• Title/Summary/Keyword: 하행흉부대동맥

Search Result 59, Processing Time 0.018 seconds

Descending Aorta Index and Pulmonary Index in Infants Comparison between Atrioventricular Septal Defects, At ial Septal Defects and Ventricular Septal Defects (심방실 중격 결손증에서의 하행대동맥, 폐동맥 지수)

  • 안재호
    • Journal of Chest Surgery
    • /
    • v.26 no.8
    • /
    • pp.591-594
    • /
    • 1993
  • To clarify the apparent hypoplasia of the descending aorta in infants with atrioventricular septal defect[AVSD] patients, we reviewed the catheterization data and angiograms of 34 consecutive patients with AVSD less than 1 year of age who underwent repair at our institution since 1985. We compared them to 10 patients with Atrial Septal Defect[ASD] and 10 patients with Ventricular Septal Defect[VSD] who were matched for age, size and Qp/Qs. The Descending Aorta Index [DAI] of the AVSD group was not different from the VSD or ASD groups, [147.9$\pm$ 34.8 mm2/m2 versus 158.6$\pm$ 31.5 mm2/m2 and 153.2$\pm$ 43.1 mm2/m2].However, the Pulmonary Artery Index [PAI] of the AVSD group was significantly larger than the other groups [684.3$\pm$ 170.7 mm2/m2 versus 454.1$\pm$ 109.1 mm2/m2 and 534.9$\pm$ 148.4 mm2/m2][p<0.05], as was the ratio of PAI/DAI in the AVSD group [4.99$\pm$ 1.77 versus 2.89$\pm$ 0.81 and 3.6$\pm$ 0.92][p<0.05]. Despite similar Qp/Qs ratios, both the mean PA pressure and the Rp/Rs in the AVSD group was higher than the VSD and ASD groups: 43.1$\pm$ 15.6 mmHg versus 29$\pm$ 11.6 mmHg and 24$\pm$ 18.1 mmHg [p<0.05], and 0.27$\pm$ 0.22 versus 0.14$\pm$ 0.03 and 0.11$\pm$ 0.05 [p<0.05] respectively. The apparent hypoplasia of the descending aorta in infants with AVSD is an illusion created by the abnormally large pulmonary arteries, which are significantly larger than in patients with ASDs or VSDs.

  • PDF

Relation of Neoaortic Root Dilation and Aortic Insufficiency after Arterial Switch Operation (동맥전환술 후의 신생대동맥근부 확장과 대동맥판막폐쇄부전의 관계)

  • 박한기;김도균;홍유선;이종균;최재영;조범구;박영환
    • Journal of Chest Surgery
    • /
    • v.36 no.12
    • /
    • pp.921-927
    • /
    • 2003
  • Arterial switch operation (ASO) has been the most effective surgical option for transposition of the great arteries. But, the inappropriate dilation of the neoaortic root has been reported and its effect on neoaortic valve function and growth of aorta has not been well documented. Material and Method: Forty-eight patients who underwent cardiac catheterization during follow up after arterial switch operation were included in this study. Arterial switch operation was performed at a median age of 18 days (range 1∼211 days). Preoperative cardiac catheterization was performed in 26 patients and postoperative catheterization was performed in all patients at 15.8$\pm$9.6 months after ASO. Postoperative ratios of the diameters of neoaortic annulus, root and aortic anastomosis against the descending aorta were compared to the size of preoperative pulmonary annular, root and sinotubular junction. Preoperative and operative parameters were analyzed for the risk factors of neoaortic insufficiency. Result: There were two clinically significant neoaortic insufficiencies (grade$\geq$II/IV) during follow up, one of which required aortic valve replacement. Another patient required reoperation due to aortic stenosis on the anastomosis site. Post-operatively, neoaortic annulus/DA ratio increased from 1.33$\pm$0.28 to 1.52$\pm$.033 (p=0.01) and neoaortic root/DA ratio increased form 2.02$\pm$0.40 to 2.56$\pm$0.38 (p<0.0001). However, the aortic anastomosis/DA ratio showed no statistically significant difference (p=0.06). There was no statistically significant correlation between the occurrence of neoaortic insufficiency and neoaortic annulus/DA ratio and neoaortic root/DA ratio. Non-neonatal repair (age>30days) (p=0.02), preopeative native pulmonaic valve stenosis (p=0.01), and bisuspid pulmonic valve (p=0.03) were the risk factors for neoaortic insufficiency in univariate risk factor analysis. Conclusion: After ASO, aortic anastomosis site showed normal growth pattern proportional to the descending aorta, but neoaortic valve annulus and root were disproportionally dilated. Significant neoaortic valve insufficiency rarely developed after ASO and neoaortic annulus and root size do not correlate with the presence of postoperative neoarotic insufficiency. ASO after neonatal period, preoperative native pulmonary valve stenosis, and bicuspid native pulmonic valve are risk factors for the development of neoaortic insufficiency.

Anomalous Systemic Arterial Supply to the Lung without Sequestration A Cases Report (폐분획없는 폐동맥의 하행대동맥 기시이상 1례 보고)

  • 김요한
    • Journal of Chest Surgery
    • /
    • v.18 no.1
    • /
    • pp.104-110
    • /
    • 1985
  • The anomalous systemic arterial supply to the lung without sequestration is an uncommon congenital anomaly characterized by the presence of a part of lung tissue which supplied by an aberrant artery from the aorta or its branch and normal communication with the normal bronchial tree, and it was reported by Huber in 1777 first. It differs from bronchopulmonary sequestration in having normal bronchial communication from the remainder lung and normal lung histology. We experienced a case of anomalous systemic arterial supply to the lung without sequestration, which was confirmed preoperatively. The patient was 16 year old male and came to us with complaints of mild fever and profuse sputum with coughing. Chest film showed a ring-like soft tissue shadow in Rt. middle lung field. Aortogram revealed an aberrant artery originated from abdominal aorta at 12th thoracic vertebral level and supplying a part of Rt. lower lobe of lung. At. the time of operation, an aberrant systemic artery which originated from the abdominal aorta supplying the Rt. lower lobe was noted, and the bronchial communications were normal. After division and ligation of the aberrant artery, Rt. lower lobectomy was performed The postoperative courses were uneventful and the patient was discharged with good condition.

  • PDF

Experimental Study of Adjustable Pulmonary Artery Banding Device (가변성 폐동맥 협착기구의 실험적 연구)

  • 홍유선;박영환
    • Journal of Chest Surgery
    • /
    • v.30 no.8
    • /
    • pp.747-751
    • /
    • 1997
  • We developed a subcutaneously adjustable new pulmonary artery banding device which can be easily tightened or released in patients with unstable postoperative hemodynamics. The banding device consists of stainless spring which is enveloped with PTFE, nd polyvinyl catheter(5F). And the adjuster consists of another polyvinyl tube with forming cap. We mark transluscent polyvinyl tube 1mm each in length. 6 dogs weighing 15 to 25 kg underwent banding of descending thoracic aorta with the device. At postoperative 1 and 2 day, the device was effectively banded and released. Even 3 months later, we noted effective banding with some degree of vessel injury. The preliminary animal study suggests that this new device may be applicable in patient with excessive pulmonary blood flow.

  • PDF

Surgical Resection of a Posterior Mediastinal Tumor That Was Previously Treated with Aortic Stent-graft under the Misdiagnosis of Aortic Aneurysm -A case report- (대동맥류로 오인되어 스텐트 그라프트가 삽입되었던 후종격동 육종의 수술 치험 -1예 보고-)

  • Kim, Mi-Jung;Park, Kay-Hyun;Lim, Cheong;Chung, Eui-Suk;Lee, Hae-Young;Choi, Jin-Ho
    • Journal of Chest Surgery
    • /
    • v.43 no.5
    • /
    • pp.546-549
    • /
    • 2010
  • A 70-year-old man was transferred to our center due to severe epigastric and back pain with the impression of a ruptured thoracic aortic aneurysm. Six months previously, he had undergone insertion of stent graft into the descending thoracic aorta at another hospital. The findings of the computed tomographic scan suggested a rapidly growing malignant mediastinal tumor rather than a ruptured aneurysm. Exploratory thoracotomy confirmed the diagnosis and the tumor was resected along with the portion of the aorta contained in it. This exemplary case should raise the concern against overzealous application of endovascular aortic repair.

Clinical Analysis of the Operative Results of the Type A Aortic Dissection according to the Location of the Intimal Tear (급성 Type A 대동맥 박리에서 내막 파열의 위치에 따른 수술 성적의 분석)

  • Kim, Hyuck;Chung, Ki-Chun;Jee, Heng-Ok;Kang, Jung-Ho;Chung, Won-Sang;Lee, Chul-Bum;Chon, Soon-Ho;Kim, Young-Hak
    • Journal of Chest Surgery
    • /
    • v.37 no.6
    • /
    • pp.517-523
    • /
    • 2004
  • Background: The location of intimal tear can vary in type A acute aortic dissection. The aim of this study was to assess the operative result according to the intimal tear site. Material and Method: From January, 1995 to May, 2003, 18 patients underwent surgery for acute type A aortic dissection. The patients were classified according to the intimal tear site. In Group I (n=11), the intimal tear site was located within the ascending aorta, in Group II (n=7), the intimal tear site was located in the aortic arch, descending aorta, or intramural hematoma only. All clinical data were analyzed retrospectively. Result: In Group I, the operative time, cardiopulmonary bypass time, aorta cross clamp time and circulatory arrest time were 381.5$\pm$81.0 min, 223.5$\pm$42.5 min, 146.4$\pm$34.8 min and 36.5$\pm$17.4 min, respectively; and in group II, 461.7$\pm$54.0 min, 252.5$\pm$45.3 min, 162.5$\pm$45.3 min and 47.0$\pm$14.4 min respectively. All of those were greater in group II. The overall hospital mortality rate was 27.8% (5/18) and was significantly higher in Group II (57.1%)(p=0.003) compared to that in Group I (9.1%). The causes of death were hemorrhage (n=1) in group I and hemorrhage (n=2), multiple organ failure (n=1), and rupture of abdominal aorta (n=1) in group II. Conclusion: Surgical treatment of acute type A aortic dissection with intimal tear in the ascending aorta results in an acceptable mortality rate, but in patients with intimal tear in the aortic arch or descending aorta, the operative mortality still remains high when only ascending aorta replacement was performed. In these circumstances, in order to improve surgical results, efforts to include the intimal tear site in the operative procedure will be needed.

Pulmonary Arterial Growth Pattern after Shunt Operation in Patients of Pulmonary Atresia with Ventricular Septal Defect Associated with Juxtaductal Stenosis (Juxtaductal stenosis가 동반된 PA/VSD환자에서 체폐단락술 부위에 따른 폐동맥 크기의 변화)

  • 이교준;박영환;최재영;조범구
    • Journal of Chest Surgery
    • /
    • v.31 no.9
    • /
    • pp.861-866
    • /
    • 1998
  • Background: Pulmonary atresia (PA) with ventricular septal defect has various morphology of pulmonary arteries and pulmonary blood flow sources, so pulmonary arterial hypoplasia and arborization abnormality make this anomaly difficult to manage surgically. In cases associated with juxtaductal stenosis, we evaluated the change of the pulmonary arterial and juxtaductal stenotic site after shunt operations, and would like to find useful information in surgical planning and methodology of these patients. Material and Method: Among 59 cases diagnosed as PA with ventricular septal defect associated with juxtaductal stenosis, 29 cases who had cardiac catheterization before and after shunt operation were selected from July, 1991 to July, 1996. In 10 cases of right shunt operation(Group I) and 19 cases of left shunt operation (Group II), the diameters of the descending aorta, both pulmonary arteries, and the juxtaductal stenosis site were measured before and after the shunt operation. Result: In both Group I and II, the pre- and postoperative ratio of diameters of the ipsilateral pulmonary artery to the descending aorta was from 0.78${\pm}$0.31 units to 1.01${\pm}$0.26 units and from 0.67${\pm}$0.18 units to 0.84${\pm}$0.27 units respectively, showing a signigicant increase. The contralateral pulmonary artery index was increased from 0.92${\pm}$0.28 units to 1.05${\pm}$0.15 units and from 0.94${\pm}$0.27 units to 1.08${\pm}$0.37 units respectively, but could not be confirmed statistically. In both groups, the change of juxtaductal stenosis showed an aggravating tendency but of no statistical significance from 0.43${\pm}$0.27 units to 0.39${\pm}$0.25 units and from 0.32${\pm}$0.10 units to 0.30${\pm}$0.16 units respectively, and we experienced 2 total obstruction in Group II. Because the increased pulmonary blood flow by shunt operation has a favorable effect to the pulmonary arterial growth, the shunt operation is a recommended treatment in patients with hypoplastic pulmonary arteries. But in PA with ventricular septal defects, the change of juxtaductal stenosis is very important. In conclusion, the growth of ipsilateral (shunt site) pulmonary artery was promoted by shunt operation, but there is a tendency for the juxtaductal stenosis to be aggravated. And we experienced 2 total obstruction in Group II. Conclusion: Thus, in cases operated with shunt method, much careful postoperative follow up study including angiographic evaluation is needed, and after the shunt operation on the side of pulmonary artery associated with juxtaductal stenosis, early precise planning for total correction is recommended.

  • PDF

The Short Term Results of the Total Aortic Arch Replacement with Arch First Technique (궁부문합 선행법에 의한 대동맥 전궁치환술의 단기 임상 성적)

  • 우종수;김시호;방정희;이길수;최필조;조광조
    • Journal of Chest Surgery
    • /
    • v.37 no.11
    • /
    • pp.903-910
    • /
    • 2004
  • Background: The total aortic arch replacement is one of the most difficult operations with high mortality rate. But the arch first technique with subclavian arterial perfusion has been reported to be a safe methods for arch replacement. Material and Method: Between Feb 2003 and July 2004, 18 patients, 10 men and 8 women, underwent total aortic arch replacement with arch first technique. Their mean age was $59.3\pm12.9$ years. The patietns received 11 acute aortic dissections, 3 chronic aortic dissectiong aneurysms, and 4 ruptured aortic arch aneurysms. Result The mean admission period was $20.2\pm7.4$ days. There was one early mortality case which died of low cardiac output syndrome and another late mortality case which died of cerebral hemorrhage. The others were discharged without any sequelae and they were followed up for an average period of $180\pm156.3$ days. Conclusion: The total aortic arch replacement with arch first technique and subclavian arterial perfusion is a good method that will reduce the surgical mortality and the possibility of secondary late reoperation from the remnant distal aortic problems.

Endovascular Repair of Acute Type B Aortic Dissection: The Early Results and Aortic Wall Changes (급성 B형 대동맥 박리의 혈관내 스텐트-그라프트 삽입이 초기성적 및 대동맥 벽의 변화)

  • Her, Keun;Won, Yong-Soon;Shin, Hwa-Kyun;Yang, Jin-Sung;Baek, Kang-Seok
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.648-654
    • /
    • 2010
  • Background: This study assessed the early results of endovascular repair of acute type B aortic dissection and the aortic wall changes following endovascular repair. Material and Method: From July 2008 to May 2009, the preoperative and follow-up computed tomography (CT) scans of 5 patients with acute type B aortic dissection were evaluated, and these patients had underwent stent graft implantation within 13 days of the onset of dissection (mean: 7 days; range: 3~13). The whole lumen (WL), true lumen (TL) and false lumen (FL) diameters were measured at the proximal (p), middle (m) and distal (d) third of the descending thoracic aorta. Result: The study included four men and one woman with an average age of $59.4{\pm}20.1$ years (age range: 37~79 years). The follow-up CT was performed and evaluated at 7 days and 6 months. The primary tear was completely sealed in all the patients. No paraplegia, paresis or peripheral ischemia occurred and none of the patients died. No endoleaks developed in any of the patients during follow-up. The TL diameters increased from 20.4 to 33.5 mm in the proximal third (p/3), from 19.5 to 29.8 mm in the middle third (m/3) and from 15.2 to 23.5 mm in the distal third (d/3). The FL diameters decreased from 18.7 to 0 mm in the p/3, from 15.4 to 0 mm in the m/3 and from 21.4 to 8.7 mm in the d/3. The changes in the TL diameter were statistically significant in the middle and distal aorta, and those changes in the FL diameter were not statistically significant. There was a decrease in the WL after repair, but this was not statistically Significant. In three patients, the false lumen disappeared completely on follow-up CT at 6 months. Two patients had patent false lumens and no thrombosis. Conclusion: The early results showed that endovascular repair was effective in treating acute type B aortic dissection, and endovascular repair promoted positive aortic wall changes.

Comparison of Pulsatile and Non-Pulsatile Extracorporeal Circulation on the Pattern of Coronary Artery Blood Flow (체외순환에서 박동 혈류와 비박동 혈류가 관상동맥 혈류양상에 미치는 영향에 대한 비교)

  • Son Ho Sung;Fang Yong Hu;Hwang Znuke;Min Byoung Ju;Cho Jong Ho;Park Sung Min;Lee Sung Ho;Kim Kwang Taik;Sun Kyung
    • Journal of Chest Surgery
    • /
    • v.38 no.2 s.247
    • /
    • pp.101-109
    • /
    • 2005
  • Background: In sudden cardiac arrest, the effective maintenance of coronary artery blood flow is of paramount importance for myocardial preservation as well as cardiac recovery and patient survival. The purpose of this study was to directly compare the effects of pulsatile and non-pulsatile circulation to coronary artery flow and myocardial preservation in cardiac arrest condition. Material and Method: A cardiopulmonary bypass circuit was constructed in a ventricular fibrillation model using fourteen Yorkshire swine weighing $25\~35$ kg each. The animals were randomly assigned to group I (n=7, non-pulsatile centrifugal pump) or group II (n=7, pulsatile T-PLS pump). Extra-corporeal circulation was maintained for two hours at a pump flow of 2 L/min. The left anterior descending coronary artery flow was measured with an ultrasonic coronary artery flow measurement system at baseline (before bypass) and at every 20 minutes after bypass. Serologic parameters were collected simultaneously at baseline, 1 hour, and 2 hours after bypass in the coronary sinus venous blood. The Mann-Whitney U test of STATISTICA 6.0 was used to determine intergroup significances using a p value of < 0.05. Result: The resistance index of the coronary artery was lower in group II and the difference was significant at 40 min, 80 min, 100 min and 120 min (p < 0.05). The mean velocity of the coronary artery was higher in group II throughout the study, and the difference was significant from 20 min after starting the pump (p < 0.05). The coronary artery blood flow was higher in group II throughout the study, and the difference was significant from 40 min to 120 min (p < 0.05) except at 80 min. Serologic parameters showed no differences between the groups at 1 hour and 2 hours after bypass in the coronary sinus blood. Conclusion: In cardiac arrest condition, pulsatile extracorporeal circulation provides more blood flow, higher flow velocity and less resistance to coronary artery than non-pulsatile circulation.