• Title/Summary/Keyword: 한계검사

Search Result 574, Processing Time 0.025 seconds

A Study on Useful Application of Stitching Method for Full-Length Examination of the Femur (대퇴골의 전장검사 시 stitching method의 적용에 관한 유용성 연구)

  • Noh, Ji-Sook;Jung, Ji-Hoon;Kim, Sung-Kil;Jung, Myung-Jin
    • Journal of radiological science and technology
    • /
    • v.34 no.2
    • /
    • pp.97-103
    • /
    • 2011
  • The Full-length examination of the femur sometimes does not show all of the femur because of the limited width in collimator and size of detectors although it is located in the diagonal direction. Aim of this study is to identify usefulness of the method of combining images which obtained from two radiographic images containing the femoral head and condyle respectively. Our group interviewed 30 radiological technologists who used both palliative DR method and SM method in their examinations of the femur of patients who were carried to the emergency rooms in Gwang-ju city from August 2007 to November 2009. We evaluated twenty images according to the contraction of femoral neck, turning of knee joints and inclusion of the femur. The examination were performed by two radiologists and six radiological technologists who have more than ten years of career. The results are as follows: SM method was graded with higher score for examination time, number of examiners, emaciation, retake and patients' discomfort (p< 0.001) while the. SM method was scored higher than the palliative DR method in the palliative DR method for examination of long bone.

Building an Analytical Platform of Big Data for Quality Inspection in the Dairy Industry: A Machine Learning Approach (유제품 산업의 품질검사를 위한 빅데이터 플랫폼 개발: 머신러닝 접근법)

  • Hwang, Hyunseok;Lee, Sangil;Kim, Sunghyun;Lee, Sangwon
    • Journal of Intelligence and Information Systems
    • /
    • v.24 no.1
    • /
    • pp.125-140
    • /
    • 2018
  • As one of the processes in the manufacturing industry, quality inspection inspects the intermediate products or final products to separate the good-quality goods that meet the quality management standard and the defective goods that do not. The manual inspection of quality in a mass production system may result in low consistency and efficiency. Therefore, the quality inspection of mass-produced products involves automatic checking and classifying by the machines in many processes. Although there are many preceding studies on improving or optimizing the process using the data generated in the production process, there have been many constraints with regard to actual implementation due to the technical limitations of processing a large volume of data in real time. The recent research studies on big data have improved the data processing technology and enabled collecting, processing, and analyzing process data in real time. This paper aims to propose the process and details of applying big data for quality inspection and examine the applicability of the proposed method to the dairy industry. We review the previous studies and propose a big data analysis procedure that is applicable to the manufacturing sector. To assess the feasibility of the proposed method, we applied two methods to one of the quality inspection processes in the dairy industry: convolutional neural network and random forest. We collected, processed, and analyzed the images of caps and straws in real time, and then determined whether the products were defective or not. The result confirmed that there was a drastic increase in classification accuracy compared to the quality inspection performed in the past.

Development of Automatic Inspection System for ALC Block Using Distortion Correction Technique (왜곡 보정 기법을 이용한 ALC 블럭의 자동 검사 시스템 개발)

  • Han, Kwang-Hee;Huh, Kyung-Moo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.1
    • /
    • pp.1-6
    • /
    • 2010
  • The lens distortion in the machine vision system is inevitable phenomenon. Distortion is getting worse, due to the selection of lens in the trend of reducing prices and size of the system. In this trend, the distortion correction becomes more important. But, the traditional correction methods has problems, such as complexity and requiring more operations. Effective distorted digital image correction is the precondition of target detection and recognition based on vision inspection. To overcome the disadvantage of traditional distortion correction algorithms, such as complex modeling, massive computation and marginal information loss, an image distortion correction algorithm based on photogrammetry method is proposed in this paper. In our method, we use the lattice image as the measurement target. Through the experimental results, we could find that we can reduce the processing time by 4ms. And also the inspection failure rate of our method was reduced by 2.3% than human-eyes inspection method.

The Usefulness of Fluorescein Angiography and Alternative Tests for Assessment of Fundus Hemorrhage (안저 출혈 시 형광안저혈관조영술 및 대체 검사의 유용성)

  • Yeon, Je-Jin;Koo, Bon-Kyeong;Park, Sang-Ku
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.3
    • /
    • pp.266-276
    • /
    • 2021
  • Fundus hemorrhage refers to abnormalities in the retinal tissue and blood vessels. Therefore, when a hemorrhagic change in the fundus occurs, the ophthalmologist orders various ophthalmic tests to evaluate the degree of hemorrhage and determine the progress of the lesion before, during, and after treatment to accordingly establish a treatment plan. Currently, the most useful and universal fundus examination includes optical coherence tomography (OCT), fundus photography (FP), and fluorescein angiography (FAG). Existing fluorescein angiography test methods for establishing a treatment plan for severe fundus bleeding have limitations. The authors propose that peripheral pupil and the 5-quadrant method should be performed using ultra-wide-angle fluorescence fundus angiography (UWFFA). Using this method, it is possible to quickly determine the area to be described, avoid the radius of bleeding as much as possible, and provide the ophthalmologist with a range of damaged tissue and abnormal blood vessels. Nevertheless, there are cases in which ophthalmologists judge that fundus bleeding is so severe that ultra-wide-angle fluorescence fundus angiography is meaningless. In such cases, ophthalmic ultrasound and electroretinogram may be used in that order as alternative methods of examination. Therefore, some clinical situations require the use of ophthalmic ultrasound and electroretinogram and should be performed accurately.

A Scope of Work of Radiological Technologists for Ultrasound Examinations (초음파검사에 대한 방사선사 업무범위의 법적 고찰)

  • Lim, Chang Seon;Jin, Gye Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.481-490
    • /
    • 2021
  • There is no qualification system for sonographers in Korea. But the MEDICAL SERVICE TECHNOLOGISTS, ETC. ACT stipulates that radiological technologists can handle ultrasound equipment. However, there is controversy about the scope of the work allowed for radiological technologists to perform ultrasound examinations. Accordingly, the authoritative interpretation of the Ministry of Health and Welfare of Korea, the adjudication of administrative judgment, and the judgment of the courts were analyzed. As a result, the authoritative interpretation expresses that when a radiological technologist performs an ultrasound examination, a diagnosis and specific guidance should be made in real time while the doctor simultaneously watches the radiological technologist's images. In the adjudication of administrative judgment, it was decided that the handling of ultrasound-related equipment was the work of the radiological technologist. The court ruled that it was illegal for a radiological technologist to make a medical judgment on ultrasound examination. In the United States, Canada, etc., the sonographer independently conducts ultrasound examination according to the doctor's prescription, prepares a summary of what they saw and this is passed on to the doctor. Therefore, in Korea, there is a need for institutional improvement so that radiological technologists can perform ultrasound examinations according to doctors' prescriptions without real-time guidance.

The Role of Inhaled Corticosteroid in the Management of Chronic Cough (만성 기침에서 스테로이드 흡입제의 역할)

  • Lee, Kyung-Hun;Jang, Seung Hun;Lee, Jung-Hwa;Eom, Kwang-Seok;Bahn, Joon-Woo;Kim, Dong-Gyu;Shin, Tae Rim;Park, Sang Myon;Lee, Myung-Gu;Kim, Chul-Hong;Hyun, In-Gyu;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.2
    • /
    • pp.221-227
    • /
    • 2006
  • Background : Cough may be a consequence of bronchial hyperresponsiveness or inflammation. Empirical treatment is important in this context because it difficult to verify the obvious cause of cough using laboratory tests, Corticosteroid has a nonspecific anti-inflammatory effect, and can be used for cough management. However, its response rate has not yet been fully elucidated. This study investigated the short- term effects of inhaled corticosteroid on chronic cough Methods : Patients with chronic cough with a normal chest radiograph and a pulmonary function test were enrolled. Cases with a prior respiratory infection within 8 weeks, a history of bronchial asthma, objective wheezing on examination, subjective symptoms of gastroesophageal reflux or taking an ACE inhibitor were excluded. On the first visit, a methacholine bronchial provocation test, spontaneous sputum eosinophil count performed twice and a paranasal sinus radiograph were checked, and the patients were treated with budesonide turbuhaler $800{\mu}g/day$ for ten days. The primary outcome measure was a decrease in the cough score after treatment. Results : Sixty nine chronic coughers were finally analyzed. The final diagnoses by the routine tests were as follows: bronchial asthma 13.0%, eosinophilic bronchitis 18.8%, paranasal sinusitis 23.2% and non-diagnostic cases 53.6%. The following responses to the inhaled corticosteroid were observed: definite responders, 76.8%, possible responders, 2.9% and non-responders, 20.3%. The response rate was not affected by the final diagnosis even in the non-diagnostic cases. There were minimal adverse drug related effects during the empirical treatment. Conclusion : Routine objective tests such as methacholine provocation, sputum eosinophil count and simple radiographs were notare not suitable for diagnosing chronic cough Therefore, empirical treatment is important. Short term inhaled corticosteroid is effective and can guide a further treatment plan for chronic cough.

An Estimation of Mean Background Concentrations of Greenhouse Gases Observed on Ulleungdo (울릉도 온실기체 관측자료를 이용한 배경대기 평균농도 산정)

  • Lim, Yun-Kyu;Moon, Yun-Seob;Kim, Jin-Seog;Song, Sang-Keun;Hong, Ji-Hyung
    • Journal of the Korean earth science society
    • /
    • v.33 no.1
    • /
    • pp.32-38
    • /
    • 2012
  • Mean background concentrations of greenhouse gases such as $CO_2$ and $CH_4$ were estimated on Ulleungdo using PICARRO Cavity Ring-Down Spectroscopy (CRDS) analyzer. To improve the accuracy of $CO_2$ and $CH_4$ concentrations, a standardized QA${\cdot}$QC (Quality Assurance Quality Control) procedure was employed with three steps: 1) the inspection procedure of physical limitation (e.g. the exclusion of data corresponding to the number of data of ${\leq}$50%) for hourly mean values, 2) a stage inspection (e.g. the use of data corresponding to ${\geq}15$ observations per day) for daily mean values, and 3) a fast fourier transform (FFT) analysis using curve-fitting methods for the investigation of climatic characteristics. The monthly mean concentrations of $CO_2$ and $CH_4$ derived from three-step QA${\cdot}$QC procedure were then compared with those observed at Anmyundo (Korea) and Ryori (Japan). Overall, the error of mean $CO_2$ and $CH_4$ concentrations estimated in this study distinctly decreased. However, in comparison with their concentrations monitored at Ryori, the $CO_2$ concentration at estimated at Ulleungdo is soemwhat lower than that of Anmyundo due to the missing data, which is statistically significant. On the other hand, the former has a statistically significant higher value of $CH_4$ that of the latter.

Energy Based Source Location by Using Acoustic Emission for Damage Detection in Steel and Composite CNG Tank (금속 및 복합재 CNG 탱크에서의 손상 검출을 위한 음향방출 에너지 기반 위치표정 기술)

  • Kim, Il-Sik;Han, Byeong-Hee;Park, Choon-Su;Yoon, Dong-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.5
    • /
    • pp.332-340
    • /
    • 2015
  • Acoustic emission (AE) is an effective nondestructive test that uses transient elastic wave generated by the rapid release of energy within a material to detect any further growth or expansion of existing defects. Over the past decades, because of environmental issues, the use of compressed natural gas (CNG) as an alternative fuel for vehicles is increasing because of environmental issues. For this reason, the importance and necessity of detecting defects on a CNG fuel tank has also come to the fore. The conventional AE method used for source location is highly affected by the wave speed on the structure, and this creates problems in inspecting a composite CNG fuel tank. Because the speed and dispersion characteristics of the wave are different according to direction of structure and laminated layers. In this study, both the conventional AE method and the energy based contour map method were used for source location. This new method based on pre-acquired D/B was used for overcoming the limitation of damage localization in a composite CNG fuel tank specimen which consists of a steel liner cylinder overwrapped by GFRP. From the experimental results, it is observed that the damage localization is determined with a small error at all tested points by using the energy based contour map method, while there were a number of mis-locations or large errors at many tested points by using the conventional AE method. Therefore, the energy based contour map method used in this work is more suitable technology for inspecting composite structures.

Comparison of Methods for Measuring Histamine by ELISA and HPLC-MS Assay In Vitro (In Vitro에서 히스타민 측정 시 ELISA법과 HPLC-MS 분석법의 비교)

  • Lee, In Hee;Kim, Yoo Hyun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.47 no.4
    • /
    • pp.306-312
    • /
    • 2015
  • The measurement of histamine is to determine the degree of allergy because the allergic reaction can lead to the release of histamine. In general, the antigen-antibody reaction was quantified by measuring absorbance using a microplate reader. In this study, we compare the method using a general antigen-antibody reaction and the method using a high performance liquid chromatography mass spectrometer (HPLC-MS) of chemical analysis in the measurement of histamine secretion. The cell line used was RBL-2H3, an allergic reaction was induced by stimulation with C48/80 (compound 48/80). Allergy-induced cells degranulation rate was confirmed by measurement of ${\beta}$-hexosaminidase and cytotoxicity was performed for the validity of the experiment. The quantitative determination of histamine showed a significant difference, since the quantitative limit of the measurement by the antigen-antibody reaction was 10.257 ppm while the quantitative limit of the measurement by HPLC-MS was 0.020 ppm. Measurement of histamine in allergic activity and anti-allergy tests showed that the HPLC-MS analysis rather than the analysis of the antigen-antibody reaction is a more precise and accurate test.

Ultrasonic C-scan Technique for Nondestructive Evaluation of Spot Weld Quality (Spot용접 접합면의 초음파 비파괴평가 기법 제 1보 C-scan 기법을 중심으로)

  • Park, Ik-Gun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.2
    • /
    • pp.112-121
    • /
    • 1994
  • This paper discusses the feasibility of ultrasonic C-scan technique for nondestructive evaluation of spot weld quality. Ultrasonic evaluation for spot weld quality was performed by immersion method with the mechanical and the electronic scanning of point-focussed ultrasonic beam(25 MHz). For the sake of the approach to the quantitative measurement of nugget diameter and the discrimination of the corona bond from nugget, preliminary infinitesimal gap experiment by newton ring is tried in order to set up the optimum ultrasonic test condition. Ultrasonic image data obtained were confirmed and compared by optical microscope and SAM(Scanning Acoustic Microscope) observation of the spot-weld cross section. The results show that the nugget diameter can be measured with the accuracy of 1.0mm, and voids included in nugget can be detected to $10{\mu}m$ extent with simplicity and accuracy. Finally, it was found that it is necessary to make a profound study of definite discrimination of corona bond from nugget and the approach of quantitative evaluation of nugget diameter by utilizing the various image processing techniques.

  • PDF