• Title/Summary/Keyword: 현수장치

Search Result 239, Processing Time 0.028 seconds

Dose modeling and its Application of Ir-192 for substitution of Ralstron Brachytherapy source (Ralstron 선원대체형 Iridium-192 선원의 선량모델링과 응용)

  • 김옥배;최태진;김진희;이호준;박정호;김성규;조운갑;한현수
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.131-139
    • /
    • 2000
  • We designed high dose rate Ir-192 source which was prepared for substitute the Co-60 source in Ralstron unit (Simatsu, Japan) which is supplied for cervical cancer treatment. The source dimension is 1.5 mm in a diameter and 1.5mm thickness of cylinder and encapsulated with 3 mm diameter of stainless steel(SUS316L) to substituted for the Co-60 source size. The Ir-192 source was prepared the dose model for tissue dose computation through the experimental determination of apparent activity and applied the empirical tissue correction factors extended to 20cm distance. The tissue dose model was applied the 4.69 R/cm-mCi-hr gamma constant and the ratio of energy absorption coefficient of water to that of air showed 1.112 include filteration of the self-absorptions. In this experiments, we prepared the dose computation software to clinical usefulness.

  • PDF

The Effects of Task Oriented Training with Suspension Device on Trunk Stability and Gross Motor Function of Children with Spastic Diplegia Cerebral Palsy (현수보조장치를 이용한 과제 지향적 훈련이 경직형 양하지 뇌성마비아동의 체간 안정성과 대동작기능에 미치는 영향)

  • Lee, Mi-Seon;Choi, Jong-Duk
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.8 no.4
    • /
    • pp.637-645
    • /
    • 2013
  • PURPOSE: The purpose of this study was to examine the effect of using a suspension device for arm reaching activity on trunk stability and gross motor function of children with spastic diplegia cerebral palsy. METHODS: The subject in this study consisted of 11, GMFCS(Gross Motor Function Classification System) III~IV children with spastic diplegia cerebral palsy, all of whom agreed to participate in the study. All subjects were divided into two groups: the experimental group using a suspension device, and the control group using no suspension device. For each group, a thirty-minute intervention was done twice per week during 8 weeks. Before and after intervention, each test was measured using TIS(Trunk Impairment Scale), GMFM (Gross Motor Function Measure) and PRT(Pediatric Reaching Test) to change trunk stability, gross motor function and arm reaching activity. The data were analyzed with the Wilcoxon signed rank test. RESULT: All two groups had a meaningful increase in GMFM-Sit data measured before and after intervention. The experimental group had a significant increase from an average of 78.83 to an average of 84.83 in GMFM-Crawling. For both groups, there was a substantial increase in the change in sitting position and arm reaching. CONCLUSION: According to the results of this study, the arm reaching activity using suspension device had an effect on trunk stability and gross motor function and it changed arm reaching activity.

An Analysis for Reduction Method of Head loss at Manholes with a $90^{\circ}$ Bend ($90^{\circ}$ 접합맨홀에서의 에너지손실 저감 방법 분석)

  • Kim, Jung-Soo;Choi, Hyun-Soo;Yoon, Sei-Eui
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.395-399
    • /
    • 2009
  • 현재 계획 또는 설계단계에서 수행되고 있는 우수 관거 시스템의 수리계산에서는 연결관의 마찰손실만을 감안하여 수행하고 있으며, 맨홀에서의 수두손실은 고려되지 않는 실정이다. 특히 과부하 $90^{\circ}$ 접합맨홀 내부에서의 복잡한 흐름 현상에 의하여 발생하는 에너지 손실은 일반적인 직선 연결 맨홀에 의해서 발생하는 에너지 손실과 큰 차이를 보이지만 현재 우수 관거 설계 및 관리에서는 이를 대부분 고려하지 않는 실정이다. 또한 직선으로 연결된 맨홀보다 $90^{\circ}$ 접합 맨홀은 유수교란에 의한 에너지 손실이 커지므로 이에 대한 $90^{\circ}$ 접합 맨홀에서의 에너지 손실 저감에 대한 연구가 필요하다. 그러므로 본 연구에서는 합류 맨홀 중 $90^{\circ}$ 접합 맨홀에서의 에너지 손실 저감 방법의 분석을 위하여 하수도시설기준(환경부, 2005)의 표준 1호(원형), 특 1호(사각형) 맨홀을 각각 축소 제작하고, 수리실험 장치를 제작하여 수리 실험을 실시하였으며, 실험결과를 benching을 사용하지 않은 $90^{\circ}$ 접합 맨홀의 평균 손실계수를 산정한 윤세의 등(2008)의 실험 결과와 비교하였다. 접합위치를 변경한 원형 맨홀 CASE B에서의 평균 손실계수는 1.1로 산정되어 CASE A의 1.6보다 크게 감소하였다. 접합위치를 변경한 사각형 맨홀 CASE B에서는 1.5로 산정되어 손실계수의 감소폭이 적었으나, 접합위치를 변경하고 side benching을 설치한 CASE C에서의 평균 손실계수는 1.1로 산정되어 CASE A의 사각형 맨홀의 손실계수 1.6에 비하여 큰 감소 효과를 나타내었다. 따라서 $90^{\circ}$ 접합 원형 맨홀에서는 접합 위치를 변경시킨 CASE B의 형태를 사용하고, 사각형 맨홀에서는 접합 위치를 변경시키고 side benching을 설치한 CASE C의 형태를 사용하면 우수 관거 시설의 배수능력을 향상 시킬 수 있을 것으로 판단된다.

  • PDF

Development of Emotion Inference Application with Location Information and User's Heartbeat Rate (심박 정보 기반 위치 정보 융합형 감정 추론 어플리케이션 개발)

  • Cha, Kyung-Ae;Choi, Hyun-Su;Hong, Won-Kee;Park, Se Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.8
    • /
    • pp.83-88
    • /
    • 2017
  • The personal activity information is expanding as a way to utilize wearable devices that are emerging as next generation smart devices. This paper develops an application for collecting heartbeat rate and location information of a user using SmartWatch, which is a smartphone and wearable device, and analyzing it through machine learning to infer user's emotion information. By using smart phone and smart watch, developed application can collect biometric data and location information by simply executing application and doing everyday life. In addition, adding the location information to the hearbit rate data, it proves higher utilization than existing ones.

Theoretical Analysis on a Liquid-Liquid Static Extractor Using Highly Packed Fiber Bundle (고밀집 섬유 집합체를 이용한 정적 액-액 추출 장치의 이론적 해석)

  • Kim, Kwang-Wook;Byeon, Kee-Hoh;Lee, Eil-Hee;Yoo, Jae-Hyung;Park, Hyun-Soo
    • Applied Chemistry for Engineering
    • /
    • v.8 no.3
    • /
    • pp.416-424
    • /
    • 1997
  • Mass transfer mechanism and concentration profiles in the axial direction at each phase were analyzed and simulated by a theoretical modeling on a liquid-liquid static contactor using highly packed fiber bundle. The concentrations at the end of the fiber extractor calculated at several operational conditions were compared with experimental results. The fiber extractor could be completely predicted by a plug flow model without axial dispersion. A parameter used in the model equations, $k_a{\sigma}$ called the product of mass transfer coefficient and mass transfer area per unit length of the fiber extractor in the axial direction, which was determined by a curve-fitting, was confirmed to be a unique characteristic value of the fiber extractor, and was about 0.0327cm2/sec.

  • PDF

Performance Evaluation of Vibration Control of High-rise Buildings Connected by Sky-Bridge (스카이브릿지로 연결된 고층건물의 진동제어 성능평가)

  • Kim, Hyun-Su;Yang, Ah-Ram;Lee, Dong-Guen;Ahn, Sang-Kyung;Oh, Jung-Keun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.4
    • /
    • pp.91-100
    • /
    • 2008
  • In this study, the vibration control performance of high-rise building structures connected by a sky-bridge has been investigated. The philosophy of vibration control using sky-bridges is to allow structures with different dynamic characteristics to exert control forces upon one another through sky-bridges to reduce the overall responses of the system. The the high-rise building structure connected by sky-bridge with 49 and 42 stories was used in this study to investigate the displacement, acceleration, reaction of bearings and stress of sky-bridge by analytical methods. To this end, historical earthquakes, an artificial earthquake and wind force time histories obtained from wind tunnel tests were used. Based on the analytial results, the use of sky-bridge can be effective in reducing the structural responses of high-rise buildings against wind and seismic loads.

  • PDF

A Study on the Contact Seam Tracking Sensor by Using Strain Gauges (스트레인 게이지를 이용한 접촉식 용접선 추적 센서에 관한 연구)

  • 안병원;배철오;김현수
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.5
    • /
    • pp.1019-1025
    • /
    • 2003
  • There are many kinds of seam trackers in the industrial welding field. We are proposed the contact seam tracking sensor applying strain gauges kind of contact sensor that mostly used in welding part now. For this seam tracking experiment, we made the strain gauges sensor by ourselves and tested how well the sensor tracks the seam. The experiment device consist of strain gauges sensor, amplifier circuit of strain gauges signal, saw wave generator, MOSFET power diving circuit and X-Y slide by moved DC motor. The tracking areas are X-Y planes(left, right, up and down) and the change of strain gauge resistance causes to move DC motor that connected to X-Y slide. As a result of experiment, we confirmed that the strain gauges sensor tracks a seam well, and X-Y slide DC motor was controlled by PWM control.

A Study on the Reduction of the Sloshing of Storage Tank Using Wing and Diaphragm Baffle (날개형 및 격막형 배플을 이용한 유체저장탱크 내부의 슬로싱 저감 연구)

  • Lee, Young-Shin;Kim, Hyun-Soo;Lee, Jae-Hyung;Kim, Young-Wann;Ko, Sung-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.12
    • /
    • pp.2039-2046
    • /
    • 2003
  • Storage tank filled with fluid has unique dynamic characteristics compared to general structures, due to the interaction between fluid and structure. The oscillation of the fluid surface caused by external forces is called sloshing, which occurs in moving vehicles with contained liquid masses, such as trucks, railroad cars, aircrafts, and liquid missles. In this study, the evaluation method for the reduction of sloshing, the optimized size and location of wing and diaphragm baffles are suggested based on the experimental results. The experimental device can simulate the translation motion. A rectangular tank and various baffles are fabricated to study on the sloshing characteristics. The forces measured using the load cell at tank wall and those are compared with each other through the Fourier transformation for various conditions. The study of the sloshing of the rectangular tank equipped with baffles is conducted under the same conditions with non-baffled rectangular tank experiment. From the experimental results, the sloshing reduction effect by the baffles is observed. In conclusion in case of diaphragm baffles, the optimized size ratio of the width of baffle to the water height is 0.44 and the installation location has no effect to the damping of sloshing. In case of wing baffles, the optimized size ratio of the width of baffle to the length of a rectangular tank is 0.1 and the optimized location ratio of the baffle to the water height is 0.9.

A Development of the Starting Motor for Packaged Power Systems (이동식 발전설비용 시동전동기 개발)

  • Kim, Jong-Su;Kim, Seung-Hwan;Oh, Sae-Gin;Kim, Yong-Geun;Kim, Hyun-Su
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.1
    • /
    • pp.172-178
    • /
    • 2012
  • Packaged power systems are very convenient for transferring and installing, and can supply electric power steadily for the areas which have a great difficulty in drawing power line from the outside. Then, the equipments have been widely used in such mountain areas and the back of beyond. Generally, compressed air has been employed to start the dynamo-engines for P.P.S. However, these systems necessitate air compressors, air tanks, air starting motors and pipe lines for transferring compressed air etc. Recently, starting systems which have only batteries and series DC motors as whole automobiles have been applied due to their simplicity and economy. In this paper, developed new starting motor for the P.P.S. And we achieved the better results from performance tests.: Output power, torque and speed.

Precise Adsorption Measurement Technique by a Phase Modulated Ellipsometry (편광변조 타원해석법에 의한 정밀 흡착측정기술)

  • Choi, B.I.;Nham, H.S.;Park, N.S.;Youn, H.S.;Lim, Tong-Kun
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.6
    • /
    • pp.531-538
    • /
    • 2004
  • Studies of adsorption isotherms with sharp step-wise layer condensation help us to better understanding of two dimensional layers. For this, an adsorption isotherm apparatus, using a phase modulated ellipsometric technique, has been constructed and an adsorption experiment has been performed. With subatomic scale resolution(∼0.3 $\AA$), the adsorption processes could be observed by ellipsometric signals. On measurement of multilayer adsorption of argon on highly oriented pyrolytic graphite(HOPG), thousands of adsorbed layers were observed at 34.04 K, which suggests that the adsorption is completely wet. On the contrary nine sharp layers of steps for adsorptions and desorptions were observed at 67.05 K. These isotherms obtained can provide a lot of information about thermodynamic states, bonding energies between adsobate and substrate, and structure transitions in the adsorbed film.