• Title/Summary/Keyword: 해석신호

Search Result 1,835, Processing Time 0.033 seconds

An Empirical Study on the IPO Firms' Financial Performance Achieved by R&D Expenditures Using Statistical Models (IPO Affect Firm's Performance after IPO, between KOSPI) (연구개발비가 기업경영 성과에 미치는 영향에 관한 연구 (IPO이전과 이후 코스피기업의 시계열 분석을 중심으로))

  • Park, Kyung-Joo;Yang, Dong-Woo
    • Journal of Korea Technology Innovation Society
    • /
    • v.9 no.4
    • /
    • pp.842-864
    • /
    • 2006
  • This paper deals with an empirical study to statistically analyse various financial performances of the selected IPO firms using their investments on research and development(R&D) as an independent variables. The major results of statistical analyses have come up with the followings: 1) The regression analyses for change in average annual total market stock value/total assets over that of R&D expenditures showed the positive relationship, However, those of sales volume and net assets per share showed negative without statistical significances. 2) The statistical analyses in effect of the 3-year average total market stock value/total assets over the 3-year average R&D expenditures resulted in the positive coefficients what are statistically significant at 95% level. 3) Another statistical analysis showed that the financial performances of the IPO finns with deferred assets were better than those of the firms without them. In sum, the degree of investment on R&D by the IPO firms are expected to positively affect their financial performances except the Finns without having proper original technologies.

  • PDF

$Dy^{3+}$$Eu^{3+}$ 함량비가 $Ca_{2-1.5x}SiO_4 $형광체의 발광 특성에 미치는 영향

  • Kim, Dong-Gyun;Jo, Sin-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.170-170
    • /
    • 2013
  • 형광체를 조명과 디스플레이 산업에 응용하기 위해서는 충분히 밝은 빛을 제공하는 형광체의 발광 세기가 중요한 변수이다. 이러한 발광 특성은 주로 모체 격자에 도핑 되는 활성제의 농도, 입자의 형상과 크기 분포의 균일성, 결정성에 따라 달라진다. 본 연구에서는 Ca2SiO4 모체 결정에 도핑한 활성제 Eu3+와 Dy3+ 이온의 농도를 변화시키면서 고상 반응법을 사용하여 높은 발광 효율을 갖는 Ca2-1.5xSiO4::Eux3+ 적색 형광체와 Ca2-1.5xSiO4:Dyx3+ 백색 형광체를 합성하였다. 특히, 활성제 Eu3+와 Dy3+ 이온 농도의 변화가 형광체의 결정 구조, 소성 온도, 입자의 표면 형상, 광학 스펙트럼의 발광 효율에 미치는 영향을 조사하여 최적의 합성 조건을 결정하였으며, 회절 신호의 반치폭과 발광 세기의 상호 관계를 조사하였다. Ca2-1.5xSiO4::Eux3+와 Ca2-1.5xSiO4:Dyx3+ 형광체 초기 분말 시료는 CaO (99.9% 순도), SiO2 (99.9%), Dy2O3 (99.9%)와 Eu2O3 (99.9%)인 화학 물질을 구입하여 초정밀 저울로 화학양론적으로 측정하였다. 이때 Eu와 Dy의 함량비는 x=0, 0.01, 0.05, 0.1, 0.15, 0.2 mol로 변화 시키면서 합성하였다. Ca2-1.5xSiO4: Dyx3+ 형광체 분말 시료의 경우에 소결 온도를 각각 $1000^{\circ}C$$1100^{\circ}C$로 달리하여 흡광과 발광 스펙트럼의 세기를 비교해 본 결과, 서로 다른 두 소결 온도에서 합성한 두 형광체 분말은 동일하게 Dy3+의 몰 비가 0.05 mol일 때 주 발광 스펙트럼의 세기는 최대값을 나타내었다. 파장 355 nm로 여기시킨 Dy3+ 함량비에 따른 Ca2-1.5xSiO4:Dyx3+ 형광체 분말의 발광 스펙트럼은 Dy3+ 함량비에 관계 없이 581 nm에서 가장 강한 황색 발광을 보였다. 함량비가 증가함에 따라 발광 스펙트럼의 변화가 관측되었는데, Dy3+의 몰 비가 0.01 mol~0.05 mol인 영역에서는 발광 세기가 증가하여 0.05 mol에서 최대를 나타내다가 Dy3+의 몰 비가 더욱 증가함에 따라 발광세기는 현저히 감소하는 경향을 나타내었는데, 이 현상은 농도 소광 현상으로 해석 할 수 있다. 이외에도, Eu3+와 Dy3+ 이온의 함량비와 소결 온도가 결정 입자의 크기와 흡광 스펙트럼에 미치는 결과를 조사하였다.

  • PDF

Insulin-like Growth Factor-I Regulates the FAT/CD36 Expression in C2C12 Skeletal Muscle Cells (C2C12 골격근 세포에서 FAT/CD36 발현 조절에 있어 Insulin-like growth factor-I이 미치는 영향)

  • Kim, Hye Jin;Yoon, Hae Min;Kim, Tae Young;Lee, Won Jun
    • Journal of Life Science
    • /
    • v.26 no.7
    • /
    • pp.758-763
    • /
    • 2016
  • Fatty acid transporters are key mediators of skeletal muscle lipid metabolism. Several protein groups have been implicated in cellular long-chain fatty acid uptake or oxidation, including fatty acid transporter proteins (FATPs), the plasma membrane fatty acid-binding protein (FABPpm), and the fatty acid translocase (FAT/CD36). FAT/CD36 is highly expressed in skeletal muscle and known to be regulated by various factors such as exercise and hormones. Insulin-like growth factor-I (IGF-I) is a well-known regulator of skeletal muscle cells. However, it has not been studied whether there is any interaction between IGF-I and FAT/CD36 in skeletal muscle cells. In this study, the effects of IGF-I treatment on FAT/CD36 induction were examined. Differentiated C2C12 cells were treated with 20 ng/ml of IGF-I at different time points. Treatment of C2C12 cells with IGF-I resulted in increased FAT/CD36 mRNA and protein expression. After 24 and 48 hr of IGF-I treatment, FAT/CD36 mRNA increased 89% and 24% respectively. The increase of both proteins returned to the control level after 72 hr of IGF-I treatment, suggesting that the FAT/CD36 gene is regulated pretranslationally by IGF-I in skeletal muscle cells. These results suggest that IGF-I can regulate the expression of FAT/CD36 in skeletal muscle cells. In conclusion, IGF-I induces a rapid transcriptional modification of the FAT/CD36 gene in C2C12 skeletal muscle cells and has modulating effects on fatty acid uptake proteins as well as oxidative proteins.

Design and Reliability Evaluation of 5-V output AC-DC Power Supply Module for Electronic Home Appliances (가전기기용 직류전원 모듈 설계 및 신뢰성 특성 해석)

  • Mo, Young-Sea;Song, Han-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.504-510
    • /
    • 2017
  • This paper presents an AC-DC power module design and evaluates its efficiency and reliability when used for electronics appliances. This power module consists of a PWM control IC, power MOSFETs, a transformer and several passive devices. The module was tested at an input voltage of 220V (RMS) (frequency 60 Hz). A test was conducted in order to evaluate the operation and power efficiency of the module, as well as the reliability of its protection functions, such as its over-current protection (OVP), overvoltage protection (OVP) and electromagnetic interference (EMI) properties. Especially, we evaluated the thermal shut-down protection (TSP) function in order to assure the operation of the module under high temperature conditions. The efficiency and reliability measurement results showed that at an output voltage of 5 V, the module had a ripple voltage of 200 mV, power efficiency of 73 % and maximum temperature of $80^{\circ}C$ and it had the ability to withstand a stimulus of high input voltage of 4.2 kV during 60 seconds.

Analysis of Ka Band Satellite Link Budgets and Earth Station G/T in Korea Rainfall Environment (국내 강우 환경에서 Ka 밴드 위성 링크 버짓 및 지구국 G/T 분석)

  • Choi, Hyeong-Jae;You, Kyoung-A;Park, Dae-Kil;Koo, Kyung Heon
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.2
    • /
    • pp.151-157
    • /
    • 2019
  • In geostationary satellite communications, which are widely used for broadcasting and communication, there is a path loss where the signal power on the path is largely reduced. It is important to consider rain attenuation when calculating link budget because the Ka band frequency is vulnerable to rain attenuation. In this study, rainfall trends were analyzed by using rainfall data from the year 2000 in four regions of Korea (Seoul, Incheon, Busan, Jeju) and the rainfall attenuation was calculated. This was used to analyse the satellite link budget and receiving performance for the down-link of the korea satellite COMS. In this study, the calculated G/T for the rainfall intensity of 0.5% per year using the rainfall data for 18 years increased by approximately $8.5dBK^{-1}$ compared to the ITU's zone-K rain model, and decreased by approximately $1dBK^{-1}$ compared to the precipitation data for 13 years from the TTA(Korea Telecommunications Technology Association). The results of this study can be used for the design of G/T in domestic-installed satellite ground station.

Clinical Microscopy: Performance, Maintenance and Laser Safety (임상에서의 현미경: 작동, 유지보수 및 레이저 안전)

  • Lee, Tae Bok
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.2
    • /
    • pp.125-133
    • /
    • 2019
  • A microscope is the fundamental research and diagnostic apparatus for clinical investigation of signaling transduction, morphological changes and physiological tracking of cells and intact tissues from patients in the biomedical laboratory science. Proper use, care and maintenance of microscope with comprehensive understanding in mechanism are fully requested for reliable image data and accurate interpretation for diagnosis in the clinical laboratory. The standard operating procedure (SOP) for light microscopes includes performance procedure, brief information of all mechanical parts of microscopes with systematic troubleshooting mechanism depending on the laboratory capacity. Maintenance program encompasses cleaning objective, ocular lenses and inner optics; replacement and calibration of light source; XY sample stage management; point spread function (PSF) measurement for confocal laser scanning microscope (CLSM); quality control (QC) program in fluorescent microscopy; and systematic troubleshooting. Laser safety is one of the concern for medical technologists engaged in CLSM laboratory. Laser safety guideline based on the laser classification and risk level, and advisory lab wear for CLSM users are also expatiated in this overview. Since acquired image data presents a wide range of information at the moment of acquisition, well-maintained microscopes with proper microscopic maintenance program are impulsive for its interpretation and diagnosis in the clinical laboratory.

Gas Sorption Analysis of Metal-organic Frameworks using Microresonators (마이크로진동자 기반 금속유기골격체의 기체 흡탈착 분석)

  • Kim, Hamin;Choi, Hyun-Kuk;Kim, Moon-Gab;Lee, Young-Sei;Yim, Changyong
    • Applied Chemistry for Engineering
    • /
    • v.33 no.1
    • /
    • pp.11-16
    • /
    • 2022
  • Metal-organic frameworks (MOFs) are porous materials with nano-sized pores. The degree of gas adsorption and pore size can be controlled according to types of metal ions and organic ligands. Many studies have been conducted on MOFs in the fields of gas storage and separation, and gas sensors. For rapid and quantitative gas adsorption/desorption analyses, it is necessary to form various MOF structures in uniform films on a sensor surface. In this review, some of representative direct methods for uniformly synthesizing MOFs such as MIL-53 (Al), ZIF-8, and Cu-BDC from anodized aluminum oxide, zinc oxide nanorods, and copper thin films, respectively on the surface of a microresonator are highlighted. In addition, the operation principle of quartz crystal microbalance and microcantilever, which are representative microresonators, and the interpretation of signals that change when gas is adsorbed to MOFs are covered. This is intended to enhance the understanding of gas adsorption/desorption analysis of MOFs using microresonators.

Statistical Techniques to Detect Sensor Drifts (센서드리프트 판별을 위한 통계적 탐지기술 고찰)

  • Seo, In-Yong;Shin, Ho-Cheol;Park, Moon-Ghu;Kim, Seong-Jun
    • Journal of the Korea Society for Simulation
    • /
    • v.18 no.3
    • /
    • pp.103-112
    • /
    • 2009
  • In a nuclear power plant (NPP), periodic sensor calibrations are required to assure sensors are operating correctly. However, only a few faulty sensors are found to be calibrated. For the safe operation of an NPP and the reduction of unnecessary calibration, on-line calibration monitoring is needed. In this paper, principal component-based Auto-Associative support vector regression (PCSVR) was proposed for the sensor signal validation of the NPP. It utilizes the attractive merits of principal component analysis (PCA) for extracting predominant feature vectors and AASVR because it easily represents complicated processes that are difficult to model with analytical and mechanistic models. With the use of real plant startup data from the Kori Nuclear Power Plant Unit 3, SVR hyperparameters were optimized by the response surface methodology (RSM). Moreover the statistical techniques are integrated with PCSVR for the failure detection. The residuals between the estimated signals and the measured signals are tested by the Shewhart Control Chart, Exponentially Weighted Moving Average (EWMA), Cumulative Sum (CUSUM) and generalized likelihood ratio test (GLRT) to detect whether the sensors are failed or not. This study shows the GLRT can be a candidate for the detection of sensor drift.

Fabrication of Radar Absorbing Shells Made of Hybrid Composites and Evaluation of Radar Cross Section (하이브리드 복합재를 이용한 레이더 흡수 쉘의 제작 및 레이더 단면적 평가)

  • Jung, Woo-Kyun;Ahn, Sung-Hoon;Ahn, Bierng-Chearl;Park, Seoung-Bae;Won, Myung-Shik
    • Composites Research
    • /
    • v.19 no.1
    • /
    • pp.29-35
    • /
    • 2006
  • The avoidance of enemy's radar detection is very important issue in the modem electronic weapon system. Researchers have studied to minimize reflected signals of radar. In this research, two types of radar absorbing structure (RAS), 'C'-type shell and 'U'-type shell, were fabricated using fiber-reinforced composite materials and their radar cross section (RCS) were evaluated. The absorption layer was composed of glass fiber reinforced epoxy and nano size carbon-black, and the reflection layer was fabricated with carbon fiber reinforced epoxy. During their manufacturing process, undesired thermal deformation (so called spring-back) was observed. In order to reduce spring-back, the bending angle of mold was controlled by a series of experiments. The spring-back of parts fabricated by using compensated mold was predicted by finite element analysis (ANSYS). The RCS of RAS shells were measured by compact range and predicted by physical optics method. The measured RCS data was well matched with the predicted data.

Finite element analysis for acoustic and temperature characteristics of a piezoelectric HIFU transducer at 10 MHz (10 MHz용 압전 HIFU 트랜스듀서의 음향 및 온도 특성에 대한 유한요소해석)

  • Jong-Ho Kim;Il-Gok Hong;Ho-Yong Shin;Hyo-Jun Ahn;Jong-In Im
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.33 no.3
    • /
    • pp.116-123
    • /
    • 2023
  • A high intensity focuses ultrasound (HIFU) is one of the emerging technologies in the biomedical field. The piezoelectric HIFU transducer is a device that utilizes the thermal energy generated by high ultrasound energy. Recently an operating frequency of the HIFU transducer is to expand above a 7 MHz. In this study, the acoustic pressures and temperature distributions in the tissue that generated by the HIFU transducer at 10 MHz were calculated with the finite element method. In addition, the pressure focusing characteristics of the device were analyzed. The geometrical variables are the piezomaterial thickness, lens shape, water height, and film thickness. The results shown that the acoustic pressure increased and saturated gradually when the height/radius (HL/RL) ratio of the lens increased. Moreover, the focal area was gradually decreases with HL/RL ratio of the lens. In case of the optimized HIFU transducer, the maximum pressure and temperature were analyzed about 19 MPa and 65℃ respectively. And the -3 dB focused distances in the axial and lateral direction are around 2.3 mm and 0.23 mm respectively.