다. 실험 데이터를 이용한 농도와 실제 농도를 비교한 결과 5% 이내의 오차 범위에서 농도 측정이 가능했다.

  • PDF

Shock Tube and Modeling Study of Ignition in$NH_3-NO-Ar$Mixtures ($NH_3-NO-Ar$혼합기체의 점화 과정에 관한 충격관 실험 및 모델 연규)

  • Shin, Kuan Soo;Bae, Gyun Tack;Shim, Seung Bo;Ryu, Si Ok
    • Journal of the Korean Chemical Society
    • /
    • v.45 no.2
    • /
    • pp.111-115
    • /
    • 2001
  • The ignition of NH$_3$-NO-Ar mixtures was examined in the temperature renge of 1675-2391 K behind reflected shock waves. The ignition delay times were measured by monitoring pressure profiles and the OH emissions at 1.0 cm from the end wall. A correlation between ignition delay times and concentrations of gases could be summarized in the form of mass-action expression, To complement the experiment, computer modeling study of the ignition of NH$_3$-NO-Ar mixtures was carried out using various mechanisms reported previously. The sensitivity analysis shows the reaction of NH$_2$+NO${\rightarrow}$NNH+OH is the most important step in the ignition of NH$_3$-NO-Ar mixtures.

  • PDF

Gas Permeation Characteristics by Pebax/ZIF-9 Mixed Matrix Membrane (Pebax/ZIF-9 혼합막에 의한 기체투과 특성)

  • Yoon, Soong Seok;Hong, Se Ryeong
    • Membrane Journal
    • /
    • v.32 no.5
    • /
    • pp.325-335
    • /
    • 2022
  • In this study, zeolitic imidazolate framework-9 (ZIF-9) was synthesized and Pebax/ZIF-9 mixed membranes were prepared by varying the content in poly(ether-b-amide)-1657 (Pebax-1657), and then a single gas (N2, CO2) was permeated to investigate the gas permeation characteristics of the mixed membrane. As the ZIF-9 content incorporated into the pure Pebax membrane increased, the N2 permeability gradually decreased, and the CO2 permeability increased up to the Pebax/ZIF-9 3 wt% mixed membrane, and then decreased at the content thereafter. And among the mixed membranes, the Pebax/ZIF-9 3 wt% mixed membrane showed the highest selectivity of 69.3 by selectively accepting CO2 as the gate-opening phenomenon occurred for the polar gas, CO2. In addition, both the CO2 permeability and the CO2/N2 selectivity increased, resulting in the closest Robeson upper-bound.

Gas Permeation Characteristics of Water-Casting Composite Membrane (수면전개 복합막의 기체투과 특성에 관한 연구)

  • Nam, Suk-Tae
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1992.10a
    • /
    • pp.49-52
    • /
    • 1992
  • 본 연구에서는 기체분리용 고분자 분리막을 박막화하기 위하여 기체의 선택도와 투과도가 서로 상이한 celluloseacetate(CA), polyvinylchloride(PVC) 및 polystyrene(PS) 등의 고분자용액을 사용하여 수면전개법에 수면 전개기구와 박막의 구조적 특성을 연구하였고, 또한 기체 분리막으로서의 이 수면전개막을 개발하기 위하여 CA, PVC, PS 단일 적층막, CA-PVC 복합적 층막, PVC/PS 혼합적층막의 형태로 제막하여 기체분리효과를 검토하였다.

  • PDF

Low Temperature Growth of MCN(M=Ti, Hf) Coating Layers by Plasma Enhanced MOCVD and Study on Their Characteristics (플라즈마 보조 유기금속 화학기상 증착법에 의한 MCN(M=Ti, Hf) 코팅막의 저온성장과 그들의 특성연구)

  • Boo, Jin-Hyo;Heo, Cheol-Ho;Cho, Yong-Ki;Yoon, Joo-Sun;Han, Jeon-G.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.6
    • /
    • pp.563-575
    • /
    • 2006
  • Ti(C,N) films are synthesized by pulsed DC plasma enhanced chemical vapor deposition (PEMOCVD) using metal-organic compounds of tetrakis diethylamide titanium at $200-300^{\circ}C$. To compare plasma parameter, in this study, $H_2$ and $He/H_2$ gases are used as carrier gas. The effect of $N_2\;and\;NH_3$ gases as reactive gas is also evaluated in reduction of C content of the films. Radical formation and ionization behaviors in plasma are analyzed in-situ by optical emission spectroscopy (OES) at various pulsed bias voltages and gas species. He and $H_2$ mixture is very effective in enhancing ionization of radicals, especially for the $N_2$. Ammonia $(NH_3)$ gas also highly reduces the formation of CN radical, thereby decreasing C content of Ti(C, N) films in a great deal. The microhardness of film is obtained to be $1,250\;Hk_{0.01}\;to\;1,760\;Hk_{0.01}$ depending on gas species and bias voltage. Higher hardness can be obtained under the conditions of $H_2\;and\;N_2$ gases as well as bias voltage of 600 V. Hf(C, N) films were also obtained by pulsed DC PEMOCYB from tetrakis diethyl-amide hafnium and $N_2/He-H_2$ mixture. The depositions were carried out at temperature of below $300^{\circ}C$, total chamber pressure of 1 Torr and varying the deposition parameters. Influences of the nitrogen contents in the plasma decreased the growth rate and attributed to amorphous components, to the high carbon content of the film. In XRD analysis the domain lattice plain was (111) direction and the maximum microhardness was observed to be $2,460\;Hk_{0.025}$ for a Hf(C,N) film grown under -600 V and 0.1 flow rate of nitrogen. The optical emission spectra measured during PEMOCVD processes of Hf(C, N) film growth were also discussed. $N_2,\;N_2^+$, H, He, CH, CN radicals and metal species(Hf) were detected and CH, CN radicals that make an important role of total PEMOCVD process increased carbon content.

Measuring CO Concentration in a Flame with Broadband CARS (광대역 CARS를 이용한 불꽃 내부의 CO 농도 측정)

  • 한재원
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.2
    • /
    • pp.212-219
    • /
    • 1993
  • To reduce the mode noise induced from a multimode dye laser, a modeless laser generating amplified spontaneous emission was used as Stokes beam of the broadband CARS. A new technique for measuring species concentration from the modulation dip of nonresonant background of broadband CARS spectrum was proposed. The modulation dip was numerically calculated and fitted as a function of the concentration of the minor species and temperature of gas sample. We applied this technique in measuring CO concentration in a static cell and also the profile of CO concentration in a CHdair premixed flame of a counterflow burner.

  • PDF

Enrichment of Oxygen and process engineering aspects using polysulfone hollowfiber membrane (폴리수폰 중공사막에 의한 산소농축 및 공정변수의 영향)

  • 조정식;김종수;이광래
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.10a
    • /
    • pp.65-66
    • /
    • 1997
  • 1. 서론 : 현재의 막분리 기술로는 단 단계 분리공정(single-stage separation)으로 약 40%의 산소농축공기(oxygen-enriched air)를 얻을 수 밖에 없지만 심냉법(cryogenic techniques)보다는 에너지 소비율이 적으며, 공정이 비교적 간단하기 때문에 용도에 따라 순 산소를 꼭 필요로 하지 않는 제철소, 발전소 등의 연소분야, 호흡기 환자를 위한 의료분야, 생물공학이나 항공기 분야 등에 편리하게 이용될 수 있다. 이와 같이 용도가 다양한 산소를 분리막을 이용하여 보다 편리하고 값싸게 얻기 위해서는 산소와 질소의 막투과에 대한 새로운 지식을 얻고 막투과가 기체의 어떤 성질에 지배되고 있는가를 조사할 필요가 있다. 본 연구에서는 고무상 고분자막(rubbery polymer membrane)에 대한 산소/질소의 수착특성과 순수한 기체의 투과율(permeation rate)을 기초로 하여 혼합기체의 투과율, 분리인자(separation factor), 막분리 공정변수에 의한 중공사 분리막에서의 기체분리특성에 대하여 연구하였다.

  • PDF

광방사 세기비를 이용한 공정 플라즈마의 변수 진단

  • Lee, Yeong-Gwang;O, Se-Jin;Lee, Jae-Won;Hwang, Hye-Ju;Lee, Hui-Jin;Kim, Yu-Sin;Jeong, Jin-Uk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.149-149
    • /
    • 2011
  • 아르곤 기체의 방사세기 또는 그 세기 비는 플라즈마 공정 진단에서 일반적으로 사용된다. 본 실험에서는 100 mTorr 압력 조건하의 유도결합 플라즈마(13.56 MHz)에서 E-H 모드 전이 영역, rf 바이어스(12.5 MHz) 전력 인가 및 N2 혼합 시 단순화한 충돌-방사 모델에 기초한 광방사 세기비 방법을 적용하여 플라즈마 변수를 진단하였다. 개발 프로그램 기반의 분광기를 사용하여 아르곤 기체의 특정 파장(750.4, 751.5 그리고 811.5 nm)들을 관측하였고, 동일한 조건하에서 정전 탐침법으을 이용하여 전자 에너지 분포함수의 변화도 측정 하였다. 맥스웰 전자 에너지 분포를 가정하는 일반적인 경우와 비교하여 볼 때 실제적인 전자 에너지 분포함수의 측정은 전자의 가열 메커니즘에 대한 상세한 정보를 제공함과 동시에 플라즈마 재흡수에 대한 보정을 가능하게 해준다. 광방사 세기비법에 의해 측정된 결과에 의하면, 750.4 nm/751.5 nm는 높은 에너지(>13.08 eV)의 전자들의 유효 전자온도에 대한 정보를 나타내는 반면 811.5 nm/750.4 nm는 아르곤 준안정 준위 밀도(1s5)에 대한 정보를 제공하게 된다. 수행된 실험 조건하에서, 측정된 준안정 준위 밀도는 E-H 모드 전이 영역에서 최대값을 나타내었고 바이어스 전압 및 N2 기체 혼합 비율이 증가함에 따라 감소하는 결과를 얻었다. 유효 전자온도의 경우 광방사 세기비법과 정전 탐침법 모두 같은 결과를 보여 주었는데, E-H 모드 전이 영역에서는 전자온도는 거의 일정하였고 바이어스 전압 및 N2 기체 혼합 비율이 증가함에 따라 전자온도는 증가하였다. 이러한 실험 결과는 방전 모드 전이, 바이어스 인가 그리고 혼합 기체 사용하는 공정 플라즈마를 이해하는데 있어 이들 변수의 진단이 중요한 요소임을 보여준다.

  • PDF