• Title/Summary/Keyword: 한국형 RE100

Search Result 30, Processing Time 0.028 seconds

Prospects of Cumulative Installed Power Capacity of Domestic Offshore Wind Projects for K-RE100 (K-RE100 이행에 필요한 국내해상풍력단지 누적 설치량 전망 연구)

  • Hong Goo Kang;Byung Ha Kim;Hun Jo Kim;Chang Jo Yang;Hae Chang Jeong
    • New & Renewable Energy
    • /
    • v.20 no.2
    • /
    • pp.44-54
    • /
    • 2024
  • The objective of this study was to contribute to domestic offshore wind farms by reasonably predicting the expected completion time and installed power generation capacity of offshore wind projects in South Korea. Offshore wind power is drastically regarded as a core tool for clean energy transition and industrial decarbonization in the fight against the climate crisis globally. Especially in South Korea offshore wind power is the main tool in partaking in RE100 and K-RE100, and the Korean government aims to install 14.9 GW of offshore wind farms by 2030. However, this seems to have been significantly delayed due to the complex process of obtaining permits for offshore wind power in Korea. Thus, a reasonable prediction of power generation and a timeline for the final construction are imperative. To establish the delay time for permit licenses, classified location factors were included into site analysis. These factors comprised reviews of transmission and military operability, environmental impact assessment, maritime traffic safety examination, wind resource assessment and an analysis of current offshore wind projects. According to the analysis, the majority of offshore wind projects currently being developed in Korea are predicted to be delayed by 3-5 years as they are among the criteria included in key discussion points for obtaining permits. The cumulative installed power capacity and annual power generation after construction are expected to be 37 GW and 97 TWh respectively.

Characteristics of Piezoelectric Microspeakers according to the Material Properties (물성변화에 따른 압전형 마이크로스피커의 특성)

  • Jeong, Kyong-Shik;Park, Jong-Sun;Cho, Hee-Chan;Yi, Seung-Hwan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.37-38
    • /
    • 2007
  • This paper reports the characteristics of piezoelectric microspeakers that are audible in open air with high quality piezoelectric AlN thin film according to the materials properties. When we use a tensile-stressed silicon nitride diaphragm as a supporting layer, the Sound Pressure Level (SPL) is relatively small. However, the SPL of the fabricated microspeakers that have compressive-stressed composite diaphragm show higher output pressure than those of tensile-stressed diaphragm. It produces more than 60dB from 100Hz to 15kHz and the highest SPL is about 100dB at 9.3kHz with 20 Vpeak-to-peak sinusoidal input biases and at 10 mm distances from the fabricated microspeakers to the reference microphone.

  • PDF

AERODYNAMIC ANALYSIS OF SUB-ORBITAL RE-ENTRY VEHICLE (저궤도 재진입 비행체의 공력해석)

  • Kim, C.W.;Lee, Y.G.;Lee, D.S.
    • Journal of computational fluids engineering
    • /
    • v.13 no.2
    • /
    • pp.1-7
    • /
    • 2008
  • For Aerodynamic analysis of vehicle at altitude, 100km, the validity of governing equations based on continuum model, was reviewed. Also, as the preliminary study for the sub-orbital space plane development, a candidate geometry was suggested and computational fluid dynamic(CFD) analysis was performed for various angles of attack in subsonic and supersonic flow regimes to analyze the aerodynamic characteristics and performance. The inviscid flow analyses showed that the stall starts at angle of attack above $20^{\circ}$, the maximum drag is generated at angle of attack, $87^{\circ}$ and the maximum lift to drag ratio is about 8 in subsonic flow. In supersonic, the stall angle is about $40^{\circ}$ and the maximum drag is generated at angle of attack, $90^{\circ}$. Also, mach number distribution of re-entry vehicle was computed versus altitudes.

Requirement Analysis of Propulsion System for Active Anti-Ship Missile Decoy (능동형 대함 유도탄 기만기의 추진 시스템 요구 조건 분석)

  • Moon, Yongjun;Kwon, Sejin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.4
    • /
    • pp.1-9
    • /
    • 2013
  • An active anti-ship missile decoy system was designed conceptually to analyze propulsion system requirements and feasibility to use a liquid bi-propellant rocket engine. Overall mass, size, and shape were assumed referring to specifications of Nulka which was developed by US and Australia in 1990s. The propulsion system was assumed to be a 1,000 N-class $H_2O_2$/kerosene rocket engine with a pressurized feed system. A three-degree-of-freedom optimal trajectory was calculated based on the assumptions, and mass budget was designed from the calculation results. It was found that the requirements for the propulsion system is that it shall be operated more than 100 sec; it shall be re-ignitable; it shall have a throttle capability of a range from 35% to 100% when the maximum thrust at sea level is 1,000 N.

Comparative Study of Dissolution Properties of Immediate-release and Controlled-release Type Vitamin C Tablets (속방형 및 용출조절형 비타민 C 정제의 용출 특성 비교 분석)

  • Yang, Hyo-Jin;Ryu, Na-Hee;Yang, Joo-Hong;Hong, Sun-Ho;Lee, Yeonkyung;Cho, Yang-Hee
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.2
    • /
    • pp.114-120
    • /
    • 2022
  • In this study, a comparative dissolution experiment was conducted between an immediate-release and a controlled-release vitamin C tablet applied with a technology to control the dissolution of vitamin C to maintain the vitamin C level in the human body. In order to confirm the dissolution rate (%) of vitamin C tablets, HPLC determination was conducted based on the dissolution test methods in the 'Korean Pharmacopoeia (No. 2020-88),' 'Guidelines on Specifications of Dissolution Tests for Oral dosage Forms,' and 'Standard and Specifications for Health Functional Foods (No. 2020-63)' from Ministry of Food and Drug Safety (MFDS). In addition, the dissolution pattern between the immediate-release tablet and the controlled-release tablet was comparatively analyzed. The analysis result confirmed that the immediate-release vitamin C tablet was 100% dissolved after 45 minutes, while the controlled-release vitamin C tablet was 100% dissolved after 480 minutes (8 hours). Furthermore, the dissolution rate (%) at 60 minutes was slower than that of the immediate-release vitamin C tablet. Based on these results, this study confirmed that the dissolution rate (%) test and development of controlled-release tablets containing vitamin C as the main component a re possible.

Thickness Control of Electroplating Layer for Copper Pillar Tin Bump (구리기둥범프 용 전해도금 층 제어)

  • Moon, Dae-Ho;Hong, Sang-Jeen;Park, Jong-Dae;Hwang, Jae-Ryong;Soh, Dea-Wha
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.903-906
    • /
    • 2011
  • The electroplating and electro-less plating methods have been applied for the high density chip interconnect of the Copper Pillar Tin Bump (CPTB) preparation. The CPTB was prepared, which had been electroplated about $100{\mu}m$ pitch of copper layer firstly, and then the Tin layer was deposited on the copper pillar surface to protect the oxidation of it. It was also very important to get uniform thickness of electroplated copper layer, though it was difficult and sensitive. In order to control the thickness distribution, it was examined that the current separating disk of Insulating Gate with a hole in the center was installed between electrodes. The current flows through the center hole of the Insulating Gate in the cylindrical electroplating bath and the other parts were blocked to protect current flowing. The main current flowed through the center hole of the Insulating Gate directly to the opposite electrode of wafer disk. As the results, it was verified that the copper layer was thick in the center part of wafer disk with distribution of thinner to the outer part toward edge.

  • PDF

CaNb2O6:RE3+(RE=Eu, Sm) 적주황색 형광체의 합성과 발광 특성

  • Jeong, Un-Hwan;Jo, Sin-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.165-165
    • /
    • 2013
  • 희토류 발광 물질은 4f 껍질에 위치하는 전자의 독특한 특성 때문에 발광 소자와 디스플레이에 그 응용성을 확장하고 있다. 본 연구에서는 고효율의 적색과 주황색 형광체를 합성하기 위하여 모체 격자 CaNb2O6에 희토류 이온인 유로퓸과 사마륨을 치환 고용하여 최적의 합성 조건을 조사하였다. Ca1-1.5xNb2O6:REx3+ (RE=Eu, Sm) 형광체 분말 시료는 고상반응법을 사용하여 활성제 이온인 Eu3+와 Sm3+의 농도비를 0, 0.01, 0.05, 0.10, 0.15, 0.20 mol 로 변화시키면서 합성하였다. 초기 물질 CaO, Nb2O5, Eu2O3와 Sm2O3을 화학 적량으로 측정하고, 400 rpm의 속도로 24시간 밀링 작업을 수행한 후에, 건조기 $60^{\circ}C$에서 28시간 건조하고, 시료를 막자 사발에서 갈아 세라믹 도가니에 담아 튜브형 전기로에서 분당 $5^{\circ}C$의 비율로 승온시켜 $500^{\circ}C$에서 5시간 동안 하소와 $1,100^{\circ}C$에서 6시간 소결하여 합성하였다. Eu3+가 도핑된 경우에, 발광 스펙트럼은 Eu3+ 이온의 농도비에 관계없이 강한 적색 발광 스펙트럼이 616 nm에서 관측되었다. 이외에도, 596 nm와 708 nm에서 상대적으로 발광 세기가 약한 주황색 발광과 적색 발광 신호가 검출되었으며, 541 nm에서는 매우 약한 녹색스펙트럼이 관측되었다. Eu3+ 이온의 농도비에 0.01 mol에서 0.15 mol로 증가함에 따라 주발광 신호의 세기는 점점 증가하였으며, 0.15 mol에서 최대 발광 세기를 나타내었다. Eu3+ 이온의 농도비가 0.20 mol 로 더욱 증가함에 따라 주 피크의 세기는 농도 소강 현상에 의하여 현저히 감소함을 보였다. 한편, 주된 흡광 스펙트럼은 279 nm에서 나타났는데, 이것은 전하전달밴드 신호이다. Sm3+가 도핑된 형광체 분말의 발광 스펙트럼은 모든 시료의 경우에 613 nm에서 강한 적주황색 발광 스펙트럼이 관측되었고, 상대적으로 세기가 약한 570 nm와 660 nm에 피크를 갖는 황색과 적색 발광 스펙트럼이 발생하였다. 흡광과 발광 스펙트럼의 최대 세기는 0.05 mol에서 나타났으며, Sm3+ 이온의 농도비가 더욱 증가함에 따라 흡광과 발광 세기는 급격하게 감소하였다.

  • PDF

A Study on Flow Coefficient and Flow Characteristics for Butterfly Valve by Numerical Analysis (수치해석에 의한 버터플라이 밸브의 유량계수 및 유동특성에 관한 연구)

  • Kwak, Kyung-Min;Cho, Ji-Sung;Kim, Jin-Dae;Lee, Jung-Hyung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.4
    • /
    • pp.62-66
    • /
    • 2012
  • The objective of this study is to simulate flow coefficient and flow characteristics such as velocity and pressure distribution for butterfly valve. Butterfly valves used in this study are 65A, 80A and 100A, in size, and of which the opening angle is varied. The flow coefficient, Kv, increases as the disc opening and valve size are increase. When using flow coefficient meanwhile specific curve of flow rate is also determined. The flow velocity between disc and seat increase as the disc opening decrease. The re-circulating zone is also observed in downstream behind disc.

A Comparative Study between Steady and Unsteady Solutions of NACA0012 Airfoil flow (NACA0012 에어포일 주위 유동의 정상해와 비정상해 비교 연구)

  • Chu, Yeon-Bok;Jang, Gyeong-Sik
    • Proceeding of EDISON Challenge
    • /
    • 2012.04a
    • /
    • pp.121-124
    • /
    • 2012
  • 비정상 유동 해석을 수행하는데 있어서 비정상 Navier-Stokes 방정식을 적용한 결과와 정상 N-S 지배 방정식을 적용한 결과의 차이를 비교하려한다. 적용하고자 하는 비정상 유동은 대칭형 에어포일 NACA0012 에어포일 주위 유동으로 정하였으며, 이 때 에어포일 시위(chord) 길이와 자유류(free stream) 속도 기준으로 Re=100,000에 해당한다. 계산결과 비정상 지배 방정식을 적용한 경우 비정상 유동박리(flow separation)를 모사 할 수 있었으며, 평균 양력계수($C_L$)와 항력계수($C_D$)는 실험치와 비교적 잘 일치하였다. 하지만 정상 N-S 방정식을 적용했을 경우 비정상 유동을 모사하기 어려웠으며 평균양력, 항력계수도 실험치와 차이를 보였다. 이러한 결과는 비정상 유동 해석시 시간에 따라 변화하는 유동의 특성을 고려해 비정상 N-S 지배 방정식을 적용해야한다는 사실을 보이고 있다.

  • PDF

The Surgical Treatment of Type V Acute Acromioclavicular Joint Dislocation Using Suture Anchor and Kirschner Wire (봉합 나사못과 Kirschner 강선을 이용한 제 5형 급성 견봉 쇄골 관절 탈구의 수술적 치료)

  • Jung, Gu-Hee;Cho, Chyul-Hyun;Jang, Su-Jin;Jang, Jae-Ho;Kim, Jae-Do
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.217-222
    • /
    • 2010
  • Purpose: We wanted to evaluate the clinical outcomes after operative treatment using two suture anchors and Kirschner wire for treating acute Rockwood type V acromioclavicular joint dislocation Materials and Methods: Between May 2006 and May 2009, 10 patients underwent surgical treatment for acute Rockwood type V acromioclavicular joint dislocation using two suture anchors and Kirschner wire and they were followed for a mean of 12.0 (range: 7-31) months. We analyzed the functional results by the Korean shoulder score, the Constant-Murley score and the reduction state of the acromioclavicular joint at the last follow-up. Results: All the cases achieved a satisfactory outcome. The mean Korean shoulder score was 89.9 (range: 81-100) points and the mean Constant-Murley score was 87.8 (range: 82-93) points. According to the radiologic findings, 8 patients achieved anatomical reduction of the acromioclavicular joint: there was a slight loss of reduction in one patient and a partial loss of reduction in one patient. None of the patients had deep infection or re-dislocation. Conclusion: The operative treatment using two suture anchors and Kirschner wire may be used for acute Rockwood type V acromioclavicular joint dislocation, and it has an advantage in that it can prevent chondral injury of the joint.