• Title/Summary/Keyword: 현장적용 성능평가

Search Result 555, Processing Time 0.029 seconds

Application and Evaluation of the Attention U-Net Using UAV Imagery for Corn Cultivation Field Extraction (무인기 영상 기반 옥수수 재배필지 추출을 위한 Attention U-NET 적용 및 평가)

  • Shin, Hyoung Sub;Song, Seok Ho;Lee, Dong Ho;Park, Jong Hwa
    • Ecology and Resilient Infrastructure
    • /
    • v.8 no.4
    • /
    • pp.253-265
    • /
    • 2021
  • In this study, crop cultivation filed was extracted by using Unmanned Aerial Vehicle (UAV) imagery and deep learning models to overcome the limitations of satellite imagery and to contribute to the technological development of understanding the status of crop cultivation field. The study area was set around Chungbuk Goesan-gun Gammul-myeon Yidam-li and orthogonal images of the area were acquired by using UAV images. In addition, study data for deep learning models was collected by using Farm Map that modified by fieldwork. The Attention U-Net was used as a deep learning model to extract feature of UAV in this study. After the model learning process, the performance evaluation of the model for corn cultivation extraction was performed using non-learning data. We present the model's performance using precision, recall, and F1-score; the metrics show 0.94, 0.96, and 0.92, respectively. This study proved that the method is an effective methodology of extracting corn cultivation field, also presented the potential applicability for other crops.

An analysis on the relative importance of aptitude test items for integrated pilot aptitude evaluation (종합적 조종적성 판단을 위한 적성 검사 항목의 상대적 중요도 분석)

  • 유희천;이달호;김영준
    • Proceedings of the ESK Conference
    • /
    • 1993.10a
    • /
    • pp.46-55
    • /
    • 1993
  • 조종사가 수행하는 조종 업무는 여러 정보를 동시에 지각하여 처리하여 야 하는 복잡한 작업으로 구성되어 있어, 조종사에게는 고도의 인간성능이 요구되고 있다. 또한 조종기술을 습득하기 위해서는 많은 훈련시간과 비용 이 소요되며, 조종사의 실수는 치명적인 사고를 초래한다. 따라서 조기에 비행 부적격자를 판별하고, 미흡한 조종 적성을 함양시킬 수 있는 교육 . 훈련 프로그램을 조종 후보생에게 적용시키는 분석적 조종적성 진단 체계 개발은 조 종사의 도태율 감소, 효율적인 비행훈련, 비행 안전사고 감소 등의 측면에서 절실하게 요구되고 있다. 본 연구에서는 조종 업무 수행시 요구되는 여러 인간 기능의 중요도 차이를 조종 적성 평가 체제에 적용하기 위해서, 각 적성 검사 항목들의 상대적 중요도를 분석하고 이의 타당성을 평가하였다. 적성검사 항목의 상대적 중요도 분석은 조종적성검사 계층구조의 각 수준별 쌍체 비교 평가와 AHP(Analytic Hierarchy Process) 분석에 의한 상대적 중요도 산출 및 평가, 그리고 일관성 지수(Consistency Index)에 의한 분석 결과의 조정을 통해 이루어 졌다. 적성검사 항목의 쌍체 비교 평가는 심리기능검사, 비행자질 검사 등 총 29개 적성검사 항목에 대해 검사를 받았고 또한 초등비행 훈련과정을 수료한 조종 학생들에 의해 이루어 졌다. 상대적 중요도를 분석한 결과 심리기능 검사(W=0.30)가 다른 검사에 비하여 조종적성 평가에 중요한 검사로 나타났으며, 세부 항목으로는 주의 분배력(W=0.13), 추적능력(0.06) 등이 상대적으로 중요한 검사 항목으로 나타났다. 또한 상대적 중요도 결과를 적용한 적성검사 성적이 적용하지 않은 적성검사 성적에 비해 비행성적에 대한 예측 능력이 좋은 것으로 평가되었다.al age)가 있다는 것을 의미하는 것이다. 한편, 생산현장에서는 자동화, 기계화가 진보되어 육체적인 노동이 경감된 결과, 중고령자라도 할 수 있는 작업이 많아지고 있다. 또, VDT (Visual Dislay Terminal) 작업과 같은 정보처리 작업의 수요가 증가하여 그 인재의 부족이 지적되고 있다. 따라서 중고령자의 기능을 조사하여 어떠한 작업에 적합한가를 판단하는 것이 중요한 과제로 되었다. 그러나 노동에는 많은 기능이 관여 하고, 그 내용에 따라서 요구되는 기능이 서로 다르기 때문에 노동적응능력의 기본적인 기능으로 보여지는 것에 좁혀서 작업능력의 연령증가 변화에 대하여다원적 평가를 하는 것이 실제적이라고 할 수 있다. 따라서 본 연구에서는 인간이 가지고 있는 다수의 기능중에서 수지교 치성과 연령증가와의 관계를 조사한다. 만약 연령증가 만으로 수지교치성을 평가 할 수 없는 경우에는 어떠한 요인이 수지기민성의 변화에 영향을 미치는가를 검토한다.t list)에서 자동적으로 사건들의 순서가 결정되도록 확장하였으며, 설비 제어방식에 있어서도 FIFO, LIFO, 우선 순위 방식등을 선택할 수 있도록 확장하였다. SIMPLE는 자료구조 및 프로그램이 공개되어 있으므로 프로그래머가 원하는 기능을 쉽게 추가할 수 있는 장점도 있다. 아울러 SMPLE에서 새로이 추가된 자료구조와 함수 및 설비제어 방식등을 활용하여 실제 중형급 시스템에 대한 시뮬레이션 구현과 시스템 분석의 예를 보인다._3$", chain segment, with the activation energy of carriers from the shallow trap with 0.4[eV], in he amorphous regions.의 증발산율은 우기의 기상자료를 이용하여 구한 결과

  • PDF

Concrete plug cutting using abrasive waterjet in the disposal research tunnel (연마재 워터젯을 활용한 처분터널 내 콘크리트 플러그 절삭)

  • Cha, Yohan;Kim, Geon Young;Hong, Eun-Soo;Jun, Hyung-Woo;Lee, Hang-Lo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.2
    • /
    • pp.153-170
    • /
    • 2022
  • Waterjet has been comprehensively used in urban areas owing to a suitable technique for cutting concrete and rock, and low noise and vibration. Recently, the abrasive waterjet technique has been adopted and applied by the Korea Atomic Energy Research Institute to demolish concrete plugging without disturbing and damaging In-situ Demonstration of Engineered Barrier System in the disposal research tunnel. In this study, the use of abrasive waterjet in the tunnel was evaluated for practical applicability and the existing cutting model was compared with the experimental results. As a variable for waterjet cutting, multi-cutting, water flow rate, abrasive flow rate, and standoff distance were selected for the diversity of analysis. As regarding the practical application, the waterjet facilitated path selection for cutting the concrete plugging and prevented additional disturbances in the periphery. The pump's noise at idling was 64.9 dB which is satisfied with the noise regulatory standard, but it exceeded the standard at ejection to air and target concrete because the experiment was performed in the tunnel space. The experimental result showed that the error between the predicted and measured cutting volume was 12~13% for the first cut and 16% for second cut. The standoff distance had a significant influence on the cutting depth and width, and the error tended to decrease with decrement of standoff distance.

A Study on Development of Alternative Non-aqueous Cleaning Agents to Ozone Depletion Substances and its Field Application (오존파괴물질 대체 비수계세정제 개발 및 현장 적용 연구)

  • Park, Yong-Bae;Bae, Jae-Heum;Lee, Min-Jae;Lee, Jong-Gi;Lee, Ho-Yeoul;Bae, Soo-Jung;Lee, Dong-Kee
    • Clean Technology
    • /
    • v.17 no.4
    • /
    • pp.306-313
    • /
    • 2011
  • Flux or solder is used in soldering process for manufacturing electronic parts such as printed circuit boards (PCB). After soldering process, residual flux and solder paste on the parts should be removed since their residuals could cause performance degradation or failure of parts due to their corrosion and electric leakage. Ozone depletion substances such as 1,1,1- trichloroethane (TCE) and HCFC-141b have widely been using for removal of residual flux and solder paste after soldering process In manufacturing of electronic parts until now. In this study, non-aqueous cleaning agents without flash point were developed and applied to industrial field for replacement of cleaning agents with ozone depletion. In order to develop non-aqueous cleaning agents without ethers, esters, fluoride- type solvents. And their physical properties and cleaning abilities were evaluated, and they were applied to industrial fields for cleaning of flux and solder on the PCB. And vacuum distillation apparatus were operated to determine their operating conditions and recycling yields for recycling of used cleaning agents formulated in this study. As a result of physical properties measurement of our formulated cleaning agents, they were expected to have good wetting and penetrating power since their surface tensions were relatively low as 18.0~20.4 dyne/$cm^2$ and their wetting indices are relatively large. And some cleaning agents holding fluoride-type solvents as their components did not have any flash point and they seemed to be safe in their handling and storage. The cleaning experimental results showed that some cleaning agents were better in their cleaning of flux and solder paste than 1,1,1-TCE and HCFC-141b. And industrial application results of the formulated cleaning agents for cleaning PCB indicated that they can be applicable to industry due to their good cleaning capability in comparison with HCFC-141b. The recycling experiments of the used formulated cleaning agents through a vacuum distillation apparatus also showed that their 91.9~97.5% could be recycled with its proper operating conditions.

Performance evaluation of high-performance lattice girder using numerical analysis (수치해석을 통한 고성능 격자지보재의 성능 평가)

  • Kim, Dong-Gyou;Ahn, Sungyoull
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.6
    • /
    • pp.897-908
    • /
    • 2019
  • The objective of this study is to evaluate the field support performance of highperformance lattice girder (BK-Lattice Girder) by using numerical analysis. Three types (50, 70, 95-type) of existing and high performance lattice girders were applied to the cross section of highway 2, 3, and 4 lane tunnels to compare the supporting performance. The numerical analysis was the finite element method and the lattice girder was modeled in three dimensions with an elasto-plastic frame. The ground was modeled as a spring receiving only compression. The load was applied as a concentrated load on the central ceiling of the tunnel section. The yield strengths of the lattice girders were determined from the numerical results to compare the supporting performance of lattice girder. In case of 50-type, the yield strengths of high-performance lattice girders were increased by 6.7~10.0% compared with those of the existing lattice girders. In the case of 70-type, the high-performance lattice girders increased yield strengths by 12.1~14.9% than the existing lattice girder. In the case of 95-type, the high-performance lattice girders increased yield strengths by 13.3~20.0% than the existing lattice girder. As a result of numerical analysis, it was considered that the high-performance lattice girder supported better than the existing lattice girder when only the lattice girders were constructed.

Experimental Studies on Bond and Splice Performance of Splice Sleeve for Connecting Rebar (철근연결용 스플라이스 슬리브의 이음 및 부착성능에 대한 실험적 연구)

  • Kang, Duk Man;Park, Yong Gul;Lee, Hyeon Gi;Moon, Do Young
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.2
    • /
    • pp.257-264
    • /
    • 2017
  • The PC (Precast Concrete) construction method is a technique where concrete members that have been produced in a plant are constructed on site. Thus, continuity and secure integration of a structure that can be obtained by connecting rebars at splicing joint for PC members are the main areas of concern for this method. To evaluate the splicing and bonding performance according to application of a splice sleeve for connecting rebar in this research study, the diameter of rebar, development length, grouting strength etc. were set as variables. The performance and stiffness of splicing according to the development length of grout strength were measured and evaluated. In addition, by conducting comparative analysis on each of the variables, the factors that affected the splice sleeve for connecting rebar were discussed. The results confirmed that the strength and stiffness of the splice sleeve for connecting rebar were significantly affected by the development length while the increase in performance according to grout strength was not as significant.

The Study of Measurement and Performance Evaluation for Elevator Equipment by Instantaneous Power Quality (순시전원품질 측정 및 변화에 따른 승강기 설비의 성능평가에 관한 연구)

  • Kim, Gi-Hyun;Bang, Sun-Bae;Lee, Joo-Hwan;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.5
    • /
    • pp.42-48
    • /
    • 2006
  • The number of confine-disease of elevator increases every year and then sudden rise, sudden stop, error of level indication, stand; those can bring to uneasiness of elevator passenger and malfunction accidents related life accident are increasing. For confirmation those malfunction accident, we are measuring and analyzing power quality(Sag, Swell, Interruption) of the actual site and evaluated the performance for stop and stating by testing the two imitation test equipment with EN12016(2004) standard level. This paper will be used data of the analysis for mutual relation between Power Quality and malfunction and fault of elevator.

Structural Performance Evaluation on Ended Block of Wide Flange PSC Girder for the Semi-Integral Bridges (광폭 플랜지 PSC 거더 단부 프리캐스트 블록을 활용한 반일체식교대교량의 구조성능 평가)

  • Ka, Hoon;Choi, Jin-Woo;Kim, Young-Ho;Park, Jong-Myen
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • Semi-integral abutment bridges are a type of integral abutment bridges. These bridges eliminate expansion joints on the structure and can be used in situations not suitable for full-integral abutment bridge. Moreover, Semi-integral bridges have excellent maintenance and can be economically constructed. This study is about precast wall-type blocks at each end which provide lateral support for PSC girder, as well as acting as retaining walls to resist longitudinal movement of semi-integral abutment bridge. The end-diaphragm connection between ended blocks of PSC girders can be achieved by in-suit nonshrinkage concrete. The results show that 3-point experiment of end-diaphragm beam have an acceptable performance which is so better than results of structural design. Moreover, the effects of backfill soil on semi-integral abutment bridge constructed are analyzed the behavior according to the temperature changes.

Splice Performance Evaluation of Fastening Coupler According to the Slope Length of Internal Fasteners (조임쇠 경사길이에 따른 체결식 커플러의 이음성능 평가)

  • Jung, Hyun-Suk;Choi, Chang-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.4
    • /
    • pp.11-19
    • /
    • 2022
  • In this study, in order to improve the splice performance of mechanical couplers, two new mechanical couplers with different connection modes were developed with rebar(SD400). The stress analysis of mechanical couplers with two different connection modes was carried out. Uniaxial tensile tests were carried out with type of steel, connection mode and the slope length of internal fastener as variables to analyze the influence on the maximum tensile strength. Building upon this previous work, the specimens that met the code in uniaxial tensile test were fabricated and static loading test and cyclic loading test were performed on the basis of Korean code(KS D 0249). The results of this research are as follows; (1) The tensile strength of steel and the slope length of internal fasteners have a certain influence on the maximum tensile strength. (2) The connection mode has some influence on the stiffness, slip and stiffness reduction rate of the connecting rebars. The results verify the feasibility of the proposed enhanced mechanical coupler in the field.

Development of the Portable Standard System for the Vehicle Detectors' Evaluation (차량검지기 성능평가를 위한 이동식 기준 장비 개발)

  • Lee, Sang Hyup;Baik, Nam Cheol;Heo, Woon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3D
    • /
    • pp.353-359
    • /
    • 2006
  • Image frame analysis is a conventional way of evaluating loop detector's performance. In image frame analysis, the time to evaluate performance is linearly proportional to the number of evaluated subjects, and the results can be subjective, depending on operator's personal evaluation standards and physical condition. Also, this method is often inferior in accuracy to that provided by the evaluated devices. Therefore, it is critical to develop a portable standard system which has better accuracy and more objectivity in evaluating vehicle detectors. This paper discusses function and reliability of tape-switch detector, which can be a replacement for image frame analysis, for effectively measuring traffic volume, speed, and occupancy.