• 제목/요약/키워드: 현장적용 성능평가

검색결과 555건 처리시간 0.027초

The study of developing the freezing seal isolation method for the pre insulated heat transfer pipe (이중보온 열수송관에 대한 동결차수공법개발에 관한 연구)

  • You, Byounghee;Ahn, Changkoo;Kim, Woocheol;Shin, Ikho
    • Journal of Energy Engineering
    • /
    • 제26권3호
    • /
    • pp.105-112
    • /
    • 2017
  • A lot of piping systems have been used from nuclear power systems to water supply systems. The maintenance of the piping systems is needed to ensure proper operation of the piping systems. Failure of the large pipe systems especially such as KDHC(Korea District Heating Corporation) can be a matter directly related to the enterprise productivity and profitability. It can also lead to very important issues in promoting public safety and convenience. Therefore a method of quick and safety repairs have been emerged as the most important problem. In this study, freezing seal isolation method using liquid nitrogen cryogenic refrigerant was developed for the maintenance of a pre insulated heat transport pipe of KDHC with a diameter of 300 mm. In this study, by employing computational analysis techniques we performed the flow and heat transfer analysis for the targeted pre insulated heat transfer pipe and freezing seal jacket(ice-Plug) and have selected for optimal system. The detailed design model based on the results of the computational analysis finally was produced. A laboratory-scale test apparatus were designed and the freezing seal isolation self-test carried out. Also the performance assessment tests in the test bed of KDHC were carried out for on-site application.

Development of Fender Segmentation System for Port Structures using Vision Sensor and Deep Learning (비전센서 및 딥러닝을 이용한 항만구조물 방충설비 세분화 시스템 개발)

  • Min, Jiyoung;Yu, Byeongjun;Kim, Jonghyeok;Jeon, Haemin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • 제26권2호
    • /
    • pp.28-36
    • /
    • 2022
  • As port structures are exposed to various extreme external loads such as wind (typhoons), sea waves, or collision with ships; it is important to evaluate the structural safety periodically. To monitor the port structure, especially the rubber fender, a fender segmentation system using a vision sensor and deep learning method has been proposed in this study. For fender segmentation, a new deep learning network that improves the encoder-decoder framework with the receptive field block convolution module inspired by the eccentric function of the human visual system into the DenseNet format has been proposed. In order to train the network, various fender images such as BP, V, cell, cylindrical, and tire-types have been collected, and the images are augmented by applying four augmentation methods such as elastic distortion, horizontal flip, color jitter, and affine transforms. The proposed algorithm has been trained and verified with the collected various types of fender images, and the performance results showed that the system precisely segmented in real time with high IoU rate (84%) and F1 score (90%) in comparison with the conventional segmentation model, VGG16 with U-net. The trained network has been applied to the real images taken at one port in Republic of Korea, and found that the fenders are segmented with high accuracy even with a small dataset.

Experimental Study on Deformation Resistance Capacity of SY Permanent Steel Form for RC Beam and Girder under Casting Concrete (SY 비탈형 보 거푸집의 콘크리트 타설시 변형저항성능에 관한 실험적 연구)

  • Bae, Kyu-Woong;Shin, Sang-Min
    • Journal of the Korea Institute of Building Construction
    • /
    • 제21권6호
    • /
    • pp.605-615
    • /
    • 2021
  • Recently, to shorten construction periods and reduce labor costs, the need for a corrugated beam form in the RC structure is being emphasized. The purpose of this study is to evaluate the deformation performance of SY Beam, a newly developed corrugated beam form work, during concrete casting. The standard cross-sectional shape of SY Beam was determined by modeling the deck structure of various thicknesses using the MIDAS GEN program. As a result, the cross-sectional dimensions of the SY Beam were determined to be 400mm and 450mm in width and height, respectively. A total of three SY Beam specimens were fabricated using steel plate thicknesses of 0.8, 1.0, and 1.2mm. The load conditions applied during casting concrete at the actual site are reflected. The vertical and horizontal displacements of the SY beam were measured during concrete casting. As a result, the vertical displacement showed a tendency to decrease as the thickness increased. Considering both vertical and horizontal displacement, the case with steel plate thickness of 1.2mm is the safest and most immediately applicable to the field. In the future, to secure manufacturability, constructability, and economics, the optimum steel plate thickness should be derived, and additional analysis and experimental studies for 1.05, 1.1, and 1.15mm are required.

Consolidation Behavior of Soft Ground by Prefabricated Vertical Drains (페이퍼드레인 공법에 의한 연약지반의 압밀거동)

  • Lee, Dal Won;Kang, Yea Mook;Kim, Seong Wan;Chee, In Taeg
    • Korean Journal of Agricultural Science
    • /
    • 제24권2호
    • /
    • pp.145-155
    • /
    • 1997
  • The large scaled field test by prefabricated vertical drains was performed to evaluate the superiority of vertical discharge capacity for drain materials through compare and analyze the time-settlement behavior with drain spacing and the compression index and consolidation coefficient obtained by laboratory experiments and field monitoring system. 1. The relation of measurement settlement($S_m$) versus design settlement($S_t$) and measurement consolidation ratio($U_m$) versus design consolidation ratio($U_t$) were shown $S_m=(1.0{\sim}1.1)S_t$, $U_m=(1.13{\sim}1.17)U_t$ at 1.0m drain spacing and $S_m=(0.7{\sim}0.8)S_t$, $U_m=(0.92{\sim}0.99)U_t$ at l.5m drain spacing, respectively. 2. The relation of field compressing index($C_{cfield}$) and virgin compression index($V_{cclab.}$) was shown $C_{cfield}=(1.0{\sim}1.2)V_{cclab.}$, But it was nearly same value when considered the error with determination method of virgin compression index and prediction method of total settlement. 3. Field consolidation coefficient was larger than laboratory consolidation coefficient, and the consolidation coefficient ratio($C_h/C_v$) were $C_h=(2.4{\sim}3.0)C_v$. $C_h=(3.5{\sim}4.3)C_v$ at 1.0m and 1.5m drain spacing and increased with increasing of drain spacing. 4. The evaluation of vertical discharge capacity with drain spacing from the results of the consolidation coefficient ratio showed largely superior in case the Mebra drain and Amer drain than other drain materials at 1.0m and 1.5m drain spacing, while the values showed nearly same value in case same drain spacing.

  • PDF

Field Application of Waterworks Automatic Meter Reading and Analysis of Household Water Use (상수도 원격검침시스템의 현장 적용성 평가 및 가정용수 사용량 분석)

  • Joo, Jin Chul;Ahn, Hosang;Ahn, Chang Hyuck;Ko, Kyung-Rok;Oh, Hyun Je
    • Journal of Korean Society of Environmental Engineers
    • /
    • 제34권10호
    • /
    • pp.656-663
    • /
    • 2012
  • After the construction of waterworks automatic meter reading with 15 mm diameter digital water mater with magnetoresistance sensor developed in this study at 96 households of apartment complexes located in Incheon-City B-Gu S-Dong, the feasibility of field application of waterworks automatic meter reading was evaluated. The field application of waterworks automatic meter reading was performed from July to December in 2011, and average reception rate was as low as 84.6% due to the instable wibro networks, the existence of communication blackout and temporary malfunction of router. After the extraction of 10 households with one to five residents out of 96 households by using stratified random sampling method and analysis of domestic water use, it was found that domestic water use was significant at August and showed a decreasing trend at September, followed by increase in domestic water use at November and decrease in domestic water use at December. This phenomenon should be attributed to weather factors (temperature, humidity, etc.), which significantly affected domestic water use. Similar trend in domestic water use in terms of weather factors was obtained in case of Liter per capita day of water use after the extraction of 30 households out of 96 households by using stratified random sampling method. After analysis of Liter per capita day for 96 households, single residents increases resulted in reduction of domestic water usage by about 14% of Liter per capita day. These results might be due to the fact that domestic water usage such as laundry, beverages, catering, cleaning, etc. should be required for even the household with one resident, whereas domestic water usage for those common utilization can be significantly saved for the household with more than one resident.

Modeling and Intelligent Control for Activated Sludge Process (활성슬러지 공정을 위한 모델링과 지능제어의 적용)

  • Cheon, Seong-pyo;Kim, Bongchul;Kim, Sungshin;Kim, Chang-Won;Kim, Sanghyun;Woo, Hae-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • 제22권10호
    • /
    • pp.1905-1919
    • /
    • 2000
  • The main motivation of this research is to develop an intelligent control strategy for Activated Sludge Process (ASP). ASP is a complex and nonlinear dynamic system because of the characteristic of wastewater, the change in influent flow rate, weather conditions, and etc. The mathematical model of ASP also includes uncertainties which are ignored or not considered by process engineer or controller designer. The ASP is generally controlled by a PID controller that consists of fixed proportional, integral, and derivative gain values. The PID gains are adjusted by the expert who has much experience in the ASP. The ASP model based on $Matlab^{(R)}5.3/Simulink^{(R)}3.0$ is developed in this paper. The performance of the model is tested by IWA(International Water Association) and COST(European Cooperation in the field of Scientific and Technical Research) data that include steady-state results during 14 days. The advantage of the developed model is that the user can easily modify or change the controller by the help of the graphical user interface. The ASP model as a typical nonlinear system can be used to simulate and test the proposed controller for an educational purpose. Various control methods are applied to the ASP model and the control results are compared to apply the proposed intelligent control strategy to a real ASP. Three control methods are designed and tested: conventional PID controller, fuzzy logic control approach to modify setpoints, and fuzzy-PID control method. The proposed setpoints changer based on the fuzzy logic shows a better performance and robustness under disturbances. The objective function can be defined and included in the proposed control strategy to improve the effluent water quality and to reduce the operating cost in a real ASP.

  • PDF

Quantitative Evaluation of Super-resolution Drone Images Generated Using Deep Learning (딥러닝을 이용하여 생성한 초해상화 드론 영상의 정량적 평가)

  • Seo, Hong-Deok;So, Hyeong-Yoon;Kim, Eui-Myoung
    • Journal of Cadastre & Land InformatiX
    • /
    • 제53권2호
    • /
    • pp.5-18
    • /
    • 2023
  • As the development of drones and sensors accelerates, new services and values are created by fusing data acquired from various sensors mounted on drone. However, the construction of spatial information through data fusion is mainly constructed depending on the image, and the quality of data is determined according to the specification and performance of the hardware. In addition, it is difficult to utilize it in the actual field because expensive equipment is required to construct spatial information of high-quality. In this study, super-resolution was performed by applying deep learning to low-resolution images acquired through RGB and THM cameras mounted on a drone, and quantitative evaluation and feature point extraction were performed on the generated high-resolution images. As a result of the experiment, the high-resolution image generated by super-resolution was maintained the characteristics of the original image, and as the resolution was improved, more features could be extracted compared to the original image. Therefore, when generating a high-resolution image by applying a low-resolution image to an super-resolution deep learning model, it is judged to be a new method to construct spatial information of high-quality without being restricted by hardware.

Study on Heat Treatment of Red Pine Log (소나무 원목의 열처리에 관한 연구)

  • Eom, Chang-Deuk;Han, Yeonjung;Shin, Sang Chul;Chung, Yeong Jin;Jung, Chan Sik;Yeo, Hwanmyeong
    • Journal of the Korean Wood Science and Technology
    • /
    • 제35권6호
    • /
    • pp.50-56
    • /
    • 2007
  • FAO standard for heat sterilization of wood, International standards for phytosanitary measures (ISPM) No.15, must meet heat-treated wood core temperature to be higher than $56^{\circ}C$ and keep the temperature for more than 30 minutes. This study was carried out to analyze the heat treatment characteristics of domestic pinewood sterilized with the FAO standard. To enhance the effectiveness of heat treatment process in mountainous district energy consumption and time required to reach target temperature were evaluated at various temperature and relative humidity conditions and moisture contents of wood. Heat-treatment of high temperature and high humidity reduced the required heating time. Lower humidity levels at same temperature reduced energy consumption per unit time. However, lower humidity levels could not reduce total energy consumption greatly because longer treatment time was required at that condition. It is necessary to estimate energy consumption and predict treatment time in dynamic heating and cooling situations, because it frequently happens not to meet optimum treatment condition due to poor surrounding climates and operation performance of heat treatment facility in real field.

Analysis on the Reduction Effects of the Gravity Waves and Infra-Gravity Waves of Detached Submerged Breakwater by Field Monitoring (현장관측을 통한 이안소파잠제의 중력파 및 중력외파 저감효과 검토)

  • Jeong, Weon-Mu;Back, Jong-Dai;Choi, Hyukjin;Kim, Sang-Ik
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • 제30권2호
    • /
    • pp.51-60
    • /
    • 2018
  • This study was conducted to observe the effects of gravity and infra-gravity wave of detached submerged breakwater in the coast of Yeongnang-dong, Sokcho, as analyzing continuous wave data by performing field observations on the front area (W0) and rear area (W1, W2). Wave transmission coefficient ($K_t$) of submerged breakwater was analyzed in two parts, short-period wave (gravity wave) and infra-gravity wave. The wave energy reduction effect was analyzed and compared with the value of the design. In case of above wave height 2.0 m at the front area (W0) of the submerged breakwater, the short-period wave height at point W1 is reduced by about 65% and the short-period wave height at point W2 is reduced by about 59%. The depth of crest of submerged breakwater conducted in a sea area differs from the design, and the wave energy reduction effect is analyzed to be smaller than the design plan. The infra-gravity waves were amplified to 2.11 and 1.71 at the W1 and W2 points, respectively, and the wave height at W2 point was smaller than that at W1 point.

A small ocean bottom electromagnetometer and ocean bottom electrometer system with an arm-folding mechanism (Technical Report) (팔-접힘 구조를 가지는 소규모 OBEM과 OBE시스템 (기술보고서))

  • Kasaya, Takafumi;Goto, Tada-nori
    • Geophysics and Geophysical Exploration
    • /
    • 제12권1호
    • /
    • pp.41-48
    • /
    • 2009
  • Natural magnetic fields are attenuated by electrically conductive water. For that reason, marine magnetotelluric surveys have collected data at long periods (1000-100 000 s). The mantle structure has been the main target of seafloor magnetotelluric measurements. To ascertain crustal structure, however, electromagnetic data at shorter periods are important, e.g. in investigations of megathrust earthquake zones, or in natural resource surveys. To investigate of the former, for example, electromagnetic data for periods of less than 1000 s are necessary. Because no suitable ocean bottom electromagnetometer (OBEM) has been available, we have developed a small OBEM and ocean bottom electrometer (OBE) system with a high sample rate, which has an arm-folding mechanism to facilitate assembly and recovering operations. For magnetic observation, we used a fluxgate sensor. Field observations were undertaken to evaluate the field performance of our instruments. All instruments were recovered and their electromagnetic data were obtained. Results of the first experiment show that our system functioned well throughout operations and observations. Results of other field experiments off Tottori support the claim that the electromagnetic data obtained using the new OBEM and OBE system are of sufficient quality for the survey target. These results suggest that this device removes all instrumental obstacles to measurement of electromagnetic fields on the seafloor.