• Title/Summary/Keyword: 핸드 피스

Search Result 74, Processing Time 0.031 seconds

Drive System of Battery Type Surgical Handpiece (배터리형 외과수술용 핸드피스 구동 시스템)

  • Kong, Tae-Woong;Park, Sang-Hoon;Yu, Jae-Sung;Lee, Byoung-Kuk;Won, Chung-Yuen
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.369-373
    • /
    • 2007
  • Battery type surgical handpiece is suitable for delicate surgical operating. The conventional air-type handpiece has a mechanical noise, a strong oscillation and a danger of infection. And the conventional contact switching type handpiece has problems that is restricted by surroundings. By reason of this kind, we studied noncontact switching type surgical handpiece to change conventional air type surgical handpiece and contact switching type.

  • PDF

치과계를 위하여 추천하는 감염 방지 실무, 1993

  • O, Se-Gwang;Kim, Gak-Gyun
    • The Journal of the Korean dental association
    • /
    • v.32 no.6 s.301
    • /
    • pp.409-416
    • /
    • 1994
  • 이 자료는 이전에 공표 되었던 치과계에서의 감염방지 실무에 관한 CDC 권장사항을 개정한 것으로, 새로운 데이터, 재료, 기술, 및 장비 등이 반영되었다. 이러한 권장사항을 이행하면 치과 환경 내에서, 환자에서 치과의료종사자로, 치과의료종사자에서 환자로, 그리고 환자에서 환자로 질병이 전염될 수 있는 위험성을 감소시켜 줄 것이다. 이 문서에는 감염방지의 원칙에 근거하여 다음과 같은 특정 권장사항들이 서술되어 있다. 즉, 치과의료종사자들의 예방접종; 보호용 치장과 방책 기법; 수세와 손의 보호; 날카로운 기구와 바늘의 사용과 관리; 기구들의 멸균이나 소독; 치과진료대 및 주위 표면들의 세척 및 소독; 소독과 치과기공소; 치과진료대의 공기관과 수관에 연결된 핸드피스; 역류방지용 밸브; 기타 구내용 치과 장비 등의 사용과 관리; 한번 쓰고 버리는 기구; 생검 표본의 취급; 치과교육 현장에서 발치 치아를 사용하는 것; 폐기물의 폐기; 권장사항들의 이행.

  • PDF

A COMPUTIONAL STUDY ON PERFORMANCE OF THE DENTAL AIR MOTOR HAND-PIECE (치과 치료기기용 에어 모터 핸드피스의 성능에 관한 수치 해석적 연구)

  • Sung, Y.J.;Lim, S.;Song, D.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.277-282
    • /
    • 2010
  • Imported vane type air motor and-piece is used widely in the domestic dental services. The imported hand-pieces are more than 90 percent in the domestic market. The air-motor unit of the hand-piece had not been developed inside of the country yet. Therefore it needs some research works. Purpose of this study is to design the air motor of the hand-piece for better performance. The geometry of the air-motor is based on product of NSK Company. The airflow of the air motor unit is simulated by Computational Fluid Dynamics. The performance analysis of the air motor units is investigated. ANSYS 12.0 CFX is used to analysis of the flowfield. Torque changes depends on spin calculated by the immersed solid method.

  • PDF

A Development of the Control System of BLDC Motor for Micro Motor Handpiece (마이크로 모터 핸드피스를 위한 BLDC 전동기 제어시스템 개발)

  • Baik, Won-Sik;Song, Hyun-Jig;Kim, Min-Huei;Kim, Dong-Hee;Lee, Heon-Uk;Hwang, Don-Ha
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.231-234
    • /
    • 2008
  • The permanent magnet BLDC motors are increasingly being used in high performance applications due to the high torque density and simplicity in their control. In this paper, the control system of the BLDC motor is developed which can be used for the micro motor handpiece, and position sensorless control is realized using back EMF measurement scheme, The validity and practical applications of the developed slotless BLDC motor and drive system are verified through the experimental results.

  • PDF

A COMPUTATIONAL STUDY ON PERFORMANCE OF THE DENTAL AIR MOTOR HAND-PIECE USING MOVING MESH METHOD (무빙메시를 이용한 치과 치료기기용 에어모터 핸드피스의 선응에 관한 수치해석적 연구)

  • Sung, Y.J.;Ryu, K.J.;Song, D.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.572-578
    • /
    • 2011
  • The vane type air-motor hand-piece is used widely in the dental services. There are a lot of experimental studies about air-motor but eccentrically off not many numerical studies by using Computational Fluid Dynamics. An air-motor has rotor which rotates at the center of inner housing. The retractable vanes are installed on the rotor. As the rotor of the air-motor rotates, vanes move up and down straightly in the radial direction along the guide. Therefore we have to analyze the unsteady flow field by accurate time dependent marching technique. ANSYS 12.0 CFX is used to analyze unsteady vane-motor flow field Analysis of the changing control volume inside air-motor is implemented by user-defined functions and moving mesh options. Rotational speed of the rotor is approximately 23,000rpm.

  • PDF

A NUMERICAL STUDY OF VANE TYPE DENTAL AIR-MOTOR WITH 7MINI HOLE OF AIR-OUTLETS (치과 치료기기용 에어모터 핸드피스의 출구 다공망에 대한 수치 해석적 연구)

  • Kim, Jae-Wook;Kim, Sung-Rae;Ryu, Kyung-Jin;Song, Dong-Joo
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.529-534
    • /
    • 2011
  • The air-motor unit of the hand-piece had not been developed inside of the country yet. Therefore it needs some research works. The objective of this study is to investigate the effect of the many mini holes at the outle of the air-motort. The flow fields analysis has been conducted by the immersed solid method using ANSYS 12.0 CFX.

  • PDF

Tooth Profile Analysis for Face Gear with 1:2 Gear Ratio in Handpiece with 160° Contra Angle (160도 Contra angle을 갖는 소형 핸드피스용 1:2증속기어의 치형 해석)

  • Choi, Jihun;Ahn, Sukyeong;Park, Sangshin
    • Tribology and Lubricants
    • /
    • v.30 no.2
    • /
    • pp.86-91
    • /
    • 2014
  • This paper presents a design procedure for a face gear and pinion used in a handpiece with a $160^{\circ}\acute{y}$ contra angle and 1:2 gear ratio. Based on the geometric theory of gearing, the tooth profile of the face gear and pinion is developed. To analyze the contact pressure, the gear profile should be determined before calculating the stress between the two gears. The concept of calculating the face gear profile is that it can be generated by the coordinate transformation of the shaper profiles, which have involute curves, using a simulation method from the gear manufacturing process.

Development of Battery Type Powered Handpiece Drive System for Surgical Operation (Battery type 외과수술용 핸드피스 구동 드라이브 시스템)

  • Ha, Jung-Jun;Yoon, Yong-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.4
    • /
    • pp.388-394
    • /
    • 2008
  • The purpose of this paper is concerned with a battery type powered handpiece drive system for surgical operation. Battery type powered surgical handpiece is suitable for delicate surgical operating. The conventional air-type handpiece has a mechanical noise, a strong oscillation and a danger of infection. And the conventional contact switching type handpiece has problems that is restricted by surroundings. By reason of this kind, we studied noncontact switching type surgical handpiece to change conventional air type surgical handpiece and contact switching type. Also in this paper we develop the battery type power handpiece drive system for surgical operation using controller IC UC3625 of UNITRODE CO. Finally some experimental and simulation results are provided to demonstrate the validity of the proposed battery type power handpiece drive system.

Development of Air-powered Handpiece for Surgical Operation (외과 수술용 Air-Powered Handpiece 개발)

  • 윤길상;이영훈;허영무;서태일;최길운
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.3
    • /
    • pp.188-193
    • /
    • 2004
  • The purpose of this paper is concerned with a development of an air-powered handpiece for surgical operation. The handpiece is the tool of surgical instruments and it can be used to interchange multiple attachments for drilling, pinning, sawing, driving screws and reaming. Most of domestic medical instruments bring in overseas and the air-powered handpiece imported from foreign countries at 100% too. Therefore we develop new air powered handpiece. we research in 2D and 3D modeling, design of air line, analyze structure. The air-powered handpiece composes of body, power supply air-line, elements for mechanical power transmission, attachment, and surgical tools. The handpiece is developed by several processes that 3D design, machining, heat treatment and coating. The developed handpiece is experimented to confirm check the efficiency.

Minimal Intervention Dentistry - 이론과 실제

  • 손호현
    • Proceedings of the KACD Conference
    • /
    • 2003.05a
    • /
    • pp.290-290
    • /
    • 2003
  • 지난 20세기 동안, 치아 우식에 대한 치료는 G.V. Black이 제안한 '예방 확대' 개념에 따른 와동형성 원칙에 따라 외과적 치칠 삭제의 형태로 수행되어져 왔다. 즉, 치아 우식 병소에 발견되면 치과의사들은 망설임 없이 핸드 피스를 들고 우식 부위 치질을 삭제하며, 수복재료에 따라 적합한 형태로 건전한 치질을 삭제하여 수복 와동을 형성하였다. 그러나 치아 우식에 대한 많은 연구 결과, 원인균과 산 생산 및 탈회와 재석회화 등에 대한 정보가 알려졌고, 접착 수복이 비약적 발전을 하여 임상 적용이 일반화되면서, 지난 10여년 이래 치아 우식에 대한 치료 개념이 점차 최소 치질 삭제와 건전 치질 보존으로 전환되어 왔고 이러한 개념을 통칭하여 Minimal Intervention Dentistry라 하고 있다. 21세기에는 치아 우식에 대한 치료가 minimal intervention dentistry의 개념 하에 점차 폭넓게 임상에 적용될 것으로 예상되며, 다음과 같은 원칙들이 제시되고 있다.(중략)

  • PDF