• Title/Summary/Keyword: 해면골

Search Result 126, Processing Time 0.082 seconds

Estimation of Structural Properties from the Measurements of Phase Velocity and Attenuation Coefficient in Trabecular Bone (해면질골에서 위상속도 및 감쇠계수 측정에 의한 구조적 특성 평가)

  • Lee, Kang-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.7
    • /
    • pp.661-667
    • /
    • 2009
  • Trabecular-bone-mimicking phantoms consisting of parallel-nylon-wire arrays were used to investigate correlations of phase velocity and attenuation coefficient with structural properties in trabecular bone. Trabecular separation (Tb.Sp) of the 7 trabecular-bone-mimicking phantoms ranged from 300 to $900\;{\mu}m$ and volume fraction (VF) from 1.6% to 8.7%. Phase velocity and attenuation coefficient of the phantoms were measured by using a through-transmission method in water, with a matched pair of broadband unfocused transducers with a diameter of 12.7 mm and a center frequency of 1 MHz. Phase velocity and attenuation coefficient at 1 MHz decreased almost linearly with increasing Tb. Sp and increased almost linearly with increasing VF. The simple and multiple linear regression models with phase velocity and attenuation coefficient as independent vanables and Tb.Sp and VF as dependent variables demonstrated that the coefficients of determination for the prediction of VF were higher than those for the prediction of Tb.Sp. The results obtained in the trabecular-bone-mimicking phantoms consisting of parallel-nylon-wire arrays were consistent with those in human trabecular bone suggesting that the structural properties can be estimated from the measurements of phase velocity and attenuation coefficient in trabecular bone.

A New Species of Genus Jaspis (Demospongiae: Astrophorida: Ancorinidae) from Korea (한국 벽옥해면속 (보통해면강: 별해면목: 안코리니과)의 1신종)

  • Sim Chung Ja;Lee Kyung Jin
    • Animal Systematics, Evolution and Diversity
    • /
    • v.20 no.2
    • /
    • pp.155-159
    • /
    • 2004
  • A new species of the genus Jaspis (Demospongiae: Astrophorida: Ancorinidae), Jaspis coreana n. sp., is described on the specimen collected from Geomundo Island, Korea during September 1995 to March 2002 by SCUBA diving. This new species is characterized by two sponges association which is completely covered with Poecilastra wondoensis except for oscules. This new species is similar to J. wondoensis in its spicules type, but different in their spicules size, form of oscules and sponge colour. J. coreana has a large oxyasters and longer megascleres than J. wondoensis, oscule cluster and golden yellow colour in life.

Influence of Implant Designs on Initial Stability (임플란트의 형태가 초기 안정성에 미치는 영향)

  • Cho, Jae-Myoung;Kim, Chang-Seop;Yun, Mi-Jung;Jeong, Chang-Mo;Seo, Seung-U
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.1
    • /
    • pp.47-57
    • /
    • 2010
  • An undisturbed healing process without micromotion at the implant-bone interface is essential for achievement of osseointegration of dental implant. Therefore, initial stability was advocated as prerequisite for successful clinical outcome. Adequate bone quality and quantity were important to achieve initial stability and to prevent early failures. However there were few published data available regarding the effect of design change in implant geometry on initial stability of the implants. The purpose of the current study was to assess the initial stability of various designs of implants when placed into artificial bone materials of varying qualities and shapes of insertion holes. Within the scope of this study, the following results were drawn. Bone quality was major importance to achieve initial stability. Initial stability was higher on GS II which had additional design feature of double thread. With a tapered design of implant such as GS III showed a higher initial stability than straight one. An insertion hole with the similar shape of implant would lead to reduce a compression force on cortical bone and enhance a bone anchorage on cancellous bone.

Intraarticular Osteochondroma of the Phalanx of the Hand - A Case Report - (수지골에 발생한 관절내 골연골종 - 증례 보고 -)

  • Han, Chung-Soo;Pyo, Na-Sil;Lee, Jae-Hoon;Cho, Nam-Su;Park, Yong-Koo;Ryu, Kyung-Nam
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.6 no.2
    • /
    • pp.88-91
    • /
    • 2000
  • The osteochondroma is the most common benign bone tumor, which occupies 40% of the benign bone tumor. About 80% of lesions arise in the long bone of the extremities, particularly in the knee and the upper extremity. But the occurrence of an intraarticular osteochondroma is rare, especially in the interphalangeal joint. We report the case of a intraarticular osteochondroma which occurred at the interphalangeal joint of the hand in a 12-year-old male patient. The plain X-ray demonstrates an exostosis arising from intraarticular dorsal aspect of the proximal phalanx of the right middle finger. The excised mass was round, measuring $8{\times}3$mm in size and 1 mm in thickness with definite cartilage capsule.

  • PDF

Three Dimensional Optimum Design of Endosseous Implant in Dentistry by Multilevel Optimization Method (다단계 최적화기법을 이용한 치과용 골내 임플란트의 3차원 형상최적설계)

  • 한중석;김종수;최주호
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.04a
    • /
    • pp.143-150
    • /
    • 2004
  • An optimum design problem for endosseous implant in dentistry is studied to find best implant design. An optimum design problem is formulated to reduce stresses arising at the cortical as well as cancellous bones, in which sufficient design parameters are chosen for design definition that encompasses major implants in popular use. Optimization at once (OAO) with the large number of design variables, however, causes too costly solution or even failure to converge. A concept of multilevel optimization (MLO) is employed to this end, which is to group the design variables of similar nature, solve the sub-problem of smaller size for each group in sequence, and this is iterated until convergence. Each sub-problem is solved based on the response surface method (RSM) due to its efficiency for small sized problem.

  • PDF

Three Dimensional Optimum Design of Endosseous Implant in Dentistry by Multilevel Response Surface Optimization (다단계 반응표면법을 이용한 치과용 임플란트의 3차원 형상최적설계)

  • Han, Jung-Suk;Kim, Jong-Soo;Choi, Joo-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.7
    • /
    • pp.940-947
    • /
    • 2004
  • In this paper, an optimum design problem for endosseous implant in dentistry is studied to find best implant design. An optimum design problem is formulated to reduce stresses arising at the cortical as well as cancellous bones, in which sufficient design parameters are chosen for design definition that encompasses major implants in popular use. Optimization at once (OAO) with the large number of design variables, however, causes too costly solution or even failure to converge. A concept of multilevel optimization (MLO) is employed to this end, which is to group the design variables of similar nature, solve the sub-problem of smaller size for each group in sequence, and this is iterated until convergence. Each sub-problem is solved based on the response surface method (RSM) due to its efficiency for small sized problem.

Design of A Femoral IM Nail by analysis of Lateral Curve Angle (한국형 Femoral IM Nail 설계를 위한 표준 Lateral 휨각도 분석)

  • Kim, Sung-Min;Park, Sung-Yun;Lee, Man-Pyo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.11 s.176
    • /
    • pp.190-195
    • /
    • 2005
  • A Femur is the longest and largest bone which supports body in human musculoskeletal structure. Therefore, it may cause heavy loss of blood when it is suffered by a simple or complex fracture, and the complication is very dangerous with a possibility of severe tissue damage. In this study, the femoral cancellous angle change is estimated in order to design the Korean femoral IM nail. Generally, it is various in the size and curvature of femoral cancellous bone depending on patient's body dimension. Therefore surgeon has difficulty in fitting this femoral IM nail to the patient in the surgical procedure. In our study, we tries to estimate femoral lateral curve angle with more precise method based on CT image of the femur and utilize this information on the design of femoral IM nail for Korean patients.

Digital X-Ray Image Processing Method for Bone Mineral Density Measurement (골밀도 측정을 위한 Digital X-Ray 영상 처리 방법)

  • Han Ki-Seo;Yeom Jin-Su;Ryu Kwang-Ryol;Hur Chang-Wu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.239-242
    • /
    • 2006
  • 골다공증은 해면골의 골소주 두께 감소 및 파단에 기인한 전체적인 골질이 저하되는 질병이다. 골다공증을 예방과 조기진단을 하기 위해서는 골밀도를 측정하여야 한다. 보다 나은 이미지를 얻기 위해 Digital X-Ray로 골밀도를 측정하여 영상 처리하기 위한 방법을 제시한다. 먼저 디지털 센서에서 증감지와 렌즈간 거리가 가까워서 증감지의 중심과 주변부의 광 경로차이가 발생하므로 왜곡이 발생하는데 이를 균일화하여야 한다. 그리고 X-Ray장비의 조건에 따라 영상에 많은 차이를 보이므로 영상의 밝기를 보정하는 과정이 필수적이다.

  • PDF

Evaluation of Bone Micro-architecture based on histomorphometry (형태학적 지수에 기반한 뼈 미세구조의 평가)

  • Park, Sang-Cheol
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2005.05a
    • /
    • pp.862-865
    • /
    • 2005
  • 해면골에 대한 평가는 일반적으로 골밀도를 기준으로 평가하지만, 골밀도는 뼈의 특성을 70-80% 정도만 설명하는 것으로 알려져 있다. 이에 따라 골밀도로 설명이 되지 않는 나머지 특성을 뼈 미세구조의 형태학적 특성을 이용하여 설명하려는 노력이 생체역학 분야에서 오랫동안 있어 왔다. 본 연구는 CAD/CAM 분야의 feature extraction 기술을 이러한 생체역학 분야에 접목함으로써 뼈의 미세구조 평가를 위한 새로운 형태학적 지수 개발의 가능성을 탐색하고자 한다.

  • PDF