• Title/Summary/Keyword: 허용용적률

Search Result 5, Processing Time 0.017 seconds

The Improvement of Design Inducement Incentive on Permitted Floor Area Ratio in District Detailed Plan -Focused on the Design Inducement Incentive items and parameters in formula- (서울시 지구단위계획 구역내 건축물의 계획유도를 위한 허용용적률 인센티브 개선방안 - 항목 및 세부계획기준의 계수를 중심으로)

  • Rim, Eun Young;Lee, Seung Joo
    • KIEAE Journal
    • /
    • v.17 no.4
    • /
    • pp.49-57
    • /
    • 2017
  • Purpose: Design inducement incentive item and formula on permitted floor area ratio in district detailed plan have been improved to reflect the actual application of guidelines and the social needs of city and architecture. However, the current guideline has a limit to realize the purpose of the plan. This study proposes improvement of the items and parameters in formula. Method: This study analyzed the district detailed planning guidelines since 2000 and the cases of general type district unit plan. In order to propose improved items and parameters, planing purposes and present parameters were compared and analyzed. Result: Items of guidelines have been changed according to public needs. High necessity items were applied to large parameters, and these items have been changed as the guideline changes. Diversity of items depended on regional characteristics, and parameters were more flexible than items for most cases. The purposes of plans, parameters and items were analyzed and it revealed four items needed improvement; the inducement of the limited building line, the improvement of the pedestrian and street environment, the necessity of the open space, and strengthening of the regional agreement. For improvement, this study added items and improved the relevance between items and sub-items. The parameters were improved by considering the importance, feasibility and comparing them with each other. Simulated result confirmed that proposed guideline is appropriate to operate, and also characteristics of area encourage to operate it more flexible.

대한건축사협회 회관 신축 현상설계

  • Korea Institute of Registered Architects
    • Korean Architects
    • /
    • no.1 s.417
    • /
    • pp.94-122
    • /
    • 2004
  • 우리협회 회관의 노후로 인한 업무환경의 개선과 미래지향적이고 건축사들의 위상과 긍지를 높일 수 있는 회관을 확보함으로써 대외적 이미지를 높이는데 기여함은 물론 협회재정의 자립기반을 조성하는데 기여할 건축사들의 회관을 건립하고자 2003년도 제1회 임시총회(03.6.20)에서 현 부지에 회관을 신축키로 의결하였다. 이에 지난 2003년 10월 21일 현 건축사협회 부지에 건폐율 60%, 용적률 300%이내, 연면적 11,000㎡[허용범위±15%] 조건으로 회관건립을 위한 현상설계공모 공고를 냈다. 총 76개사에서 응모신청을 받아 최종 20개사 작품이 응모된 결과 최종심사를 거쳐 당선작 없이 우수작 1점, 가작 1점, 입선작 5점 등 총 7개 작품이 선정됐다.

  • PDF

The Accuracy Evaluation according to Dose Delivery Interruption and Restart for Volumetric Modulated Arc Therapy (용적변조회전 방사선치료에서 선량전달의 중단 및 재시작에 따른 정확성 평가)

  • Lee, Dong Hyung;Bae, Sun Myung;Kwak, Jung Won;Kang, Tae Young;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.77-85
    • /
    • 2013
  • Purpose: The accurate movement of gantry rotation, collimator and correct application of dose rate are very important to approach the successful performance of Volumetric Modulated Arc Therapy (VMAT), because it is tightly interlocked with a complex treatment plan. The interruption and restart of dose delivery, however, are able to occur on treatment by various factors of a treatment machine and treatment plan. If unexpected problems of a treat machine or a patient interrupt the VMAT, the movement of treatment machine for delivering the remaining dose will be restarted at the start point. In this investigation, We would like to know the effect of interruptions and restart regarding dose delivery at VMAT. Materials and Methods: Treatment plans of 10 patients who had been treated at our center were used to measure and compare the dose distribution of each VMAT after converting to a form of digital image and communications in Medicine (DICOM) with treatment planning system (Eclipse V 10.0, Varian, USA). We selected the 6 MV photon energy of Trilogy (Varian, USA) and used OmniPro I'mRT system (V 1.7b, IBA dosimetry, Germany) to analyze the data that were acquired through this measurement with two types of interruptions four times for each case. The door interlock and the beam-off were used to stop and then to restart the dose delivery of VMAT. The gamma index in OmniPro I'mRT system and T-test in Microsoft Excel 2007 were used to evaluate the result of this investigation. Results: The deviations of average gamma index in cases with door interlock, beam-off and without interruption on VMAT are 0.141, 0.128 and 0.1. The standard deviations of acquired gamma values are 0.099, 0.091, 0.071 and The maximum gamma value in each case is 0.413, 0.379, 0.286, respectively. This analysis has a 95-percent confidence level and the P-value of T-test is under 0.05. Gamma pass rate (3%, 3 mm) is acceptable in all of measurements. Conclusion: As a result, We could make sure that the interruption of this investgation are not enough to seriously affect dose delivery of VMAT by analyzing the measured data. But this investigation did not reflect all cases about interruptions and errors regarding the movement of a gantry rotation, collimator and patient So, We should continuously maintain a treatment machine and program to deliver the accurate dose when we perform the VMAT for the many kinds of cancer patients.

  • PDF

The Evaluation of Hybrid-Volumetric Modulated Arc Therapy for Lung Cancer Radiation Therapy (폐암 방사선 치료 시 Hybrid-Volumetric Modulated Arc Therapy의 유용성 평가)

  • Lee, Geon Ho;Kang, Hyo Seok;Choi, Byoung Joon;Park, Sang Jun;Jung, Da Ee;Lee, Du Sang;Ahn, Min Woo;Jeon, Myeong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.19-26
    • /
    • 2017
  • Objectives: In the Lung, the VMAT rotates continuously and examines radiation. That increases the low doses to normal lung. Due to that, the incidence of radiation pneumonia among radiation side effects may increase. The cause of radiation pneumonia is the lower dose area of the lungs. The H-VMAT was applied to patients who applied to reduce radiation in the lower doses of the lungs. We wanted to assess the usefulness of the H-VMAT by comparing the radiation doses to the low dose areas of the lungs and the normal organs. Materials and Methods: A total of 26 patients who applied for a H-VMAT procedure were applied to the patient. The prescription dose applied to total dose 44 Gy from 22 divisions. For each patient, a plan was implemented with Conventional RT, VMAT and H-VMAT. Conventional RT was carried out in four to five fields each, considering the size, location, shape, and location of the PTV. In the case of a VMAT plan, the two Half ARC, three Half ARC method and the two Full ARC were planned. The H-VMAT was planned by adding two Static fields in the VMAT, taking into account the dose of the lung and the tolerance dose of the organs. Results: In the NSCLC, the lung doses $V_5$ and $V_{10}$ of the lungs except for the treatment plan volume were the lowest with $55.40{\pm}13.39%$ and $32.05{\pm}11.37%$ of H-VMAT. And, in the SCLC, the lung doses of V5 and V10 were the lowest at $64.32{\pm}16.15%$ and $35.50{\pm}9.91%$, respectively. The spinal dose of VMAT in NSCLC was $21.15{\pm}4.02Gy$, which was 7.94 Gy lower than other treatment methods. The lowest spinal dose was delivered at $19.72{\pm}1.82Gy$ for SCLC. The mean dose delivered to the esophagus was also $17.44{\pm}2.04Gy$ and $17.84{\pm}9.20Gy$ in SCLC and NSCLC, respectively. Conclusion: When comparing the value of the surrounding normal organ dose, the VMAT showed that less doses were transmitted from the heart, esophagus and spinal cord than the rest of the treatment plan. However, it was similar to VMAT in normal organs except for the spinal cord. VMAT has increased doses of some normal organs but did not exceed the tolerance dose. It showed a low value in $V_5$, $V_{10}$. When comparing Conventional RT, VMAT, and H-VMAT, If the dose to the heart, esophagus and spinal cord is lower than the tolerance dose, it is thought to reduce the incidence of radiation pneumonia by applying H-VMAT that show the benefits of low doses of the lungs.

  • PDF

A Study on the Story Increase for Securing the Feasibility of Aged-Housing Remodeling (노후공동주택 리모델링의 사업성 확보를 위한 수직증축 제안)

  • Han, Ju-Yeon;Shin, Dong-Woo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.13 no.3
    • /
    • pp.152-159
    • /
    • 2012
  • Remodeling the existing building structure by recycling has great advantages compared with reconstruction in terms of environmentally contributions and reduced use of national resources. And no matter the existing floor area ratio, extension up to 30% of the exclusive using area and short project period have made remodeling a good alternative to reconstruction. However, the residents of aged housings that were being remodeled are either abandoning the remodeling project and turning to reconstruction. The main reason is remodeling project cannot increase the number of householders. In principal, it is prohibited to increase the number of floors during remodeling due to matters of safety. That is, all remodeling construction costs are borne by the residents, which leads to great financial pressure. Therefore, in order to improve these conditions, the residents' burden of remodeling charges should be reduced, and one of the ways to do so is to increase the number of householders. In this study, there will be suggestions of alternatives, including the story increase during remodeling, and compare the burden of remodeling charges on each of the residents, between proposed alternatives and the current remodeling plans by calculating the construction costs in order to prepare a foundation for a system that will promote remodeling.