• Title/Summary/Keyword: 한국EMC

Search Result 752, Processing Time 0.028 seconds

A Study in EMC Environment Measuring of Marine Ship (선박의 EMC 환경 측정에 관한 연구)

  • Kim, Dong-Seek;Cho, Hyung-Rae;Min, Kyeong-Sik
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.29 no.1
    • /
    • pp.141-146
    • /
    • 2005
  • Recently, the accidents on the sea have arisen due to the increase of the nautical traffic and the digitization of equipments for marine. Therefore, IMO(International Maritime Organization) have provided the recommendation of EMI and EMS for radio communication and equipments of marine from SOLAS cobvention at July 1st 2002. In this paper, we measured EMC environment on the HANBADA, which is Korea Maritime University training ship, for basic EMC environment of a ship. The measuring point was Bridge and Engine Control Room of the ship, we measured the test point that was set at random. Measured Band is from 30 MHz to 2 GHz, polarization measurement is processed both vertical and horizontal polarizaion. We analysed the results in consideration of permissible criteria.

  • PDF

The Influence of Leadframe Oxidation on the Cu/EMC Interface Adhesion (리드프레임의 산화가 Cu/EMC 계면 접착력에 미치는 영향)

  • Jo, Sun-Jin;Baek, Gyeong-Uk
    • Korean Journal of Materials Research
    • /
    • v.7 no.9
    • /
    • pp.781-788
    • /
    • 1997
  • Cu/EMC 계면 접착력에 미치는 산화의 규명하기 위해 리드프레임의 저온 산화에 대하여 조사하였다. 이전의 보고와 달리, 저온에서도 Cu$_{2}$O위에 CuO산화물이 형성되어 Cu/Cu$_{2}$O(NiO)/Cu(NiO)/air의 산화층 구조를 나타내었다. Cu/EMC 계면 접착력은 산화가 진행됨에 따라 산화 초기에 급격히 증가하다 최대값에 이르고, 이후의 계속적인 산화로 감소하는 양상을 보였다. 접착력은 산화 온도나 리드프레임의 종류보다 산화막의 두께에 밀접한 상관 관계를 나타내었다. 최대 계면 접착력이 얻어지는 산화막의 두께는 리드프레임의 종류보다 산화막의 두께에 밀접한 상관 관계를 나타내었다. 최대 계면 접착력이 얻어지는 산화막의 두께는 리드프레임의 종류와 무관하게 대략 20nm 와 30nm 사이에 존재하였다. 산화 초기의 접착력 증가는 산화로 인한 EMC에 대한 젖음성의 증가와 기계적 고착 효과의 증가에 기인하였다. 리드프레임과 EMC의 파괴 표면에 대한 AES, XPS 분석으로 부터, 산화막의 두께가 얇을 때에는 Cu$_{2}$O//CuO의 계면 파괴 + EMC 자체 파괴가 복합적으로 발생함을 알 수 있었다. 반면에 과도한 산화로 낮을 접착력을 나타내는 시편은 Cu/Cu$_{2}$/O 계면의 파괴를 나타냈다.

  • PDF

A EMC Certification Environment Management System using USN (USN 기반 EMC 인증환경 관리 시스템)

  • Choi, Jong-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.7
    • /
    • pp.207-212
    • /
    • 2008
  • In EMC(electromagnetic compatibility) certification, the facilities and equipments have been considered as important qualification for registration of EMC certification business. In future, the certification environment is also supposed to be restricted Strictly. Many organizations have made on attempt to establish, certification environment as a international standard. Therefore, in order to enhance the competitive powers of domestic certification industry, a real-time system which can be measure automatically and remotely the temperature, humidity, illumination, CO/CO2, magnetic field, and human sensing is proposed in this paper. This system can also maintain the appropriate measurement environment by using USN (ubiquitous sensor network). The availabilities are confirmed through the experiment.

  • PDF

IEC / TC 77 동향

  • 정낙삼
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.7 no.1
    • /
    • pp.14-21
    • /
    • 1996
  • 전자기적합성 전문위원회(TC 77 : Electromagnetic Compatibility)는 현재 IEC/TC중 에서 가장 활동이 활발한 TC 가운데 하나이다. 이는 거의 모든 산업 분야에 중요한 문제로 대두 되고 있는 EMC의 표준화를 담당하고 있기 때문이다. 이 글에서는 IEC/TC 77의 배경 및 업무 등 을 간단히 살펴 보고, EMC 표준화 전반에 걸쳐 관련되고 모든 EMC 규격의 바탕이 되는 '기본 E MC 간행물(IEC 1000 시리스)'의 현황을 알아 본다. 여기서는 IEC 1000 시리스 외에도 EMC 관련 이 많은 CISPR 규격 등 몇개를 포함시켰으나, SC 77C(HEMP) 관련 규격은 생략하였다.

  • PDF

Determination of Equilibrium Moisture Content of Outdoor Woods by Using Hailwood-Horrobin Equation in Korea (Hailwood-Horrobin 방정식을 이용한 한국의 야외 목재평형함수율 결정)

  • Ra, Jong-Bum
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.6
    • /
    • pp.653-658
    • /
    • 2014
  • This research was carried out to investigate equilibrium moisture content (EMC) of wood in outdoor locations in Korea. EMC was calculated using Hailwood-Horrobin equation for 73 different locations in Korea using the 1981 to 2010 climate normal data obtained from the Korea Meteorological Admnistration (KMA). Daegu showed the lowest values of EMC (11.5), and the highest EMC values (15.8) was found in Heuksando. Considering the season effect, summer (June, July, August) showed the highest values 15.3, followed by autumn (September, October, November) 13.7, winter (December, January, February) 12.2, and spring (February, March, April) 12.0. Monthly EMC showed the lowest values 11.6 in April and July showed the highest EMC values 16.1. The smallest changes in monthly EMC were found in Jeju island and Heuksando showed the largest values 8.7. A proper wood drying based on average EMC is more required in the regions with larger variation in EMC.

Factors associated with unexpected revisit to an emergency medical center (예고되지 않은 응급의료센터 재방문에 영향을 미치는 요인 분석)

  • Lim, Mi-Sun;Kang, Hye-Young;Sub, Gil-Joon;Hong, Joon-Hyun
    • Korea Journal of Hospital Management
    • /
    • v.10 no.2
    • /
    • pp.64-80
    • /
    • 2005
  • The objectives of this study were to identify factors associated with unexpected revisit to an emergency medical center (EMC) located in Seoul and to examine reasons for revisit. During March, June, September and December, 2002, a total of 168 patients had unexpected revisits to the EMC within 48 hours of a previous discharge. As a 1:1 matched control, we included 136 patients who: discharged from the EMC during the same time period: did not return to the EMC; had the same diagnosis and age(${\pm}5$) with the case. In this study, factors associated with unexpected revisits were defined as characteristics of a previous discharge, which were classified into three: sociodemographic, EMC visit-related, and discharge management factors. Reasons for revisit were categorized into disease, physician, patients, and system-related factors. Data were collected by medical chart review with assistance from clinicians of the EMC. Logistic regression results showed that patients who headed home after discharge without follow-up schedule had a 27.6 times higher risk of revisiting EMC than those who were hospitalized following EMC visit. Patients discharged on his own will had a 5.9 times higher risk of revisiting than those discharged following physician's advice. Patients requiring continual observation at the time of discharge were more likely to revisit by 8.7 times than those discharged with improved condition. About 69.13% of the revisits were due to disease-related factors, followed by 13.90% due to patient-related factors, 8.64% due to system-related factors, and 8.34% due to physician-related factors. It appears that the most significant factors influencing revisits are discharge management factors such as patient's condition at discharge, whether the discharge was accorded with physician's advice, and whether returning home without follow-up schedule. Therefore, appropriate discharge management is necessary to prevent EMC revisit.

  • PDF

A Study on Design and Fabrication of Broad-Band EMC Filter for PC (PC용 광대역 EMC 필터의 설계 및 제작에 관한 연구)

  • Kim, Dong-Il;Jung, Sang-Wook;Kim, Min-Jung;Jeon, Joong-Sung
    • Journal of Navigation and Port Research
    • /
    • v.28 no.8
    • /
    • pp.715-719
    • /
    • 2004
  • This paper deals with EMC filter for a personal computer(PC). A PC contains many sources of noise inside and out, with many connected cables. High noise levels are also emitted from the PC because of high-speed signals. So radiated noise from the computer body may sometimes cause problems. Therefore, we design and fabricate an electromagnetic compatibility (EMC) filter for PC, which is composed of feed-through capacitors and ferrite beads with high permeability. Through extensive test, the proposed EMC filter is shown to have excellent differential-mode and common-mode noises filtering characteristics above 30 dB in the frequency band from 10 MHz to 1.5 GHz. The immunity characteristics are improved more than 10 to 30 dB over the frequency band from DC to 1.8 GHz.

Trends in Electromagnetic Compatibility (EMC) Technology to Secure Electromagnetic Safety in the Critical Facilities (주요시설의 전자파 안전성 확보를 위한 전자파적합성(EMC) 기술)

  • Kwon, J.H.
    • Electronics and Telecommunications Trends
    • /
    • v.33 no.3
    • /
    • pp.41-50
    • /
    • 2018
  • In order to ensure the electromagnetic safety of a complex facility equipped with a variety of electric and electronic equipment, the European Union (EU) has enacted and applied the Electromagnetic Compatibility Directive (EMC Directive 2004/108/EC) to a fixed installation. This paper introduces the regulations and techniques related with electromagnetic compatibility (EMC) engineering applied to a fixed installation, which is used to prevent a malfunction of critical equipment and systems caused by unwanted electromagnetic waves and to operate the facilities with stability.