• Title/Summary/Keyword: 핸드 피스

Search Result 74, Processing Time 0.024 seconds

Comparative Study of the Ablation Rates of Er: YAG Laser Irradiation on Dentin and Enamel (Er:YAG 레이저를 이용한 법랑질과 상아질의 절삭율 연구)

  • Kim, Kun-A;Ahn, Yong-Woo;Ko, Myung-Yun;Park, June-Sang
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.1
    • /
    • pp.131-140
    • /
    • 2005
  • The purpose of this study was to examine the ablation rate of Er: YAG laser irradiation on dentin and enamel and to observe the microscopic structures of cavities formed after ablation of enamel and dentin in using a bur and cavities formed after ablation using laser. Er:YAG laser irradiated at 200 mJ, 250mJ, 300mJ at the frequency of 20Hz, 15Hz. The following results were obtained : 1. The ablation rate of dentin groups at power of 3 W-6 W was about $1.103{\sim}2.639mm^3/sec$ and there were no significant differences between power of 4.5 W$\sim$6 W. 2. The ablation rate of enamel groups at power of 3 W-6 W was about $0.413{\sim}0.969mm^3/sec$ and there were no significant differences between power of 4 W$\sim$6 W. 3. With SEM examination of the cavity surface treated with the conventional high speed bur revealed relatively flat appearance almost covered with a debris like smear layer. 4. With SEM examination of the lased surface of dentin groups revealed no smear layer and no debris and openings of dentinal tubules were clearly opened. But the lased surfaces of the groups over 3 W were irregular and particles were loosely attached on it. 5. With SEM examination of the lased surface of enamel groups revealed severely destructed surface at the 6 W group and melting drop materials at the 3 W group. But the lased surface of 4 W group revealed clearly ablated surface. Therefore when cutting teeth using Er:YAG laser, the lasing power which can make effective ablation rate and minimize the thermal effect could be 3W at dentin and 4W at enamel. But, further studies and additional data collection will be necessary for appropriate lasing condition of Er:YAG laser.

Pneumomediastinum and Subcutaneous Emphysema after Dental Treatment (치과 수술 후 발생한 종격동 기종과 피하기종)

  • Cha, Yong-Hoon;Kim, Bum-Joon;Kim, Chang-Wan;Narm, Kyoung-Shik;Lee, Doo-Yun;Haam, Seok-Jin
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.797-799
    • /
    • 2010
  • The pneumomediastinum after a dental treatment occurs rarely and shows almost good prognosis, however it is potentially life-threatening complication. Here we report a case of pneumomediastinum, occurred by air bubbles originated from dental high speed equipment, via head and neck fascial space with literatures review.

A study about development of hand-piece for orthopedic surgery drived by battery (배터리 구동방식 정형외과용 핸드피스 개발에 대한 연구)

  • Son, Chang-Woo;Jang, Sung-Hui;Jang, Young-Ju;Seo, Tae-Il
    • Design & Manufacturing
    • /
    • v.9 no.1
    • /
    • pp.31-35
    • /
    • 2015
  • Recently, life expectancy increased in the development of medicine, the need for health has increased. Market for medical equipment is growing rapidly to an increase in the interest in health and aging worldwide. It is a device intended for ultra sensitive cleavage process of bone during joint replacement surgery on a technical advanced surgery, finishing, and hole. Domestic demand of the hand piece is a necessary condition on an ongoing basis. However, hand piece was made on the basis of the experience of many years in the country Japan, Germany, and the United States has spread to more than 90% domestic market. Feel the need for the development of the hand piece in the country, many companies are trying to in-house production hand piece. In an attempt to solve the problems with the hand piece of the present, in this paper, it was supposed to be a study of rechargeable hand piece to replace the existing pneumatic.

  • PDF

A Study about Experimental Evaluation of an Ultrasonic Surgery Unit for Bone-cutting (골 절삭용 초음파 수술기의 실험적 평가에 관한 연구)

  • Sa, Min-Woo;Shim, Hae-Ri;Ko, Tae-Jo;Lee, Jong-Min;Kim, Jong Young
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • In the dentistry field, an ultrasonic surgery unit is widely used in bone cutting and scaling to reduce operation time and minimize hemorrhage. The purpose of this study was to evaluate bone cutting and the effect of a specimen's temperature on the two-type ultrasonic surgery unit using a handpiece moving system(HMS). A HMS, which can cut the bone, was developed to perform the experimental procedure with precision of motion control. Bone specimens were prepared from a combination of epoxy-hardener and cortical bone of bovine leg. Through the bone-cutting experiment, the cutting depth was evaluated by not only scanning electron microscopy, but also Vernier calipers. Also, the temperature distribution was measured by a thermo-graphic camera. This study may be applied methodically in various experimental evaluations on a performance test by a HMS.

DC link voltage control method in the sinusoidal current drive system for dental hand-piece PMSM (치과 핸드피스용 고속 PMSM의 정현파 구동을 위한 인버터 직류 링크전압 제어기법)

  • Jeon, Geum-Sang;Park, Jae-Seung;Park, Sang-Uk;Kim, Sang-Hee;Ahn, Hee-Wook
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.4
    • /
    • pp.16-21
    • /
    • 2013
  • This paper presents a DC link voltage control method to reduce the ripple current and the switching loss in the sinusoidal current drive system for the wide-speed range PMSM. The DC link voltage of the three phase inverter in the sinusoidal current drive system is designed by the back-EMF voltage at maximum speed of the PMSM. In general, the drive systems have used the constant DC link voltage without reference to the motor speed. The current ripple causes hysteresis loss and makes noise. In addition, the switching loss on the inverter increases in proportion to the rise in the DC link voltage. In this paper, we propose the variable DC link voltage control method to reduce the current ripple in the PMSM drive system. We show reduction effect of the current repple and the switching loss through simulation results.

A study of user authentication protocol considering the mobility based on IPv6 in wireless LAN environment (무선랜 환경에서 IPv6기반의 이동성을 고려한 사용자 인증 프로토콜에 관한 연구)

  • Kim, Yi-Kang;Kim, Tea-Sub;Oh, Ryong;Lee, Sang-Jun;Cho, Choong-Ho
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2008.06d
    • /
    • pp.218-223
    • /
    • 2008
  • 최근 홈, 오피스 및 핫스팟 영역에서 초고속 멀티미디어의 서비스 수요가 많아짐에 따라 고속의 안정 적인 무선랜에 대한 수요도 증가하고 있다. Access Point 를 이용한 네트워크를 하는 무선랜은 네트워크 에 접근하는 사용자에 대한 인증 프로토콜을 통한 보안이 필요로 하며, 무선랜의 특성상 단말의 이동으로 인해, 핸드오프 시마다 반복되는 사용자 인증은 또 다른 문제를 야기한다. 또, 차세대 인터넷 프로토콜 IPv6는 현재의 주소체계인 IPv4 가 인터넷에 접속된 컴퓨터 수의 기하급수적으로 증가로 인해 빠른 속 도로 고갈되는 상황에서의 대안이다. 따라서 본 논문에서는 이동성을 고려하여 무선랜 환경에서 안전하게 사용자를 인증하고 서비스를 제공하기 위한 패스워드 기반의 사용자 인증 프로토콜을 제안한다. 또한 본 논문에서 제안한 프로토콜을 차세대 주소체계인 IPv6 환경을 바탕으로 구현하였고, 제안한 프로토콜에 대한 다양한 공격으로부터의 안전성을 분석 하였다.

  • PDF

A Study on Temperature Changes during Bone Scaling and Cutting of Dental Ultrasonic Scaling/Surgery System (치과용 초음파 스케일러/수술기 통합 시스템의 스케일링 및 절삭 시 온도 변화에 관한 연구)

  • Sa, Min-Woo;Ko, Tae-Jo;Kim, Jong Young
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.2
    • /
    • pp.1-8
    • /
    • 2020
  • While dental clinics still use the ultrasonic scaling/surgery tool for teeth scaling and cleaning the tool's use is expanding steadily to include treatment of damaged teeth and bone tissue. In this study, a handpiece moving system (HMS) was developed to evaluate bone scaling and cutting in the field of dentistry. The HMS, through a scaling test of bone using a scaler tip, it was able to identify surface damage. Additionally, a thermos-graphic camera was used to observe the temperature distribution that occurred during the bone scaling and cutting process. Consequently, we found that increasing the working load increased the amount of surface damage. Changes in temperature distribution occurred slowly and were maintained within safety bounds for 10 minutes. Going forward, we will compare the HMS performance on scaling and cutting with other devices.

Simulation and evaluation of fiber optics for hand-piece using ray tracing method (광선추적법을 이용한 핸드피스용 광섬유 광학계 시뮬레이션 및 특성 평가)

  • Park, J.H.;Kim, H.;Yang, B.C.;Lee, B.H.;Yoo, Y.J.;Kim, D.W.;Lee, C.W.;Lee, C.W.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1962-1963
    • /
    • 2002
  • The hand-piece fiber optics is applied to medical appliances such as glaucoma theraphy to focus semiconductor laser on the affected parts efficiently. In this paper, we evaluate optical properties such as beam power and radius of a hand-piece probe by experiments and we also simulate the hand-piece optics by ray tracing method in order to study major parameters to optimize focalization ability. As results, we show experimental and simulation results of the hand-piece optics and also summarize several requirements that have to be considered in optimizing the hand-piece optics.

  • PDF

저온 플라즈마를 이용한 바이오 메디컬 분야에의 응용

  • Park, Gan-Yeong;Kim, Gon-Jun;Lee, Hyeon-U;Yun, Ji-In;Sim, Jae-Yun;Kim, Gyeong-Tae;Kim, Gyu-Cheon;Lee, Jae-Gu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.41-41
    • /
    • 2010
  • 상온에 준하는 저온의 플라즈마를 발생시키는 장치들이 개발되면서, 저온 플라즈마와 생체조직간의 상호작용에 대한 연구가 큰 관심을 끌고 있다. 플라즈마에서 발생되는 다량의 이온과 활성종, 그리고 UV 등이 박테리아나 세포들과 작용함으로 해서 암세포 사멸, 치아 미백, 박테리아 살균/멸균, 지혈등의 효과들이 나타나고 있으며, 이러한 효과들을 극대화할 수 있는 장치 개발과 플라즈마와 생체조직간의 상호작용 메카니즘을 규명하는 것이 중요한 이슈가 되고 있다. 나노 금입자를 암세포의 막단백질인 FAK의 항체와 결합시킨 중합체를 만들어서, 암세포 표면에 나노 금입자붙이고, 플라즈마를 조사했을 때, 나노 금입자가 부착되지 않았을 경우에 비해서, 5배이상 사멸률이 증가하였다.[1] 변색된 치아에 미백제의 주성분인 과산화수소를 도포하고, 10분간 플라즈마를 조사하게 되면, 과산화수소만 도포했을 때에 비해, 치아 표면의 색이 3배이상 밝아지는 것을 관찰할 수 있었다. 과산화수소를 플라즈마에 노출시켰을 때, 활성종인 OH의 생성이 2배이상 증가하였고, 플라즈마에 의한 OH 생성의 촉진이 치아 미백효과가 증대되는 주된 요인인 것으로 추측된다.[2] 플라즈마에서 발생되는 O, $O_3$와 같은 활성종들은 살균력이 뛰어나기 때문에, 저온 플라즈마를 의료기구의 소독/멸균에 응용할 가능성이 아주 크다. 대장균이나 구강 세균이 플라즈마 처리로 5분이내에 멸균되는 것을 확인하였고, 핸드피스와 같은 의료기구를 오염시켜서 멸균 테스트를 수행하고 있다.

  • PDF

DENTAL MANAGEMENT OF THE RUSSELL-SILVER SYNDROME: CASE REPORT (Russell-Silver Syndrome 환아의 치과적 관리: 증례 보고)

  • Kim, Jun-Hhewk;Sohn, Hyung-Kyu;Kim, Seung-Hye;Choi, Hyung-Jun;Lee, Jae-Ho
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.6 no.2
    • /
    • pp.99-104
    • /
    • 2010
  • Russell-Silver syndrome is a genetic disorder characterized by intrauterine and/or postnatal growth restriction and typical facies. The clinical feature is various due to heterogeneous genetic characters. Their common findings are short stature without catch-up growth, normal head size for age, a distinctive triangular face with prominent forehead and a pointed chin, low set ears and clinodactyly of the fifth fingers. Intraoral features of the syndrome are microdontia, delayed tooth eruption, hypodontia, and crowding. More than 400 case have been reported in the literature, and estimated incidence is from 1 in 3000 to 1 in 100,000. In this case we performed caries treatment under the general anesthesia for the patient with Russell-Silver syndrome. Dentist have to consider microstomia for the management of patients with Russell-Silver syndrome.

  • PDF