• Title/Summary/Keyword: 혈관 수축

Search Result 361, Processing Time 0.025 seconds

Effect of Magnesium on the Contractility of the Isolated Guinea-Pig Aortic and Rat Smooth Muscles (마그네슘이온이 적출한 기니피그 대동맥평활근과 흰쥐 자궁평활근의 수축성에 미치는 효과에 관한 연구)

  • Ahn, Hyuk;Hwang, Sang-Ik
    • Journal of Chest Surgery
    • /
    • v.23 no.3
    • /
    • pp.452-464
    • /
    • 1990
  • It is well known that extracellular Calcium plays a very important role in several steps of smooth muscle excitability and contractility, and there have been many concerns about factors influencing the distribution of extracellular Ca++ and the Ca++ flux through the cell membrane of the smooth muscle. Based on the assumption that Mg++ may also play an important role in the excitation and contraction processes of the smooth muscle by taking part in affecting Ca++ distribution and flux, many researches are being performed about the exact role of Mg++, especially in the vascular smooth muscle. But yet the effect of Mg++ in the smooth muscle activity is not clarified, and moreover the mechanism of Mg++ action is almost completely unknown. Present study attempted to clarify the effect of Mg++ on the excitability and contractility in the multiunit and unitary smooth muscle, and the mechanism concerned in it. The preparations used were the guinea-pig aortic strip as the experimental material of the multiunit smooth muscle and the rat uterine strip as the one of the unitary smooth muscle. The tissues were isolated from the sacrificed animal and were prepared for recording the isometric contraction. The effects of Mg++ and Ca++ were examined on the electrically driven or spontaneous contraction of the preparations. And the effects of these ions were also studied on the K+ or norepinephrine contracture. All experiments were performed in tris-buffered Tyrode solution which was aerated with 100% 02 and kept at 35oC. The results obtained were as follows: 1] Mg++ suppressed the phasic contraction induced by electrical field stimulation dose-dependently in the guinea-pig aortic strip, while the high concentration of Ca++ never recovered the decreased tension. These phenomena were not changed by the a - or b - adrenergic blocker. 2]Mg++ played the suppressing effect on the low concentration [20 and 40 mM] of K+-contracture in the aortic muscle, but the effect was not shown in the case of 100mM K+-contracture. 3] Mg++ also suppressed the contracture induced by norepinephrine in the aortic preparation. And the effect of Mg++ was most prominent in the contracture by the lowest [10 mM] concentration of norepinephrine. 4] In both the spontaneous and electrically driven contractions of the uterine strip, Mg++ decreased the amplitude of peak tension, and by the high concentration of Ca++ the amplitude of tension was recovered unlike the aortic muscle. 5] The frequency of the uterine spontaneous contraction increased as the [Ca++] / [Mg++] ratio increased up to 2, but the frequency decreased above this level. 6] Mg++ decreased the tension of the low[20 and 40mM] K+-contracture in the uterine smooth muscle, but the effect did not appear in the 100mM K+-contracture. From the above results, the following conclusion could be made. 1] Mg++ seems to suppress the contractility directly by acting on the smooth muscle itself, besides through the indirect action on the nerve terminal, in both the aortic and uterine smooth muscles. 2] The fact that the depressant effect of Mg++ on the K+-contracture is in inverse proportion to an increase of K+ concentration appears resulted from the extent of the opening state of the Ca++ channel. 3] Mg++ may play a depressant role on both the potential dependent and the receptor-operated Ca++ channels. 4] The relationship between the actions of Mg++ and Ca++ seems to be competitive in uterine muscle and non-competitive in aortic strip.

  • PDF

Effect of Sternal Closure Method on Sternal Dehiscence With or Without Infection (흉골 봉합 방법이 흉골 열개 및 감염에 미치는 영향)

  • 이삼윤;박권재;고광표;최종범
    • Journal of Chest Surgery
    • /
    • v.34 no.6
    • /
    • pp.485-489
    • /
    • 2001
  • Background: The most important factor in preventing sternal complications is stable sternal approximation. We have tried to find the most effective sternal closure method by examining the incidence of sternal dehiscence with or without infection in patients with cardiac surgery through median sternotomy. Material and Method: This study was performed in 489 patients over 45 years of age with median sternotomy for open cardiac surgery. Simple closure with interrupted 6 wires was performed in 159 patients, figure-of-8 closure technique in 119, overlapping interrupted closure using 10 wires in 150, and combined closure technique of interrupted simple closure and figure-of-8 suture closure in 61. Two hundred thirty-four patients underwent valve and aortic operations and 213 patients coronary artery bypass surgery. Result: Sternal dehiscence with or without infection occurred in 12 (2.5 %) patients. The complication developed in 5 of 159 patients (3.1%) with six interrupted simple closure, in 4 of 119 patients (3.4%) with figure-of-8 closure, and in 3 of 150 patients (2.0%) with overlapping interrupted closure using 10 wires, but there was no complication in 61 patients with combined closure technique (relative risk for other closure techniques, p<0.05). There was no significant difference in the incidence of the sternal complication between valve and aortic operation group and coronary artery bypass group (3.0% vs 2.3%, not significant), but diabetes mellitus was a significant independent risk factor (odds ratio and multivariate analysis, p<0.05). Conclusion: The sternal closure technique that combines simple interrupted suture closure and figure-of-8 suture closure may be a more useful technique to enhance sternal stabilization compared to other closure techniques, such as simple interrupted closure, 8-figure closure, and overlapping interrupted closure.

  • PDF

Survival and Problems after Repair of Tetralogy of Fallot (Fallot 4징 교정수술후의 생존 및 문제점)

  • 손세정;한재진;이영탁;김성호
    • Journal of Chest Surgery
    • /
    • v.32 no.3
    • /
    • pp.237-248
    • /
    • 1999
  • Background: The late results of repair of tetralogy of Fallot(TOF) are favorable in most patients. Some portion of the patients with tetralogy, however, require reoperation for residual lesions or result in late death. The outcome of patients after tetralogy repair performed during the past 13 years was studied, with an emphasis on postrepair survival and problems including reoperations. Material and Method: A retrospective review of clinical, echocardiographic and catheterization data was performed in 569 of 775 patients with TOF who underwent corrective repair between 1983 and 1995 at Sejong General Hospital, Buchon, Korea. Result: Of 28(4.9%) early deaths(defined as 30 days postrepair), 12 deaths(42.9%) were <1 year of age, with an operative mortality of 15.4%. The surviving 541 patients(age 2.8 months to 43.4 years, median 23 months) have been followed up from 1 month to 12.6 years(median 35 months) postoperatively. Most patients were in good functional class and had normal right ventricular(RV) function. Postrepair results were compared between the transatrial-transpulmonary approach and the conventional right ventriculotomy. The former technique provided a lesser incidence of significant pulmonary regurgitation(P<0.001) and alesser degree of RV dysfunction(P<0.05) compared with those in the latter. There were 10(1.8%) late deaths during the follow-up period and 6 of the deaths were directly related to reoperation or ventricular dysfunction. The 10-year actuarial survival rate was 96.7%. There were 44 reoperations(8.1%) in 39 patients(7.2%), with an operative mortality of 10.3%. The main indications or reoperation included residual ventricular septal defect(VSD) (n=6), pulmonary stenosis(PS) (n=11), VSD with PS(n=17), pulmonary regurgitation(n=7), and tricuspid regurgitation(n=2). The 5- and 10-year freedom from reoperation were 89.4% and 76.1%, respectively. Conclusion: Although the majority of patients with repaired TOF are clinically well, with a high rate of survival, approximately 7% of patients have residual lesions that require surgical therapy. Therefore, the timely and meticulous corrective repair is mandatory to avoid reoperation, and continued close surveillance is also needed for the early detection of residual problems.

  • PDF

Effect of Modified Ultrafiltration on the Postoperative State after Pediatric Open Heart Surgery. (소아 개심술에 있어서 변형 초여과법(Modified Ultrafiltration)이 술후 상태에 미치는 영향)

  • 방종경;천종록;김규태
    • Journal of Chest Surgery
    • /
    • v.31 no.5
    • /
    • pp.456-465
    • /
    • 1998
  • Cardiopulmonary bypass(CPB) in children is associated with the accumulation of body water after cardiac operation, as a consequence of an inflammatory capillary leak. Following work by Elliott in 1991, modified ultrafiltration(MUF) was introduced after bypass as a means of hemoconcentrating patients and a potential way of removing water from the tissues. We have carried out a prospective randomized study of 20 children undergoing open heart surgery, comparing MUF with nonfiltered controls. MUF was carried out for a mean of 18.9 minutes after completion of CPB to a hematocrit of 37.1%(mean). The mean water volulme removed by the ultrafiltration was 38.4 ml/kg and the mean blood volume retransfused from the oxygenator during the ultrafiltration was 32.1 ml/kg. Fluid balance, hemodynamics, hematocrit, osmolarity and dosage of drug treatment were recorded for 4∼12 hours postoperatively. The results were analyzed using Student t-test and ANOVA, comparing controls(n=10) to MUF(n=10). Blood loss(ml/kg/24hr) was 14.5(mean) in MUF versus 13.7 in controls; blood transfused(ml/kg/24hr) 6.6 in MUF versus 15.2 in controls; plasma transfused(ml/kg/24hr) 65.7 in MUF versus 59.6 in controls. There was rise in arterial blood pressure and hematocrit during MUF. Percent rise of systolic blood pressure was 28.8% in MUF versus 18.7% in controls(p=0.366); percent rise of diastolic blood pressure was 28.8% in MUF versus 8.5% in controls(p=0.135); and percent rise of mean blood pressure was 36.2% in MUF versus 8.2% in controls (p=0.086). Percent rise of hematocrit was 40.0% in MUF versus 23.5% in controls(p=0.002). There was no significant difference in the inotropic requirement and the postoperative serum osmolarity between two groups. The number of days on the ventilator, the duration of stay in the intensive care unit, and the postoperative hospital stay were not significantly different between the two groups.

  • PDF

A Comparison of the Effects of Histidine-tryptophan-ketoglutarate Solution versus Cold Blood Cardioplegic Solution on Myocardial Protection in Mitral Valve Surgery (승모판막수술 시 히스티딘를 함유한 결정성 심정지액(Histidine-tryptophan-ketoglutarate Solution)과 저온 혈성 심정지액이 심근기능 보존에 미치는 영향 비교)

  • Choi, Yong-Seon;Bang, Sou-Ouk;Chang, Byung-Chul;Lee, Sak;Park, Chol-Hee;Kwak, Young-Lan
    • Journal of Chest Surgery
    • /
    • v.40 no.6 s.275
    • /
    • pp.399-406
    • /
    • 2007
  • Background: Ischemia-reperfusion injury related to unsuccessful myocardial protection affects postoperative ventricular function and mortality during open-heart surgery. We prospectively compared the effects of administration of histidine-tryptophan-ketoglutarate (HTK) solution and cold blood cardioplegia (CBC) on myocardial protection and clinical outcome in patients undergoing mitral valve surgery. Material and Method: Seventy patients with mitral regurgitation (MR) undergoing mitral valve surgery were randomly divided into the HTK group (n=31) and the CBC group (n=31 ): eight patients were excluded. Perioperative hemodynamics, cardiac medications, pacing, postoperative outcomes and complications were recorded during the hospital stay. All patients received follow-up for at least 6 months postoperatively for morbidity and mortality. Resuか: There were no significant differences in the hemodynamics between the groups during the study period, except for the mean pulmonary artery pressure (MPAP), PCWP and CVP that were lower in the HTK group at 15 min after weaning of CBP. There were no differences for inotropic support and pacing during the 12 hrs postoperatively between the groups. CK-MB values on day 1 and day 2 were $77{\pm}54$ and $41{\pm}23$ for the HTK group and $70{\pm}69$ and $44{\pm}34$ for the CBC group, respectively (p=NS). Postoperative clinical outcomes were similar in both groups for at least 6 months during the follow-up period. Conclusion: These results suggest that the use of HTK solution is as safe as cold blood cardioplegia in terms of myocardial protection.

The Comparative Study of on Pump CABG during Pulsatile $(T-PLS^{TM})$ and Nonpulsatile $(Bio-pump^{TM})$ Perfusion (관상동맥우회술 시 사용된 박동성펌프$(T-PLS^{TM})$와 비박동성펌프$(Bio-pump^{TM})$의 비교연구)

  • Park Young-Woo;Her Keun;Lim Jae-Ung;Shin Hwa-Kyun;Won Yong-Soon
    • Journal of Chest Surgery
    • /
    • v.39 no.5 s.262
    • /
    • pp.354-358
    • /
    • 2006
  • Background: Pulsatile pumps for extracorporeal circulation have been known to be better for tissue perfusion than non-pulsatile pumps but be detrimental to blood corpuscles. This study is intended to examine the risks and benefits of $T-PLS^{TM}$ through the comparison of clinical effects of $T-PLS^{TM}$ (pulsatile pump) and $Bio-pump^{TM}$ (non-pulsatile pump) used for coronary bypass surgery. Material and Method: The comparison was made on 40 patients who had coronary bypass using $T-PLS^{TM}\;and\;Bio-pump^{TM}$ (20 patients for each) from April 2003 to June 2005. All of the surgeries were operated on pump beating coronary artery bypass graft using cardiopulmonary extra-corporeal circulation. Risk factors before surgery and the condition during surgery and the results were compared. Result: There was no significant difference in age, gender ratio, and risk factors before surgery such as history of diabetes, hypertension, smoking, obstructive pulmonary disease, coronary infarction, and renal failure between the two groups. Surgery duration, hours of heart-lung machine operation, used shunt and grafted coronary branch were little different between the two groups. The two groups had a similar level of systolic arterial pressure, diastolic arterial pressure and mean arterial pressure, but pulse pressure was measured higher in the group with $T-PLS^{TM}\;(46{\pm}15\;mmHg\;in\;T-PLS^{TM}\;vs\;35{\pm}13\;mmHg\;in\;Bio-pump^{TM},\;p<0.05)$. The $T-PLS^{TM}$-operated patients tended to produce more urine volume during surgery, but the difference was not statistically significant $(9.7{\pm}3.9\;cc/min\;in\;T-PLS^{TM}\;vs\;8.9{\pm}3.6\;cc/min\;in\;Bio-pump^{TM},\;p=0.20)$. There was no significant difference in mean duration of respirator usage and 24-hour blood loss after surgery between the two groups. Plasma free Hb was measured lower in the group with $T-PLS^{TM}\;(24.5{\pm}21.7\;mg/dL\;in\;T-PLS^{TM}\;versus\;46.8{\pm}23.0mg/dL\;in\;Bio-pump^{TM},\;p<0.05)$. There was no significant difference in coronary infarction, arrhythmia, renal failure and morbidity rate of cerebrovascular disease. There was a case of death after surgery (death rate of 5%) in the group tested with $T-PLS^{TM}$, but the death rate was not statistically significant. Conclusion: Coronary bypass was operated with $T-PLS^{TM}$ (Pulsatile flow pump) using a heart-lung machine. There was no unexpected event caused by mechanical error during surgery, and the clinical process of the surgery was the same as the surgery for which $Bio-pump^{TM}$ was used. In addition, $T-PLS^{TM}$ used surgery was found to be less detrimental to blood corpuscles than the pulsatile flow has been known to be. Authors of this study could confirm the safety of $T-PLS^{TM}$.

The Experimental Study for Myocardial Preservation Effect of Ischemic Preconditioning (허혈성 전조건화 유발이 심근보호에 미치는 영향에 관한 실험적 연구)

  • 이종국;박일환;이상헌
    • Journal of Chest Surgery
    • /
    • v.37 no.2
    • /
    • pp.119-130
    • /
    • 2004
  • Decrease in cardiac function after open heart surgery is due to an ischemia induced myocardial damage during surgery, and ischemic preconditioning, a condition in which the myocardial damage does not accumulate after repeated episodes of ischemia but protects itself from damage after prolonged ischemia due to myocytes tolerating the ischemia, is known to diminish myocardial damage, which also helps the recovery of myocardium after reperfusion, and decreases incidences of arrythmia. Our study is performed to display the ischemic preconditioning and show the myocardial protective effect by applying cardioplegic solution to the heart removed from rat. Material and Method: Sprague-Dawley male rats were used, They were fixed on a modified isolated working heart model after cannulation. The reperfusion process was according to non-working and working heart methods and the working method was executed for 20 minutes in which the heart rate, aortic pressure, aortic flow and coronary flow were measured and recorded. The control group is the group which the extracted heart was fixed on the isolated working heart model, recovered by reperfusion 60 minutes after infusion and preserved in the cardioplegic solution 20 minutes after the working heart perfusion and aortic cross clamp, The thesis groups were divided into group I, which ischemic hearts that were hypoxia induced were perfused by cardioplegic solution and preserved for 60 minutes; group II, the cardioplegic solution was infused 45 seconds (II-1), 1 minutes (II-2), 3 minutes (II-3), after the ischemia induction, 20 minutes after working heart perfusion and aortic cross clamp; and group III, hearts were executed on working heart perfusion for 20 minutes and aortic cross clamp was performed for 45 seconds (III-1), 1minute (III-2), 3 minutes (III-3), reperfused for 2 minutes to recover the heart, and then aortic cross clamping was repeated for reperfusion, all the groups were compared based on hemodynamic performance after reperfusion of the heart after preservation for 60 minutes. Result: The recovery time until spontaneous heart beat was longer in groups I, II-3, III-2 and III-3 to control group (p<0.01). Group III-1 (p<0.05) had better results in terms of recovery in number of heart rates compared to control group, and recovered better compared to II-1 (p<0.05). The recovery of aortic blood pressure favored group III-1 (p<0.05) and had better outcomes compared with II-1 (p<0.01). Group III-1 also showed best results in terms of cardiac output (p<0.05) and group III-2 was better compared to II-2 (p<0.05). Group I (p<0.01) and II-3 (p<0.05) showed more cardiac edema than control group. Conclusion: When the effects of other organs are dismissed, protecting the heart by infusion of cardioplegic solution after enforcing ischemia for a short period of time before the onset of abnormal heart beats for preconditioning has a better recovery effect in the cardioplegic group with preconditioning compared to the cardioplegic solution itself. we believe that further study is needed to find a more effective method of preconditioning.

Postoperative Echocardiographic Hemodynamic Comparison between Recently Available Bileaflet Mechanical Valves (수종의 기계판막치환후 초음파심음향도를 이용한 판막간의 혈류역학적 비교)

  • Kang Joon Kyu;Hong Joon Hwa;Kim Hyung Tai;Park In Duk;Lee Cheol Joo
    • Journal of Chest Surgery
    • /
    • v.38 no.7 s.252
    • /
    • pp.496-500
    • /
    • 2005
  • There was no difference between the bileaflet mechanical valves on the midterm and longterm clinical outcome. We reviewed the hemodynamic comparison between recently available mechanical valves by Doppler Echocardiography. Material and Method: We retrospectively reviewed 396 postoperative hemodynamic datas (EOA, MDPG, and MSPG) by doppler echocardiography in 345 patients. Mechanical valves from 5 venders (Sorin Bicarbon, SJM, ATS, On-X, and Edward MIRA) were compared. There were 232 valves in mitral position, 162 in aortic, and 2 in tricuspid. Result: There were 178 men (mean age; $50.6\pm13.9$ years old) and 167 women $(52.6\pm,4.6)$. MDPG/EOA of 27 mm in mitral position was Sorin; $4.2\pm1.5 mmHg/3.0\pm0.9cm^2,\;SJM;\;2.3\pm1.2/3.5\pm0.6$. In 29mm, Sorin, SJM, ATS, On-X, MIRA revealed $3.4\pm1.2/3.1\pm0.6,\;3.3\pm1.1/2.7\pm0.4,\;3.8\pm0.8/3.2\pm0.6,\;4.0\pm3.0/3.1\pm0.9,\;2.9\pm0.9/3.0\pm0.8$ In 31mm, Sorin, SJM, ATS, MIRA revealed $3.9\pm1.9/2.9\pm0.6,\;3.5\pm1.2/3.0\pm0.6,\;3.4\pm0.8/2.8\pm0.2,\;3.7\pm1.5/2.7\pm0.7$. In 33mm, Sorin, SJM, MIRA revealed $4.4\pm0.9/2.5\pm0.4,\;3.4\pm1.5/3.3\pm0.5,\;4.7\pm2.4\3.0\pm0.3$. MSPG/EOA of 19mm aortic position was Sorin, SJM, ATS, On-X, MIRA $18.0 mmHg/1.2cm^2,\;25.6\pm8.7/1.1\pm0.3,\;25.9\pm12.6/1.2\pm0.3,\;23.0/1.3,\;27.9\pm7.1/1.2\pm0.1$ in that order. In 21mm, SJM, ATS, On-X, MIRA revealed $18.3\pm6.7/1.5\pm0.5,\;13.7\pm2.1/1.7\pm0.3,\;17.0/1.4,\;17.1\pm5.5/1.8\pm0.5$. In 23mm Sorin, SJM, ATS, On-X, MIRA revealed $14.0\pm4.6/1.7\pm0.6,\;12.8\pm3.2/2.0\pm0.2,\;16.8\pm12.2/2.1\pm0.9,\;14.0/1.5,\;15.0\pm5.5/1,8\pm0.5$. In 25mm, SJM and MIRA revealed $14.0\pm5.1/1.8\pm1.0,\;11.0/2.3$. There was no statistically significant difference in these values between the venders given the same position and size. 2 redo valve replacements were performed, 1 due to severe hemolysis in ATS and 1 due to leaflet immobilization in SJM. Conclusion: Postoperative hemodynamic comparison by doppler echocardiography shows no statistically significant difference between recently available mechanical valves in this country.

Surgical Treatment of Anomalous Origin of Coronary Artery from the Pulmonary Artery: Postoperative Changes of Ventricular Dimensions and Mitral Regurgitation (관상동맥-폐동맥 이상기시증(Anomalous Origin of Coronary Artery from Pulmonary Artery)의 수술적 치료: 중기 성적과 좌심실 및 승모판 기능의 변화 양상에 대한 연구)

  • Kang, Chang-Hyun;Kim, Woong-Han;Seo, Hong-Joo;Kim, Jae-Hyun;Lee, Cheul;Chang, Yoon-Hee;Hwang, Seong-Wook;Back, Man-Jong;Oh, Sam-Se;Na, Chan-Young;Han, Jae-Jin;Lee, Young-Tak;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.19-26
    • /
    • 2004
  • Background: The aims of this study are to verify the result of the surgical treatment of ALCAPA and to identify the postoperative changes of left ventricular dimensions and mitral regurgitation (MR), Material and Method: Fifteen patients operated on since 1985 were included in the study. The patients operated on before 1998 (n=9) showed heterogeneous properties with various surgical strategies and cardiopulmonary bypass techniques. However, six patients were operated on with the established surgical strategy since 1998; 1) Dual perfusion and dual cardioplegic solution delivery through ascending aorta and main pulmonary artery, 2) Coronary transfer by rolled-conduit made of pulmonary artery wall flap, and 3) Additional mitral valvular procedure was not peformed. Result: Median age of the study group was 6 months (1 month to 34 years). The operative methods were left subclavian artery to left coronary artery anastomosis in 1, simple ligation in 2, Takeuchi operation in 2, and coronary reimplantation in 10 patients. The mean follow up period was 5.5<5.8 years (2 months 14 years), There were one early death (6.7%) and one late death. Overall 5-year survival rate was 85.6$\pm$9.6%. The Z-value of left ventricular end-diastolic and end-systolic dimensions were 6.4$\pm$3.0 and 5.1 $\pm$3.6 preoperatively, and decreased to 1.7$\pm$ 1.9 and 0.8$\pm$ 1.6 in 3 months (p<0.05). Significant preoperative MR was identified in 6 patients (40%) and all the patients showed immediate improvement of MR within f month postoperatively. There were 3 cases of reoperation due to coronary anastomosis site stenosis and recurrence of MR. However, there was no mortality nor late reoperation in the patients operated on after 1998. Conclusion: The surgical treatment of ALCAPA showed favorable survival and early recovery of ventricular dimensions and mitral valvular function. Although long-term reintervention was required in some cases of earlier period, all the cases after 1998 showed excellent surgical outcome without long-term problem.

Usefulness of Pulsatile Flow Aortic Aneurysm Phantoms for Stent-graft Placement (스텐트그라프트 장치술을 위한 대동맥류 혈류 팬텀의 유용성)

  • Kim, Tae-Hyung;Ko, Gi-Young;Song, Ho-Young;Park, In-Kook;Shin, Ji-Hoon;Lim, Jin-Oh;Kim, Jin-Hyoung;Choi, Eu-Gene K.
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.205-212
    • /
    • 2007
  • To evaluate the feasibility and efficacy of a pulsatile aortic aneurysm phantoms for in-vitro study. The phantoms consisted of a pulsating motor part(heart part) and an aortic aneurysm part, which mimicked true physiologic conditions. The heart part was created from a high-pressured water pump and a pulsatile flow solenoid valve for the simulation of aortic flow. The aortic aneurysm part was manufactured from paper clay, which was placed inside a acrylic plastic square box, where liquid silicone was poured. After the silicone was formed, the clay was removed, and a silicone tube was used to connect the heart and aneurysm part. We measured the change in pressure as related to the opening time(pulse rate, Kruskal-Wallis method) and pressure before and after the stent-graft implantation(n = 5, Wilcoxon's signed ranks test). The changes in blood pressures according to pulse rate were all statistically significant(p<0.05). The systolic/diastolic pressures at the proximal aorta, the aortic aneurysm, and the distal aorta of the model were $157.80{\pm}1.92/130.20{\pm}1.92$, $159.40{\pm}1.14/134.00{\pm}2.92$, and $147.20{\pm}1.480/129.60{\pm}2.70\;mmHg$, respectively, when the pulse rate was 0.5 beat/second. The pressures changed to $161.40{\pm}1.34/90.20{\pm}1.64$, $175.00{\pm}1.58/93.00{\pm}1.58$, and $176.80{\pm}1.48/90.80{\pm}1.92\;mmHg$, respectively, when the pulse rate was 1.0 beat/second, and $159.40{\pm}1.82/127.20{\pm}1.48$, $166.60{\pm}1.67/138.00{\pm}1.87$, and $161.00{\pm}1.22/135.40{\pm}1.67\;mmHg$, respectively, when it was 1.5 beat/second. When pulse rate was set at 1.0 beat/second, the pressures were $143.60{\pm}1.67/90.20{\pm}1.64$, $147.20{\pm}1.92/84.60{\pm}1.82$, and $137.40{\pm}1.52/88.80{\pm}1.64\;mmHg$ after stent-graft implantation. The changes of pressure before and after stent-graft implantation were statistically significant(p<0.05) except the diastolic pressures at the proximal(p =1.00) and distal aorta(p=0.157). The aortic aneurysm phantoms seems to be useful for the evaluation of the efficacy of stent-graft before animal or clinical studies because of its easy reproducibility and ability to display a wide range of pressures.

  • PDF