• Title/Summary/Keyword: 해수수질

Search Result 405, Processing Time 0.029 seconds

Development of Strategies to Improve Water Quality of the Yeongsan River in Connection with Adaptation to Climate Change (기후변화의 적응과 연계한 영산강 수질개선대책 개발)

  • Yong Woon Lee;Won Mo Yang;Gwang Duck Song;Yong Uk Ryu;Hak Young Lee
    • Korean Journal of Ecology and Environment
    • /
    • v.56 no.3
    • /
    • pp.187-195
    • /
    • 2023
  • Almost all of the water from agricultural dams located to the upper of the Yeongsan river is supplied as irrigation water for farmland and thus is not discharged to the main stream of the river. Also, most of the irrigation water does not return to the river after use, adding to the lack of flow in the main stream. As a result, the water quality and aquatic health of the river have become the poorest among the four major rivers in Korea. Therefore, in this study, several strategies for water quality improvement of the river were developed considering pollution reduction and flow rate increase, and their effect analysis was performed using a water quality model. The results of this study showed that the target water quality of the Yeongsan river could be achieved if flow increase strategies (FISs) are intensively pursued in parallel with pollution reduction. The reason is because the water quality of the river has been steadily improved through pollution reduction but this method is now nearing the limit. In addition, rainfall-related FISs such as dam construction and water distribution adjustment may be less effective or lost if a megadrought continues due to climate change and then rainfall does not occur for a long time. Therefore, in the future, if the application conditions for the FISs are similar, the seawater desalination facility, which is independent of rainfall, should be considered as the priority installation target among the FISs. The reason is that seawater desalination facilities can replace the water supply function of dams, which are difficult to newly build in Korea, and can be useful as a climate change adaptation facility by preventing water-related disasters in the event of a long-term megadrought.

Estimation of Water Quality Index for Coastal Areas in Korea Using GOCI Satellite Data Based on Machine Learning Approaches (GOCI 위성영상과 기계학습을 이용한 한반도 연안 수질평가지수 추정)

  • Jang, Eunna;Im, Jungho;Ha, Sunghyun;Lee, Sanggyun;Park, Young-Gyu
    • Korean Journal of Remote Sensing
    • /
    • v.32 no.3
    • /
    • pp.221-234
    • /
    • 2016
  • In Korea, most industrial parks and major cities are located in coastal areas, which results in serious environmental problems in both coastal land and ocean. In order to effectively manage such problems especially in coastal ocean, water quality should be monitored. As there are many factors that influence water quality, the Korean Government proposed an integrated Water Quality Index (WQI) based on in situmeasurements of ocean parameters(bottom dissolved oxygen, chlorophyll-a concentration, secchi disk depth, dissolved inorganic nitrogen, and dissolved inorganic phosphorus) by ocean division identified based on their ecological characteristics. Field-measured WQI, however, does not provide spatial continuity over vast areas. Satellite remote sensing can be an alternative for identifying WQI for surface water. In this study, two schemes were examined to estimate coastal WQI around Korea peninsula using in situ measurements data and Geostationary Ocean Color Imager (GOCI) satellite imagery from 2011 to 2013 based on machine learning approaches. Scheme 1 calculates WQI using estimated water quality-related factors using GOCI reflectance data, and scheme 2 estimates WQI using GOCI band reflectance data and basic products(chlorophyll-a, suspended sediment, colored dissolved organic matter). Three machine learning approaches including Random Forest (RF), Support Vector Regression (SVR), and a modified regression tree(Cubist) were used. Results show that estimation of secchi disk depth produced the highest accuracy among the ocean parameters, and RF performed best regardless of water quality-related factors. However, the accuracy of WQI from scheme 1 was lower than that from scheme 2 due to the estimation errors inherent from water quality-related factors and the uncertainty of bottom dissolved oxygen. In overall, scheme 2 appears more appropriate for estimating WQI for surface water in coastal areas and chlorophyll-a concentration was identified the most contributing factor to the estimation of WQI.

SiHwa Lake Tidal Power Plants (시화호 조력발전소)

  • Chung, Jin-Dal;Paik, Doo-Hyun;Lee, Shang-Oh
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.493-497
    • /
    • 2005
  • 엄청난 자원의 매장고, 국가간의 대규모 교역을 가능케 한 항로, 어족자원의 공급원등으로서 인류의 생존과 번영에 일익을 담당하고 있는 바다는 인간의 증가하는 에너지 수요를 지속적으로 감당할 수 있는 무공해에너지의 보고로도 다가오고 있다. 그러나, 에너지 밀도가 타 에너지에 비하여 상대적으로 낮아 큰 규모의 에너지추출장치가 필요하다는 단점에도 불구하고, 대부분의 바다에서 하루에 두 번 씩 발생하는 조석현상을 이용하는 조력발전은 조석의 반복적이고 주기적인 특성 , 태양계가 존속하는 한 영구히 발생한다는 영속성, 현대과학과 관련기술의 진보 등으로 전 세계적으로 그 개발에 인류의 관심이 높아져 있다. 현재 조력발전소가 건설 중인 시화호는 포화상태에 있는 수도권에 공업용지를 공급하고 우량농지 조성으로 경쟁력 있는 농업을 육성하기 위하여 담수호로 조성되었으나,하수처리장 등 기초환경시설이 미비한 상태에서 인근지역으로부터 오염물질이 유입되어 수질이 악화되자 정부는 수질개선을 위하여 시화호를 해수호로 용도를 변경하였다. 본 논문에서는 조수간만의 차를 이용하여 무공해 전력을 생산하는 조력발전의 원리 및 최적발전량 산정기법과 높은 조수간만의 차로 조력개발적지로 유망한 서해안에 건설하게 될 시화호 조력발전소의 사업 및 기후변화협약 이행 시 기대효과 등에 대하여 논하고자 한다.

  • PDF

The Prediction of Water Temperature at Saemangeum Lake by Neural Network (신경망모형을 이용한 새만금호 수온 예측)

  • Oh, Nam Sun;Jeong, Shin Taek
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.27 no.1
    • /
    • pp.56-62
    • /
    • 2015
  • The potential impact of water temperature on sea level and air temperature rise in response to recent global warming has been noticed. To predict the effect of temperature change on river water quality and aquatic environment, it is necessary to understand and predict the change of water temperature. Air-water temperature relationship was analyzed using air temperature data at Buan and water temperature data of Shinsi, Garyeok, Mangyeong and Dongjin. Maximum and minimum water temperature was predicted by neural network and the results show a very high correlation between measured and predicted water temperature.

The Effect on the Marine Water and Sediment Quality by the Use of Nano-S 1. Result of Water Tank Experiment (Nano-S가 해양수질 및 저질에 미치는 영향에 관한 연구 1. 실내수조실험 결과)

  • Cho, Hyeon-Seo;Cho, Chon-Rae;Jang, Young-Nam
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.8 no.3
    • /
    • pp.158-163
    • /
    • 2005
  • The purpose of this study was to observe the effect on the marine environment by the use of Nano-S. Nano-S was made to apply to improve the red tide bloom. The experiment was performed at round tank with volume of 180 L. Each tank was filled with an aggravated sediment about $14{\pm}1cm$ hight and sea water. The water flow-rate of tank was established on the rate of 6.25 L/hr. Sea water level was fitted to 40 cm, therefore the filled water was about 150 L. The sediment was stabilized during one week. Then the Nano-S and the red mud were added into each tank 0 kg(control), 1 kg(tank A), 2 kg(tank B), 5 kg(tank C) and 10 kg(tank D) each other. The quantity was fulfilled with 0 kg(control), 2.75 kg(tank A), 5.51 kg(tank B), 13.77 kg(tank C) and 27.55 kg(tank D) per square meter of sediment. The experiment was performed during 30 days. Water and sediment samples were collected from each tanks on the before 1hour and after 1, 3, 6, 12 hour and 1st, 3th, 5th, 7th, 10th, 15th, 30th day of the experiment period. The change of water and sediment quality was analyzed before and after applying the Nano-S and the red mud.

  • PDF

Evaluation of Seawater Reverse Osmosis Desalination System with UF and Disk Filter as Pre-Treatment (UF와 디스크필터를 전처리시설로 이용한 역삼투압해수담수설비의 평가)

  • Yang, Keun-Mo;Lim, Dong-Hoon;Kim, Joon Ha;Jung, Hyung-Ho
    • Transactions of the KSME C: Technology and Education
    • /
    • v.1 no.1
    • /
    • pp.59-68
    • /
    • 2013
  • In the present study, sea water reverse osmosis desalination system was composed with an ultra-filtration membrane as a pre-treatment. Sea water was induced into the pre-treatment composed with an auto-screen filter and an ultra-filtration membrane. It was proved that the permeate of the pre-treatment was adequate for reverse osmosis desalination system by measuring the $SDI_{15}$ and the turbidity. Feed salinities was changed by mixing the brine and the permeate. Inlet salinities effected the performances of sea water reverse osmosis desalination system in a large amount such as the salt rejection, the recovery ratio, the pressure, the product salinity. Energy consumptions per the ton of the product were almost linearly increased with the inlet salinities.

Experimental Study on Effect of Hybrid Quay Wall According to Floating Breakwater (부유식 방파제에 따른 안벽 내 영향에 관한 실험적 연구)

  • Son, Hyok Jun;Cho, Yong-Sik
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.53-53
    • /
    • 2011
  • 최근에 세계화, 무역자유화에 따른 컨테이너 물동량이 증가하고 있다. 그에 발맞추어 초대형 컨테이너선이 등장하게 되고 신개념, 고효율의 항만인프라의 도입이 요구되고 있다. 이런 배경에 따라 최근에 국내외에서 부유식 안벽에 관한 기술 개발 및 연구가 더욱 필요한 상황이다. 부유식 안벽은 이동가능한 부유식 구조로 기존 항만의 확장 또는 신규 항만 건설시 환경문제를 최소화하고 기항, 선박수 및 선박의 크기에 따른 안벽 배열을 최적화 할 수 있어 항만 기능을 고도화함으로써 녹색항만을 구현하는데 많은 기여를 하게 될 것이다. 특히 컨테이너선의 양현하역과 환적이 가능하게 되어 컨테이너 터미널의 화물처리능력을 확대할 수 있을 뿐 아니라 기항선박의 체류시간을 최소화 할 수 있는 장점이 있다. 또한, 우리나라는 삼면이 바다로 크고 작은 항만들이 해안선을 따라 위치하고 있다. 이러한 항만들을 안전하게 보호하기 위한 방파제는 항만 기본시설인 외곽시설 중의 가장 중요한 구조물이다. 국내에 설치된 방파제는 대부분 사석이나 케이슨을 이용한 중력식 방파제로써 해저에 고정되어 해수면상으로 건설되므로 항내 외 해수교환을 차단하여 항내 수질악화를 초래할 뿐만 아니라 수심에 따라 막대한 건설비용이 소요된다. 따라서 친환경적이고 경제적인 새로운 형식의 방파제에 대한 연구 및 개발이 필요한 실정이다. 그 중 하나의 대안인 부유식 방파제는 공사기간이 짧고 비교적 수심에 대한 제약이 없는 것이 특징이다. 또한 해수의 원활한 흐름이 가능하기 때문에 중력식 방파제에 비해 경제적이며, 환경적 측면에서 큰 장점이 있다. 하지만 아직까지 부유식 방파제에 대한 국내 및 해외에서의 연구는 이론적인 해석을 중심으로 이루어져 부유식 방파제 실용화를 위한 많은 연구가 수행되어야 할 것으로 판단된다. 본 연구에서는 부유식 안벽 내에서 정온도를 효과적으로 유지하기 위하여 부유식 방파제를 설치하고 소파성능과 부유식 안벽내의 영향성을 수리모형실험을 통해 분석하였다.

  • PDF

Optimization of Coagulation and Media Filtration Process for Low Turbidity Seawater (저탁도 해수원수 특성에 적합한 응집 - 여과 공정의 최적화)

  • Son, Dong-Min;Jo, Myeong-Heum;Kim, Jeong-Sook;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.4
    • /
    • pp.251-257
    • /
    • 2014
  • This research is focused on coagulation and sand filtration process as a pretreatment of RO seawater desalination. RO systems require sufficient and reliable pretreatment process to produce superior quality of RO feedwater that can mitigate RO membrane fouling. This experiment was conducted to investigate the effectiveness of coagulation and filtration process under various experimental conditions including different coagulant dose, flocculation mixing intensity and time, turbidity, and filtration rate. The experimental results showed that the optimum pretreatment conditions resulting in lower SDI value suitable for RO feedwater were coagulation pH 6.5, raw water turbidity greater than 4 NTU, and media bed depth greater than 550 mm. However, flocculation mixing intensity, coagulant dose, and filtration rate relatively affected little on the filtration efficiency.

Theoretical Analysis and Effect of Condenser In-leakage in the Secondary Systems of YGN-1, 2 (영광-1, 2호기 2차계통 복수기누설의 이론적 분석 및 영향평가)

  • Suk, Tae-Won;Lee, Yong-Woo;Kim, Hong-Tae;Park, Sang-Hoon
    • Nuclear Engineering and Technology
    • /
    • v.23 no.3
    • /
    • pp.299-305
    • /
    • 1991
  • Corrosive environment may be generated within steam generators from condenser cooling water in-leakage. Theoretical analysis of the accumulation of chloride as a sea water impurity is being carried out for the condenser cooling water used at YGN-1,2 nuclear power stations. Calculations have shown that highly concentrated chloride solution would be produced within the steam generators in the case of sea water in-leakage. Maximum allowable design condenser leak rate(0.5 gpm) leads chloride concentration of 2.3 ppm at steam generetor and 0.6 ppm at hotwell with the maximum blowdown rate and condensate purification. Concentration factor at steam generator is dependent only on both blowdoum rate and condensate purification efficiency as follows, Concentration Factor(equation omitted)(B$\neq$O) Blowdown and condensate purification are evaluated as the only effective measures to remove impurities from the secondary systems.

  • PDF

SANITARY SURVEY OF SHELLFISH GROWING AREA ON WEST FOWL RIVER ESTUARY, MOBILE, ALABAMA (미국 Alabama주 West Fowl River 하구 패류서식장에 대한 위생학적 조사)

  • KIM Seong Jun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.7 no.3
    • /
    • pp.145-162
    • /
    • 1974
  • 시판되는 굴, 담치, 백합 등 패류는 깨끗한 수역에서 생산되어야 한다는 것은 공중보건상 매우 중요하다. 따라서 이들 서식해역에 대한 위생상태를 평가하는 것은 패류위생관리에 있어 가장 기본적인 일이다. 본 조사는 미국 Alabama주 West Fowl River 지역에 있어 패류위생관리상 양식장의 등급분류와 관련한 굴(Crassostrea virginica) 및 그 서식수의 위생학적 성상을 알기 위하여 실시되었다. 이 연구는 미국 국제개발처(AID) 연수계획에 의하여 이루워 졌음을 밝혀 둔다. 조사지역에 있어서의 감염원은 가옥, 소업체, 가축, 물새, 야생동물 등에 의한 일반적인 발기물과 배설물로 되어 있고 특별한 하수나 공업배출물은 없었다. 이 조사는 이 지방에 있어 건조기인 10월에 실시되었으며 조사기간중의 총 강우양은 0.08mm, 평균 기온은 $21.3^{\circ}C$, 바람은 동풍이 우세하였다. 저질은 뻘로 되어 있고 저호시 평균수침은 약 1m이며 조사기관중 평균 수온은 $26.0^{\circ}C$였다. 염분은 조사지점에 따라 상이하였으며 바다로 향한 강의 흐름에 따라 증가하고 평균 염분은 $18.0\~28.7\%$의 범위에 있었다. 해수 및 굴 양자의 Coliform 함양은 Fecal coliform 보다 시종 높았으며 Coliform 및 Fecal coliform의 수는 바다로 향한 강의 흐름에 따라 점차 감소하였다. 이것은 해수의 오염은 주로 지표수의 유입에 의한다는 것을 말하고 있다. 굴의 Coliform 및 Fecal coliform MPN은 해수의 그것보다 $11\~12$배 높았다. 조사수역에 설정한 7개소 Sampling station 중 오직 Station 7만이 패류양식장 허가해역의 세균학적 수질기준에 합당하였으며 굴의 Fecal coliform MPN은 시판용 패류의 세균학적 기준을 초과하고 있었다. EC test 양성시험관에서 분리된 세균의 $97.6\%$가 E. coli group로 나타나 EC test는 Echerichie Coli 시험에 매우 효과적인 방법임을 알 수 있다.

  • PDF