• Title/Summary/Keyword: 허용값

Search Result 790, Processing Time 0.035 seconds

Sensitivity Analysis of Ordinary Kriging Interpolation According to Different Variogram Models (베리오그램 모델 변화에 따른 정규 크리깅 보간법의 민감도분석)

  • Woo, Kwang-Sung;Park, Jin-Hwan;Lee, Hui-Jeong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.3
    • /
    • pp.295-304
    • /
    • 2008
  • This paper comprises two specific objectives. The first is to examine the applicability of Ordinary Kriging interpolation(OK) to finite element method that is based on variogram modeling in conjunction with different allowable limits of separation distance. The second is to investigate the accuracy according to theoretical variograms such as polynomial, Gauss, and spherical models. For this purpose, the weighted least square method is applied to obtain the estimated new stress field from the stress data at the Gauss points. The weight factor is determined by experimental and theoretical variograms for interpolation of stress data apart from the conventional interpolation methods that use an equal weight factor. The validity of the proposed approach has been tested by analyzing two numerical examples. It is noted that the numerical results by Gauss model using 25% allowable limit of separation distance show an excellent agreement with theoretical solutions in literature.

Calculation of Internal Exposure Dose in Korean Man Resulting from Single and Chronic Intake of Tritium (트리튬($^{3}H$)의 단일(單一) 및 만성섭취(晩性攝取)에 대한 한국인(韓國人)의 내부피복(內部被曝) 선량(線量) 계산(計算))

  • Kim, Jang-Lyul;Yook, Chong-Chul;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.8 no.2
    • /
    • pp.8-14
    • /
    • 1983
  • The doses to Korean adult by a single and chronic intake of tritiated water are determined using a three compartment model, which describes the retention of tritium radionuclide in body water and in bound organic form in the body. The results show that the total dose of a single intake, using retention half-time for the three-compartment of 9, 30, and 450 days, is 17.64 mrads ($176.4{\mu}Gy$) per 1mCi/kg ($3.7{\times}10^7Bq/kg$) intake, 97% of which is due to tritium in body water and 3% to bound tritium in tissue. In the chronic intake of 1mCi/day($3.7{\times}10^7Bq/day$) tritiated water, the total dose is 85.5 mrad/day(0.855mGy/day). Furthermore, in this study (MPC) a and (MPC)w values of tritium for Korean man are calculated by using the modified formula originated from ICRP Publication-2. From the results, we found that the (MPC) a, w values of ICRP underestimated approximately 50%, the (MPC)a, w values of Korean man must be elevated as high as approximately 50% than that of ICRP.

  • PDF

Fault-Tolerant Control of a DC-link Voltage Sensor for Grid-Connected Inverter Systems (계통연계형 인버터에서 직류단 전압 센서의 고장 허용 제어)

  • Kim, Gwang-Seob;Lee, Kyo-Beum;Lee, Dong-Choon;Kim, Jang-Mok
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.297-298
    • /
    • 2011
  • 최근 계통연계형 인버터 시스템에서 고 신뢰 운전이 매우 중요한 과제로 대두되고 있다. 특히 인버터의 고장에 관한 많은 연구가 진행되고 있다. 본 논문에서는 계통연계형 인버터에서 직류단 전압 센서의 고장 허용 제어 알고리즘을 제안한다. 직류단 전압의 추정값으로 고장의 발생 시에 허용 제어를 수행한다. 매우 빠른 동특성을 가진 제어기가 요구되는 제안된 알고리즘의 적용을 위해 데드비트 전류제어기를 사용한다. 시뮬레이션을 통해 제안된 알고리즘을 검증한다.

  • PDF

A Case Study on Duct Separation for Ensuring Supply Power of Underground Distribution Line (지중배전선로의 공급전력 확보를 위한 이격거리 검토 사례)

  • Jung, Yeon-Ha;Lee, Jae-Bong
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.422-423
    • /
    • 2008
  • 배전설계기준에 따르면 관로를 포설할 때 9공 초과시 도로 양측으로 시공하거나 전력구를 시공하게 되어 있으나 현장의 각종 지하 매설물 및 공사 예산 등 여러 가지 문제들로 인해 다회로 공법에 대한 검토가 필요한 실정이다. 본 논문에서는 A지점의 사례를 통해 케이블 허용전류 계산 프로그램(CYMCAP)을 이용하여 관로 이격거리에 따른 허용전류 값을 비교 검토하였다. 향후 전력수요 증가에 따른 대용량 배전선로의 안정적인 전력 확보를 위해서 다회로 공법 개발과 동시에 국내 지역적 환경 특성과 케이블 특성 등을 고려한 파라메타를 정립하여 정확한 허용용량을 산정하는 것이 중요하다.

  • PDF

EDISON_CFD를 이용한 에어댐 장착에 따른 공력 특성 분석

  • Lee, Jong-Yun;Yang, Seung-Won;Jeong, Hui-Jo
    • Proceeding of EDISON Challenge
    • /
    • 2015.03a
    • /
    • pp.632-635
    • /
    • 2015
  • 고혹에서의 자동차의 주행성능을 높이는 장치 중 하나인 에어댐이라는 장치가 있다. 본 연구에서는 장치의 실제적인 효과를 유동가시화를 통하여 확인하고자 연구를 진행하였다. 따라서 자동차 에어댐의 장착에 따른 공력 특성을 분석해보았다. 에어댐의 유무에 따른 자동차의 공력 특성을 확인하고, 에어댐의 길이에 따라 공력 특성이 어떻게 차이가 나는지 총 세 가지로 분류하여 비교하였다. 에어댐의 법적허용 높이와 전면 범퍼 높이의 중간 값, 법적허용높이, 법적허용높이의 1/2배에 해당하는 길이의 에어댐을 장착하여 어떠한 효과가 발생하는지 확인하였다.

  • PDF

A Probabilistic Structural Design Method of Composite Propulsion System (복합재 추진기관의 확률적 구조 설계 기법)

  • Hwang, Tae-Kyung;Kim, Hyung-Kun;Kim, Seong-Eun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.5
    • /
    • pp.80-85
    • /
    • 2013
  • This paper describes a probabilistic structural design method of composite propulsion system by comparing safety factor based on average value and allowable value with structural reliability. Generally, the required structural safety factor and reliability of composite pressure vessel are 1.5 and 0.999, respectively. In the case of structural design using average strength, the safety factor which satisfies the required structural reliability depends on the variation of fiber strength. However, the structural design using allowable value shows constant safety factor for the variation of fiber strength, because the allowable value of fiber strength is calculated by considering the variation of fiber strength. Through the analysis results, it was known that the fiber strength is the most important design random variable for the structural design of composite pressure vessel and the variation of fiber strength must be minimized to develop the high performance composite propulsion system.

A Study on the the Follow-up Analysis and the Characteristics of Exhaust Gas by Standard Mode of Chassis Dynamometer of Gasoline (가솔린 차량의 차대동력계 표준모드 별 추종성 분석 및 배출가스 특성에 관한 연구)

  • Seo, Dong Choon;Park, Sung-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.29-34
    • /
    • 2019
  • In this study, a gasoline test vehicle was evaluated for drive quality in emissions and fuel economy tests. The measurement results were compared with the manufacturer's suggested values to evaluate whether the tolerance ranges (fuel efficiency -5%, greenhouse gas +5%) were exceeded. We carried out tests with test subjects based on the SAE J2951 evaluation method. The test vehicle was a 2L gasoline vehicle. The drive following performance was found to increase under deliberate driving conditions and decreased in smooth driving conditions. As a result of the analysis of the drive following performance, the closer the value is to 1, the more accurate the driving is. (-) indicates harsh conditions, and (+) indicates gentle conditions. The basic data on the driver following between testers was obtained by analysis of the tests. The fuel efficiency correlation with the drive following performance within the target speed range of the fuel consumption mode. In the future, these measurement results can serve as key data for securing an exhaust gas database and fuel efficiency system for each measurement mode.

Development of Verification Method for ADCP (ADCP 유량 측정기기의 검정 방안 개발)

  • Noel Kang;Chi Young Kim;Kyung Min Kang;Yo Han Cho;Chang-Hwan Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.305-305
    • /
    • 2023
  • 수문조사기기 검정은 강수량, 수위, 유량 등과 같은 수문자료를 관측하는 수문조사기기가 대상지역의 수문상황을 정확하게 관측하는지를 검사하는 일련의 과정으로 「수자원의 조사 계획 및 관리에 관한 법률」 제12조에 법적 기반을 두고 있다. 검정 대상은 강수량, 수위, 유속, 유사량, 토양수분량, 증발산량, 증발량 측정기기 총 7종이며, 환경부장관으로부터 한강홍수통제소가 검정업무를 위임받고, 한국건설기술연구원과 한국수자원조사기술원이 위탁받아 운영중에 있다. 최근에는 증발산량, 토양수분량 및 유량 측정기기기 등이 첨단화되어 기존 검정 방식에 대한보완 및 신설에 대한 요구가 증가하고 있다. 특히, 유량 측정시 기존에 사용하였던 회전식 유속계는 ADCP(Acoustic Doppler Current Profiler) 유량측정기기로 대체되어 활용률이 2013년 24%에서2021년 67%로 약 2.8배 급격히 증가하였다. 하지만 수문조사기기 검정 관련 고시 내 ADCP에 대한검사방법 및 허용오차 등의 규정이 부재하여 수문조사기기의 검정 공백이 발생하는 등의 문제가 존재하고 있다. 이에 본 연구에서는 ADCP 운영 및 기술 현황, 현행 법령, 국외 사례 등을 검토하여 ADCP 유량측정기기의 검사방법 및 허용오차에 대한 방안을 제시하고자 한다. ADCP 검사방법은 총 5단계로 외관검사, 자가진단 검사, 온도센서 검사, 수심측정 검사, 유량비교측정 검사에 따라 검정을 실시한다. 첫 번째 외관검사시에는 기기 외관과 센서 등 물리적 손상을 점검하고, 두 번째 자가진단 검사에서는 센서 변환 매트릭스 값, 수신부 센서 테스트, RAM/ROM 테스트, 통신 테스트 등에 관한 정상값 산출 여부를 확인한다. 세 번째 온도센서 검사에서는 검증용 온도센서를 이용한 값과 ADCP에 부착된 온도센서 값과 차이를 확인하고 ±2℃초과시 재검사 또는 적절한 조치를 취한 후 다음 단계의 검사를 진행한다. 네 번째 수심측정 검사에서는 수조 내 수심 측정을 확인하여 실제 수심과의 오차를 확인하고 ±1% 초과시 재검사 또는 적절한 조치 후 다음 검사를 실시한다. 유량비교 측정검사에서는 각 기기 간의 평균유량의 상대오차를 평가하는 것으로 ±5%미만에는 합격, ±5이상 ±10%미만에서는 재검사, ±10%이상에서는 공장수리를 권고하도록 하고, 1~5 단계의 검사를 통과한 기기를 대상으로 인증서를 발급하도록 한다. 유량비교 측정검사시에는 매년 ADCP를 사용하는 일반기업 및 공공기관 등이 모여 ADCP의 성능을 상호간 비교하는 'ADCP 기술협력 워크숍'을 확장하여 실시할 수 있다. 각 검사 단계의 허용오차는 USGS 또는 제조사 기준과 2022년 ADCP 기술협력 워크숍 성능검사 분석 결과를 토대로 하였다. 본 ADCP 검정 방안은 향후 ADCP 모델별로 단계별 시범 검토를 통해 세부사항에 대한 제시가 필요하며, 온도센서 검사, 수심측정 검사, 유량 비교측정검사에 대한 허용오차에 대한 타당성에대한 검증 및 검토가 이루어져야 할 것으로 사료된다.

  • PDF

An improved RDO algorithm for the HEVC intra encoder (HEVC 인트라 인코더를 위한 RDO 알고리듬의 개선)

  • Won, Eui-Yeon;Chae, Soo-Ik
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2013.06a
    • /
    • pp.123-126
    • /
    • 2013
  • High Efficiency Video Coding 비디오 표준은 다양한 분할방식 및 35가지 예측모드를 허용하기 때문에 최적의 분할 및 예측모드를 결정하기 위한 연산량이 많다. 이를 줄이기 위하여 본 논문에서는 CU분할의 결정에 있어 가설검정을 이용하여 early splitting 및 early pruning을 위한 임계값을 설정하고, early splitting의 경우 연산의 결과값이 임계값보다 클 경우, early pruning의 경우 연산의 결과값보다 임계값보다 작을 경우 CU의 분할을 조기에 결정하는 논문[1]의 방법을 차용하여 CU의 분할을 조기에 결정하며, 추가로 비트율 및 왜곡을 연산하는 예측모드의 개수를 줄임으로써 인코더의 성능을 향상시켰다. 또한 예측모드를 결정할 때 RDOQ를 수행하지 않음으로써 예측모드를 빠르게 결정하며, TU의 분할에 있어서도 CBF의 값 및 임계값을 이용한 early pruning 방법을 수행하여 인코더의 성능을 향상시켰다. 실험결과 5.9%의 luma BDRate의 증가가 있었으나, 63.7%의 인코딩 시간이 절감되었다.

  • PDF

Numerical Analysis of Optical Soliton Transmission in Fibers with Periodically Compensated Loss (손실이 주기적으로 보상되는 광섬유에서의 솔리톤 전송에 대한 수치적 분석)

  • 이명우;김란숙;서동선
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.7
    • /
    • pp.1191-1202
    • /
    • 1994
  • We numerically investigate a stable propagation regime of soliton pulse trains in fibers with periodically copensated loss by lumped optical amplifiers. When amplification solition pulses is 1.2~1.5 and the minimum soliton separation normalized by the soliton width becomes about 6. In cases of L=50[km], the allowable range of A is 1.5~1.7 under =6. The maximum allowable variation of the loss compensation in each lumped amplifier becomes +-2% of the fiber loss when L=50[km], A=1.6, and =6. Generally, the allowable rages of the soliton amplitude A and amplifier gain are inversely proportional to the amplification period L.

  • PDF