• Title/Summary/Keyword: 현수장치

Search Result 239, Processing Time 0.025 seconds

Development of $^{169}Yb$ Low-Energy Sealed Source for Nondestructive Testing Applications Utilizing HANARO (하나로를 이용한 비파괴검사용 $^{169}Yb$ 저에너지 밀봉선원 개발)

  • Son, K.J.;Hong, S.B.;Jang, K.D.;Han, H.S.;Park, U.J.;Lee, J.S.;Seo, K.S.;Han, I.S.;Cho, W.K.;Lee, S.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.1
    • /
    • pp.25-32
    • /
    • 2008
  • [ $^{169}Yb$ ] industrial NDT sealed sources were developed by using $Yb_2O_3$ pellets as the target and demonstrated for their performance. To produce the pellets, optimal compacting and sintering conditions were determined experimentally. Source holders for $^{169}Yb$ were designed and fabricated. After assembling an active source produced from HANARO with the developed source holder, a demonstration experiment was performed to compare the quality of the radiographs from $^{192}Ir$ and soft X-rays. This demonstration study showed that the developed $^{169}Yb$ produced better radiographs than $^{192}Ir$ for a carbon steel with less than a 4 mm thickness.

OSEK OS Based Gateway for Interconnecting WAVE and CAN (WAVE와 CAN 연동을 위한 OSEK OS기반 게이트웨이)

  • Kim, Ju-Young;Seo, Hyun-Soo;Lee, Sang-Sun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39B no.2
    • /
    • pp.133-141
    • /
    • 2014
  • Recently, various services are provided by using WAVE protocol for communication among neighboring vehicles. And in order to operate stable system, the gateway for interconnecting in and out vehicle networks is required. In this paper, we propose gateway interconnecting WAVE and CAN protocol. The proposed gateway based on OSEK OS consists of a communication layer, a message translator layer and a message management layer. In the communication layer, WAVE communication part and CAN communication part are designed to communicate with WAVE and CAN. And in the message management layer, message management layer functions to store the received messages and check errors with the message. Based on these functions, experiment was conducted to analyze performance of the gateway with two scenarios such as transmitting periodically BSM as a message structure for safety services in vehicle-to-vehicle communications and responding to road side equipments requiring in-vehicle information. As a result of test, we verify our gateway performance by analyzing measured time in test scenarios.

Absorptive Separation of Sulfur Dioxide using Flat Membrane Contactor (평판형 분리막 접촉기를 이용한 이산화황 흡수 분리)

  • Lee Yong-Taek;Lee Young-Jin;Song In-Ho;Jeon Hyun-Soo;Ahn Hyo-Seong;Lee Hyung-Keun
    • Membrane Journal
    • /
    • v.16 no.3
    • /
    • pp.196-203
    • /
    • 2006
  • A flue gas emission known to cause an acid rain, containing sulfur dioxide, is tightly controlled by a regulation. The membrane contactor could be one of the alternatives which might be useful technologies for better performance of desulfurization. The fundamental sulfur dioxide separation data were obtained by a flat membrane contactor so that they could be utilized for the full scale membrane contactor. The separation of sulfur dioxide was measured in terms of the concentration of NaOH absorbent, the concentration of sulfur dioxide, the feed flow rate and different membrane materials. As the concentration of absorbent increased, the removal efficiency increased. By increasing the concentration of sulfur dioxide, the removal efficiency decreased. As the feed flow rate increased, it was observed that the removal efficiency decreased. Finally, the effect of the membrane material on separation was found to be negligible.

Seismic Response Control of Arch Structures using Semi-active TMD (준능동 TMD를 이용한 아치구조물의 지진응답제어)

  • Kang, Joo-Won;Kim, Gee-Cheol;Kim, Hyun-Su
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.1
    • /
    • pp.103-110
    • /
    • 2010
  • In this study, the possibility of seismic response control of semi-active tuned mass damper (TMD) for spatial structures has been investigated. To this end, an arch structure was used as an example structure because it has primary characteristics of spatial structures and it is a comparatively simple structure. A TMD and semi-active TMD were applied to the example arch structure and the seismic control performance of them were evaluated based on the numerical simulation. In order to regulate the damping force of the semi-active TMD, groundhook control algorithm, which is widely used for semi-active control, was used. El Centro (1940) and Northridge (1994) earthquakes and harmonic ground motion were used for performance evaluation of passive TMD and semi-active TMD. Based on the analytical results, the passive TMD could effectively reduce the seismic responses of the arch structure and it has been shown that the semi-active TMD more effectively decreased the dynamic responses of the arch structure compared to the passive TMD with respect to all the excitations used in this study.

  • PDF

Application of Smart Base Isolation System for Seismic Response Control of an Arch Structure (아치구조물의 지진응답제어를 위한 스마트 면진시스템의 적용)

  • Kang, Joo-Won;Kim, Hyun-Su
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.2
    • /
    • pp.157-165
    • /
    • 2011
  • Base isolation system is widely used for reduction of dynamic responses of structures subjected to seismic load. Recently, research on a smart base isolation system that can effectively reduce dynamic responses of the isolated structure without accompanying increases in base drifts has been actively conducted. In this study, a smart base isolation system was applied to an arch structure subjected to seismic excitation and its control performance for reduction of seismic responses was evaluated. In order to make a smart base isolation system, 4kN MR dampers and low damping elastomeric bearings were used. Seismic response control performance of the proposed smart base isolation system was compared to that of the optimally designed lead-rubber bearing(LRB) isolation system. To this end, an artificial ground motion developed based on KBC2009 design response spectrum was used as a seismic excitation. Fuzzy control algorithm was used to control MR damper in the smart base isolation system and multi-objective genetic algorithm was employed to optimize the fuzzy controller. Based on numerical simulation results, it has been shown that the smart base isolation system can drastically reduce base drifts and seismic responses of the example arch structure in comparison with LRB isolation system.

Use of Semi-active Tuned Mass Dampers for Vibration Control under Various Excitations (다양한 하중의 진동제어를 위한 준능동 TMD의 이용)

  • Kim, Hyun-Su;Kim, Seung-Jun;Lee, Dong-Guen
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.1 s.47
    • /
    • pp.51-62
    • /
    • 2006
  • To dale, lots of types of tuned mass dampers are developed and investigated to reduce dynamic responses of a structure due to various causes. In this study, control performance of semi-active tuned mass damper(STMD), that can change the damping of tuned mass damper in real time based on structural responses, was investigated with respect to various types of excitation employing numerical simulation. Skyhook control algorithm was used to appropriately modulate the damping ratio of semi-active damper that composes STMD. The control effectiveness of a STMD under harmonic and random excitation were evaluated using a single-degree-of-freedom (SDOF) structure in comparison with a conventional passive tuned mass damper (TMD). The robustness of a STMD and a passive TMD were compared along with the variation of the mass of a SDOF structure. The control performance of STMD using magnetorheological (MR) damper was also investigated in this study. Based on the numerical studios, it was shown that the control effectiveness of the STMD was significantly superior to that of a passive TMD with respect to harmonic and random excitation.

Vibration Control of High-rise Building Structures using Top-story Isolation Systems (최상층면진시스템을 활용한 고층건물의 진동제어)

  • Kim, Tae-Ho;Kim, Hyun-Su
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.5
    • /
    • pp.75-82
    • /
    • 2008
  • In this study, the possibility of vibration control of high-rise building structures by applying top-story isolation has been investigated. To this end, El Centro NS (1940) earthquake load is applied to 20- and 50-story building structures for numerical analysis. Artificial wind loads are used to evaluate the serviceability of example structures against wind vibration. As the number of isolated stories of example buildings is changed, structural responses has been evaluated to investigate optimal isolated building mass. And the natural period of isolation systems for top-story isolation is varied to investigate the improvement of control performance compared with the fixed base structure. Based on the analytical results, the top-story isolation system can be used as a hued mass damper and effectively reduce the structural responses of high-rise buildings against wind and seismic loads.

  • PDF

Implementation of FlexRay Communication Controller Protocol and its Application to a Robot System (FlexRay 프로토콜 설계 및 로봇 시스템 응용)

  • Kang, Hyun-Soo;Xu, Yi-Nan;Kim, Yong-Eun;Chung, Jin-Gyun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.6
    • /
    • pp.1-7
    • /
    • 2008
  • FlexRay is a new standard of network communication system which provides a high speed serial communication, time triggered bus and fault tolerant communication between electronic devices for future automotive applications. FlexRay communication controller (CC) is the core of the FlexRay protocol specification. In this paper, we first design the FlexRay CC protocol specification and function parts using SDL (Specification and Description Language). Then, the system is re-designed using Verilog HDL based on the SDL source. The FlexRay CC system was synthesized using Samsung $0.35\;{\mu}m$ technology. It is shown that the designed system can operate in the frequency range above 80 MHz. In addition, to show the validity of the designed FlexRay system the FlexRay system is combined with sound source localization system in Robot applications. The combined system is implemented using ALTERA Excalibur ARM EPXA4F672C3. It is shown that the implemented system operates successfully.

Noise Reduction of Electric Vehicle using Passive Damping Material (수동형 패치를 이용한 전기차 소음 저감)

  • Kim, Hyunsu;Kim, Byeongil;Han, Won-ok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.6
    • /
    • pp.117-122
    • /
    • 2017
  • Cabin noise due to the electric powertrain of electrical vehicle may consists of motor noise caused by electrical mismatch and gear noise coming from reduction gearbox. These sound may be considered rather small noise compared to those of internal combustion engine, but without masking effect, the noise can be more annoying for customer. Thus, this paper demonstrates the characteristics of electrical vehicle powertrain noise, and the effect of passive damping material for the noise reduction. The typical motor noise can be affected by the motor torque. Also, it is demonstrated that the reduction gearbox may be a weak point for the noise path compared to the motor housing. With vehicle test, it is shown that the damping patch is more effective for noise reduction with deceleration condition than with acceleration condition.

Seismic Response Evaluation of Mid-Story Isolation System According to the Change of Characteristics of the Seismic Isolation Device (면진장치 특성 변화에 따른 중간층 면진시스템의 지진응답 평가)

  • Kim, Hyun-Su;Kim, Su-Geun;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.1
    • /
    • pp.109-116
    • /
    • 2018
  • As the number of high-rise buildings increases, a mid-story isolation system has been proposed for high-rise buildings. Due to structural problems, an appropriate isolation layer displacement is required for an isolation system. In this study, the mid-story isolation system was designed and the seismic response of the structure was investigated by varying the yield strength and the horizontal stiffness of the seismic isolation system. To do this, a model with an isolation layer at the bottom of $15^{th}$ floor of a 20-story building was used as an example structure. Kobe(1995) and Nihonkai-Chubu(1983) earthquake are used as earthquake excitations. The yield strength and the horizontal stiffness of the seismic isolation system were varied to determine the seismic displacement and the story drift ratio of the structure. Based on the analytical results, as the yield strength and horizontal stiffness increase, the displacement of the isolation layer decreases. The story drift ratio decreases and then increases. The displacement of the isolation layer and the story drift ratio are inversely proportional. Increasing the displacement of the isolation layer to reduce the story drift ratio can cause the structure to become unstable. Therefore, an engineer should choose the appropriate yield strength and horizontal stiffness in consideration of the safety and efficiency of the structure when a mid-story isolation system for a high-rise building is designed.