• Title/Summary/Keyword: 핵의학 검사

Search Result 664, Processing Time 0.029 seconds

The study of Breast Specific Gamma Imaging Protocol using Self-development Phantom (자체 제작된 팬텀을 적용한 Breast Specific Gamma Imaging 검사 프로토콜에 대한 고찰)

  • Lee, Hae-Jung;Lee, Juyoung;Lim, Kuen-Kyo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.39-47
    • /
    • 2014
  • Purpose As breast cancer patients continue to increase every year, cases of BSGI are on the rise with a heavier reliance on it. However, BSGI protocol in hospitals was not studied enough despite it was covered by hospital's condition and recommendation of manufacturers. The objective of the study was an examination of methods to be applicable to BSGI protocols, putting the self-development phantom to use in quality assessment of the images. Materials and Methods Dilon 6800 (Dilon Technologies Inc, Newport News, USA) was used in the study and five different sizes of sphere were distinctively produced in the phantom. The study used $^{99m}TcO_4$. The cases were classified in to three categories that background radioactivity to region of interest as ratio of 2: 4: 8, They were acquired images for 5, 7, 10mins. The acquired image was set region of interest according to the size of sphere, and We analyzed quantitative and qualitative analysis. The acquired data statistically analyzed with SPSS ver.18.0. Results As the result of quantitative and qualitative analysis, count rate of each sphere in accordance with difference of injection dose showed that higher count rate as injection dose and sphere size increased (P<0.005). Count rate of each sphere in accordance with difference of acquisition time showed that higher count rate as acquisition time and sphere size increased (P<0.005). Contrast noise ratio of each sphere in accordance with difference of injection dose showed that higher contrast noise ratio as injection dose increased. Particularly, Contrast noise ratio of eight times ratio images was the highest among. Contrast noise ratio of each sphere in accordance with difference of acquisition time showed that higher contrast noise ratio as acquisition time increased. And, Contrast noise ratio of seven minute image was the highest among (P<0.005). Conclusion There was significant change of Contrast noise ratio through quantitative and qualitative analysis. Moreover, We found usefulness of phantom. If Institutions identified image through the phantom study and they made BSGI protocol, We expected to help the improvement of diagnostic value of the images.

  • PDF

Evaluation of MR Based Respiratory Motion Correction Technique in Liver PET/MRI Study (Liver PET/MRI 검사 시 MR 기반 호흡 움직임 보정 방법의 유용성 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.15-22
    • /
    • 2018
  • Purpose Respiratory motion during PET/MRI acquisition may result in image blurring and error in measurement for volume and quantification of lesion. The aim of this study was to evaluate changes of quantitative accuracy, tumor size and image quality by applying MR based respiratory motion correction technique (MBRMCT) using integrated PET/MR scanner. Materials and Methods Data of 30 patients (aged $62.5{\pm}10.2y$) underwent $^{18}F-FDG$ liver PET/MR (Biograph mMR 3.0T, Siemens) study were collected. PET listmode data for 7 minutes was simultaneously acquired with maximum average gate (MAG), minimum time gate (MTG) and non gate (NG) T1 weighted MR images. Gated PET reconstruction was performed using mu-maps generated from MAG and MTG by setting 35% of efficiency window. Maximum SUV ($SUV_{max}$), peak SUV ($SUV_{peak}$), tumor size and full width at half maximum (FWHM) in the z-axis direction of MAG, MTG and NG PET images were evaluated. Results Compared to NG, mean $SUV_{max}$ and $SUV_{peak}$ were increased in MAG 13.15%(p<0.0001), 8.66%(p<0.0001), MTG 13.27%(p<0.0001), 8.80%(p<0.0001) and mean tumor size and FWHM were decreased in MAG 14.47%(p<0.0001), 15.49%(p=0.0004), MTG 14.89%(p<0.0001), 15.79%(p=0.0003) respectively. Mean $SUV_{max}$ and $SUV_{peak}$ of MTG were increased by 0.07%(p=0.8802), 0.13%(p=0.7766). Mean tumor size and FWHM of MTG were decreased by 0.49%(p=0.2786), 0.36%(p=0.2488) compared to MAG. There was no statistically significant difference between MAG and MTG which increase total scan time for about 7 and 2 minutes. Conclusion SUV, accuracy of tumor size and spatial resolution were improved in both of MAG and MTG by applying MBRMCT without installing additional hardware in liver PET/MR study. More accurate information can be provided with the increase of 2 minutes scan time if applying MTG of MBRMCT to various abdominal PET/MR studies affected by respiratory motion.

Usefulness of the Salivagram for the Diagnosis of Brain Lesions in Patients with Aspiration Pneumonia (뇌병변 환자에서 흡인성 폐렴 진단을 위한 Salivagram의 유용성)

  • Oh, Shin Hyun;Choi, Yung Sook;Ro, Dong Wook;Nam-Koong, Hyuk;Kim, Jae Sam;Leee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.48-52
    • /
    • 2013
  • Purpose: Bed, living a long time is required in adult patients with brain lesions such as stroke, traumatic brain injury, and Parkinson's disease, causing pneumonia and respiratory diseases may be due to aspiration of food or saliva. In patients with recurrent pneumonia or pulmonary symptoms, there is a need to determine the possibility of pulmonary aspiration due to aspiration of saliva. Materials and Methods: Saliva due to aspiration pneumonia diagnosis in patients with brain lesions request for inspection to the Department of Nuclear Medicine, 10 patients (male 6, female 4) were included in this study. Patients were fasted before the test, $^{99m}Tc_{O4}$ 185 MBq (5 mCi) of less than 1 mL of solution was administered in the oral cavity. Administration and 20 minutes of dynamic imaging acquisition, and immediately after that the static images were acquired. Delayed scan after 2-4 hours if necessary. Results: Positivity rate of all 10 patients was 60%. In 4 patients showed positive reactions after the administration of oral cavity in a 20-minute dynamic imaging were able to confirm whether the aspiration. In the remaining 2 patients, four hours of additional delay tests were able to confirm whether the aspiration. Conclusion: Does not require changes in patient posture compared to the other checks that can be diagnosed with aspiration pneumonia. A simple test and takes less time. Therefore be useful in providing information for the diagnosis and treatment modality.

  • PDF

The Usefulness According to the Incubation Time of PTH as Prediction Index of Hypocalcemia (저칼슘혈증 예측지표로서 부갑상선 호르몬 검사반응시간에 따른 유용성)

  • Au, Doo-Hee;Kim, Ji-Young;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.138-142
    • /
    • 2010
  • Purpose: PTH (parathyroid hormone) level is a useful index for prediction of hypocalcemia after thyroidectomy. The fast results are required for an early diagnosis of hypocalcemia. In this study, we evaluated the PTH change according to incubation time, and investigated the usefulness of hypocalcemia diagnosis of PTH results in early incubation time. Materials and Methods: The subjects were 131 patients who had taken the PTH test from July to August in 2009. All experiments were used IRMA method. PTH value were evaluated with the correlation between precision (10 times repeat) and recovery rate and at 0.5, 3, 6 and $18{\pm}2$ (below overnight) hours following incubation time. Data analysis was investigated with relationship of the sensitivity, specificity, PPV (positive predictive value) and accuracy. Results: The correlation was time-dependent with levels reaching $R^2$=0.987 at 0.5 hours, $R^2$=0.993 at 3 hours and $R^2$=0.996 at 6 hours compare to overnight levels. The precision (%CV${\pm}$SD) were $15.92{\pm}15.54$ at 0.5 hours, $6.91{\pm}7.38$ at 3 hours, $4.30{\pm}4.69$ at 6 hours and $4.59{\pm}2.59$ at overnight. The recovery rate (%Mean${\pm}$SD) were $96.8{\pm}5.44$ at 0.5 hours, $102.6{\pm}4.35$ at 3 hours, $100.7{\pm}2.56$ at 6 hours and $102.2{\pm}5.98$ at overnight. When 15 pg/ml of overnight density was set up as criteria, we measured the sensitivity, specificity and PPV, accuracy at 0.5, 3, 6 hours. The sensitivity was shown to 97.5% at all times. The specificity was 96.0% at 0.5 hours, 100% at 3 hours and 92.3% at 6 hours for control, respectively. The PPV was 86.6% at 0.5 hours, 100% at 3 hours and 92.8% at 6 hours. The accuracy was shown to 84.7% at 0.5 hours, 97.5% at 3 hours and 90.6% at 6 hours. These data were accompanied by a corresponding PTH value of overnight incubation time, which significantly correlated with early time results. Conclusion: The values of PTH at 3 hours has favorable the rate of concordance of 94.1% and may be useful for prediction of hypocalcemia, and it responses to overnight incubation PTH values. Therefore, This method may be an attractive alternative to proper treatment to stop symptom revelation by giving a calcium agent to the patient.

  • PDF

A Study on the Extraction Rate of Brain Tissues from a $^{99m}Tc$-HMPAO Cerebral Blood flow SPECT Examination of a Patient ($^{99m}Tc$-HMPAO 뇌혈류 SPECT 검사 시 환자에 따른 뇌조직 추출률에 대한 고찰)

  • Kim, Hwa-San;Lee, Dong-Ho;Ahn, Byeong-Pil;Kim, Hyun-Ki;Jung, Jin-Yung;Lee, Hyung-Nam;Kim, Jung-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.17-26
    • /
    • 2012
  • Purpose: This study mainly focuses on the patients treated with chemically stable radiopharmaceutical product $^{99m}Tc$-HMPAO (d,l-hexamethylpropylene amine oxime) which yielded reduced image quality due to a decreased brain extraction rate. $^{99m}Tc$-HMPAO will be examined further to determine whether this product may be accounted as a factor for this cause. Material and Methods: From January 2010 until December 2010, out of 272 patients who were all subjected to $^{99m}Tc$-HMPAO brain blood flow SPECT scans resulting from Cerebral Infarction; 23 patients(ages $55.3{\pm}9$, 21 males, 3 females) with decreased tissue extraction rate were examined in detail. The radiopharmaceutical product $^{99m}Tc$-HMPAO was used on patients with normal brain tissue exchange rate as well as those with reduced rate in order to prove its' chemical stability. The patients' age, sex, blood pressure, existence of diabetes, drug use, current health status, known side effects from CT/MRI, examination of the patients' past SPECT before/after images were accounted to determine the factors and correlations affecting the rate of blood tissue extractions. Result: After multiple linear regression analysis, there were no unusual correlations between the 6 factors excluding sex, and before/after examination images. Male subjects showed reduced brain tissue extraction rate than the females ($p$ > 0.05) 91.3% male, 8.7% female. Wilcoxon Matched-Pairs Signed-Ranks Test was used on the before/after images which yielded a value of 0.06, which did not indicate a significant amount of difference on the 2 tests ($p$ > 0.05). As a result, the before/after images indicated similar brain tissue extraction rates, and there were variations depending on the individual patient. Conclusion: The effects of the chemically stable radiopharmaceutical product $^{99m}Tc$-HMPAO depended on the patient's personal characteristics and status, therefore was considered to be a factor in reducing brain tissue extraction rate. The related articles of $^{99m}Tc$-HMPAO cerebral blood flow SPECT speculates a cerebrovascular disease and factors resulting from portal veins, and it was not possible to pin point the exact cause of decreasing brain tissue extraction rate. However, the $^{99m}Tc$-HMPAO cerebral blood flow SPECT scan proved to be extremely useful in tracking and inspecting brain diseases, as well as offering accurate results from patients suffering from reduced brain tissue extraction rates.

  • PDF

Usefulness of the $UBC^{TM}$ (Urinary Bladder Cancer) Test Compared to Urinary Cytology for Transitional Cell Carcinoma of the Bladder in Patients with Hematuria (혈뇨 환자의 방광암 진단에서 $UBC^{TM}$ (Urinary Bladder Cancer) 검사의 유용성)

  • Gil, Myung-Cheol;Kang, Do-Young;Seong, Youl-Koon;Jung, Se-Il;Kwon, Hyon-Young;Jung, Gyung-Woo;Kim, Duk-Kyu;Roh, Mee-Sook;Hwang, Tae-Ho;Yoon, Jin-Han
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.3
    • /
    • pp.192-197
    • /
    • 2001
  • Purpose: Urinary cytology and cystoscopic exam are effective methods for diagnosis of transitional cell carcinoma(TCC). But the former shows drawbacks such as the need for a well-trained examiner, and wide imprecision related to the variability of microscopic exam; the latter is an invasive method. $UBC^{TM}$ test detects the epitope on specific cytokeratin fragments released from epithelium of bladder cancer by immunoradiometric assay. We compared $UBC^{TM}$ test with urinary cytology for diagnosis of TCC to evaluate the utility of $UBC^{TM}$ test. Materials and Methods: Eighty-four patients with hematuria were included in our study. $UBC^{TM}$ tests (IDL Biotech, Sweden) were assayed in mid-stream urine according to the ordinary assay protocol. Nineteen patients were confirmed as TCC by cystoscopic examination and underwent transurethral resection (Group A). Other patients had various benign urinary tract conditions (Group B). Samples were considered positive as the $UBC^{TM}$ concentration was greater than $12{\mu}g/L$. Results: $UBC^{TM}$ levels were significantly different between group A ($95.9{\pm}166.4\;{\mu}g/L$) and group B ($19.2{\pm}85.6{\mu}g/L$) (P<0.001). Sensitivity for diagnosis of TCC was 89.5% (17/19) in UBC test and 47.4% (9/19) in cytology (p<0.05). Specificity for diagnosis of TCC was 81.5% (53/65) in $UBC^{TM}$ test and 100% (65/65) in cytology. $UBC^{TM}$ test was significantly more sensitive in stage Ta, $T_1$ tumors (84.6 vs 38.5%, p<0.05) and in grade I (83.3% vs 16.7%, p<0.05) than cytology. $UBC^{TM}$ test showed a tendency to be more sensitive as the grade was higher (83.3% in Grade I, 90% in Grade II and 100% in Grade III). Conclusion: $UBC^{TM}$ test could be a useful method in distinguishing TCC from other benign genitourinary diseases. Moreover, $UBC^{TM}$ test could be an especially valuable marker for diagnosis of TCC in patients with early TCC of low grade TCC compared to urinary cytology. Therefore, mbined use of $UBC^{TM}$ test in association with cytology is helpful to overcome the limited sensitivity of cytology.

  • PDF

Building the Process for Reducing Whole Body Bone Scan Errors and its Effect (전신 뼈 스캔의 오류 감소를 위한 프로세스 구축과 적용 효과)

  • Kim, Dong Seok;Park, Jang Won;Choi, Jae Min;Shim, Dong Oh;Kim, Ho Seong;Lee, Yeong Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.76-82
    • /
    • 2017
  • Purpose Whole body bone scan is one of the most frequently performed in nuclear medicine. Basically, both the anterior and posterior views are acquired simultaneously. Occasionally, it is difficult to distinguish the lesion by only the anterior view and the posterior view. In this case, accurate location of the lesion through SPECT / CT or additional static scan images are important. Therefore, in this study, various improvement activities have been carried out in order to enhance the work capacity of technologists. In this study, we investigate the effect of technologist training and standardized work process processes on bone scan error reduction. Materials and Methods Several systems have been introduced in sequence for the application of new processes. The first is the implementation of education and testing with physicians, the second is the classification of patients who are expected to undergo further scanning, introducing a pre-filtration system that allows technologists to check in advance, and finally, The communication system called NMQA is applied. From January, 2014 to December, 2016, we examined the whole body bone scan patients who visited the Department of Nuclear Medicine, Asan Medical Center, Seoul, Korea Results We investigated errors based on the Bone Scan NMQA sent from January 2014 to December 2016. The number of tests in which NMQA was transmitted over the entire bone scan during the survey period was calculated as a percentage. The annual output is 141 cases in 2014, 88 cases in 2015, and 86 cases in 2016. The rate of NMQA has decreased to 0.88% in 2014, 0.53% in 2015 and 0.45% in 2016. Conclusion The incidence of NMQA has decreased since 2014 when the new process was applied. However, we believe that it will be necessary to accumulate data continuously in the future because of insufficient data until statistically confirming its usefulness. This study confirmed the necessity of standardized work and education to improve the quality of Bone Scan image, and it is thought that update is needed for continuous research and interest in the future.

  • PDF

Can the C-14 Urea Breath Test Reflect the Extent and Degree of Ongoing Helicobacter pylori Infection? (C-14 요소호기검사의 정량치가 Helicobacter pylori 감염 정도를 반영할 수 있을까?)

  • Lim, Seok-Tae;Sohn, Myung-Hee;Lee, Seung-Ok;Lee, Soo-Teik;Jeong, Myoung-Ja
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.1
    • /
    • pp.61-68
    • /
    • 2001
  • Purpose: The C-14 urea breath test (C-14 UBT) is the most specific noninvasive method to detect Helicobacter (H) pylori infection. We investigated if the C-14 UBT can reflect the presence and degree of H. pylori detected by gastroduodenoscopic biopsies (GBx). Materials and methods: One hundred fifty patients (M:F=83:67, age $48.6{\pm}11.2$ yrs) underwent C-14 UBT, rapid urease test (CLO test) and GBx on the same day. For the C-14 UBT, a single breath sample was collected at 10 minutes after ingestion of C-14 urea (137 KBq) capsule and counting was done in a liquid scintillation counter for 1 minute, and the results were classified as positive (${\geq}200dpm$), Intermediate ($50{\sim}199dpm$) or negative (<50 dpm). The results of CLO tests were classified as positive or negative according to color change. The results of GBx on giemsa stain were graded 0 (normal) to 4 (diffuse) according to the distribution of H. pylori by the Wyatt method. We compared C-14 UBT results with GBx grade as a gold standard. Results: In the assessment of the presence of H. pylori infection, the C-14 UBT global performance yielded sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of 92.5%, 88.4%, 97.1%, 88.4% and 91.3%, respectively. However, the CLO test had sensitivity, specificity, PPV, NPV and accuracy of 83.2%, 81.4%, 91.8%, 81.4% and 82.7%, respectively. The quantitative values of the C-14 UBT were $45{\pm}27$ dpm in grade 0, $707{\pm}584dpm$ in grade 1, $1558{\pm}584dpm$ in grade 2, $1851{\pm}604dpm$ in grade 3, and $2719{\pm}892dpm$ in grade 4. A significant correlation (r=0.848, p<0.01) was found between C-14 UBT and the grade of distribution of H. pylori infection on GBx with giemsa stain. Conclusion: We conclude that the C-14 UBT is a highly accurate, simple and noninvasive method for the diagnosis of ongoing H. pylori infection and reflects the degree of bacterial distribution.

  • PDF

Usability of Multiple Confocal SPECT SYSTEM in the Myocardial Perfusion SPECT Using $^{99m}Tc$ ($^{99m}Tc$을 이용한 심근 관류 SPECT에서 Multiple Confocal SPECT System의 유용성)

  • Shin, Chae-Ho;Pyo, Sung-Jai;Kim, Bong-Su;Cho, Yong-Gyi;Jo, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.65-71
    • /
    • 2011
  • Purpose: The recently adopted multiple confocal SPECT SYSTEM (hereinafter called IQ SPECT$^{TM}$) has a high difference from the conventional myocardial perfusion SPECT in the collimator form, image capture method, and image reconstruction method. This study was conducted to compare this novice equipment with the conventional one to design a protocol meeting the IQ SPECT, and also determine the characteristics and usefulness of IQ SPECT. Materials and Methods: 1. For the objects of LEHR (Low energy high resolution) collimator and Multiple confocal collimator, $^{99m}Tc$ 37MBq was put in the acrylic dish then each sensitivity ($cpm/{\mu}Ci$) was measured at the distance of 5 cm, 10 cm, 20 cm, 30 cm, and 40 cm respectively. 2. Based on the sensitivity measure results, IQ SPECT Protocol was designed according to the conventional general myocardial SPECT, then respectively 278 kBq/mL, 7.4 kBq/mL, and 48 kBq/mL of $^{99m}Tc$ were injected into the myocardial and soft tissues and liver site by using the anthropomorphic torso phantom then the myocardial perfusion SPECT was run. 3. For the comparison of FWHMs (Full Width at Half Maximum) resulted from the image reconstruction of LEHR collimator, the FWHMs (mm) were measured with only algorithms changed, in the case of the FBP (Filtered Back projection) method- a reconstruction method of conventional myocardial perfusion SPECT, and the 3D OSEM (Ordered subsets expectation maximization) method of IQ SPECT, by using $^{99m}Tc$ Line source. Results: 1. The values of IQ SPECT collimator sensitivity ($cpm/{\mu}Ci$) were 302, 382, 655, 816, 1178, and those of LEHR collimator were measured as 204, 204, 202, 201, 198, both at the distance of 5 cm, 10 cm, 20 cm, 30 cm, and 40 cm respectively. It was found the difference of sensitivity increases up to 4 times at the distance of 30 cm in the cases of IQ SPECT and LEHR. 2. The myocardial perfusion SPECT Protocol was designed according to the geometric characteristics of IQ SPECT based on the sensitivity results, then the phantom test for the aforesaid protocol was conducted. As a result, it was found the examination time can be reduced 1/4 compared to the past. 3. In the comparison of FWHMs according to the reconstructed algorithm in the FBP method and 3D OSEM method followed after the SEPCT test using a LEHR collimator, the result was obtained that FWHM rose around twice in the 3D OSEM method. Conclusion : The IQ SPECT uses the Multiple confocal collimator for the myocardial perfusion SPECT to enhance the sensitivity and also reduces examination time and contributes to improvement of visual screen quality through the myocardial-specific geometric image capture method and image reconstruction method. Due to such benefits, it is expected patients will receive more comfortable and more accurate examinations and it is considered a further study is required using additional clinical materials.

  • PDF

The study on Standard Uptake Value(SUV) change according to time input difference in PET/CT scan (PET/CT 검사에서 시간 입력 차이에 따른 표준화섭취계수(SUV) 변화에 대한 고찰)

  • Kim, Kyung-Sik;Lee, Ju-Young;Jung, Woo-Young;Kim, Jung-Sun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.21-25
    • /
    • 2011
  • Purpose: $^{18}F$-FDG Fusion Whole Body PET scan is performed approximately 1 hour after injecting $^{18}F$-FDG. At this point in the injection procedure, as a tool of the criteria of time input, time of clocks or computers can be used and in the scan procedure, time of workstation can be used. In case that synchronized time input is not done in the injection and scan procedures for PET scan, time error from injection to scan can occur. This time error may affect Standard Uptake Value (SUV) being used as quantitative assessment. Therefore, in this study, we analyzed the change of SUV according to time input difference and necessity of time synchronization. Materials and Methods: The analysis was performed to 30 patients ($54.8{\pm}15.5$ years old) who examined $^{18}F$-FDG Fusion Whole Body PET scan in Department of nuclear medicine, Asan Medical Center from December 2009 to February 2010. To observe the change of SUV according to time input difference, the image was reconstructed and analyzed by artificially changing time difference of 1, 2, 3, 5, 10, 20 min against the same patients based on 60 minutes. Result: SUV of the image that reconstructed the images of 30 patients by giving intervals of 1, 2, 3, 5, 10, 20 min respectively and the image that entered original time was compared and analyzed through paired t-test. Based on 0 minute, mean SUV of aorta was changed by 0.3, 1.1, 1.4, 3.2, 4.7, 12.5% respectively and there was no statistically significant difference in 1, 2 minutes (p>0.05) but there was significant difference in 3, 5, 10, 20 min (p<0.05). The changes of $SUV_{avg}$ of liver were 1.6, 2.5, 3.0, 4.2, 6.6, 12.8% in 1, 2, 3, 5, 10, 20 min respectively and the changes of $SUV_{max}$ of primary lesion were 1.0, 1.5, 2.2, 3.5, 6.6, 12.8% respectively (p<0.05). Conclusion: Errors may occur in the process of measuring or recording variables affecting SUV such as height and weight of patients, $^{18}F$-FDG dose, Emission scan start time etc. and as these errors are more, the accurate assessment of SUV is interfered. Therefore, in order to assess SUV more accurately, it is thought that efforts to minimize these errors should be made. Of these efforts, time synchronization will be a cornerstone for accurate scanning.

  • PDF