• Title/Summary/Keyword: 학교 건축

Search Result 739, Processing Time 0.023 seconds

A Study on the PM10 and CO2 Concentrations at Public Places (일부 실내공간에서 PM10과 CO2의 농도 특성에 관한 연구)

  • Jung, Joon-sig;Park, Duckshin;Kim, Jong bum;Song, Hyea-suk;Park, Hyung-kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4335-4347
    • /
    • 2015
  • The objective of this study was to investigate $PM_{10}$ and $CO_2$ concentrations in the classrooms of 286 elementary schools in Suwon, Ansan, and Hwaseong in the province of Gyeonggi between August 2008 and December 2012. By gaining an understanding of the environmental factors that influence these concentrations, this study also aimed to establish a management plan for indoor air quality in schools, which substantially affects the health of elementary students. When the schools were classified by region, no statistically significant difference in $PM_{10}$ concentration was observed. However, $PM_{10}$ concentration was relatively high in industrial areas and low in rural areas. No difference in $CO_2$ concentration was observed among the surveyed cities. Analysis of annual $PM_{10}$ concentration showed that the highest values for Suwon and Hwaseong occurred in 2008 and 2009, respectively (p<0.01). In the case of Ansan, the highest concentration occurred during 2009, but the difference was not significant compared to the other years. Analysis of the annual $CO_2$ concentration of each city shows no significant difference among the cities (p-value=0.366,0.730,0.210). According to a time series analysis of $PM_{10}$ and $CO_2$ by season, from autumn 2008 to winter 2012, $PM_{10}$ concentration was high during 2009, then it gradually decreased until 2012, and started to increase again. While no difference in annual $CO_2$ concentration was observed, the concentration had a tendency to be higher in spring and winter than in summer. By analyzing the relationship between $PM_{10}$ and $CO_2$ and the environmental factors (years of construction, average students of classroom, temperature, and humidity), it showed a significant negative correlation was found between $CO_2$ and the environmental temperature and humidity, at -0.329 and -0.188, respectively (p<0.01).

A study of Exhibition Planning based on the Installation Art - Focused on an Environmental Poster Exhibition - (설치미술의 배경과 전시디자인에 관한연구 - 국제교류 환경포스터 디자인전을 중심으로 -)

  • Shin, Seong-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.173-180
    • /
    • 2009
  • Increased appetite for art and design due to improving the economic standard of living and industrial community recognized the value of art in the profitable aspect currently demands various exhibitions in various environments. These social needs and changes in corporate culture to meet the rapidly expanding opportunities for artistic exhibitions, and this modern exhibition outside of the conventional gallery requires more for designers to work with various exhibition spaces, and the opportunities are increasing further. Various types of exhibition space in the exhibition planning an unspecified environment best suited to each exhibit space has been designed to require. This comprehensive study of an environmental poster exhibition held in the Seoul Institute of the Arts, MA-block lobby during 2009.06.10-06.19 was a part of the international exchange projects between Seoul Institute of the Arts and California State University, Northridge. Planning and designing throughout the exhibition in an unspecified space for exhibition requires more creativity and flexible approaches than in the general exhibition gallery.

A Proposal for Optimizing Unit Modular System Process to Improve Efficiency in Off-site Manufacture, Transportation and On-site Installation (유닛 모듈러 공법의 효율성 확보를 위한 공장제작, 운반, 현장설치의 최적 공정 제안)

  • Lee, Kwang-Bok;Kim, Kyung-Rai;Shin, Dong-Woo;Cha, Hee-Sung
    • Korean Journal of Construction Engineering and Management
    • /
    • v.12 no.6
    • /
    • pp.14-21
    • /
    • 2011
  • A unit modular system is a construction method which installs on site by manufacturing 50%~90% of the whole process in the factory. This method can minimize the process in the site and maximize the operation, which will reduce the duration and improve the overall quality. The recent paradigm of construction is to be sustainable building. Modular system can be regarded as a sustainable building construction method because it can reduce the amount of construction waste by recycling partial or whole part of overdue building be torn down. A unit modular system is the answer to cope with the increasing market of small size housings. A unit modular system is the most appropriate option at this point. This research proposes the standard operation and construction process of modular system, which enable to optimal system. A case study of reconstructing small-size housing was introduced to support this proposal. Finished unit modular is the reasonable way. However, 80% of complication rate of the modular is the most rational when a defect occurrence during delivery is considered.

Seismic Performance Evaluation of Masonry Walls Retrofitted with Semi-buried Lattice Reinforcement (조적식 구조물의 부분 매입식 격자철근 보강기법의 내진 성능 평가)

  • Kim, Sang Hyo;Choi, Moon Seock;Park, Se Jun;Ahn, Jin Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.3
    • /
    • pp.88-98
    • /
    • 2011
  • Masonry structure is a style of building which has been widely applied as residential facilities of low and middle stories, commercial and public facilities etc. But it is possible to destroy by loss of adhesive strength or sliding when lateral forces, such as earthquake, occurs. This study proposes a seismic retrofit method for masonry structure and its seismic performance is demonstrated by shaking table test. Two specimens per each shaking direction were made, having out-of-plane(weak axis) and in-plane(strong axis) direction. External load of 1 ton was also applied for each specimen during the test, to model the behavior of reinforced masonry wall. As a result of shaking table tests, it is shown that the specimen applying the proposed seismic retrofit method showed acceptable behaviors in both of Korea building design criteria(0.14g) and USA seismic criteria suggested by IBC(0.4g). However, it was observed that stiffness of the specimen toward out-of-plane was rapidly decreasing when seismic excitations over 0.14g were loaded. In comparison of relative displacements, maximum relative displacement of specimens which were accelerated toward out-of-plane with 0.4g at once was 29~31% of maximum relative displacement when specimens were gradually accelerated from 0.08g to 0.4g, while the maximum relative displacement of specimens accelerated toward in-plane has similar value in both cases. Therefore, it is concluded that the wall accelerated toward out-of-plane is more affected by hair crack or possible fatigues caused by seismic excitation.

The Status of Damage and Monitoring of Subterranean Termite (Reticulitermes spp.) (Blattodea: Rhinotermitidae) for Wooden Cultural Heritage in Korea (국내 목조문화재에 대한 지중 흰개미 피해 및 모니터링 현황)

  • Im, Ik-Gyun;Cha, Hyun-Seok;Kang, Won-Chul;Lee, Sang-Bin;Han, Gyu-Seong
    • Journal of Conservation Science
    • /
    • v.37 no.3
    • /
    • pp.191-208
    • /
    • 2021
  • In this study, the status of damage by subterranean termites and their management according to the region and type of domestic wooden cultural properties were identified. This was based on the survey reports of agencies conducting regular nationwide and regional monitoring of subterranean termites. In addition, using geographical information system (GIS) based on the survey contents, a map was constructed of termite infestation and its progress on 2,805 wooden cultural properties that were surveyed nationwide. Based on the map produced, a total of 486 cases of termite infestation were confirmed in wooden cultural properties during 2018-2019, of which 143 cases (approximately 29.4%) were confirmed to be owing to the invasion of termites in the ground and infestation of wood materials. A web platform and an application using a mapping application program interface were created to increase accessibility to the investigated damage status data. The methods employed by each institution for investigating and monitoring the invasion of termites in the ground included the use of detection dogs, visual observation, installation of wood specimens made of pine, and microwave equipment. However, it was confirmed that monitoring and survey methods were not applied to determine the territorial range of the subterranean termite colonies. Accordingly, the use of dyeing and mark-release-recapture methods were deemed necessary to understand the current status, such as calculating the scope of the target wooden cultural property, when monitoring subterranean termite colonies.

A Study on the Evacuation Behavior of Students Due to Tsunami Occurrence in Coastal Areas: Focusing on the Great East Japan Earthquake (연안지역 지진해일 발생에 따른 학생들의 피난행동에 관한 연구 -동일본 대지진을 중심으로-)

  • Won-Jo Jung;Akihito Souda;Takashi Yokota;Tadasu Iida;Koji Itami;Myung-Kwon Lee
    • Journal of Navigation and Port Research
    • /
    • v.47 no.1
    • /
    • pp.18-24
    • /
    • 2023
  • After the Great East Japan Earthquake, many reports and books that compiled testimonies of adult victims were published. Thus, refugee situations are well known, but information on the refugee situations of Japanese students is not. This is because what actions the students took and how they sought refuge from an earthquake or tsunami have not been fully recognized. The purpose of this study was to examine and analyze students' refuge behavior in the Great East Japan Earthquake and to predict the refuge behavior of students affected by future disasters. The results of the study showed that students passively acquired information about earthquakes and tsunamis and that their refuge behavior was highly dependent on adults. Immediately after an earthquake, people tended to protect themselves and stay in place until the shaking stopped. However, they tended to move to another place after the shaking occurred frequently. Students living on ria coastlines were likely to move to high places to escape the threat of earthquakes and tsunamis, whereas students living in plain regions were likely to move vertically to tall buildings, such as schools. As for the mode of movement to refugee shelters, the students arrived at the final refugee shelters in one move, and it is assumed that the refugee shelters should be decided in advance and the students should move there.

Static Experiment of Reinforced Concrete Frame Retrofitted with Steel Damper System (강재댐퍼시스템으로 내진보강된 철근콘크리트 골조의 정적가력실험)

  • Baek, Eun Rim;Lee, Sang Ho;Oh, Sang Hoon;Kim, Jae Bong
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.90-90
    • /
    • 2011
  • 최근 전 세계적으로 지진의 발생 빈도가 증가하며 그 규모도 점차 커지는 경향을 보이고 있다. 대형지진의 발생 시 저층 구조물의 붕괴로 인한 인명 및 사회, 경제적 피해가 두드러짐에 따라 기존 저층 구조물의 내진보강기법에 관한 연구가 활발히 진행 중인 추세이다. 우리나라의 경우 강도증가형 내진보강공법이 주를 이루고 있어 다양한 내진보강기법의 개발 및 적용이 필요한 실정이다. 따라서 본 연구에서는 지진입력하중 저감형 내진보강기법으로서 강재댐퍼시스템을 제안하여 구조적 성능을 파악하고, 이를 적용한 보강 실험체와 비보강 실험체를 제작하여 정적가력실험을 통하여 그 성능을 비교하였다. 제안된 강재댐퍼시스템은 입력에너지를 소산시키는 내부의 슬릿형 댐퍼와 이를 지지하는 기둥 및 외부 프레임으로 구성되며, 내부 댐퍼는 먼저 항복하여 에너지를 소산시키기 위하여 지지기둥 및 프레임에 사용된 강재보다 강성 및 강도가 적게 계획되었다. 강재댐퍼의 성능실험 결과, 비교적 안정적 거동을 하며, 강성과 강도 및 에너지 흡수능력이 우수하게 나타났다. 보강 및 비보강 실험체의 골조는 기존 학교 건축물의 표준도면을 기준으로 하여 골조의 일부를 대상으로 60% 축소율을 적용하여 계획하였으며, 보강 실험체는 미리 제작된 강재댐퍼시스템을 골조 내에 설치하여 에폭시 주입법으로 부착시공 하였다. 보강 및 비보강 골조 실험체의 정적가력 실험결과 비보강 실험체는 기둥의 휨 항복 후 변형의 증가에 따라 휨 및 전단 균열이 증가하면서 최종적으로 기둥이 전단파괴 되었으며, 보강 실험체는 비보강 실험체에 비하여 기둥 및 보의 균열이 적고, 골조에 골고루 분포되어 파괴 규모가 감소하였다. 최대 강도면에서 보강 실험체는 비보강 실험체에 비하여 약 3.4배 우수하였으며, 초기강성은 약 7배 가량 유리한 것으로 평가되어 제안된 강재댐퍼시스템이 강도면에서 우수한 성능을 나타냄을 알 수 있었다. 또한 두 실험체의 기둥 주근 및 띠철근의 변형률을 비교한 결과, 비보강 실험체는 대부분의 철근이 항복하여 큰 변형을 일으킨 반면, 보강실험체에서는 철근의 항복현상이 나타나지 않았고 댐퍼가 항복을 하면서 큰 변형을 일으켰다. 이를 통해 지진하중 입력 시 댐퍼에서 입력 에너지를 흡수하여 큰 하중을 부담하며, 기존의 구조부재에는 입력 에너지가 낮아 손상이 보다 적게 발생함을 확인하였다.

  • PDF

A Study of Corporate Benchmarking Process with Focus on the Characteristics of Korean Construction Industry (국내 건설산업 특성을 고려한 기업의 벤치마킹 프로세스)

  • Lee, Dong-Hoon;Kim, Sun-Kuk;Choi, Jea-Hwi;Lee, Won-Suk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.11 no.6
    • /
    • pp.24-34
    • /
    • 2010
  • Benchmarking is an effective tool supporting improvement of corporate competitiveness and development of management strategy, however, its effectiveness may be compromised if its target and approach are not appropriate. Notably, the construction industry of Korea is unique in that it has a number of competitors sharing the same category and is significantly exposed to changes in external environment in terms of legal, regulatory and policy frameworks. Such characteristics make target corporate category rather than single company more suitable as benchmarking target and necessitate analysis of external environment. This study intends to analyze the characteristics of construction industry in Korea and conditions of domestic companies in order to propose a benchmarking process for construction industry differentiated from conventional ones.학교 건축공학과, 산학협력기술연구원;경희대학교 대학원;경희대학교 대학원;

The Assessment of Survey on the Indoor Air Quality at Schools in Korea (국내 일부학교 건축물의 실내공기질 평가)

  • Sohn Jong-Ryeul;Roh Young-Man;Son Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.2 s.89
    • /
    • pp.140-148
    • /
    • 2006
  • Recently, indoor air quality (IAQ) in workplace, residential environments and schools has been concerned of people, scientists and related the public, and has recognized the health effects related to indoor air pollution. Therefore, this study was performed to investigate the characteristics of IAQ in 55 kindergartens, elementary school, middle schools, and high schools from June, 2004 to May, 2005 in Korea. We measured indoor air pollutants($PM_{10},\;CO_2$, HCHO, total bacteria colony(TBC), CO, radon, TVOCs, asbestos, and $O_3$), and physical factors(noise, temperature, relative humidity, and illumination) with necessary of management for IAQ in school. We classified into 5 kinds of the school by period since building completion, <1 year, 1-3 years, 3-5 years, and 5-10 years. The concentration of pollutants and the level of physical factors compared with standards and guidelines of IAQ on the Ministry of Environment, the Ministry of Health and Welfare, and the Ministry of Education and Human Resources Development. The major results obtained from this study were as follows. Temperature, relative humidity and illumination among the physical factors did not exceed the standards, but noise exceeded it. Asbestos and $O_3$ did not detect in surveyed classrooms. CO, TBC, TVOCs, and HCHO in kindergartens, TBC in elementary schools, TBC, TVOCs dnd HCHO in middle schools, and HCHO in high schools detected the standards. This study is conducted as a part of efforts to provide a foundational data for further relative researches on management of IAQ of school. Therefore, we suggest that country plan for management of IAQ in school should be established through long-term and continuous investigation for assessment on IAQ in school and health risk assessment for students.

A Study on the Present condition Investigation and Analysis of Educational Facilities Maintenance (교육시설 유지관리 현황조사 및 분석)

  • You, Young-Hun;Lee, Eun-Dong;Cho, Chang-Yeon;Kim, Jae-On;Son, Jae-Ho
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2006.11a
    • /
    • pp.361-366
    • /
    • 2006
  • As time goes by, educational facilities have become superannuated and damaged; therefore, performance and safety of buildings have been decreased. It causes the decrease of service quality and deterioration of educational environment. In order to protect facilities from serious damages and deterioration, a consistent maintenance and repair program is required. The educational facilities can keep the good educational environments and also make better environments through the program. This study is made by investigating and analyzing the maintenance data which was collected from fifty schools in Asan area, Chungchengnam-do in order to derive foundation data for the efficient educational environment maintenance program.

  • PDF