• Title/Summary/Keyword: 해면골

Search Result 126, Processing Time 0.032 seconds

Giant Bone Island of the Tibia - A Case Report - (경골에 발생한 거대 골 섬 - 증례 보고 -)

  • Park, Ho-Sung;Jang, Kyu-Yun;Lee, Sang-Yong;Kim, Jung-Ryul
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.10 no.1
    • /
    • pp.56-60
    • /
    • 2004
  • A bone island represents a focus of mature compact bone within the cancellous bone. It can be diagnosed based on characteristic clinical and radiologic features. The lesion is typically asymptomatic with a preference for the pelvis, femur, and other long bones. On the radiologic study, the lesion appears as an ovoid, round, or oblong homogeneously dense and sclerotic focus in the cancellous bone. Characteristic feature of this lesion is radiating bony streaks, known as "thorny radiations" or "pseudopodia". Most bone islands are small, and majority of the lesions measure from 0.1 to 2.0 cm. Giant bone island, defined as a diameter greater than 2 cm, has been rarely reported in the literature. We report a case of giant bone island measured by 10${\times}$1.7${\times}$1 cm in the diaphysis of right tibia in 31-year-old man.

  • PDF

A study on the micro-structural and biomechanical properties of trabecular bone in intertrochanteric region (대퇴골 전자간부 해면골의 미세구조적 특성과 생역학적 특성에 관한 연구)

  • Baek M.H.;Won Y.Y;Cui W.Q.;Kim K.K;Kim H.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.923-926
    • /
    • 2005
  • To investigate the relationship between BMD, micro-structural and mechanical properties in intertrochanteric trabecular bone, the PIXI-mus2 system, micro-CT and FE model were used. The purpose of this study were (1) to apply high-resolution imaging techniques (micro-CT imaging) in combination with new computer modeling techniques (FEA) to quantify 3D microstructural and biomechanical properties of trabecular bone in the intertrochanteric region, and (2) determine if the prediction of bone elastic constant can be improved with structural index.

  • PDF

A SURGICAL METHOD FOR THE EFFECTIVE TREATMENT OF CLEFT ALVEOLUS, ESPECIALLY FOR THE ELEVATION OF ALA BASE (효과적인 비익기저부의 회복을 위한 치조열 환자의 골이식 치험례)

  • Shin, Hong-Soo;Yoo, Yang-Keun;Choi, Young-Joon;Hwang, Soon-Jung
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.1
    • /
    • pp.64-68
    • /
    • 2002
  • The cleft alveolus is one of three parts in cleft deformity. The purpose of cleft alveolus bone grafting is the recovery of normal esthetics, occlusion and speech. If a bony defect is extended to the nasal floor, especially wide bony defect at the ala base, it is difficult to condense the cancellous bone during bone transplantation and to reconstruct the normal anatomy at the alar base. We treated with above mentioned cleft alveolus patients using the autogenous cortical bone effectively. We report this technique with two cases and the literatures review.

Evaluation of alveolar bone density by intraoral periapical radiography (구강 내 치근단 방사선 영상을 이용한 치조골 골밀도 측정의 유용성 평가)

  • Park, Eun-Jin;Kim, David-Hyungjin;Kim, Eun-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.233-238
    • /
    • 2014
  • Purpose: A method detecting change of jaw or alveolar bone density may be helpful in periodontal care, implant dentistry and evaluation of bone density of whole body. Materials and methods: In this study, bone density of intraoral periapical radiography using phantom-integrated XCP is compared with that of quantitative computed tomography (QCT). Results: Bone density of intraoral periapical radiography and the one measured by QCT showed high correlation (correlation coefficient = 0.92, P<.001) in alveolar bone, and relatively high correlation (0.73, P<.001) in cancellous bone. Conclusion: This study revealed possibility of scoring of bone density by intraoral periapical radiography.

Stress Analysis of Dental Implant System Using Homogenization Technique

  • Lee, Jin-hee;Koh, Chul-Su;Choi, Kui-won
    • The Journal of the Korean dental association
    • /
    • v.32 no.11 s.306
    • /
    • pp.805-814
    • /
    • 1994
  • 균질화기법을 적용하여 치과 임플란트 시스템에 대한 미세응력해석을 수행하였다. 균질화기법은 하악골내의 해면골과 같은 비균질 비등방성 구조체에 대한 물질모델을 설정하고 이를 이용하여 수치해석시 작은 계산량으로도 해면골조직의 미세단위까지의 응력해석을 가능케 하여준다. 균질화기법을 적용하여 계산된 해면골의 스트레스레벨은 기존의 방법으로 계산도니 수치보다 열배이상 높게 나타났는데, 이는 치과 임플란트 시스템의 응력상태에 대한 기존의 인식과 큰 차이를 보이고 있어 치과 임플란트 설계에 대한 전반적인 검토가 필요한 것으로 생각된다. 또한 균질화기법을 통하여 임플란트 시스템에 대한 측방력의 효과는 매우 크게 나타남을 확인할 수 있었고, 임플란트 시스템의 응력해석시 지나치게 단순화된 유한요소 모델을 사용함으로서 발생되는 오류가 지적되었다.

  • PDF

MICRO-CT를 이용한 쥐 대퇴골의 유한요소 해석

  • 변창환;오택열
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.296-296
    • /
    • 2004
  • 실험상의 어려움으로 인하여 생체역학 분야에서 유한요소법은 최선의 대안으로 여겨지고 있다. 또한, CT를 비롯한 여러 디지털 장비로부터 얻은 영상데이터를 이용하여 유한요소모델을 생성하는 방법으로 모델 생성 속도의 향상을 가져와 더욱 효율을 높이고 있다. 그러나, 일반 CT의 해상도를 가지고는 골(bone) 변화의 주를 이루고 있는 해면골(trabecular bone)의 변화를 파악하기에는 큰 어려움이 따른다. 이에 본 논문에서는 10~20$\mu\textrm{m}$ 정도까지의 해상도를 가지는 Micro-CT의 영상데이터를 이용하여 유한요소 모델을 생성하고 해석하여 보았다.(중략)

  • PDF

Effect of bone-implant contact pattern on bone strain distribution: finite element method study (골-임플란트 접촉 양상에 따른 골 변형 연구: 유한요소법적 연구)

  • Yoo, Dong-Ki;Kim, Seong-Kyun;Koak, Jai-Young;Kim, Jin-Heum;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.3
    • /
    • pp.214-221
    • /
    • 2011
  • Purpose: To date most of finite element analysis assumed the presence of 100% contact between bone and implant, which is inconsistent with clinical reality. In human retrieval study bone-implant contact (BIC) ratio ranged from 20 to 80%. The objective of this study was to explore the influence of bone-implant contact pattern on bone of the interface using nonlinear 3-dimensional finite element analysis. Materials and methods: A computer tomography-based finite element models with two types of implant (Mark III Br${\aa}$nemark$^{(R)}$, Inplant$^{(R)}$) which placed in the maxillary 2nd premolar area were constructed. Two different degrees of bone-implant contact ratio (40, 70%) each implant design were simulated. 5 finite element models were constructed each bone-implant contact ratio and implant design, and sum of models was 40. The position of bone-implant contact was determined according to random shuffle method. Elements of bone-implant contact in group W (wholly randomized osseointegration) was randomly selected in terms of total implant length including cortical and cancellous bone, while ones in group S (segmentally randomized osseointegration) was randomly selected each 0.75 mm vertically and horizontally. Results: Maximum von Mises strain between group W and group S was not significantly different regardless of bone-implant contact ratio and implant design (P=.939). Peak von Mises strain of 40% BIC was significantly lower than one of 70% BIC (P=.007). There was no significant difference between Mark III Br${\aa}$nemark$^{(R)}$ and Inplant$^{(R)}$ in 40% BIC, while average of peak von Mises strain for Inplant$^{(R)}$ was significantly lower ($4886{\pm}1034\;{\mu}m/m$) compared with MK III Br${\aa}$nemark$^{(R)}$ ($7134{\pm}1232\;{\mu}m/m$) in BIC 70% (P<.0001). Conclusion: Assuming bone-implant contact in finite element method, whether the contact elements in bone were wholly randomly or segmentally randomly selected using random shuffle method, both methods could be effective to be no significant difference regardless of sample size.

Correlations between Acoustic Properties and Bone Mineral Density in Bovine Femoral Trabecular Bone In Vitro (생체 외 조건의 소 대퇴골 해면질골에서 음향특성과 골밀도 사이의 상관관계)

  • Hwang, Kyo-Seung;Seo, Dong-Wan;Lee, Kang-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.4
    • /
    • pp.244-252
    • /
    • 2012
  • The purpose of the present study is to investigate the correlations between acoustic properties, such as speed of sound and normalized broadband ultrasound attenuation, and bone mineral density in femur with high fracture risk. The speed of sound and the normalized broadband ultrasound attenuation in 15 bovine femoral trabecular bone samples in vitro were measured by using a through-transmission method with two matched pairs of ultrasonic transducers with center frequencies of 0.5 and 1.0 MHz. The volumetric bone mineral density of the trabecular bone samples was measured by using micro-computed tomography. The bone mineral density exhibited strong correlations with both the speed of sound and the normalized broadband ultrasound attenuation measured by using the 0.5 and the 1.0 MHz transducers. The highest correlation was found between the bone mineral density and the normalized broadband ultrasound attenuation measured by using the 0.5 MHz ultrasonic transducers. The results suggest that the acoustic properties measured in the femur in vitro can be used as indices for the prediction of femoral bone mineral density.

Load Sharing Ratios Between the Cortex and Centrum in a Lumbar Vertebral Body with aging using Finite Element Method (유한 요소 법을 이용한 노화에 따른 요추의 피질 골과 해면 골 간의 하중 분담 비율)

  • Lim, JongWan
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.2
    • /
    • pp.90-103
    • /
    • 2016
  • This research was aimed to analyze load sharing ratios between cortical shell and trabecular bone of a degraded lumbar vertebra with aging, and also evaluate elastic moduli assigned into an FE model, using finite element method. For the better analysis of trabecular bone, effective elastic moduli, that is, nominal elastic moduli divided by the volumetric porosities was used. The elastic moduli of the cortical shell suitable for the trabecular bone were obtained from the equations on the basis of idealized stress-strain relations, including areal porosities. To minimize numerical errors, p-element was used. Using eight parameters that refer to some published papers, the geometry of L3 with a removed posterior part. After the constant compressive displacement was applied, the load sharing ratios were obtained by using both every elastic strain energy and every vertical force between two bones in each 8-volume. As results, 1) according to an increase in age from 20-year to 80-year, load sharing ratios of trabecular bone decreased from 55% to 49%; 2) the maximal ratios of each bone were occurred in the mid-plane of centrums and the endplate of cortical shells, respectively; 3) effective elastic moduli assigned into a porous centrum/cortex were found to be adequate; 4) for load sharing ratios, the difference of two methods showed that the total ratios were almost same within less than 1% but the partial ratios at every depth were more or less different each other.

Effect of Titanium Prosthesis on Computed Tomography Measurements of Bone Mineral Density

  • Han, S.M.;Zude Feng
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.177-182
    • /
    • 1998
  • This study investigated the effects of a titanium prosthesis, malalignment, field of view, and distal flare of titanium prosthesis on computed tomography( CT) measurements of home mineral density. Eight femora and eight tibiae from fresh male cadavers were used. Fifteen pieces of cancellous bone from the proximal tibiae were milled into rectangular parallelepipeds. Parallelepipeds and femors were scanned with and without titanium prosthesis when centered in the gantry of the CT scanner and malaligned, respectively. Image data were then reconstructed with field of view of 10 and 30 cm. Bone mineral density(BMD) values were obtained from CT images using C-MED software. The effects of titanium prosthesis, malalignmetn, and field of view were investigated. When bone was centered in the gantry of the CT scanner, the mean relative difference of BMD measurements caused by a titanium prosthesis was less than 1% for both cortical and cancellous bone. Field of view had negligible effect on BMD measurements as well. Malalignment and distal flare of prosthesis, however, caused a significant difference in BMD measurements(p<0.0001). The titanium prosthesis did not interfere with malalignment combining the existence of a titnium prosthesis on BMD measurements was significant.

  • PDF