• Title/Summary/Keyword: 현장압축강도

Search Result 536, Processing Time 0.029 seconds

A Study on the Engineering Characteristics of CLSM (유동성 채움재의 공학적 특성 연구)

  • Jung, Min-Ji;Jeon, Byeong-Won;Kim, Byeong-Jun
    • Journal of the Korean Geotechnical Society
    • /
    • v.40 no.2
    • /
    • pp.19-28
    • /
    • 2024
  • This study explores the long-term decline in the uniaxial compressive strength of Controlled Low Strength Material (CLSM) by preparing a sample with a 1:1 mixing ratio of CLSM and water. Uniaxial compressive strength tests were conducted after 7 and 28 days of curing. The results revealed that the compressive strength at 28 days was reduced by a factor of 2.85 compared to that at 7 days. Additionally, when expansion was introduced under the same mixing conditions, there was a significant reduction in compressive strength. Point load strength tests based on 7 and 28 days of curing indicated a disparity of 29.27 to 58.76 and 48.19 to 95.13 times, respectively, between the point load strength and the uniaxial compressive strength at 7 days. The differences observed in the findings of this study compared to previous studies may be attributed to variations in the precision of the test method and the sample production process. Therefore, it is essential to establish clear testing methods to accurately evaluate CLSM.

Development of Bentonite Composite Liners for Waste Landfill Sites (폐기물매립지 침출수 누출방지용 벤토나이트 복합라이너 개발)

  • Choi, Woo-Zin;Jin, Sung-Ki;Ha, Hun-Jung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.1 no.1
    • /
    • pp.65-70
    • /
    • 2000
  • Recently, soil-bentonite mixtures are frequently used as impervious liners for waste disposal sites. In the present work, bentonite composite liner systems have been developed by utilizing Korean zeolitic bentonites. The geomechanical properties of the liner systems, such as strength hydraulic conductivity, etc. have also been studied. The laboratory and field test results showed that uniaxial strengths of the system were improved by addition of bentonite and CaO-based additive to the upper and lower layer of the liner systems, respectively. Hydraulic conductivity values measured on field liner systems showed less $1{\times}10^{-3}cm/s$, which is considered to be minimum regulation requirement for waste disposal sites.

  • PDF

Strength Characteristics on High Strength Concrete against Sulfate Attack (황산염의 침해를 받는 고강도 콘크리트의 강도특성과 물성변화)

  • Park, Young-Shik;Suh, Jin-Kook;Lee, Jae-Hoon;Shin, Young-Shik
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.5
    • /
    • pp.117-128
    • /
    • 1998
  • 화학적으로 유해한 환경에 놓인 콘크리트 구조물은 필연적으로 그 기능이 악화되므로 혼화재를 포함한 고강도 콘크리트 또는 혼화재 그 자체가 화학물질에 오염된 환경하에서 어떤 변화를 일으키는가에 대한 연구의 필요성이 점점 증대되고 있다. 따라서 본 논문에서는 건설현장에서 가장 흔히 사용되는 보통강도 콘크리트와 실리카-흄을 포함한 포틀랜드시멘트 경화체인 고강도 콘크리트가 황산염의 침해를 받는 경우에 일어나는 강도특성과 물성변화를 조사하기 위하여 담수와 함께 황산나트륨, 황산마근네슘, 황산나트륨과 황산마그네슘의 혼합용액 등 여러종류의 황산염 용액에 실리카-흄을 사용한 고강도 콘크리트, 낮은 물-시멘트 비의 고강도 콘크리트, 보통강도의 콘크리트 등의 시험체들을 270일간 침지시켜 침지시간에 따른 압축강도 변화와 실리카-흄의 첨가량에 따른 압축강도 변화, 그리고 실리카-흄의 첨가량에 따른 선형팽창량 및 중량변화등에 관한 실험을 수행하였다. 이에 대한 실험결과를 토대로 실리카-흄을 사용한 고강도 콘크리트에 황산염이 미치는 영향을 분석하여 고강도 콘크리트의 실용성을 극대화하기 위한 방안에 대하여 고찰해보았다. 그 결과 실리카-흄을 포함한 고강도 콘크리트는 황산나트륨의 침해에 대해서는 강한 저항성을 나타내지만 황산마그네슘에 대해서는 심각한 침해를 일으키는 것으로 나타났으므로 황산마그네슘에 노출될 우려가 있는 콘크리트 구조물에 고강도를 발현하기 위하여 실리카-흄을 사용하는 것은 구조적으로 큰 문제가 발생할 것으로 사료된다.

A Study on Field Application of 150MPa Ultra Strength Surface-Exposed Concrete (150MPa급 초고강도 노출콘크리트의 현장적용에 관한 연구)

  • Kong, Tae-Woong;Lee, Soo-Hyung;Jang, Jae-Hwan;Lee, Han-Baek
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.989-992
    • /
    • 2008
  • In this paper, we are presenting a case that integrates ultra high strength concrete(150MPa) with surface-exposed concrete. Ahead of the field application, we carried out laboratory experiment and B/P Test for a basic property of concrete(slump flow, air content, 50cm flow time, elapse time change and compression strength) and productivity. The next, we conducted Mock-up Test using simulation specimen to evaluate infilling, surface-finishing and hydration heat of concrete. We had satisfactory results for a basic property and hydration heat of concrete. However at the time of field application, it was occurred rupture of formwork because of high lateral pressure of concrete, and then formwork was reinforced and case-in-place time was adjusted. And regardless of low and high frequency vibration, it occurred to surface-pockmark. In case that applies ultra high strength concrete to surface-exposed concrete, we estimate that it is important of systematic management and improvement of construction.

  • PDF

Field Mock up Test of High Strength Concrete for Busan Lotte Town (부산롯데타운용 고강도 콘크리트 현장 적용을 위한 Mock-up Test)

  • Moon, Hyung-Jae;Park, Soon-Jeon;Heo, Jin-Wook;Koo, Ja-Sul;Jeong, Youn-Sung;Lee, Yang-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.223-224
    • /
    • 2009
  • This study was performed to development 80MPa high strength concrete using local raw material of Busan and to estimate field application ability. As the result of three types of mixture, fresh and hardened properties were satisfied with target requirement properties. Hydration temperature was revealed mean 75$\sim$85$\circ$C. Additionally, in case of compressive strength, core specimen's strength is six times higher than field curing specimen by very high hydration heat.

  • PDF

Compressive Behavior of Reinforced Nylon Fiber Slag-CB (나일론 섬유 보강 Slag-CB의 압축거동 특성)

  • Younkyoung Lee;Taeyeon Kim;Jongkyu Lee;Youngsoo Joo;Bongjik Lee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.11
    • /
    • pp.5-10
    • /
    • 2023
  • Slag-CB is widely used in various fields that require groundwater control. It is a type of CB where a portion of the cement mixed with CB is replaced with GGBS. In general, Slag-CB has the advantage of long-term improvement in compressive strength, permeability, durability, and chemical resistance as the GGBS replacement ratio increases. However, there are problems such as decreased flexibility and resistance to deformation of the cut-off walls, as well as brittleness upon failure. To address these problems, some quality standards recommend designing Slag-CB with lower strength, which makes it challenging to apply high-strength Slag-CB with a high GGBS replacement ratio in the field.In this study, we aimed to improve the flexibility and resistance to deformation of Slag-CB to prevent brittle failure and improve the field applicability of Slag-CB. To achieve this, we evaluated the compressive behavior of nylon fiber-reinforced Slag-CB and proposed measures for enhancing the flexibility and resistance to deformation of Slag-CB.

A Study on the Suitability of CLSM Mixing Ratio Considering Dry Shrinkage (건조수축을 고려한 유동성 채움재 배합비 적합성에 관한 연구)

  • Jeon, Byeong-Won;Kim, Byeong-Jun
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.12
    • /
    • pp.7-17
    • /
    • 2022
  • The ratios of water and controlled low-strength materials (CLSM) were selected as 1:0.4, 1:0.6, 1:0.8, 1:1.0, and 1:1.2 to minimize the construction and long-term decrease in uniaxial compressive strength due to dry shrinkage through the combination of water, CLSM, and expansion agent. Approximately 2% and 5% of the expansion agent were added for each blending condition. As a result, it was found that the compressive strength decreased and the expandability increased as the specific gravity of the water increased. In addition, it was confirmed that the compressive strength increased rapidly up to 15 days of age compared to the CLSM used in the field. However, the compressive strength decreased compared to the 15 days of the age as of the 28 days of the age. It showed engineering characteristics similar to CLSM generally used in the field. Therefore, the water and the CLSM were mixed at a ratio of 1:0.8, and the field test was performed by adding 5% of an expansion agent. As a result, 28 days after age, the cavity waveform was observed using the handy GPR exploration system, and it was found that cavity waveform was relaxed or disappeared.

Pull-out Resistance Characteristics of the Anchor Bar According to the Grouting Material (주입재료에 따른 Anchor Bar의 인발저항 특성)

  • Yea, Geu-Guwen;Song, Young-Suk
    • The Journal of Engineering Geology
    • /
    • v.18 no.2
    • /
    • pp.227-232
    • /
    • 2008
  • In this study, the pull out resistance characteristics of an anchor bar to support a spillway installed in a slope are investigated by field tests. The injection materials were a cement mortar and cement milk. Unconfined compression strengths of those materials under several conditions were measured. As the result of compression test, the unconfined compression strengths of the cement mortar and the cement milk have positive proportional relation-ship with the water-cement ratio. They also have negative proportional relationship with increasing the curing time. In the same condition of water-cement ratio and curing time, the unconfined compression strength of cement milk is larger than that of cement mortar. In order to reduce the eccentricity in anchor bar during pull-out test in the field, the installation apparatus was improved by inserting a nut type of steel fixing coupling into the anchor bar. As the result of the pull-out test, the strength modification of cement milk was increased steeply at the early curing time. However, that of cement mortar was increased gradually with passing the curing time. Therefore, the cement milk has to use as the injection material for a prompt construction of anchor bar because the strength modification of cement milk is occurred at the early curing time.

The Characteristics of Compressive Strength in Mortar with Internal Curing According to Curing Condition (내부양생을 적용한 모르타르의 양생조건에 따른 압축강도 특성)

  • Kim, Joo-Hyung;Cho, Young-Keun;Lee, Kwang-Myong
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.2
    • /
    • pp.87-93
    • /
    • 2018
  • The use of high-strength concrete in construction have been increasing steadily. However, high-strength concrete has a low water-binder ratio, and the problems such as cracks due to hydration heat and shrinkage during the hydration process at the early age. Recently, as a method to reduce the shrinkage of concrete, study of internal curing has carried out according to increasing about interest about it. In this study, the effect of compressive strength on the curing condition(drying, moist, water) was investigated by using artificial lightweight aggregate(LWA) in high strength and high volume mortar. As a result of autogenous shrinkage, the effect of shrinkage reduction was enhanced depending on the increasing of LWA replacement. According to the curing condition, the results of compressive strength showed the different trend. The compressive strength has increased on the drying and moisture condition and decreased on the water condition.

The Study on the Correlation between Unconfined Compressive Strength and Point Load Strength within the Gneiss Complex in Gyunggi Province (경기 동부 지역 편마암복합체내의 일축압축강도와 점하중강도의 상관관계에 관한 연구)

  • Cha, Areum;Song, Joonho;Choi, Hyunseok;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.1
    • /
    • pp.21-26
    • /
    • 2007
  • The strength evaluation of rocks is a very important factor in designing and constructing tunnels or underground excavation. However, it takes a lot of time and endeavor to perform the unconfined compressive strength test for practice and a number of tests are limited. In order to make up for this method, the point load strength test is suggested. Generally, the strength of a rock differs depending on its type and region. However, as people unite the Point Load Strength Indexes of various regions and types to use in practice in many cases, they find difficulty in analogizing the exact strength. The purpose of this study is suggestion of the value in construction site by analizing the relation of both unconfined compressive and point load strength in the Gyeonggi gneiss complex.

  • PDF