• Title/Summary/Keyword: 혈관 내 성형

Search Result 86, Processing Time 0.01 seconds

Microscopic Decompression of Digital Nerve Surrounded by Hemangioma: A Case Report (미세수술을 통하여 수지신경을 압박하는 혈관종을 성공적으로 제거한 증례 보고)

  • Ko, Jun Gul;Kim, Jun Hyeok;Rha, Eun Young;Lee, Jun Yong;Yoo, Gyeol;Baek, Sang Oon
    • Archives of Hand and Microsurgery
    • /
    • v.23 no.4
    • /
    • pp.301-305
    • /
    • 2018
  • Hemangiomas are benign neoplasms of endothelial cells origin, rarely found in hand region. Authors report a 62-year-old female with capillary hemangioma of right index finger causing a neuropathic symptom via nerve compression. A space-occupying vascular lesion surrounding the radial digital nerve was revealed in magnetic resonance imaging (MRI), which was removed under microscopic assist. The digital nerve was decompressed consequently. The mass was firmly attached to both the digital nerve and digital artery, requiring a meticulous microscopic dissection to preserve the nerve and artery. Compression neuropathy caused by space-occupying lesions is rare and its diagnosis is often difficult. A microscopic surgical approach can be used to successfully relieve neuropathic pain after proper diagnosis established by diagnostic tools such as MRI as in this case.

Classification of Deep Inferior Epigastric Perforator Courses Based on Computed Tomography Angiography: Incidences and Clinical Implications (컴퓨터 단층 촬영 혈관 조영술을 이용한 심하복벽 혈관과 천공지의 박리 용이성에 따른 분류)

  • Lee, Yeonhoon;Kim, Sung Chan;Eom, Jin Sup;Kim, Eun Key
    • Archives of Hand and Microsurgery
    • /
    • v.23 no.4
    • /
    • pp.281-289
    • /
    • 2018
  • Purpose: Preoperative surgical planning utilizing computed tomography angiography (CTA) has now become a routine in many practices. We analyzed the course of the deep inferior epigastric artery (DIEA) and its perforators (DIEP) that would either facilitate or hinder flap dissection based on CTA to aid surgical planning. Methods: The 115 consecutive patients who underwent abdominally based free flap breast reconstruction were enrolled in this prospective study. DIEA/P courses were categorized mainly according to their intramuscular courses and their incidences were investigated. Results: A total of 425 perforators were identified preoperatively on the CTA, with an average number of 3.7 distinctly visualized in the entire flap territory. Eighty-nine perforators (20.9%) had a favorable (less than 1 cm intramuscular course) pattern, namely long submuscular (34.8% of the patients), long subfascial (15.6%), and total circummuscular (13.9%). Overall 56.5% of the patients had at least one favorable DIEA/P. On the other hand, absence of DIEA and absence of adequate (>1 mm) DIEP was reported in 3 and 8 hemiabdomen. Conclusion: Preoperative CTA evaluation of DIEA/P can be used to identify favorable as well as unfavorable courses for dissection to aid surgical planning.

Angioplasty of Bilateral Coronary Ostial Stenosis in a Patient with Takayasu's Arteritis - A case report - (Takayasu 동맥염에 의한 양측 관상동맥 개구부 협착의 개구부 혈관 성형술 - 1례 보고 -)

  • 이응석;정은규;손국희;윤용한;김광호;백완기
    • Journal of Chest Surgery
    • /
    • v.34 no.12
    • /
    • pp.944-947
    • /
    • 2001
  • Coronary artery involvement in Takayasu's arteritis is a relatively rare, and potentially lethal but surgically correctable disease. A 28-year-old female was admitted for the evaluation of headache associated with dizziness, palpitation and claudication of left arm. Her aortogram and coronary angiogram showed Takayasu's arteritis with bilateral coronary ostial stenosis. We performed bilateral coronary ostioplasty with saphenous vein patch graft. The patient was discharged in good condition. We report this case with literature review.

  • PDF

혈관내벽에 홀뮴-166 방사선 분할 조사시 흡수선량 분포

  • 조철우;윤석남;윤준기;이명훈;탁승재;최소연;박경배
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.70-70
    • /
    • 2003
  • 경피적관상동맥성형술(CPTCA)이나 스텐트삽입술 후에 발생하는 재협착을 방지하기 위한 방사선을 조사하는 방법 중에 베타 입자를 방출하는 액체 선원을 catheter풍선 내에 넣어 일정 시간 방사선 조사 시키는 방법이 있다. 조사시킬 혈관의 길이가 길어 한번의 방사선 조사가 어려울 경우 영역을 분할하여 두 번에 나누어 조사할 경우가 있다. 조사영역의 겹치는 부근의 흡수선량이 고선량이나 저선량이 되는가를 알기 위하여 두 풍선간의 접근 거리에 따른 혈관내벽의 흡수선량 분포를 알아보았다. 풍선내의 액체 선원은 Ho-l66을 이용하였고 Ho-l66의 물리적 반감기는 26.8시간이고 최대에너지 1.85 MeV, 평균에너지 0.69 MeV와 최대에너지 1.77 MeV, 평균에너지 0.65 MeV를 갖는 베타 입자를 방출한다. Ho-l66 의 방사선 흡수선량을 측정하기 위하여 GafChromic 필름(Nuclear Associates, Carle Place, NY, USA)을 이용하였고, 방사선이 조사된 필름의 optical density는 videodensitometer(Wellhofer, Schwarzen-bruck, Germany)를 이용하여 값을 읽었다. Catheter 풍선은 직경이 3 mm 이고 길이가 20 mm인 것을 이용하였다. 혈관 내벽의 최대 흡수선량을 표준화하여 겹치는 부분의 흡수선량 분포를 접근 거리에 따라 구하였다. 또한 몬테카를로 시abf레이션으로 확인하였다. 두 풍선의 겹치는 부근의 선량 분포는 풍선 중앙에서 중앙사이의 거리가 21 mm 일 때 중앙에서 20% 증가하였고, 거리가 22 mm일 때와 23 mm일 때 각각 10%와 40%의 감소를 보였다. 풍선 도자의 풍선 안에 베타입자 방출 액체 선원을 넣어 혈관내벽에 방사선 조사하는 방법은 비정거리가 짧아 혈관 내벽 부근에만 방사선을 조사시키고 그 외 중요 장기에는 영향을 덜 미치는 장점이 있다. 그러나 혈관 내벽 표면으로 부터의 거리에 따라 흡수선량이 급격히 떨어지는 분포를 이루기 때문에 두 개의 풍선이 겹치는 부근의 흡수선량은 아주 작은 접근 거리에서도 급격한 변화를 보였다. 따라서 시술 중에 겹치는 부분을 아주 적게 분할하여 정확하게 차례차례로 조사시키기 위해서는 신중한 거리 조정을 하여야 한다.

  • PDF

Retrograde Aortic Dissection after Thoracic Endovascular Aortic Repair for Descending Aorta - 2 case reports- (하행 대동맥 내 스텐트-도관 삽입 후 발생한 역행성 대동맥 박리 - 2예 보고 -)

  • Hong, Soon-Chang;Kim, Jung-Hwan;Lee, Hee-Jeong;Youn, Young-Nam
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.758-763
    • /
    • 2010
  • In current era, thoracic endovascular aortic repair (TEVAR) has gained popularity. But, it bears the risk of serious complications such as treatment failure from endoleak, retrograde aortic dissection caused by injury of aortic wall at landing zone, or aortic rupture resulting from stent graft infection. We report two cases of surgical repair of retrograde aortic dissection after TAVAR applied to acute Stanford type B aortic dissection or traumatic aortic disruption.

Radiation Exposure of Operator in Intracoronary Radiotherapy Using $^{188}Re$ ($^{188}He$을 이용한 혈관내 방사선 치료시 시술자의 방사선 피폭 수준)

  • Chie, Eui-Kyu;Lee, Myung-Mook;Wu, Hong-Gyun
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.4
    • /
    • pp.191-195
    • /
    • 2000
  • This study was undertaken to estimate the exposed dose of the medical personnel during the intracoronary radiotherapy procedure as a part of ongoing SPARE (Seoul National University Hospital Post-Angioplasty Rhenium) trial. Data of thirty-four patients among forty-two irradiated patients participating in this trial due to coronary artery stenosis were retrospectively analyzed. Intracoronary radiotherapy was delivered to the patient immediately after angioplasty ballooning. Prescribed dose was 17 Gy to media of the diseased artery and was delivered with $^{188}Re$ filled balloon catheter. Dosimetry was carried out with GM counter at eight different points. Ten centimeter and forty centimeter from the patient's heart were selected to represent maximum and whole-body exposed dose of the operator, respectively. Median delivered dose was 111.6 mCi with average treatment time of 576 seconds. Average exposed dose rate at 10 cm and 40 cm from the patient's heart were 0.43 mSv/hr and 0.30 mSv/hr, respectively. Average exposed doses per treatment were 0.07 mSv and 0.05 mSv for 10 cm and 40 cm from the patient's heart, respectively. Exposed doses measured are much lower than recommended limit of 50 mSv for radiation workers or 1 mSv for general population in ICRP-60. This study proves that current method of intracoronary radiotherapy incorporated in this trial is very safe regarding radiation protection.

  • PDF

혈관내 Alcohol 주입법에 의한 두경부 정맥 기형증의 치험 2례

  • Kim, Hyeong-Gon;Park, Gwang-Ho;Lee, Ui-Ung;Kim, Jun-Bae;Ju, Jae-Dong;Kim, Dong-Ik
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.13 no.4
    • /
    • pp.444-449
    • /
    • 1991
  • 저자등은 5세 여아의 좌측 하순부에 발생한 정맥기형증 및 25세 여자 환자의 좌측 교근부에 발생한 정맥 기형증에 대하여 비와과적 방법인 직접알콜 주입에 의한 sclerosing therapy 치료한 결과, 별다른 후유증이나 재발의 소견없이 심미적, 기능적으로 양호한 결과를 얻었기에, 과거 sclerosing solution의 단점을 보완한 순수한 알콜제재의 사용을 문헌고찰과 함께 보고하는 바이다.

  • PDF

Evaluation of Anastomotic Strength and in-vitro Degradability with Microvascular Anastomosis Coupler Based on Injection Molding Condition made by Biodegradable Polycaprolactone(PCL) (생체분해성 폴리카프로락톤(PCL) 미세혈관 문합커플러의 사출성형조건에 따른 문합강도 및 in-vitro 분해능 평가)

  • Ahn, Geun-Seon;Han, Gig-Bong;Oh, Seung-Hyun;Park, Jong-Woong;Kim, Cheol-Woong
    • Transactions of the KSME C: Technology and Education
    • /
    • v.1 no.2
    • /
    • pp.167-177
    • /
    • 2013
  • The use of mechanical anastomosis coupler instead of sutures has been increasing in microvascular anastomosis surgery. However, non-biodegradable anastomosis coupler has problems such as not only inflammatory reaction but also remaining permanently in operation wound. Therefore, we fabricated biodegradable anastomosis coupler using injection molding process to overcome the limitation of non-biodegradable anastomosis coupler. In various injection molding process conditions, the shrinkage was calculated with different cylinder temperatures and injection molding pressures and anastomotic strength was measured. As a result, changes in shrinkage hole part larger than the pin part. In addition, the shrinkage in the cylinder at higher temperatures increase. However, the higher the injection pressure, shrinkage tends to decrease, respectively. In-vitro degradation behavior of PCL anastomotic coupler evaluated for 12 weeks, water uptake was increased and molecular weight was accompanied by a reduction in mass of the biological degradation and reduction of anastomotic strength was confirmed. However, decreased levels of anastomotic strength enough to exceed the requirements of preclinical surgery, PCL microvascular anastomosis coupler suitable candidate materials that could identify.

Cardiac Hemangioma of the Anterior Mitral Valve Leaflet - A case report - (승모판막 전엽에 발생한 심장혈관종 - 1예 보고 -)

  • Choi, Jae-Sung;Kim, Eung-Joong
    • Journal of Chest Surgery
    • /
    • v.40 no.12
    • /
    • pp.859-862
    • /
    • 2007
  • A hemangioma at a cardiac valve leaflet is a rare finding. There are only five reported cases in the medical literature and no prior case reported in Korea. A previously healthy 45-year-old woman presented with an acute episode of numbness in the left side of the face and hand. Although no definite abnormalities were found on the neurological examination and testing the echocardiography revealed an echogenic mass in the anterior mitral valve leaflet. The tumor was excised en bloc from the leaflet and the defect was repaired with an autologous pericardial patch. Pathology examination confirmed the mass to be a hemangioma of the valve leaflet. Here we report this case and review the medical literature.

Arterial Complication of Percutaneous Transluminal Angioplasty - A Report of Case - (경피 경관 혈관 성형술후 발생한 동맥내 합병증의 치험 1례)

  • 김상익
    • Journal of Chest Surgery
    • /
    • v.25 no.11
    • /
    • pp.1273-1277
    • /
    • 1992
  • Percutaneous Transluminal Angioplasty[PTA] was introduced by Dotter and JudKins [1964], using coaxial catheters of increasing diameter. The remarkable advances in vascular catheter technology over the past several decades have permitted the development. But the application of the balloon catheters carries with it the risk of arterial injury, thrombosis, embolism, and loss of life or limb. A 53-year-old man was admitted to other hospital due to a intermittent claudication in his right leg for 10 years. and PTA was performed at that hospital. Thereafter he was transferred to our hospital because of coldness, pulselessness, rest pain, ischemic ulcer, and progressing gangrene at the anterior aspect of left lower leg. The left lower extremity was salvaged by left ilio-femoral bypass and later saphenous in situ femoro-popliteal bypass.

  • PDF