• Title/Summary/Keyword: 허용소음레벨

Search Result 10, Processing Time 0.027 seconds

The Characteristics of HVAC Noise in Office Buildings (사무소 건물의 공조설비소음 특성)

  • Do, Young-Ju;Kim, Dong-Gyu;Kim, Heung-Sik
    • The Journal of the Acoustical Society of Korea
    • /
    • v.8 no.1
    • /
    • pp.59-66
    • /
    • 1989
  • This study aims to provide the basic data useful in assessing indoor-noise and designing sound devices in office buildings of HVAC system. The measurements of HVAC noise were carried out in office room and mechanical room. The performance of absorptive chamber and side branch was also estimated in the office buildings which have HVAC noise problems. The results of experiments show that the NR value of indoor HVAC noise is rather higher than that of ISO recommendations at the frequencies below 500Hz. In addition, the results indicated that the absorptive chamber attenuates noise over broad band frequencies and side branch reduces noise at the special resonant frequency.

  • PDF

Allowable sound pressure levels of ceiling mounted air-conditioning sounds (천장형 에어컨 소음의 허용 음압레벨 도출)

  • You, Jin;Jeong, Choong-Il;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.689-692
    • /
    • 2008
  • Noises from ceiling mounted air-conditioning units were recorded in various actual situations such as offices, classrooms and libraries. Eight specimens of air-conditioners from major domestic and foreign manufacturers' were investigated in this study. A head and torso simulator was located 1.5 m beneath the air-conditioner panel for the measurements and sound pressure levels of the recording sounds were varied from 28 to 55 dBA with 3 dB steps for subjective evaluations. A total of 88 stimuli was randomly presented to subjects using a headphone system in semi-anechoic chamber. Two-categorized (noisiness and amenity) nine-point scale was used as evaluation method. The third scale ('point 3') among the nine-point scale was set as the threshold of allowable level of the air-conditioning sounds in consideration of the real situations. The results indicate that the allowable sound pressure level is around 34 dBA for both noisiness and amenity categories.

  • PDF

A Study on the Workplace Noise Environment of Office Areas in Power Plant (발전소 관리실의 작업환경 소음에 관한 연구)

  • 김병삼
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.4
    • /
    • pp.35-41
    • /
    • 1998
  • The workplace noise environment is composed of three basic elements : manufacturing (in a generic sense) facilities, office areas, and the community around the facility. Work must be done by all employees , and this involves communication within a variety of locations within the facility ; areas may be extremely noisy, moderately noisy, or quiet, such as an office. At the same time, the facility should not be annoying to the community. In this paper, the workplace environmental noise of office areas in power plant are studied. Turbine generator in power plant generates the noise of 90∼95 dB(A) in the frequency range of 1 kHz, which may cause occupational hearing loss. By abatement method which are made of isolation material and distance damping effect, about 29.5 dB(A) reduction has been obtained in office areas of the Power Plant . But, the workplace environmental noise of office areas in the power plant is not suited to office's purpose.

Sound Calculation and Noise Control in a Building (건물의 실내소음레벨 영향 평가)

  • 김두훈
    • Journal of the KSME
    • /
    • v.35 no.10
    • /
    • pp.886-895
    • /
    • 1995
  • 근래들어 도시의 집중화와 고밀도화, 교통량의 증대 등 사회구조의 급격한 변화로 각종 소음원 들이 증가하고 있으며 소음에 대한 일반인의 관심도 점차 높아지고 있다. 건물의 경우 한정된 공간에서 거주자의 생활을 보다 쾌적하고 편리하게 하기 위해서 각종 설비들이 증가되고, 이들 설비들은 대용량화하는 추세에 있다. 건물내 공간의 기능을 능률적으로 유지하기 위해 설치된 각종 장비(공기조화기, 펌프, cooling tower, 보일러, 냉동기 \ulcorner 발전기 등)에서 발생하는 소음이 직접 실내로 투과되거나 이들이 발생하는 진동이 건물 구조체로 전달되어 실내소음을 야기시키는 경우가 많다. 따라서, 건물을 설계할 때는 실별 용도에 따라 허용소음도를 결정한후 이러한 실내 소음환경을 달성하기 위해 각종 조처를 강구하게 되는데, 이 글에서는 이러한 건물의 실내 소 음도 영향 평가의 하나로 특정 건물의 예를 들어 소음도 계산과 소음의 원인 및 대책에 관해 기술하고자 한다.

  • PDF

A Study on the Cabin's Noise Levels of Cargo-Passenger Ships plies South-West Coast line (서남 연근해 운항 정기화객선의 선내 소음에 관한 연구)

  • Yu, Young-Hun
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.05a
    • /
    • pp.207-212
    • /
    • 2006
  • The noise levels on board ship recognized at Europe in the early 1970s and the noise regulations on board ship began to put in a statutory form. After that, in 1982 "International Code on Noise Levels on Board Ships" adopted by IMO and it became standard to the newly built ship and remain so to this day. Especially, the ship engine room, which have huge main engine and various kinds of subsidiary machines, is under an extremely loud condition and so the worker who works in it is easy to lose his hearing. Recently, each nation regulates the allowable noise exposure time by law to protect the industrial employee from the occupational hardness of hearing. In our country, the allowable noise exposure time is regulated by the labor standard law but the international provisions regulated by IMO have been applied in case of the ship engine room. In this paper, the cabin's noise levels of cargo-passenger ships plies south-west coast line were investigated.

  • PDF

A Study on the Characteristics of Noise in Small Boats (소형 선박의 소음 특성에 관한 연구)

  • 최한규;신형일;양보석;이유원;김광홍
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.2
    • /
    • pp.134-142
    • /
    • 2003
  • Most of the vibration and noise generating in small boats come from shipboard machinery such as main engine, generator and auxiliary machinery etc. In order to build up the comfortable environment for the crew and to reduce the ambient noise, and provide basic materials for reasoning selection application, the design under allowable vibration & noise conditions and the examination of vibration condition of the new ships, this paper researches the frequency spectrum and order analysis of vibration and noise. The obtained results are summarized as follows : Through comparing the small boat internal noise with the regulation of IMO and DNV, it revealed that the noise level of main engine room accords with the standard, and the noise of other places are beyond the values. In this paper, two boats are analyzed, which are same type, same size and power, but the main engines noise of them is different. In order to search the noise source, the noise of main engine room and relative parts are measured. The third order of measured points is dominant in frequency domain by the order analysis.

A Study on the Allowable Deviation for the Measured Level of the Impact Sound Insulation Performance (바닥충격음 차음성능평가에 있어서 측정 레벨의 허용오차에 관한 연구)

  • 장길수;김선우
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.222-226
    • /
    • 1997
  • The reproducibility of measured level is a prior condition for the reliable assessment of the sound insulation performance. To review the reproducibility of impact sound level, 20 floors were selected in highrise apartment house, and then impact sound levels of two kinds of typical floors were measured with 10 times in each receiving point. The impact sound insulation class values were derived with a standard tapping machine and bang machine. Inspection of the result showed that smaller scale of the room caused to lower the reproducibility and that the higher values of standard deviation in lower frequency caused to deteriorate the reliability of assesment. Thus to enhance the reproducibility of the impact sound insulation class, greater allowable deviation of measured level is required in lower frequency than in higher one.

  • PDF

A Study on the Noise Levels of Cargo-Passenger Iron Ships ply South-West Coast Line (서남 연근해 운항 차도철부선의 선내 소음에 관한 연구)

  • Yu Young-Hun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.12 no.3 s.26
    • /
    • pp.193-199
    • /
    • 2006
  • The noise levels on board ship recognized at Europe in the early 1970s and the noise regulations on the ship began to put in a statutory form. After that, in 1982 'International Code on Noise Levels on Board Ships' adopted by IMO and it became a standards to the newly built ship and it remains up to recently. Especially, the ship engine room, which have huge main engine and various kinds of subsidiary machines, is under an extremely loud condition and so the worker who works in it is easy to lose his hearing. Recently, each nation regulates the allowable noise exposure time by law to protect the industrial employee from the occupational hardness of hearing. In our country, the allowable noise exposure time is regulated by the labor. standard law but the international provisions regulated by IMO have been applied in case of the ship engine room. In this paper, the cabin's noise levels of cargo-passenger ships plies south-west coast line were investigated.

  • PDF

A Study on the Correlation between Underwater Noise and Ground Vibration (지반진동과 수중소음의 상관성 연구)

  • Park, Jung-Bong;Kang, Choo-Won;Lee, Chang-Won
    • Explosives and Blasting
    • /
    • v.31 no.1
    • /
    • pp.11-22
    • /
    • 2013
  • This study compared and analysed ground vibration, size of underwater background noise in fish farms and underwater object noise of blasting and obtained ground vibration prediction equation through a regression analysis and correlation equation between underwater object noises in order to predict degrees of underwater noise in blasting and organize underwater noise control regulations. Before the study, when background noise of fish and shellfish farms with different conditions was measured, levels of background noise were different according to environmental characteristics of each farm. Ground vibration which causes underwater noise was measured to obtain a correlation equation between ground vibration and underwater object noise. Therefore, if underwater noise is predicted for each construction with a use of a correlation and permissible standards appropriate for each condition are applied for design and construction, financial loss from damages to fish and shellfish caused by development of insufficient technological and engineering logic can be prevented and successful construction with safety of underwater creatures guaranteed can be achieved.

An Investigation on Influence of Vibration Noise in Cooling Tower on Precision Equipments (산업용 냉각탑의 진동소음이 정밀장비에 미치는 영향에 대한 연구)

  • Lee, Jin-Kab
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.369-374
    • /
    • 2016
  • Cooling towers have been installed on rooftops or outside of buildings and widely applied to control the indoor temperature in residential areas and buildings. However, the noise and vibration resulting from their operation may cause problems in adjacent buildings. The purpose of this study is to measure the noise and vibration of an industrial cooling tower located adjacent to industrial plants and to investigate its influence on the surroundings according to an authorized evaluation standard. Further, in order to measure the effect of the vibration of the tower on the precision equipment inside the plant, an experiment is conducted to measure the vibration of the ground in the plant and the targeted precision equipment. The measurement results indicate that the noise in the cooling tower is 4 to 9 dB(A) higher than the maximum level defined in the standard of 68dB(A). The effect of the vibration of the tower on the precision equipment is comparatively minimal, because that in the supporting frame of the building is weaker than that on the floor where the precision equipment is located. The vibration of the floor on.