• Title/Summary/Keyword: 현장 실증

Search Result 590, Processing Time 0.036 seconds

Engineering-scale Validation Test for the T-H-M Behaviors of a HLW Disposal System (고준위폐기물 처분시스템의 열적-수리적-역학적 거동 규명을 위한 공학적 규모의 실증시험)

  • Lee Jae-Owan;Park Jeong-Hwa;Cho Won-Jin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.2
    • /
    • pp.197-207
    • /
    • 2006
  • The engineering performance of a high level waste repository is significantly dependent upon the T-H-M behavior in the engineered barrier system. An engineering-scale test facility (KENTEX) was set up to validate the T-H-M behaviors in the buffer of a reference disposal system developed in the 2002. The validation tests started on May 31, 2005 and is now in progress. The KENTEX facility and validation test programme are introduced, and pre-operation calculations are also presented to give information on the sensitive location of sensors and operational conditions. This test will provide information (e.g., large-scale apparatus, sensors, monitoring system etc.) needed for 'in-situ' tests, make the validation of a T-H-M model for the T-H-M performance assessment of the reference disposal system, and demonstrate the engineering feasibility of fabricating and emplacing the buffer of a repository.

  • PDF

Ground Resistance Measurement of Large Scale Grounding Mesh and Field Test (대규모접지망의 활선상태 접지저항 측정 및 현장실증)

  • Shin, Dong-Hyuk;Ryu, Hyuk;Choi, Yun-Chong;Jung, Jae-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.198-202
    • /
    • 2004
  • 변전소와 같은 대규모의 전력설비 뿐만 아니라 통실설비에서도 낙뢰의 침입시와 스위치의 동작시 과전압이 발생 될 수 있는 안전상의 문제와 설비의 보호라는 측면에서 접지계통의 중요성은 아무리 강조하여도 부족하다. 그러나 운전중에는 설비의 누설전류와 불평형전류에 의해 형성된 대지전위의 영향으로 운전중인 전력설비를 대상으로 기존의 접지저항측정방식으로 접지저항 측정이 불가능하다. 본 논문에서는 기존의 접지저항 측정방식과 측정법이 동일하면서도 설비가 운전중인 경우에도 접지저항의 측정이 가능한 방법과 측정 장치를 소개한다. 본 방법은 운전중인 전력설비에서 이미 형성된 대지전위성분을 분석하고 이와 간섭을 일으키지 않는 독립적인 주파수를 선정하는 방식을 채택하고 있다. 또한 이러한 방식의 실증을 위하여 대규모 접지망인 변전소를 대상으로 하여 건설 후 운전전과 운전후의 접지저항 측정을 시도하고 이를 비교하였다. 실증시험결과 대규모접지망의 경우에도 설비가 운휴중인 경우의 접지저항간과 운용중인 경우의 접지저항값이 일치함을 실증하였다. 결과적으로 본 논문에서 제안한 방법과 장치의 경우 운전중인 대규모 접지망의 접지저항 측정이 가능하다는 것을 입증하였다.

  • PDF

Dimensionless parameterization in two-Dimensional groundwater flow tank (2차원 지하수 흐름 모의 장비를 이용한 무차원 변수화)

  • Chang, Sun Woo;Kim, Min-Gyu;Kim, Il Hwan;Chung, Il-Moon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.284-284
    • /
    • 2020
  • 지하수 흐름 모의를 위한 2차원 수조모형 실내 실험은 현장에서 발생하는 복잡성을 배재하는 동시에 간편함과 재현가능성을 제시하는 실험 방식이다. 지하수 흐름 모형은 수치모델을 구현하여 계산할 때 검증용 실험 결과를 얻는 목적으로 운용할 수 있으며 또한 테스트베드 규모의 실증 실험을 대신할 용도로 실증부지의 환경을 축소 모의하고자 하는 용도에도 사용할 수 있다. 본 연구는 모형의 길이에 비해 두께가 상대적으로 얇아 지하수 2차원을 모의할 수 있는 실내실험 방식의 표준을 제안한다. 연구 방법에서 인공 매질 및 모래와 같이 수조모형의 흐름 영역을 채우는 매질의 수리전도도 값을 간편하고 신속하게 계산하는 방식을 Dupuit 가정을 바탕으로 구현하였다. 모의하고자 하는 실증 부지와 수조 모형 사이에는 실험 규모의 축소와 확대의 근거를 이론적으로 뒷받침하는 상사성 (similarity)이 존재하여야 한다. 본 연구에서는 상사성을 구현하는데 사용할 수 있는 무차원 변수를 수리지질학적 변수의 조합으로 표현하고자 하였다. 마지막으로 무차원화 변수를 수조 모형에 대입하여 실증부지를 모의하고 결과를 표출하는 방식을 제안하였다.

  • PDF

Power and Economic Simulation of Island for the Field Demonstration Test of Smart Microgrid System Based on Stand-alone Wind power (독립형 풍력기반 Smart Microgrid 시스템의 현장 실증 시험을 위한 도서지역 전력 및 경제성 시뮬레이션)

  • Kang, SangKyun;Lee, EunKyu;Lee, JangHo
    • New & Renewable Energy
    • /
    • v.10 no.3
    • /
    • pp.22-30
    • /
    • 2014
  • The isolated self-generating electricity with diesel engine generator has been used in islands far away from main land. It costs high because of increasing oil price, and unsafe to have supplying oil and its related components by ship due to unexpectable marine conditions. Therefore there is the need for the hybrid system of renewable energy like wind or solar energy systems with oil engine generator, which can reduce oil use and extend oil supplying period. In this study, the feasibility of such hybrid system with smart micro grid on the eight islands of Jeon-nam province is surveyed to find good place for the demonstration test of the hybrid system. In each island, 3 wind turbine systems of 10 kW and photovoltaic of 20 kW are tested with already installed diesel engine. The performance and costs of the hybrid system in each island are compared in the given conditions of solar and wind energy potential. As a result of the study, Jung-ma island is recommended for the optimum place to make real field demonstration test of isolated hybrid generating and smart grid systems.

A Study on the Serious Accident Prevention of Construction Using For P.S.M Policy (PSM제도를 활용한 건설업 중대재해 예방에 관한 연구)

  • 정범모;양광모;강경식
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2002.11a
    • /
    • pp.215-220
    • /
    • 2002
  • 건설현장 재해가 차지하는 국가적 손실을 감소시키기 위해 그동안 정부 및 관계기관과 많은 건설사들의 노력에도 불구하고 건설현장 작업 공정상 중대 사고들이 끊이지 않아 이에 대한 실증적 연구가 절실히 요구되고 있다. 현재 건설업의 안전관리 시스템은 유해·위험방지계획서 제도를 시행하고 있으나, 기존의 다른 자료를 답습한 내용이 대부분이고, 대규모 공사인 경우는 유해·위험방지계획서 작성 자체도 큰 부담을 갖을 수밖에 없는 현실에서 실질적인 수행이 어려운 실정이다. 그리고, 공사 착공 후 잦은 설계변경과 공법 변화 등에 따른 위험 요인에 적절히 대응하지 못하는 문제점이 도출되고 있다. 이러한 연유로 각각의 작업공정 개시전 공정별 작업 안전계획을 수립하여 적기에 능동적이고 유기적인 사전위험요인 제거가 가능한 공정안전관리기법(PSM: Process Safety Management)을 건설분야에 도입하여 시행하는 것이 필요하다고 사료된다. 본 논문에서는 이러한 문제점을 해결하고자 건설현장에 핵심공정에 대한 사전 안전성 확보로 재해를 예방하는 P.S.M. 기법을 도입하여 건설업 중대재해를 예방하는 방안을 찾아보고자 한다.

  • PDF

An Empirical Study on Firefighters' Health Hazard Factors -Focused on Fire Fighters, Rescue Workers and Emergency Medical Technicians Perception in Busan Fire Fighters- (소방공무원 건강장해 유해인자에 대한 실증연구 -화재진압대원, 구조대원, 구급대원의 인식조사를 중심으로-)

  • Kwon, Seol A;Lee, Min-Kyu;Park, Sang Ho;Kim, Da Young;Ryu, Sang Il
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.3
    • /
    • pp.520-529
    • /
    • 2019
  • This study is intended to provide basic data for health management of firefighters in the future by empirically looking into health hazard factors of firefighters in Busan City. It was revealed that firstly, the danger of harmful chemicals in a fire was perceived the most by firefighters, who extinguish a fire in person on the scene of a fire, and it was followed by the danger of falling while putting out a fire. This study is intended to provide basic data for health management of firefighters in the future by empirically looking into health hazard factors of firefighters in Busan City. It was revealed that firstly, the danger of harmful chemicals in a fire was perceived the most by firefighters, who extinguish a fire in person on the scene of a fire, and it was followed by the danger of falling while putting out a fire. Moreover, the danger of shift work was perceived the most by paramedics. This corresponds to the existing studies arguing that shift work is harmful to health. Next, the overload of patient transport was recognized as the second biggest hazard factor. This demonstrates they are worried about various second accidents that may happen due to a lot of patient transport works. In addition, the possibility of causing a traffic accident was perceived as a hazard factor too, since they must drive ambulance cars quickly to transport patients. Lastly, rescue workers regarded these hazard factors to be most dangerous. This is associated with their occupational characteristics, because rescue workers are the closest to diverse risks including a fire.

Development of a Portable-Based Smart Structural Response Monitoring System and Evaluation of Field Applicability (포터블 기반 스마트 구조 응답 모니터링 시스템 개발 및 현장 적용성 평가)

  • Sangki Park;Dong-Woo Seo;Ki-Tae Park;Hojin Kim;Thanh Bui-Tien;Lan Nguyen-Ngoc
    • Journal of Korean Society of Disaster and Security
    • /
    • v.16 no.4
    • /
    • pp.147-156
    • /
    • 2023
  • Because the behavior of cable bridges is dominated by dynamic response and is relatively complex, short- and long-term field monitoring are often required to evaluate the bridge condition. If a permanent SHMS (Structural Health Monitoring System) is not installed, a portable monitoring system is needed for the checking of bridge condition. In this case, it can be difficult to operate the portable monitoring system due to limited conditions such as power and communication according to the location and type of the bridge. In this study, the portable-based smart structural response monitoring system is developed that can be effectively used for short- and long-term monitoring of cable bridges in Korea and Southeast Asia. The developed system is a multi-channel portable data acquisition and analyzer that can be operated for a long time in the field using its own power supply system, and is included with the automated analysis algorithm for the dynamic characteristics of cable bridges using real-time data. In order to evaluate the field applicability of the developed system, field demonstration was conducted on cable bridges in Korea and Vietnam. Through the demonstration, the reliability and efficiency of field operation of the developed system were confirmed, and additionally, the possibility of application to overseas markets was confirmed in cable bridge monitoring field.

인적판매원을 활용한 구매시점고광고 연구: 정보전달형태에 따른 효과 분석

  • Park, Sun-Chan;O, Sang-Do
    • 한국벤처창업학회:학술대회논문집
    • /
    • 2016.04a
    • /
    • pp.154-156
    • /
    • 2016
  • 이 연구의 목적은 소비자의 구매의도를 자극하고, 판매를 촉진시켜주는 구매시점광고(POP Ad: Point Of Purchase Advertising)의 소매판매 유통점 활용영역에서 정보전달형태 변화에 따른 광고효과 차이가 있는지를 연구하는데 있다. 연구의 배경과 방법은 통상의 구매시점광고가 정보전달 방법에 있어서 소비자 구매활동 장소 내 외에서 단순 비치, 설치된 상태로서 기능과 역할을 수행하고 있음을 착안, 광고소구형태를 시각, 청각 그리고 인적판매원이 관여된 혼합(시각, 청각)형으로 분류하여 정보를 전달 한 후 소비자의 태도 및 매출 비교를 위해 실증적 실험을 했다. 본 연구의 핵심 가설은 '인적판매원이 개입된 혼합형(시각, 청각) 구매시점광고가 소비자 태도(신뢰도/호감도/구매의도) 및 매출( + / -)영향도가 더욱 높게 나타날 것이다'이다. 이는 소비자에게 시각, 청각이 동시에 전달되는 혼합소구유형은 정보전달력이 우수하고, 광고 효과성이 높을 것이다를 검증하기 위한 것이다. 본격 연구 전에 실시한 1차 사전적 실증 실험결과 소비자가 지각하는 관점에 따라 시각형(광고의 정보내용을 인쇄물로 제공), 청각형(광고의 정보내용을 소리전달형태로 제공), 시각, 청각 혼합형(인적판매원이 시각형 정보를 활용 광고내용을 직접 전달)분류한 3가지 유형간 정보전달 효과의 차이는 없는 것으로 나왔다. 하지만, 본 연구는 생계형 소매유통 창업현장에서 활동하고 있는 소상공인들이 구매시점광고를 광고의 활용측면에서 능동형 마케팅 활동 도구로 사용할 수 있는지에 대한 실증적 사례 분석을 했다는 것에 의의를 두고자 한다. 업종별 차이는 있지만 대부분의 소상공인들의 마케팅 환경은 열악하다. 마케팅 전담 인력의 부재, 마케팅 지식의 부족, 전방위적 마케팅 전개 시간의 한계 등으로 인해 체계적으로 마케팅활동을 펼 칠 수 없는게 현실이다. 이에 현장 활용성이 높은 효율적이고 효과적인 구매시점광고의 광고정보전달 연구 및 개발이 요구된다고 보며, 이에 관한 지속적인 후행적 연구와 노력이 필요하다고 사료된다.

  • PDF

A Study about Measurement Method for Quantitative Classification of Breeding Pig's Locomotor Behaviors using Ultrasonic Sensor Array (초음파 센서 어레이를 이용한 모돈 지제이상 정량분석 방법 연구)

  • Cho, Jinho;Oh, Jong-woo;Lee, DongHoon
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.163-163
    • /
    • 2017
  • 모돈은 교배, 임신, 분만, 포유, 이유를 순환적 반복을 요구하는 개체로서 스마트 농장 시스템의 생산성 향상에 있어서 중요한 요소이다. 본 연구에서는 모돈 능력의 극대화 및 최적의 시스템 관리를 위해서 초음파 센서를 활용한 모돈의 지제 이상 징후를 실시간으로 계측할 수 있는 시스템을 개발하였다. 이 시스템은 높이에 따라 상-중-하(30 cm 간격), 위치에 따라 전면부-후면부에 초음파 센서를 설치하고 이를 마이크로 컨트롤러에 연결하여 모돈의 지제 이상 유무 측정이 가능하도록 하였다. 모돈의 체형과 위치를 고려하여 설치된 초음파 센서의 위치 조절이 가능하도록 하였다. 또한 소형 LCD 모듈을 내장하여 실시간 모니터링이 가능하도록 하였으며, 측정된 데이터는 저장장치인 microSD 카드에 저장되도록 하였다. 모돈사의 환경을 고려하여 방밀형 구조로 하우징 마감하였다. 이 모돈 지체 이상 분석 시스템에 사용된 툴은 C언어를 이용하였다. 건강한 모돈을 대상으로 모돈의 지제의 관찰을 위하여 총 12회의 현장 실증실험이 수행되었으며, 현장 실증 시험 중 소요된 시간은 현장의 상황에 따라 다소 상이하였다 (8시간-28일). 높이 상에 위치한 전면부 및 후면부 초음파 센서 모두에서 모돈이 검출이 된 경우 정상 기립으로 간주하였고, 높이 상에 위치한 전면-후면부 초음파 센서 모두에서 모돈이 검출이 되지 않은 경우 정상적으로 누워 있는 걸로 간주하였다. 높이 하에 위치한 전면부 혹은 후면부 초음파 센서 한곳만 모돈이 검출된 경우 비정상적인 기립으로 간주하였다. 취득된 데이터를 분석한 결과 모돈의 정상적 상태 (기립상태, 누운 상태, 앉은 상태)와 그 외의 비정상적 상태로 분류가 가능하다. 또한 측정된 초음파 센서의 진동의 유무 및 파동형태에 따라서 모돈의 상태 예측이 가능하다. 초음파 센서의 진동 파동이 크고 안정된 상태인 경우 정상적인 활동 상태로 판단하였으며, 진동 파동이 작고 안정적인 경우는 수면 상태로 분류하였다. 실시간으로 지속적인 데이터 획득을 위하여 차후 초음파 센서 및 시스템의 보완작업이 필요하다. 이와같은 모돈의 행동 패턴에 따른 취득된 데이터를 분류하여 모돈의 발정에 의한 행동 특성(기립시간) 분석에 따른 발정 적기 발견 및 정량화 기술 개발에 활용이 가능하다.

  • PDF