• Title/Summary/Keyword: 한국 제4기학회

Search Result 2,993, Processing Time 0.039 seconds

Major Molybdenum Mineralization and Igneous Activity, South Korea (남한의 주요 몰리브덴 광화작용과 화성활동)

  • Choi, Seon-Gyu;Koo, Min-Ho;Kang, Heung-Suk;Ahn, Yong-Hwan
    • Economic and Environmental Geology
    • /
    • v.44 no.2
    • /
    • pp.109-122
    • /
    • 2011
  • The major Mo deposits in South Korea were formed during the Jurassic Daebo orogeny, the Late Cretaceous and the Tertiary post-orogenic igneous activities, and are characterized by a variety of genetic types such as pegmatite, greisen, skarn, porphyry and vein types. The Jangsu mine is a pegmatite-style deposit which is genetically related to the Jurassic ilmenite-series two-mica granite with the Mo mineralization age of $159.6{\pm}4.5$ Ma. The Geumseong mine occurs as a skarn/porphyry-style deposit associated with highly fractionated granite. Its age of Mo mineralization within aplitic cupola is about 96.5~l07.5 Ma. The Yeonil mine is a porphyry-style deposit, and the Geumeum mine is a veinlet-style deposit along the fracture zone with their mineralization ages of $58.4{\pm}1.6$ and $54.4{\pm}1.2$ Ma, respectively. The contrasts in the style of Mo mineralization in Korea reflect the different environment of the related magmatism. The Jurassic mineralization, being related to deep-seated granitoids, occurs as a pegmatite-style deposit, whereas the Cretaceous one, being related to subvolcanic granitoids, occurs as skarn/porphyry/vein-type ore deposits. The Tertiary Mo mineralization has a close relationship with the igneous activities associated with the Tertiary basin formation along the east coast, Korean peninsular.

Production of Biosurfactant by Pseudomonas sp. SW1 for Microbial Remediation of Oil Pollution (유류오염방제를 위한 Pseudomonas sp. SW1로부터 생물계면활성제의 생산)

  • Son, Hong-Joo;Suk, Wan-Su;Lee, Geon;Lee, Sang-Joon
    • Korean Journal of Microbiology
    • /
    • v.33 no.3
    • /
    • pp.193-198
    • /
    • 1997
  • Microorganisms capable of producing biosurfactant were isolated from oil-contaminated soils and seawater. Among them, the selected strain SW1 was identified as Pseudomonas sp. by taxonomical characteristic tests, and so tentatively named Pseudomonas sp. SWI. The optimal temperature and initial pH for biosurfactant production were TEX>30^{\circ}C.$ and 7.0, respectively. The optimal medium composilion for the production of biosurfactant by Pseudomonas sp. SW1 were hexadecane of 2.0%, yeast extract of 0.04%, $K_{2}HPO_4$ of 0.02%, $KH_2PO_4$ of 0.03% and $MgSO_4$ center dot $7H_2O$ of 0.04%, respectively. Under the above conditions, minimum wrface tension was 32 mN/m after incubation of 2 days. The biosurfactant was produced during initial stationary phase in the optimal medium. Pseudotnonas sp. SWl utilized various hydrocarbons such as Bunker oils, n-alkanes and branched alkanes as a sole carbon source.

  • PDF

Deformation Characteristics of Zircaloy-4 Fuel Cladding due to Oxidation in Environment of High Temperature and Steam (고온, 수증기 속에서 산화된 질칼로이-4 핵연료 피복관의 변형 특성에 관한 연구)

  • Jung, Sung-Hoon;Suh, Kyung-Soo;Kim, In-Sup
    • Nuclear Engineering and Technology
    • /
    • v.18 no.3
    • /
    • pp.218-227
    • /
    • 1986
  • Studies were conducted to determine the extent of oxidation and same of the mechanical property changes of Zircaloy-4 fuel cladding after it was exposed to hot steam environment. The purpose of these tests was to provide some informations on the embrittlement behavior of CANDU type fuel cladding, which could be experienced under the loss-of-coolant accident conditions. The Zircaloy fuel cladding tubes were exposed in a steam environment at the temperature of 90$0^{\circ}C$, 1,00$0^{\circ}C$. The growth of the ZrO$_2$ layer combined with an oxygen rich $\alpha$-phase layer into the Zircaloy tube material was found as a function of time t and temperature of steam exposure, E=1.1√Dt+0.002 where D is a temperature dependent diffusion coefficient. The tensile strength of the specimens exposed for a short period increased but decreased continuously with further exposure. The circumferential elongation was drastically changed with the exposure time while the hoop strength did't decrease greatly. The X-ray measurement of preferred orientation of the Zircaloy tube material indicated that grains in the as received tube were oriented such that the poles of the basal (0001) planes were predominantly radial, while the poles of the basal plane in the tube materials heattreated at 1,00$0^{\circ}C$ were oriented tangentially. It appears that this reoriented texture may contribute to lessening the decrease of the hoop strength of the heat treated Zircaloy tube material.

  • PDF

Investigation of fault in the Kyungju Kaekok-ri area by 2-D Electrical Resistivity Survey (2차원 전기비저항 탐사를 이용한 경주 개곡리 지역의 단층조사)

  • Lee, Chi-Seop;Kim, Hee-Joon;Kong, Young-Sae;Lee, Jung-Mo;Chang, Tae-Woo
    • Geophysics and Geophysical Exploration
    • /
    • v.4 no.4
    • /
    • pp.124-132
    • /
    • 2001
  • Electrical resistivity survey has been conducted for delineating geological fault structure in Kaekok-ri near Kyungju. In general, electrical resistivity survey has an advantage of searching buried faults and its traces compared with other geophysical survey methods. Distribution of electrical conductivity in the ground is influenced by the ratio of pores, groundwater and clay minerals. These properties are evidenced indirectly to explain for weathering condition, faults and fracture Bones. Thus the electrical resistivity survey can be an effective method to find buried faults. We have carried out two dimensional (2-D) interpretation by means of smoothness-constrained least-squares and finite element method. Field data used in this paper was acquired at Kaekok-ri, Wuedong-eup, Kyungju-si, where is Ulsan Fault and is close to the region in which debatable quaternary fault traces were found recently. The dipole-dipole array resistivity survey which could show the 2-D subsurface electrical resistivity structure, was carried out in the area with three lines. The results showed good property of fault, fracture zone and fault traces which we estimated were congruous with the results. Through this study, 2-D electrical resistivity survey interpretation for fault is useful to apply.

  • PDF

Relationship between serum 25-hydroxyvitamin D and chronic obstructive pulmonary disease in males in the fifth Korean national health and nutrition examination survey (제5기 국민건강영양조사 자료 중 남성에서 혈청 중 25-hydroxyvitamin D와 만성폐쇄성폐질환의 상관관계)

  • Jung, In Kyung
    • Journal of Nutrition and Health
    • /
    • v.47 no.5
    • /
    • pp.321-329
    • /
    • 2014
  • Purpose: The aim of this study was to determine the relationship between serum concentrations of 25-hydroxyvitamin D [25(OH)D] and chronic obstructive pulmonary disease (COPD) prevalence. Methods: The analysis was performed using data from the Fifth Korean National Health and Nutrition Examination Survey, a cross-sectional survey of the Korean civilian population conducted from 2010 to 2012. The analyses were restricted to males who were 40 years of age and above. Complex sample multiple logistic regression analyses were used to examine the associations of COPD prevalence with 25(OH)D and other factors. Results: $FEV_1/FEV_6$ varied significantly with smoking status, age, household income, education level, occupation, body mass index (BMI), and physical activity (p < 0.05). In univariate analysis, smoking status, BMI, household income, education level, and occupation showed association with COPD (p < 0.05), but vitamin D was not associated with COPD (p = 0.078). However, when adjusted with smoking status, household income, education level, occupation, BMI, age, and smoking index, the lowest quartile of 25(OH)D showed OR 1.643 (95% CI 1.161-2.236) compared to 3rd quartile (p = 0.024). Conclusion: A significant relationship was observed between serum concentration of 25(OH)D and COPD.

A Study on the Bond Strength of BCB-bonded Wafers (BCB 수지로 본딩한 웨이퍼의 본딩 결합력에 관한 연구)

  • Kwon, Yongchai;Seok, Jongwon;Lu, Jian-Qiang;Cale, Timothy;Gutmann, Ronald
    • Korean Chemical Engineering Research
    • /
    • v.45 no.5
    • /
    • pp.479-486
    • /
    • 2007
  • Four point bending is used to study the dependences of bond strength of benzocyclobutene(BCB) bonded wafers and BCB thickness, the use of an adhesion promoter, and the materials being bonded. The bond strength depends linearly on BCB thickness, due to the thickness-dependent contribution of the plastic dissipation energy of the BCB and thickness independence of BCB yield strength. The bond strength increases by about a factor of two with an adhesion promoter for both $2.6{\mu}m$ and $0.4{\mu}m$ thick BCB, because of the formation of covalent bonds between adhesion promoter and the surface of the bonded materials. The bond strength at the interface between a silicon wafer with deposited oxide and BCB is about a factor of three higher than that at the interface between a glass wafer and BCB. This difference in bond strength is attributed to the difference in Si-O bond density at the interfaces. At the interfaces between plasma enhanced chemical vapor deposited (PECVD) oxide coated silicon wafers and BCB, and between thermally grown oxide on silicon wafers and BCB, 12~13 and $15{\sim}16bonds/nm^2$ need to be broken. This corresponds to the observed bond energies, $G_0s$, of 18 and $22J/m^2$, respectively. Maximum 7~8 Si-O $bonds/nm^2$ are needed to explain the $5J/m^2$ at the interfaces between glass wafers and BCB.

Distribution and Characterization of the Neurosteroid Acyltransferase from the Bovine Brain (소의 뇌에서 Neurosteroid Acyltransferase의 분포 및 특성에 관한 연구)

  • Park, In-Ho;Jo, Sung-Jun;Jo, Do-Hyun
    • Applied Biological Chemistry
    • /
    • v.40 no.2
    • /
    • pp.112-116
    • /
    • 1997
  • The enzymatic properties as well as its distribution in the cerebral region and subcellular organells were investigated for the neurosteroid acyltransferase from the bovine brain, which synthesize the fatty acid esters of the neurosteroids. The cerebellum region was the highest in NSAT activity while the cerebrum was the lowest with 50% of the cerebellar activity. The NSAT was found to be mainly localized in the microsomal fraction. The optimal temperature and pH were $40^{\circ}C$ and 4.9, respectively. When $^3H-DHEA$ was utilized as substrate, the $K_m$ and $V_{max}$ was $32.6\;{\mu}M$ and 4.86 nmole/mg protein/h, respectively. Under the same condition pregnenolone$({\Delta}^5P)$ was a competitive inhibitor with $K_i=22.8\;{\mu}M$ and testosterone was a uncompetitive inhibitor with $K_i=22.8\;{\mu}M$. This may suggest that the NSAT has a different conformation in the acylation of the ${\beta}-hydroxyl$ group at C-3 and C-17.

  • PDF

Cure Monitoring of Am Epoxy-Anhydride System by Means of Fluorescence Spectroscopy (형광분석기를 이용한 에폭시-산무수물계의 경화 모니터링)

  • 조동환;김득수;이종근
    • Polymer(Korea)
    • /
    • v.25 no.2
    • /
    • pp.199-207
    • /
    • 2001
  • In the present study the cure behavior of diglycidyl ether of bisphenol-A(DGEBA) using an anhydride-based hardener in the presence of N,N-dimethyl benzyl amine (BDMA) or 1-cyanoethyl-2-ethyl-4-methyl imidazole (2E4MZ-CN) as an accelerator has been monitored and interpreted from the viewpoint of photophysical properties by means of fluorescence spectroscopy. To do this, 1,3-bis-(1-pyrene)propane (BPP) was well incorporated in the epoxy resin system by mechanical blending. The BPP probe, which is very sensitive to conformational change of the molecule influenced by the surrounding medium, successfully formed intramolecular excimer fluorescence. It is susceptible to the micro-viscosity or local viscosity and molecular mobility according to the epoxy cure. The cure behavior was explained with monomer fluorescence intensity ($I_{M}$ ), excimer fluorescence intensity ($I_{E}$ ) and $I_{M}$ /$I_{E}$ ratio as a function of cure time, cure temperature and accelerator. The present work agreed with the previous report on the cure behavior of an epoxy-anhydride system studied using DSC or torsion pendulum method. This study also suggests that the use of fluorescence technique may provide information on cure behavior of a thermosetting resin in a low temperature region, which has not been well interpreted by other analytical methods.

  • PDF

Interpretation of Geophysical Well Logs from Deep Geothermal Borehole in Pohang (포항 심부 지열 시추공에 대한 물리검층 자료해석)

  • Hwang, Se-Ho;Park, In-Hwa;Song, Yoon-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.4
    • /
    • pp.332-344
    • /
    • 2007
  • Various geophysical well logs have been made along the four deep wells in Pohang, Gyeongbuk. The primary focus of geophysical well loggings was to improve understanding the subsurface geologic structure, to evaluate in situ physical properties, and to estimate aquifer production zones using fluid temperature and conductivity gradient logs. Especially natural gamma logs interpreted with core logs of borehole BH-1 were useful to discriminate the lithology and to determine the lithologic sequences and boundaries consisting of semi-consolidated Tertiary sediments and intrusive rocks such as basic dyke and Cretaceous sediments. Cross-plot of physical properties inferred from geophysical well logs were used to identify rock types such as Cretaceous sandstone and mudstone, Tertiary sediments, rhyolite, and basic dyke. The temperature log indicated $82.51^{\circ}C$ at the depth of 1,981.3 meters in borehole BH-4. However, considering the temperature of borehole BH-2 measured under stable condition, we expect the temperature at the depth in borehole BH-4, if it is measured in stable condition, to be about 5 or $6^{\circ}C$ higher. Several permeable fractures also have been identified from temperature and conductivity gradient logs, and cutting logs.

Relationship between usage of removable denture and depression in Korean adults with loss of multiple teeth: A cross-sectional study using the seventh Korea National Health and Nutrition Examination Survey (다수 치아를 상실한 한국 성인에서 가철성 의치의 장착 여부와 우울증의 연관성: 국민건강영양조사 제 7기 자료를 활용한 단면 연구)

  • Shim, Jaeseung;Lee, Younghoo;Hong, Seoung-Jin;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock;Paek, Janghyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.1-10
    • /
    • 2021
  • Purpose: The purpose of this study is to evaluate the relationship between removable denture and depression. This study aims to investigate the relationship between depression and each group by dividing them into a group that were using removable dentures and a group that needed removable dentures but were not using removable dentures. Materials and methods: This study was conducted using raw data from the 7th Korea National Health and Nutrition Examination Survey (KNHNES). By using variables related to the state of the prosthesis and the need for prosthesis among oral examination data, the oral examination data were classified into two groups; group using removable denture and group in need of removable dentures. In addition, the variables of depression were classified into normal (0-4), mild depression (5-9), moderate depression (10-19), and severe depression (20-27) using the values of PHQ-9. For statistical analysis, logistic regression analysis was performed using SAS 9.4. Results: In the group in need of removable dentures, the risk of severe depression was statistically and significantly higher than the group using removable dentures. Conclusion: In patient who have lost multiple teeth, rehabilitation of the missing area with removable dental prosthesis is expected to decrease the occurrence of severe depression.