• Title/Summary/Keyword: 현수장치

Search Result 239, Processing Time 0.023 seconds

A Study on the Reliability of District Heat Measuring Devices for Ground Source Heat Pump Systems (지열원 히트펌프 시스템에 적용되고 있는 난방용 적산열량계의 신뢰성 평가에 관한 연구)

  • Kang, Hee Jeong;Lee, Hyun Su;Jang, Myung Hun
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.14 no.1
    • /
    • pp.1-7
    • /
    • 2018
  • A ground source heat pump system should be equipped with devices to measure the generated heating or cooling heat amount in Korea. Generally, the heat measuring devices have been developed to estimate consumed heat amount in residential or commercial buildings from a central air-conditioning system or a district heating system. In this study, two representive heat measuring devices used for buildings were selected, and the accuracy of them were experimentally estimated at the ground source heat pump operating conditions. The obtained heat amounts from the heat measuring devices were deviated within 4.3% comparing with the precise values calculated from an accredited test facility. Even though the accumulated heat amount values of the heat measuring devices had a small difference comparing with the precise values, the temperatures of heat measuring devices showed greatly different values comparing with the precise temperature. Therefore, it is highly recommended to develop the heat measuring devices which is appropriate for the ground source heat pump systems.

R&D Status of Na/NiCl2 Battery (Na/NiCl2 전지의 연구 개발 동향)

  • Kim, Hyun-Soo;Lee, Sang-Min
    • Journal of the Korean Electrochemical Society
    • /
    • v.15 no.3
    • /
    • pp.124-134
    • /
    • 2012
  • Environmental concerns over the use of fossil fuels and their resource constraints have spurred increasing interest of renewable energy, and the needs for energy storage from the renewable resources is getting rapidly increase. Na/$NiCl_2$ cell could be use electric vehicles as well as energy storage, because it has a high energy-efficiency, environmental-friendly, low cost. However, there remain several issues on improvement of materials, component, cell design, and process, to use in broad applications and to penetrate to market. This paper offers a comprehensive review on R&D status of the structure, chemistry, key materials, and cell design & manufacture for Na/$NiCl_2$ cells.

A Development of V type Suspension String Set for UHV Transmission Lines (초고압 송전선로용 V련 현수애자장치의 개발)

  • Sohn H. K.;Lee H. K.;Keum E. Y.;Min B. W.;Choi J. S.;Choi I. H.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.497-499
    • /
    • 2004
  • Due to a typhoon named MAEMI on Sep12, 2004, 7 transmission towers collapsed and 3 were damaged in the Gyeongnam and Busan areas. These caused long-term black-outs in Goeje-do. When a transmission tower collapses or is damaged, Construction will take more than 2 months and this will be accompanied by long-term black-outs. Therefore a temporary iron pole is used in such emergencies. Current temporary rehabilitation angle steel iron Pole consistes of around 800 members, 2,800 bolts and it takes about 5 days to construct a temporary transmission line. Consiquently wide black-outs occur during the construction of the temporary transmission line. To reduce black-out time, the construction period must be reduced as much as possible. This paper presents new methods to reduce temporary transmission line construction time to within 48 hours by applying a self-reliance assembling method instead of the current man power assembling method and by modulizing each angle steel with duralumin.

  • PDF

Power Transmission Characteristics of a Hydro-Mechanical Transmission (정유압 기계식 변속장치의 동력전달특성)

  • Seong, Deok-Hwan;Kim, Hyeong-Ui;Lee, Geun-Ho;Kim, Hyeon-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.11
    • /
    • pp.1854-1862
    • /
    • 2001
  • In this paper, power flow characteristics of a hydromechanical transmission(HMT) are investigated using network analysis. The HMT used in this study consist of a hydrostatic unit(HSU), planetary gear sets, clutches and brakes providing forward 4 speeds and backward 2 speeds. Since the HMT power flows showing a closed loop and the HSU efficiency varies depending on the pressure and speed, a systematic approach is required to analyze the power transmission characteristics of the HMT. In order to analyze the closed loop power flow and the HSU power loss which changes depending on the pressure and speed, network model is constructed fur each speed range. In addition, an algorithm is proposed to calculate an accurate HSU loss corresponding to the experimental results. It is found from the network analysis that the torque and speed of each transmission element including the HSU can be obtained as well as direction of the power flow by the proposed algorithm. It is expected that the network analysis can be used in the design of relatively complicated transmission system such as HMT.

Design and evaluation of light source for photodynamic diagnosis of cancer (광역학적 암진단을 위한 광원장치의 설계 및 평가)

  • Lim, Hyun-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.73-76
    • /
    • 2007
  • Photodynamic diagnosis(PDD) is a method to diagnose the possibility of cancer, both by the principle that if a photosensitizer is injected into an organic tissue, it is accumulated in the tissue of a malignant tumor selectively after a specific period, and by a comparison of the intensity of the fluorescence of normal tissue with abnormal tissue after investigating the excitation light of a tissue with accumulated photosensitizer. Since the selection of the wavelength band of excitation light has an interrelation with fluorescence generation according to the selection of a photosencitizer, it plays an important role in POD. This study aims at designing and evaluating light source devices that can stably generate light with various kinds of wavelengths In order to make possible PDD using a photosensitizer and diagnosis using auto-fluorescence. The light source device was a Xenon lamp and filter wheel, composed of an optical output control through Iris and filters with several wavelength bands It also makes the inducement of auto-fluorescence possible because it is designed to generate a wavelength band of 380-400. The transmission part of the light source was, developed to enhance the efficiency of light transmission. To evaluate this light source device, the characteristics of the light output and wavelength band were verified. To validate the capability of this device as PDD the detection of auto-fluorescence using mouse was performed.

  • PDF

A Study on the Automatic Fuel-Filling-Recognition system for a city bus (자동인식 주유량 처리 시스템에 관한 연구)

  • 김현수;안병원;박중순;박영산;배철오;김철홍
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.414-417
    • /
    • 2001
  • In this paper the fuel filling system for a city bus was investigated in order to improve the system. The suggested fuel filling system was designed to have functions of identifying a bus arrival tine, and measuring volume of fuel filled. The system consisted of four parts of bus identification, IBM PC, interface card, fuel filling control system and program for integrating all parts. It is believed that the information obtained by this system can be used for analysing driver's driving habits and performance of engine of a bus, and accordingly the prime cost can be reduced.

  • PDF

Physicians' Requirement Analysis Based Design of the Master Device Mechanism for Teleoperated Interventional Robotic System (원격 중재시술용 마스터장치에 대한 의료진 요구분석 및 이를 반영한 메커니즘 설계)

  • Woo, Hyun Soo;Cho, Jang Ho;Lee, Hyuk Jin
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.8
    • /
    • pp.603-609
    • /
    • 2016
  • This paper presents an optimally designed master device mechanism for teleoperated interventional robotic system. The interventional procedures using the teleoperated robotic system and the physicians' requirements are summarized. The master device should implement 5-DOF motion including 2-DOF translational motion for the entry position control, 2-DOF rotational motion for the orientation control, and 1- DOF translational motion for needle insertion. The handle assembly includes a 1-DOF translational mechanism for needle insertion and buttons for operation mode selection. The mechanisms for the 2-DOF translational motion and the 2-DOF rotational motion are designed using motors and brakes based on the various mechanisms to satisfy all the above requirements, respectively. Absolute position sensors are adopted to implement automatic initial positioning and orientation matching at the first step of needle insertion.

A Review on e-pedigree for Strengthening Global Supply Chain Management (글로벌 SCM 강화를 위한 e-pedigree에 대한 고찰)

  • Seo, Dong-Min;Han, Dae-Hee;Choi, Yong-Jung;Jung, Hae-June;Kim, Hyun-Soo
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2010.07a
    • /
    • pp.361-364
    • /
    • 2010
  • 글로벌 시장환경체제에서 유통구조가 복잡해짐에 따라 제조사에서 유통업체 및 소비자까지 아우르는 전체 공급망에서 제품에 대한 이력추적관리는 투명한 유통구조를 형성시킬 뿐만 아니라 더 나아가 소비자들의 안전에 지대한 영향을 미친다. 세계보건기구(WHO)에 따르면 선진국에서 부정 전문의약품의 유통비중은 전체 의약품의 1% 정도이며 이를 미국에 적용할 경우(2006년 기준), 미국에서 유통된 34억 개 전문의약품 중 3,400만 개의 전문의약품이 가짜일 가능성이 있는 것으로 보고되고 있다. 이로 인해 미국 캘리포니아주에서는 유통망의 투명성과 소비자의 안전을 보고하기 위하여 2D 바코드나 RFID(Radio Frequency IDentification)를 통해 의약품 제조에서 약국까지의 유통과정 계보를 추적할 수 있도록 제약기업에 2015년부터 제품에 시리얼번호를 부착한 이력장치(serialized e-pedigree)를 시행할 예정이다. 따라서 본 연구에서는 국내 외적으로 물류/유통과정에서 제품의 위 변조를 예방하기 위한 e-pedigree에 현황 및 동태를 파악하고 국내 e-pedigree에 대한 방향성을 고찰하는데 그 목적이 있다.

  • PDF

Power Characteristics Analysis of Hydro-Mechanical Transmission (정유압기계식 변속장치의 동력특성해석)

  • Sung, Duk-Hwan;Lee, Geun-Ho;Kim, Hyun-Soo
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.519-524
    • /
    • 2001
  • In this paper, power flow characteristics of a hydromechanical transmission(HMT) are investigated using network analysis. The HMT used in this study consist of a hydrostatic unit(HSU), planetary gear sets, clutches and brakes providing forward 4 speeds and backward 2 speeds. Since the HMT power flows showing a closed loop and the HSU efficiency varies depending on the pressure and speed, a systematic approach is required to analyze the power transmission characteristics of the HMT. In order to analyze the closed loop power flow and the HSU power loss which changes depending on the pressure and speed, network model is constructed for each speed range. In addition, an algorithm is proposed to calculate an accurate HSU loss corresponding to the experimental results. It is found from the network analysis that the torque and speed of each transmission element including the HSU can be obtained as well as direction of the power flow by the proposed algorithm. It is expected that the network analysis can be used in the design of relatively complicated transmission system such as HMT.

  • PDF

The Study on Scattered Ray by C-arm in Operation Room (수술실 내 C-arm 장치의 산란선 분포에 대한 연구)

  • Park, Seung-Hyun;Park, Joo-Mi;Kim, Hyun-Soo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.1
    • /
    • pp.21-26
    • /
    • 2011
  • A radiation imaging system used in a surgery room is mainly using C-arm which is purposed to fluoroscope. C-arm is often use to watch an operation's accuracy and progress, but not only being bombed to this first beam but also affected to this scattered beam, so now we are look for the way to reduce bombed amount of doctor, nurses and radiological technologists. We measured the exposure dose in $0^{\circ}$ spot according to the distance to find out frequency distribution of scattered ray in an operation room and found the spot which has the same exposure dose from $30^{\circ}$ distance of all directions and wrote isodose curve. We analyzed the data and found out the sudden reduction of scattered ray according to the long direction also found out that scattered ray was not related to the directions. Operators must recognize the reduction of exposure dose. Because reducing scattered ray from all directions in an operation room is really difficult. So every operators must use shelters to reduce the exposure dose and notice the safety.

  • PDF